Comparing Vapor Penetration Measurements from IR Thermography of C-H Stretch with Schlieren during Fuel Injection in a Heavy-Duty Diesel Engine.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This exploratory project, entitled “Non-Destructive In-process Assessment of Thermal Spray Repairs,” evaluated the capabilities and limitations of four non-destructive testing (NDE) technologies for detection of defects in as-sprayed thermal spray coatings: acousto-ultrasonics, vibro-thermography, thermal wave infrared (IR) imaging, and flash IR thermography. The project goal was to identify a single technology suitable for use as an in-process inspection for two common classes of defects in thermal spray coatings, porosity and disbonds. Two rounds of test coupons were fabricated with intentionally seeded defects in AISI 420 stainless steel coatings deposited by twin wire arc (TWA) spray onto gray cast iron substrates. These standardized test coupons allowed the sensitivity of the four NDE methods to be directly compared. The results indicated that the acousto-ultrasonic method will not meet requirements for accuracy, inspection time, and reproducibility, while the vibrothermography method will not meet requirements for integration within remanufacturing cells and process flows. The IR methods, thermal wave imaging and flash thermography, both exhibited acceptable accuracy and reproducibility; however, the former method does not meet the requirement for inspection time. Flash IR thermography met all requirements in the initial round of testing, and that result was confirmed in a second round of testing on samples with a larger, more complex geometry. A final recommendation for further development of flash IR thermography was therefore made based upon i) detection performance, and ii) feasibility of deployment into the target application of resurfacing CAT engine blocks and headers.
Porosity and fatigue cracking are two critical factors that affect the performance and safety of cryogenic fuel tanks and feedlines made from unlined laminated or weaved carbon/epoxy materials. This paper presents the experiments to induce fatigue cracking of laminated composites through thermal cycling as well as the feasibility of using Thermography and Ultrasound Spectroscopy technology (UT) to detect and measure such micro-cracking. Carbon/epoxy laminated composite panels were built and cut into strips. These specimens were partially submerged in liquid nitrogen while subjected to various loads on a test machine. Edges of some specimens were polished and etched to determine the degree of micro-cracking. The rest of specimens were then examined with Thermography and Ultrasound Spectroscopy NDE systems to investigate the feasibility of finding such micro-cracking in the laminated composites. Thermography is utilized to determine changes in thermal diffusivity. The degree of cracking may reduce the apparent thermal diffusivity and therefore change the thermal response on the surface. Thermography testing was conducted on a group of specimens where it is desired to have some correlation between the predetermined stress and the thermography data. Ultrasound Spectroscopy was used to determine peak changes between the pre-stressed and stressed samples. Data from the inspections were analyzed and the results are presented in this paper.
Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.
The negative ion source test facility ELISE (Extraction from a Large Ion Source Experiment) is in operation since beginning of 2013 at the Max-Planck-Institut für Plasmaphysik (IPP) in Garching bei München. The large radio frequency driven ion source of ELISE is about 1×1 m{sup 2} in size (1/2 the ITER source) and can produce a plasma for up to 1 h. Negative ions can be extracted and accelerated by an ITER-like extraction system made of 3 grids with an area of 0.1 m{sup 2}, for 10 s every 3 minutes. A total accelerating voltage of up to 60 kV is available, i.e. a maximum ion beam power of about 1.2 MW can be produced. ELISE is equipped with several beam diagnostic tools for the evaluation of the beam characteristics. In order to evaluate the beam properties with a high level of detail, a sophisticated diagnostic calorimeter has been installed in the test facility at the end of 2013, starting operation in January 2014. The diagnostic calorimeter is split into 4 copper plates with separate water calorimetry for each of the plates. Each calorimeter plate is made of 15×15 copper blocks, which act as many separate inertial calorimeters and are attached to a copper plate with an embedded cooling circuit. The block geometry and the connection with the cooling plate are optimized to accurately measure the time-averaged power of the 10 s ion beam. The surface of the blocks is covered with a black coating that allows infrared (IR) thermography which provides a 2D profile of the beam power density. In order to calibrate the IR thermography, 48 thermocouples are installed in as many blocks, arranged in two vertical and two horizontal rows. The paper describes the beam calorimetry in ELISE, including the methods used for the IR thermography, the water calorimetry and the analytical methods for beam profile evaluation. It is shown how the maximum beam inhomogeneity amounts to 13% in average. The beam divergence derived by IR thermography ranges between 1° and 4° and correlates relatively well with the values measured by beam emission spectroscopy with up to 30% difference. It has also been observed that the beam inhomogeneity decreases with lower beam divergence.
Aerial thermography is an emerging technology unsurpassed for locating groundwater discharges. Thermography can be used to locate submerged discharges that are extremely difficult to find by other means. In two large projects, thermography was used to identify almost every significant spring at sites underlain by karst aquifers. This technology effectively converts Brown's Type 5 topology to types 1 or 2 (all discharges known), which has a significant impact on dye tracing. At a north Alabama site, springs located by thermography quadrupled the known groundwater discharge in and around the site. For submerged discharges, thermographic temperatures can be measured down the center of the groundwater plume that rises to the surface in the winter. Using the Cornell Mixing (CORMIX) model, flow rate for one submerged spring was estimated. Once identified, estimates of spring recharge area were desired. The size of the area of recharge was estimated by hydrograph separation of flow data from nearby, unregulated surface streams. Monthly recharge estimates were also made and used to show that in north Alabama the mean annual recharge/discharge occurs during May and December. Spring flow measurements for the same county of north Alabama were averaged to obtain mean flows. Then measurements for May only, were averaged. The two averages usually agreed to within 20 percent. This provides evidence that hydrograph separation determinations of recharge are valid.
The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the "good" material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued where a fixed set of eigenvectors, generated from an analytic model of the thermal response of the material under examination, is used to process the thermal data from the RCC materials. Details of a one-dimensional analytic model and a two-dimensional finite-element model will be presented. An overview of the PCA process as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens will be shown. Finally, a number of different applications of this technology to various RCC components will be presented.
The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the good material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued when a fixed set of eigenvectors is used to process the thermal data from the RCC materials. These eigen vectors can be generated either from an analytic model of the thermal response of the material under examination, or from a large cross section of experimental data. This paper will provide the details of the analytic model; an overview of the PCA process; as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens. Details of a system that has been developed to allow insitu inspection of a majority of shuttle RCC components will be presented along with the acceptance test results for this system. Additionally, the results of applying this technology to the Space Shuttle Discovery after its return from flight will be presented.
Composite honeycomb structures are widely used in aerospace applications due to their low weight and high strength advantages. Developing nondestructive evaluation (NDE) inspection methods are essential for their safe performance. Flash thermography is a commonly used technique for composite honeycomb structure inspections due to its large area and rapid inspection capability. Flash thermography is shown to be sensitive for detection of face sheet impact damage and face sheet to core disbond. Data processing techniques, using principal component analysis to improve the defect contrast, are discussed. Limitations to the thermal detection of the core are investigated. In addition to flash thermography, X-ray computed tomography is used. The aluminum honeycomb core provides excellent X-ray contrast compared to the composite face sheet. The X-ray CT technique was used to detect impact damage, core crushing, and skin to core disbonds. Additionally, the X-ray CT technique is used to validate the thermography results.
Flash thermography has been shown to be an effective method for detection of delaminations in carbon fiber reinforced polymer (CFRP) composite structures. Improved understanding of the limitations of the technique can be obtained by simulating the inspection process. Time domain finite difference and finite element methods are well suited for such simulations but can be computationally intensive. An alternate method is to solve the Laplace transform of the heat equation, then invert the Laplace transform to produce a time domain response. Often this is referred to as the thermal quadrupole method and is well suited for simulating flash thermography. The quadrupole method has been used extensively for simulating one-dimensional heat flow in multilayer systems with contact resistances at the interfaces. It is also applicable for three dimensional configurations, in particular for simulation of changes in thermographic response due to delaminations in composites. This presentation discusses three-dimensional simulations with realistic shapes and contact resistances at the interfaces between layers. The results of these simulations are compared to thermography measurements on composites specimens with impact induced delaminations.
We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.
Flash thermography has been shown to be an effective method for detection of delaminations in carbon fiber reinforced polymer (CFRP) composite structures. Improved understanding of thelimitations of the technique can be obtained by simulating the inspection process. Time domainfinite difference and finite element methods are well suited for such simulations but can be computationally intensive. An alternate method is to solve the Laplace transform of the heat equation, then invert the Laplace transform to produce a time domain response. Often this is referred to as the thermal quadrupole method and is well suited for simulating flash thermography. The quadrupole method has been used extensively for simulating one-dimensional heat flow in multilayer systems with contact resistances at the interfaces. It is also applicable for three dimensional configurations, in particular for simulation of changes in thermographic response due to delaminations in composites. This presentation discusses three-dimensional simulations with realistic shapes and contact resistances at the interfaces between layers. The results of these simulations are compared to thermography measurements on composites specimens with impact induced delaminations.
An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.
An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.