Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Environments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Self-pressurization of a spherical liquid hydrogen storage tank in a microgravity environment

Thermal stratification and self-pressurization of partially filled liquid hydrogen (LH2) storage tanks under microgravity condition is studied theoretically. A spherical tank is subjected to a uniform and constant wall heat flux. It is assumed that a vapor bubble is located in the tank center such that the liquid-vapor interface and tank wall form two concentric spheres. This vapor bubble represents an idealized configuration of a wetting fluid in microgravity conditions. Dimensionless mass and energy conservation equations for both vapor and liquid regions are numerically solved. Coordinate transformation is used to capture the interface location which changes due to liquid thermal expansion, vapor compression, and mass transfer at liquid-vapor interface. The effects of tank size, liquid fill level, and wall heat flux on the pressure rise and thermal stratification are studied. Liquid thermal expansion tends to cause vapor condensation and wall heat flux tends to cause liquid evaporation at the interface. The combined effects determine the direction of mass transfer at the interface. Liquid superheat increases with increasing wall heat flux and liquid fill level and approaches an asymptotic value.

Lin, C. S.↗

Self-pressurization of a spherical liquid hydrogen storage tank in a microgravity environment

Thermal stratification and self-pressurization of partially filled liquid hydrogen (LH2) storage tanks under microgravity condition is studied theoretically. A spherical tank is subjected to a uniform and constant wall heat flux. It is assumed that a vapor bubble is located in the tank center such that the liquid-vapor interface and tank wall form two concentric spheres. This vapor bubble represents an idealized configuration of a wetting fluid in microgravity conditions. Dimensionless mass and energy conservation equations for both vapor and liquid regions are numerically solved. Coordinate transformation is used to capture the interface location which changes due to liquid thermal expansion, vapor compression, and mass transfer at liquid-vapor interface. The effects of tank size, liquid fill level, and wall heat flux on the pressure rise and thermal stratification are studied. Liquid thermal expansion tends to cause vapor condensation and wall heat flux tends to cause liquid evaporation at the interface. The combined effects determine the direction of mass transfer at the interface. Liquid superheat increases with increasing wall heat flux and liquid fill level and approaches an asymptotic value.

Lin, C. S.↗

A water blown urethane insulation for use in cryogenic environments

Thermal Protection Systems (TPS) of NASA's Space Shuttle External Tank include polyurethane and polyisocyanurate modified polyurethane foam insulations. These insulations, currently foamed with CFC 11 blowing agent, serve to maintain cryogenic propellant quality, maintain the external tank structural temperature limits, and minimize the formation of ice and frost that could potentially damage the ceramic insulation on the space shuttle orbiter. During flight the external tank insulations are exposed to mechanical, thermal and acoustical stresses. TPS must pass cryogenic flexure and substrate adhesion tests at -253 C, aerothermal and radiant heating tests at fluxes up to approximately 14 kilowatts per square meter, and thermal conductivity tests at cryogenic and elevated temperatures. Due to environmental concerns, the polyurethane insulation industry and the External Tank Project are tasked with replacing CFC 11. The flight qualification of foam insulations employing HCFC 141b as a foaming agent is currently in progress; HCFC 141b blown insulations are scheduled for production implementation in 1995. Realizing that the second generation HCFC blowing agents are an interim solution, the evaluation of third generation blowing agents with zero ozone depletion potential is underway. NASA's TPS Materials Research Laboratory is evaluating third generation blowing agents in cryogenic insulations for the External Tank; one option being investigated is the use of water as a foaming agent. A dimensionally stable insulation with low friability, good adhesion to cryogenic substrates, and acceptable thermal conductivity has been developed with low viscosity materials that are easily processed in molding applications. The development criteria, statistical experimental approach, and resulting foam properties will be presented.

Blevins, Elana↗

Thermal Considerations for 2039 Opposition Class Nuclear Electric Propulsion/Chemical Propulsion Crewed Mars Mission

The high specific impulse (Isp) of Nuclear Electric Propulsion (NEP) technology offers the potential for advanced space mission capabilities. However, the five critical technology elements of NEP vehicles have yet to prove technical maturity levels for consideration into mission design. In response to the critical reviews by the NASA Engineering and Safety Center (NESC) and the National Academies of Sciences, Engineering, and Medicine (NASEM), NASA’s Space Nuclear Propulsion (SNP) project created an NEP Technology Maturation Plan (TMP) for focused development of NEP technology. The TMP called for a coordinated set of technology development efforts to meet this objective. The Modular Assembled Radiators for NEP VehicLes (MARVL) Early Career Initiative (ECI) project was initiated to develop a portion of the fifth Critical Technology Element (CTE) of the NEP vehicle: the Primary Heat Rejection Subsystem (PHRS). A target application of a 2039 human-rated Mars mission was outlined in the TMP. For the outlined mission, a NEP vehicle will experience several thermal environments which will impact the design and operation of the PHRS. To maintain radiator temperatures within the required effective temperature range, the effect of natural, induced, and NEP internally generated heat loads on the radiator panel must be well understood. Furthermore, this analysis is critical for analyzing the influence of various orientations and positions of the NEP vehicle relative to nearby celestial bodies throughout the mission. This study conducted a complete enveloping analysis of the thermal environments influencing the NEP vehicle throughout the mission. Thermal analysis was conducted for the radiator panels based on the defined mission environments. This thermal analysis concludes with the selection of ideal radiator orientations for the NEP vehicle, and the identification of worst case hot and cold environmental sink temperatures throughout the mission. For the target application, the environmental sink temperature while the reactor is powered OFF or powered ON ranges from 30 K to 353 K and 2.7 K to 243 K respectively. When considering interplanetary space, the minimum environmental sink temperature when the reactor is powered OFF and the radiators are oriented “edge to Sun” is 2.7 K. The environmental thermal models generated in this study will be used for future studies with the full vehicle system model. The environmental sink temperature curves generated will be used for future radiator and component analysis to predict transient performance in the space environment. The environmental sink temperature and heat rejection capability curves will inform the trade between commissioning orbits that are in consideration. The model may also serve as a useful tool as reference for future crewed space missions, missions involving radiators or temperature sensitive equipment, or other missions requiring analysis of natural orbital thermal environments.

Nuclear Electric Propulsion↗

Self-regulating heater application to Shuttle/Centaur hydrazine fuel line thermal control

The Shuttle/Centaur high energy upper stage vehicle thermal environments were more severe than previous Centaur vehicle thermal environments, creating need for a new hydrazine fuel line thermal control technique. Constant power heaters did not satisfy power dissipation requirements, because the power required to maintain fuel line thermal control during cold conditions exceeded the maximum power allowable during hot conditions. Therefore, a Raychem Thermolimit self-regulating heater was selected for this application, and was attached to the hydrazine fuel line with Kapton and aluminum foil tapes. Fuel line/heater thermal modeling and subsequent thermal vacuum chamber testing simulated heater thermal performance during all worst-case Shuttle/Centaur thermal environmental conditions. Fuel line temperatures were maintained between the 4C to 71C limits during all analytical and test cases. Finally, the thermal model predictions were correlated with the test data, thereby ensuring that the model would provide satisfactory predictions for future missions and/or vehicles.

Unkrich, David B.↗

Results from SIM's Thermo-Opto-Mechanical (TOM3) Testbed

Future space-based optical interferometers, such as the Space Interferometer Mission Planet Quest (SIM), require thermal stability of the optical wavefront to the level of picometers in order to produce astrometric data at the micro-arc-second level. In SIM, the internal path of the interferometer will be measured with a small metrology beam whereas the starlight fringe position is estimated from a large concentric annular beam. To achieve the micro-arc-second observation goal for SIM, it is necessary to maintain the optical path difference between the central and the outer annulus portions of the wavefront of the front-end telescope optics to a few tens of picometers. The Thermo-Opto-Mecha nical testbed (TOM3) was developed at the Jet Propulsion Laboratory to measure thermally induced optical deformations of a full-size flight-like beam compressor and siderostat, the two largest optics on SIM, in flight-like thermal environments. A Common Path Heterodyne Interferometer (COPHI) developed at JPL was used for the fine optical path difference measurement as the metrology sensor. The system was integrated inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. The siderostat was installed in a temperature-controlled thermal shroud inside the vacuum chamber, creating a flight-like thermal environment. Detailed thermal and structural models of the test articles (siderostat and compressor) were also developed for model prediction and correlation of the thermal deformations. Experimental data shows SIM required thermal stability of the test articles and good agreement with the model predictions.

interferometry↗

Turbomachinery Design Quality Checks to Avoid Friction Induced Structural Failure

A unique configuration of the P&W SSME Alternate Fuel Turbopump turbine disk/blade assembly, combined with a severe thermal environment, resulted in several structural anomalies that were driven by frictional contact forces. Understanding the mechanics of these problems provides new quality checks for future turbo machinery designs. During development testing in 1997 of the SSME alternate fuel turbopump at Stennis Space Center, several potentially serious problems surfaced with the turbine disk/blade assembly that had not been experienced in extensive earlier testing. Changes to the operational thermal environment were noted based on analytical prediction of modifications that affected performance and on stationary thermal measurements adjacent to the rotor assembly. A detailed structural investigation was required to reveal the mechanism of distress induced by the change. The turbine disk experienced cracking in several locations due to increased thermal gradient induced stress during start and shutdown transients. This was easily predictable using standard analysis procedures and expected once the thermal environment was characterized. What was not expected was the curling of a piston ring used for blade axial retention in the disk, indentation of the axial face of the blade attachment by a spacer separating the first and second stage blades, and most significantly, galling and cracking of the blade root attachment that could have resulted in blade release. Past experience, in gas turbine environments, set a precedent of never relying on friction for help and to evaluate it only in specific instances where it was obvious that it would degrade capability. In each of the three cases above, friction proved to be a determining factor that pushed the components into an unsatisfactory mode of operation. The higher than expected temperatures and rapid thermal transients combined with friction to move beyond past experience. The turbine disk/blade assembly configuration contributed to the potential for these problems to occur by limiting the radial deflection from thermals and centrifugal loading. The cooled solid bore configuration was chosen to improve rotordynamic stability by limiting the length of rotor overhang while still protecting the roller bearing by maintaining zero slope under the inner race. During a start transient, the rim area of the disk heats rapidly and expands axially and circumferentially and requires corresponding radial and axial growth of the disk to maintain relative positioning of the disk, blades, spacers and retainer rings. The stiffness, large thermal mass, and bore cooling flow combine to severely limit the disk rim radial growth which results in the potential for relative movement between these parts. Friction then becomes a player in the determination of component stress.

Moore, Jerry H.↗

Orbiter entry trajectory considerations

Space shuttle trajectory-shaping optimization considering the vehicle's thermal environment and the resulting requirements of the thermal protection system (TPS) are discussed. Optimization studies have been conducted yielding results which are generally applicable to shuttle orbiters and are independent of evolution and redirection of the space shuttle program. Two investigations of optimal trajectory shaping, with different methods of considering the thermal environment are presented.

Rehder, J. J.↗

Booster aerodynamic heating: Test support

Several technical areas were encompassed in providing support for booster thermal environment test work. These areas included: (1) cavity flow heating, (2) rarefied flow heating, and (3) impulse operated model research and testing. Cavity flow heating problems were studied with respect to the proposed altitude control motors for the space shuttle. Available literature on this subject was reviewed and analytical predictive methods were summarized for use in planning testing work. Rarefied flow heating data was reviewed and correlated. The study showed the importance of considering rarefied flow conditions in launch thermal environment prediction. Impulse operated model research and testing was conducted to provide a basis for understanding and designing such models for booster thermal environment testing.

Engel, C. D.↗

Advances in Single and Multijunction III-V Photovoltaics on Silicon for Space Power

A collaborative research effort at MIT, Ohio State University and NASA has resulted in the demonstration of record quality gallium arsenide (GaAs) based single junction photovoltaic devices on silicon (Si) substrates. The ability to integrate highly efficient, radiation hard III-V based devices on silicon offers the potential for dramatic reductions in cell mass (approx.2x) and increases in cell area. Both of these improvements offer the potential for dramatic reductions in the cost of on-orbit electrical power. Recently, lattice matched InGaP/GaAs and metamorphic InGaP/InGaAs dual junction solar cells were demonstrated by MBE and OMVPE, respectively. Single junction GaAs on Si devices have been integrated into a space flight experiment (MISSES), scheduled to be launched to the International Space Station in March of 2005. I-V performance data from the GaAs/Si will be collected on-orbit and telemetered to ground stations daily. Microcracks in the GaAs epitaxial material, generated because of differences in the thermal expansion coefficient between GaAs and Si, are of concern in the widely varying thermal environment encountered in low Earth orbit. Ground based thermal life cycling (-80 C to + 80 C) equivalent to 1 year in LEO has been conducted on GaAs/Si devices with no discernable degradation in device performance, suggesting that microcracks may not limit the ability to field GaAs/Si in harsh thermal environments. Recent advances in the development and testing of III-V photovoltaic devices on Si will be presented.

Wilt, David M.↗

Aerothermodynamic heating environment and thermal protection materials comparison for manned Mars-earth return vehicles

The aerothermodynamic environment during the earth return portion of a specific manned Mars mission is studied. Particular attention is given to the earlier smaller crew return capsule and its thermal protection system requirements. Data are presented on the stagnation region of a generic Mars return capsule. Insulation material thicknesses required to maintain allowable structural temperatures throughout a prolonged heat soak period are estimated.

Henline, William D.↗

A High Angle of Attack Inviscid Shuttle Orbiter Computation

An accurate description of the aerothermal environment is required to minimize the weight of the Thermal Protection System required on the leeside of winged reentry vehicles. The inability of ground-test facilities to reproduce the high enthalpy, separated flow present during reentry flight conditions, coupled with the prohibitive expense of flight tests, leads to the use of an analytical method - namely Computational Fluid Dynamics (CFD) - to describe the flow. While the ultimate goal of this work is to accurately predict the leeside flow and its associated thermal environment, an essential and reasonable first step towards that goal is a comparison of pressure predictions by a code with wind-tunnel data. Until such CFD pressure predictions agree with wind-tunnel test cases, there is little hope of accurately predicting the thermal environment at flight conditions. Thus, the objective of this study is to compare the pressure distributions predicted by inviscid, perfect gas CFD to Shuttle Orbiter wind-tunnel data and to address any significant issues encountered during the computation. While flight data is available for the Shuttle Orbiter, a wind-tunnel case is chosen for this study to allow a tractable problem for preliminary investigation. A wind-tunnel case allows the perfect gas assumption for the flow chemistry. This provides a significant computational savings over a several species finite-rate chemistry model which would be necessary if high-temperature effects present at flight conditions were to be included. In addition, by concentrating on the surface pressures, the analysis need only consider inviscid flow for general evaluation of the code capability. This further reduces the computational expense due to the absence of viscous terms and the associated decrease in the number of points required for the computational grid. Previous computational efforts (such as STEIN and HALIS) have been directed toward the windward surface quantities, primarily due to restrictions in treating either the winged geometry or its associated subsonic regions at high angle of attack. The code used for this study, the LAURA (Langley Aerothermodynamic Upwind Relaxation Algorithm) code of Gnoffo, represents a state-of-the-art code for computing the flow over complex configurations at hypersonic speeds. In the study, the LAURA code is applied to a wind-tunnel condition to initiate the assessment of the code's ability to predict the flow over a relatively complex hypersonic vehicle at high angles of attack. This presentation is used to highlight the pertinent results of a more detailed investigation of the inviscid calculation over the Shuttle Orbiter with the LAURA code.

William L. Kleb↗

Radiative cryogenic cooler for the near infrared mapping spectrometer for the Galileo Jupiter Orbiter

Summaries of the thermal design, analysis, and testing of a radiative cooler for the Near Infrared Mapping Spectrometer (NIMS) for the Galileo Jupiter Orbiter are presented. The radiative cooler rejects approximately 120 milliwatts of heat at a temperature of 75K when operating in the worst-case thermal environment. The cooler is designed to operate against a relatively hostile thermal environment which varies over 145 deg of instrument scan angle and which includes planetary radiation, solar radiation, and emissions from warm spacecraft surfaces (some of which rotate periodically through the radiator field of view).

Cafferty, T. T.↗

Recent Load Calibrations Experience with the YF-12 Airplane

The use of calibrated strain gages to measure wing loads on the YF-12A airplane is discussed as well as structural configurations relative to the thermal environment and resulting thermal stresses. A thermal calibration of the YF-12A is described to illustrate how contaminating thermal effects can be removed from loads equations. The relationship between ground load calibrations and flight measurements is examined for possible errors, and an analytical approach to accommodate such errors is presented.

Jenkins, J. M.↗

Moire interferometry for thermal expansion of composites

Moire interferometry by reflection is described and demonstrated for the case of a real reference grating of 1200 lines/mm. Extraneous beams can be displaced and stopped by using a wedge-shaped air gap between reference and specimen gratings. Double-order dominance, the use of diffraction sequences for reflection, the isolation of preferred sequences, and the use of two-beam interference are discussed. Experimental accuracy is enhanced significantly by using several data points to establish displacements along a line, and random errors characterized by one standard deviation can be as small as one microstrain. The method is well adapted to thermal environments, coefficients of thermal expansion of selected graphite-epoxy laminates being determined in the temperature range of 297-422 K. Very good precision was achieved for a wide range of thermal expansion coefficients, from approximately zero to 27 microstrains/K.

Bowles, D. E.↗

The Instrument Test Dewar (ITD): Testing satellite instruments at 1.5 K

The Instrument Test Dewar (ITD) is a cryogenic facility designed and built to test Cosmic Background Explorer (COBE) satellite instruments at 1.5 K. The facility provides a high vacuum and thermal environment with payload thermal, electrical and optical interfaces. There are two concentric vacuum spaces which are not hermitically sealed. The instrument vacuum space is 81.28 cm by 243.84 cm and is cooled by an LHe shroud. The guard vacuum space surrounds an LN2 shroud. There are two separate cryosorption pumping systems and a mechanical LHe pumping system. The data acquisition systems provide payload and housekeeping data. There have been various problems with the facility, and changes and improvements have been made to assure optimum test conditions. COBE instrument testing has been completed on structural, thermal model hardware and the protoflight units.

Milam, Laura J.↗