Water Vapor Intercomparisons TES - AIRS - AMSR
Water vapor intercomparisons using Tropospheric Emission Spectrometer (TES), Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Scanning Radiometer (AMSR) radiances are presented.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Water vapor intercomparisons using Tropospheric Emission Spectrometer (TES), Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Scanning Radiometer (AMSR) radiances are presented.
Vertical convective transport is a key element of the tropospheric circulation. Convection lofts air from the boundary layer into the free troposphere, allowing surface emissions to travel much further, and altering the rate of chemical processes such as ozone production. This study uses satellite observations to focus on the convective transport of CO from the boundary layer to the mid and upper troposphere. Our hypothesis is that strong convection associated with high rain rate regions leads to a correlation between mid level and upper level CO amounts. We first test this hypothesis using the Global Modeling Initiative (GMI) chemistry and transport model. We find the correlation is robust and increases as the precipitation rate (the strength of convection) increases. We next examine three years of CO profiles from the Tropospheric Emission Sounder (TES) and Microwave Limb Sounder (MLS) instruments aboard EOS Aura. Rain rates are taken from the Tropical Rainfall Measuring Mission (TRMM) 3B-42 multi-satellite product. Again we find a correlation between mid-level and upper tropospheric CO, which increases with rain rate. Our result shows the critical importance of tropical convection in coupling vertical levels of the troposphere in the transport of trace gases. The effect is seen most clearly in strong convective regions such as the Inter-tropical Convergence Zone.
Dust and ice play important roles in Martian atmospheric dynamics on all time scales. Dust loading in particular exerts an important control on atmospheric temperatures and thereby on the strength of the atmospheric circulation in any given year. We present the first comparisons of MGS-TES aerosol opacity profiles with MRO-MCS aerosol opacity profiles. While the differences in vertical resolution are significant (a factor of 2), we find good agreement at particular seasons between nightside zonal average dust opacity profiles from the two instruments. Derived water ice opacities are likewise similar but show greater variability.
TES V5 CH4 captures latitudinal gradients, regional variability and interannual variation in the free troposphere. V5 joint retrievals offer improved sensitivity to lower troposphere. Time series extends from 2004 to present. V5 reprocessing in progress. Upper tropospheric bias. Mitigated by N2O correction. Appears largely spatially uniform, so can be corrected. How to relate free-tropospheric values to surface emissions.
ACTPol is a polarization-sensitive receiver upgrade to the Atacama CosmologyTelescope (ACT) which will make millimeterwavelength measurements of the small-scale polarization anisotropies of the cosmic microwave background to investigate the properties of inflation, dark energy, dark matter, and neutrinos in the early Universe. ACTPol will employ three arrays of transition edge sensor (TES) bolometer detectors. The detectors, with a target transition temperature of 150 mK, will be operated at a bath temperature of 100 mK provided by a dilution refrigerator. One array operating at a central frequency of 150 GHz and consisting of 1024 TESes achieved first light at the ACT site in July 2013. We anticipate fielding the remainder of the focal plane, consisting of a second 150 GHz array and a multi-chroic array sensitive to 90 and 150 GHz, at the end of the 2013 observing season. In these proceedings, we present characterization of key detector parameters from measurements performed on the first array both in the lab and during initial field testing. We comment on the design goals, measurements, and uniformity of the detector transition temperatures, saturation powers, and thermal conductivities while detailing measurement methods and results for the detector optical efficiencies and time constants.
The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.
We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.
The performance of Transition-Edge Sensors (TES) and their SQUID multiplexed read-outs are very sensitive to the ambient magnetic field from Earth and fluctuations that can arise due to fluctuating magnetic fields outside of the focal plane assembly from the Adiabatic Demagnetization Refrigerator (ADR).Thus, the experimental platform we are building to test the FPA of the X-ray Integral Field Unit (X-IFU) of the Athena mission needs to include a series of shields and a coil in order to meet the following requirement of magnetic field density and uniformity.
We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.
The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.
The TES-8 was jettisoned from the International Space Station on January 31, 2019. As an orbital laboratory and 8th in on-going series, the design makes use of a standard set of interfaces and safety features that permit rapid re-flight. On this flight, an advanced Exo-Brake is flown with de-orbit targeting capability that will engender sample return capability from LEO platforms. A Virtual Reality data recording system uses stereo imaging and efficient data-compression with an NVIDIA GPU (Graphics Processing Unit) to permit compression and transmission of very large data files. An SDR (Software Defined Radio) will download data to the NEN (Near Earth Network) for the first time - demonstrating potential use in cis-lunar space using S-band. For the first time, a comparison will be made regarding the functionality of the Iridium and Globalstar short burst data modems - as essential communication tools for future nano-sat projects. Lastly, the 7 micro-processors and 4 cameras provide an excellent learning platform for university students and NASA young professionals.
ATHENA is a European led x-ray observatory due for launch in the early 2030s. The X-ray Integral Field Unit (X-IFU) instrument on ATHENA will have an array of 3168 TES microcalorimeters, 2.5 eV resolution (at 7 keV), 5 arc second angular resolution and a 5 arc minute field of view. As one example, will allow unprecedented views of composition and dynamics of galaxy clusters.
In this presentation, we present an investigation of the correlation between water-ice and dust in the MGS TES data set.
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.
Advances in nanosat subsystems over the past decade have taken the CubeSat standard from a communication-limited educational tool to a powerful platform enabling space research. The potential for autonomous operations may greatly increase the capability of downlinking even larger data sets. This is enabled through miniaturization of software-defined radio/cognitive communication solutions and a rapidly growing number of ground stations and satellite network crosslinks. The TechEdSat-n orbital flight series is currently demonstrating experiments using cognitive communication concepts including User Initiated Service (UIS) and High-rate Delay Tolerant Networks (HDTN), which show a significant step toward improved capability. At the core of this is the use of the Iridium L-band Short Burst Data (SBD) modems, pioneered by TES-n for space applications. SBD enables unique rapid command, control, and scheduling to initiate the UIS and HDTN protocols. This occurs by performing GPS-assisted on-orbit ephemeris determination, enabling negotiation with high bandwidth ground assets to repeatedly downlink over a specific commercial or government-owned ground station. The technique is RF band-agnostic and may be extended to higher bandwidth stations and SDRs. This may also include free-space optical communication, through both laser and omnidirectional LEDs, which can provide an attractive protocol for downlinking very large datasets over far fewer ground stations. In addition, this may be extended to lunar applications for such future concepts as LunaNet, whereby scheduling and cognitive technologies can assist in greatly improving Earth downlink capabilities with ground stations which will see greater competition for usage. Lastly, the NASA Communication Service Program (CSP), intended to eventually replace the NASA Tracking and Data Relay Satellite System (TDRSS) will also demonstrate the feasibility of commercially-provided satellite communication capabilities. All of these combined advances, including large advances in on-board computation on small platforms, will result in more remarkable data processing capability – yielding even more as of yet unknown discoveries.
Poster summarizing PIRT development for TES selection.
Explore the source record for details and available documents.
We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.