Results of transient thermal modeling in a simulated space environment.
Steady state and transient full-scale, half-scale and quarter-scale thermal models in simulated space environment
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Steady state and transient full-scale, half-scale and quarter-scale thermal models in simulated space environment
District-heating-and-cooling (DHC) systems are a proven energy solution that has been deployed for many years in a growing number of urban areas worldwide. They comprise a variety of technologies that seek to develop synergies between the production and supply of heat, cooling, domestic hot water and electricity. Although the benefits of DHC systems are significant and have been widely acclaimed, yet the full potential of modern DHC systems remains largely untapped. There are several opportunities for development of energy efficient DHC systems, which will enable the effective exploitation of alternative renewable resources, waste heat recovery, etc., in order to increase the overall efficiency and facilitate the transition towards the next generation of DHC systems. This motivated the need for modelling these complex systems. Large-scale modelling of DHC-networks is challenging, as it has several components such as buildings, pipes, valves, heating source, etc., interacting with each other. In this paper, we focus on building modelling. In particular, we present a gray-box methodology for thermal modelling of buildings. Gray-box modelling is a hybrid of data driven and physics based models where, coefficients of the equations from physics based models are learned using data. This approach allows us to capture the dynamics of the buildings more effectively as compared to pure data driven approach. Additionally, this approach results in a simpler models as compared to pure physics based models. We first develop the individual components of the building such as temperature evolution, flow controller, etc. These individual models are then integrated in to the complete gray-box model for the building. The model is validated using data collected from one of the buildings at Lule{\aa}, a city on the coast of northern Sweden.
This report describes the continuation of the Computational Fluid Dynamics (CFD) model of the Supo cooling system described in the report, Supo Thermal Model Development1, by Cynthia Buechler. The goal for this report is to estimate the natural convection heat transfer coefficient (HTC) of the system using the CFD results and to compare those results to remaining past operational data. Also, the correlation for determining radiolytic gas bubble size is reevaluated using the larger simulation sample size. The background, solution vessel geometry, mesh, material properties, and boundary conditions are developed in the same manner as the previous report. Although, the material properties and boundary conditions are determined using the appropriate experiment results for each individual power level.
This report describes the continuation of the Computational Fluid Dynamics (CFD) model of the Supo cooling system described in the reports, Supo Thermal Model Development, II, and III. In the previous reports, the solution natural convection of Supo was simulated using a 2D, axisymmetric model that altered the actual geometry. A 3D geometry of Supo will more accurately estimate the natural convection heat transfer coefficient (HTC) of the system since Supo contains several non-symmetric internal components that can only be modeled in 3D. This, in turn, will improve the natural convection HTC results for comparison purposes with past operational data and previous 2D CFD results. Unfortunately, the complexities of performing multiphase 3D CFD simulations has proven too large of a task for our current capabilities. Instead, this report will focus on the 3D model development for the 2.39 kW/L (31.3 kW) case and limitations and challenges associated with the 3D simulations.
This report describes the continuation of the work reported in “Argonne Bubble Experiment Thermal Model Development”. The experiment was performed at Argonne National Laboratory (ANL) in 2014. A rastered 35 MeV electron beam deposited power in a solution of uranyl sulfate, generating heat and radiolytic gas bubbles. Irradiations were performed at three beam power levels, 6, 12 and 15 kW. Solution temperatures were measured by thermocouples, and gas bubble behavior was observed. This report will describe the Computational Fluid Dynamics (CFD) model that was developed to calculate the temperatures and gas volume fractions in the solution vessel during the irradiations. The previous report described an initial analysis performed on a geometry that had not been updated to reflect the as-built solution vessel. Here, the as-built geometry is used. Monte-Carlo N-Particle (MCNP) calculations were performed on the updated geometry, and these results were used to define the power deposition profile for the CFD analyses, which were performed using Fluent, Ver. 16.2. CFD analyses were performed for the 12 and 15 kW irradiations, and further improvements to the model were incorporated, including the consideration of power deposition in nearby vessel components, gas mixture composition, and bubble size distribution. The temperature results of the CFD calculations are compared to experimental measurements.
A thermal computer model of the NSTAR (Nasa Solar Electric Propulsion Technology Applications Readiness) xenon ion thruster has been produced using a lumped parameter thermal nodal network scheme. This model contains 104 nodes on the thruster and was implemented using SINDA (Systems Improved Numerical Differencing Analyzer) and TRASYS (Thermal Radiation Analyzer System) on various UNIX workstations. The model includes radiation and conduction heat transfer, the effect of plasma interaction on the thruster, and an account for finely perforated surfaces. The model was developed in conjunction with an NSTAR thruster outfitted with approximately 20 thermocouples for thermal testing at the NASA Lewis Research Center. The results of these experiments were used to calibrate and confirm the computer model first without and then with the plasma interaction. The calibrated model was able to predict discharge chamber temperatures to within 10 C of measured temperatures. To demonstrate the ability of the model under various circumstances the heat flux was examined for a thruster operating in the environment of space.
Steady state and transient full-scale, half-scale and quarter-scale thermal models in simulated space environment
The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity through the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (550 K – 950 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management through a reduction of parasitic losses. These losses are comprised of (i) the heat input that does not participate in power production but simply bypasses the thermo-electrochemical process and is transferred to the condenser, and (ii) heat that is lost from the device directly to the surroundings due to poor insulation. Heat loss to the surroundings occurs from a lower average hot-side temperature given that a fraction of the power conversion occurs at an intermediate stage. Also, the condenser now directly interacts with the lower temperature of the intermediate stage, thereby reducing radiation loss. A simplified geometry is developed for this device to help guide its design from a heat transfer perspective. All thermal contact and boundary conditions are discussed, including the evaporation and condensation of sodium vapor, thermal leakage through the housing, and the thermal contact between the beta”-alumina and the housing. A ray tracing method assuming gray, diffuse surfaces is used to account for the internal radiation heat transfer within the device. Liquid sodium flows in a capillary wick between the condenser and the evaporator with Pe << 1, so only conduction heat transfer is considered within this liquid return path. For simplicity, natural convection between the sodium vapor and the device housing is neglected. A numerical linear resistance model (<5% error when compared to a finite element model) is used to determine the expected conversion temperatures of each stage for a range of candidate materials. Furthermore, a numerical model (<2% error) is developed to find the factor of increase in the thermal resistance for several designs of corrugated features for the device housing. By using an iterative scheme, efficiency vs. power curves are created for a number of material and size combinations. Finally, the fundamental tradeoff between the power and efficiency is explored in conjunction with the total system size.
As part of the Used Fuel Disposition Campaign of the Department of Energy (DOE), visual inspections and temperature measurements were performed on two storage modules in the Calvert Cliffs Nuclear Power Station’s Independent Spent Fuel Storage Installation (ISFSI). Detailed thermal models models were developed to obtain realistic temperature predictions for actual storage systems, in contrast to conservative and bounding design basis calculations.
This paper presents a thermal model for the performance analysis of a large scale cooling pond for the long term storage of spent nuclear fuel. The model has been developed using the knowledge gained from fundamental investigation using CFD and has been validated by comparing against reliable experimental and/or numerical data. It was then applied in the context of operation of a large scale pond to ascertain the sensitivity of various operational and environmental conditions. To develop the model, the water body along with the heating elements was considered as one zone and humid air inside the building as another zone, both of which are considered as well-mixed zones. Various input conditions namely, total heat load from the heat source, environmental temperature and relative humidity, ventilation rate, efficiency of the cooling tower, recirculation and make-up water flow rates have been programmed in the model. The statistical method AVONA has been used to assess the influence of the above variables. The results reveal that the efficiency of the cooling tower is the most influential parameter on the cooling performance of cooling pond within the considered values of heat load. It has also been found that the majority of the heat is taken by the recirculating water for very high heat load while the other modes of heat transfer are small but not insignificant. The model is capable of simulating the scenario of loss of cooling water and suggests that it can be used for managing a large pond efficiently as well as recovery from an accident situation. (authors)
The boundary conditions for thermal modeling of fenestration systems assume an adiabatic condition between the fenestration system installed and the opaque envelope system. This theoretical adiabatic boundary condition may not be appropriate owing to heat transfer at the interfaces, particularly for aluminum- framed windows affixed to metal- framed walls. In such scenarios, the heat transfer at the interface may increase the discrepancy between real world thermal indices and laboratory measured or calculated indices based on NFRC Rating System.This paper discusses the development of window-wall Interface Correction Factors (ICF) to improve energy impacts of building envelope systems
This paper describes the development of thermal models for the filling of high pressure hydrogen tanks with experimental validation. Two models are presented; the first uses a one-dimensional, transient, network flow analysis code developed at Sandia National Labs, and the second uses the commercially available CFD analysis tool Fluent. These models were developed to help assess the safety of Type IV high pressure hydrogen tanks during the filling process. The primary concern for these tanks is due to the increased susceptibility to fatigue failure of the liner caused by the fill process. Thus, a thorough understanding of temperature changes of the hydrogen gas and the heat transfer to the tank walls is essential. The effects of initial pressure, filling time, and fill procedure were investigated to quantify the temperature change and verify the accuracy of the models. In this paper we show that the predictions of mass averaged gas temperature for the one and three-dimensional models compare well with the experiment and both can be used to make predictions for final mass delivery. Furthermore, due to buoyancy and other three-dimensional effects, however, the maximum wall temperature cannot be predicted using one-dimensional tools alone which means that a three-dimensional analysis is required for a safety assessment of the system.
A relatively simple one-dimensional thermal model of the Bridgman growth process has been developed which is applicable to the growth of small diameter samples with conductivities similar to those of metallic alloys. The heat flow in a translating rod is analyzed in a way that is applicable to Biot numbers less than unity. The model accommodates an adiabatic zone, different heat transfer coefficients in the hot and cold zones, and changes in sample material properties associated with phase change. The analysis is applied to several simplified cases. The effect of the rod's motion is studied in a three-zone furnace for a rod sufficiently long that end effects can be neglected; end effects are then investigated for a motionless rod. Finally, the addition of a fourth zone, an independently controlled booster heater between the main heater and the adiabatic zone, is evaluated for its ability to increase the gradient in the sample at the melt interface and to control the position of the interface.
Thermal stability of critical instrument components is of serious concern for the Space Interferometer Mission (SIM). Within the SIM siderostat bay, thermal distortion of the siderostat mirror and the telescope primary and secondary mirrors must be controlled to ensure success of the mission.
Heat transfer in high-temperature, high-porosity, flexible refractory ceramic fibrous insulation felts is investigated. Heat transfer in these insulation materials consists of combined gas conduction, solid conduction, and radiation modes, with the precise theoretical modeling of the latter two modes being formidable. A semi-empirical model that requires inverse methods and steady-state thermal test data to infer some of the required model parameters is further developed in this study, and applied to five insulation materials for temperatures between 300 K and 1900 K. The steady-state thermal test setup at NASA Langley Research Center with recent modifications to increase its testing capability to 1900 K is discussed. Design considerations to ensure one-dimensional heat transfer in the test setup are described. Test data and corresponding thermal models for alumina and zirconia-based fibrous insulation felts are presented. Furthermore, test data and thermal models on two fibrous insulation samples containing additives to further suppress either radiation or gas conduction modes of heat transfer are presented. Previously published alumina-based insulation data are also re-processed using the updated modeling methodology. The significance of various heat transfer modes in typical insulation samples is discussed and used to provide general guidance on optimum insulation layups.
A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.
This work summarizes the findings of a reduced order model (ROM) study performed using Sierra ROM module Pressio_Aria on Sandia National Laboratories' (SNL) Crash-Burn L2 milestone thermal model with pristine geometry. Comparisons are made to full order model (FOM) results for this same Crash-Burn model using Sierra multiphysics module Aria.
Data acquired from the initial series of tests conducted to determine how thermal conditions affect SRB (Space Shuttle Solid Rocket Booster) flotation are presented. Acceleration, pressure, and temperature data recorded from initial water impact to final flotation position using a 12.5-inch diameter thermal model of the SRB at ambient pressure are included. The model was 136.9 inches long and weighed 117.3 lbm. The tests indicated the following differences from ambient temperature tests: (1) significant negative static pressures can occur during penetration; (2) maximum penetration is increased; and (3) final flotation is in the spar buoy mode.