Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Segmentation of Lightweight Ablator Micro-Tomography Using Deep Learning

Ablative thermal protection systems (TPS) are essential for high speed entry of planetary atmospheres, such as those of Earth and Mars. Upon entry the kinetic energy of the spacecraft is converted into thermal energy, leading to high heat fluxes at the wall of the craft. Because of this extreme heating, a robust ablative TPS material must be selected. A common material selection today is phenolic-impregnated carbon ablator (PICA), which is a low-density carbon material known for producing dust that is not suitable to a cleanroom environment. To mitigate dust created by a PICA heatshield, a silicone-based spray called NuSil is applied to the surface of the TPS, creating PICA-NuSil (PICA-N). PICA-N has been observed to have a different material response from regular PICA during high enthalpy flow testing, producing surface temperatures up to 200K less than those seen for PICA [1]. To better understand this phenomenon, it is critical that robust methods of PICA-N material characterization are developed. The purpose of this project is to investigate Object Research Systems’ (ORS) Dragonfly deep learning tools as a means of accurately segmenting and characterizing PICA-N. Systematic testing of this software has shown that Dragonfly deep learning tools have strong potential for accurate segmentation/ characterization of PICA-N and other TPS materials.

Micro-tomography↗

The Nature of Insoluble Organic Matter in Sutter’s Mill and Murchison Carbonaceous Chondrites: Testing the Effect of X-ray Computed Tomography (XCT) and Exploring Parent Body Organic Molecular Evolution

This study analyzed samples of the Murchison and Sutter’s Mill carbonaceous chondrite meteorites in support of the future analysis of samples returned from the asteroid (10155) Bennu by the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) mission. Focusing specifically on the insoluble organic matter (IOM), this study establishes that a total of 1.3 g of bulk sample from a single chondritic meteorite is sufficient to obtain a wide range of cosmochemical information, including light element analysis (H, C, and N), isotopic analysis (D/H, 13 C/ 12 C, and 15 N/ 14 N), and X-ray fluorescence spectroscopy for major elemental abundances. IOM isolated from the bulk meteorite samples was analyzed by light element and isotopic analysis as described above, 1 H and 13 C solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, and complete noble gas analyses (abundances and isotopes). The samples studied included a pair from Murchison (CM2), one of which had been irradiated with high-energy X-rays in the course of computed tomographic imaging. No differences between the irradiated and non-irradiated Murchison samples were observed in the many different chemical and spectroscopic analyses, indicating that any X-ray–derived sample damage is below levels of detection. Elemental, isotopic, and molecular spectroscopic data derived from IOM isolated from the Sutter’s Mill sample reveals evidence that this meteorite falls into the class of heated CM chondrites.

planetary science↗

Computerized tomography using video recorded fluoroscopic images

A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

Kak, A. C.↗

Positron emission reconstruction tomography for the assessment of regional myocardial metabolism by the administration of substrates labeled with cyclotron produced radionuclides

A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.

Ter-Pogossian, M. M.↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

Computerized tomography using video recorded fluoroscopic images

The use of video-recorded fluoroscopic images as input data for digital reconstruction of objects from their projections is examined. The fluoroscopic and the scanning apparatus used for the experiments are of a commercial type already in existence in most hospitals. It is shown that for beams with divergence up to about 15 deg, one can use a convolution algorithm designed for the parallel radiation case with negligible degradation both quantitatively and from a visual quality standpoint. This convolution algorithm is computationally more efficient than either the algebraic techniques or the convolution algorithms for radially diverging data. Results from studies on Lucite phantoms and a freshly sacrificed rat are included.

Kak, A. C.↗

High-speed computerized tomography

The development of a high-speed reconstruction processor and a channelized architecture to use with a high-resolution tomographic unit is discussed with attention to the convolution reconstruction algorithm. By means of this algorithm, input data and intermediate result precision required throughout the algorithm execution have been studied with computer simulation using profile data derived from mathematically simulated test objects and experimental animal data. A prototype section for a highly parallel all-digital system executes 60 million arithmetic operations per second, and the full-scale version is expected to reconstruct 500 to 1000 cross sections per second.

Swartzlander, E. E., Jr.↗

Computer tomography of flows external to test models

Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.

Prikryl, I.↗