Thermocouples measure very-hot gas temperatures

Thermocouple probe incorporates small jet of inert gas to cool thermocouple. To measure gas temperatures, cooling jet is turned off momentarily, allowing thermocouple to heat up to near its melting point, then cooling is reapplied. Heating curve is recorded by high speed digital system. Computing system extrapolates final temperature thermocouple would have attained.

Glawe, G. E.↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Diurnal and semidiurnal nitrogen density and temperature variations from thermosphere probe measurements.

Amplitudes and phases for the diurnal and semidiurnal variations of thermospheric molecular nitrogen density and temperature are determined from data obtained by six rocket-launched thermosphere probes. The semidiurnal tide is significant for the lower thermosphere variations, where it could dominate in the N2 density at 140 km and in the temperature for altitudes between 170 and 200 km. At exospheric heights, the magnitudes of the semidiurnal modes in density and temperature are significantly smaller than those of the diurnal mode. The temperature phase is height-dependent in both diurnal and semidiurnal components below 200 km, thus contributing to phase differences between N2 density and temperature in both modes. No significant phase differences are apparent between N2 density and thermospheric temperature above 250 km.

Newton, G. P.↗

Recovery and radiation corrections and time constants of several sizes of shielded and unshielded thermocouple probes for measuring gas temperature

Performance characteristics were experimentally determined for several sizes of a shielded and unshielded thermocouple probe design. The probes are of swaged construction and were made of type K wire with a stainless steel sheath and shield and MgO insulation. The wire sizes ranged from 0.03- to 1.02-mm diameter for the unshielded design and from 0.16- to 0.81-mm diameter for the shielded design. The probes were tested through a Mach number range of 0.2 to 0.9, through a temperature range of room ambient to 1420 K, and through a total-pressure range of 0.03 to 0.2.2 MPa (0.3 to 22 atm). Tables and graphs are presented to aid in selecting a particular type and size. Recovery corrections, radiation corrections, and time constants were determined.

Glawe, G. E.↗

Analysis of a Pneumatic Probe for Measuring Exhaust-Gas Temperatures with Some Preliminary Experimental Results

A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy

Scadron, Marvin D.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

The first experiment is a study of a coaxial jet discharging into stagnant laboratory air, with center jet of a mixture of 5% oxygen and 95% helium by volume and coflow jet of air. The exit flow pressure of both center-jet and coflow nozzles is 1 atmosphere. The presence of oxygen in the center jet is to allow the use of an oxygen flow-tagging technique (RELIEF4) to obtain non-intrusive velocity measurements. Both jets are nominally Mach 1.8, but, because of the greater speed of sound, the center jet velocity is more than twice that of the coflow. The mixing layer which forms between the center jet and the coflow near the nozzle exit is compressible, with a calculated convective Mach number of approximately 0.7. This geometry has several advantages: The streamwise development of the flow is generally dominated by turbulent stresses (rather than pressure forces), and thus calculations are sensitive to turbulence modeling. It includes features present in supersonic combustors, including a compressible mixing layer near the nozzle exit and a light-gas/air plume downstream. Since it is a free jet, it provides easy access for both optical instrumentation and probes. Since it is axisymmetric, it requires fewer experimental measurements to fully characterize, and calculations can be performed with more modest computer resources. However, weak shock waves formed at the nozzle exit strengthen and turn normal as they approach the axis, complicating the flow. Care is thus taken in the design of the facility to provide as near as possible to 1-D flow at the exit of both center and coflow nozzles, and to minimize the strength of waves generated at the nozzle exit. Results from this experiment are compared to CFD solutions obtained by VULCAN, a previously developed code used in engine analysis. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Thus, the geometry is relatively simple and large regions of subsonic recirculating flow are avoided. The nominal entrance Mach number is 2 and the enthalpy of the test gas (hot air "simulant") is nominally that of Mach 7 flight. It was believed, on the basis of calculations performed that this would produce mixing-limited flow, that is to say, one for which chemical reaction to equilibrium proceeds at a much greater rate than mixing. It later proved that this was not the case. The primary experimental technique employed is coherent anti-Stokes Raman spectroscopy, known by its acronym CARS. The species probed is molecular nitrogen and the quantity measured is temperature. Intrusive probes, such as Pitot, total temperature, hot-wire, etc., are not used due to access difficulty and high heat flux in the combustor, and because they may alter the flow. CARS has several advantages over other optical methods. It is a relatively mature and well-understood technique. Signal levels are relatively high and the signal is in the form of a coherent (laser) beam that can be collected through small windows. Incoherent (non-CARS) interferences are rejected by spatial filtering.

Diskin, G. S.↗

Design and Operation of a Fast, Thin-Film Thermocouple Probe on a Turbine Engine

As a demonstration of technology maturation, a thin-film temperature sensor probe was fabricated and installed on a F117 turbofan engine via a borescope access port to monitor the temperature experienced in the bleed air passage of the compressor area during an engine checkout test run. To withstand the harsh conditions experienced in this environment, the sensor probe was built from high temperature materials. The thin-film thermocouple sensing elements were deposited by physical vapor deposition using pure metal elements, thus avoiding the inconsistencies of sputter-depositing particular percentages of materials to form standardized alloys commonly found in thermocouples. The sensor probe and assembly were subjected to a strict protocol of multi-axis vibrational testing as well as elevated temperature pressure testing to be qualified for this application. The thin-film thermocouple probe demonstrated a faster response than a traditional embedded thermocouple during the engine checkout run.

thermocouples↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test - Part 2 (Temperature and Humidity)

This paper provides a characterization of the temperature and humidity variations within icing cloud flows generated during the second Fundamental Ice Crystal Icing Physics test conducted in NASA’s Propulsion Systems Laboratory, in June of 2018. The tests were conducted at airflow velocities of 85, 135, and 185 m/s, a static pressure of 44.8 kPa, and a total temperature of 7.2 ⁰C. A custom rearward facing probe and commercial total air temperature probe were used to obtain temperature and humidity profiles of the icing cloud flow leaving the exit duct plane. Additional background humidity measurements were also obtained from a commercial total water content probe. The probes captured the changes in temperature and humidity that took place at the test section after the cloud was activated. As the main altitude airflow interacts with the icing cloud, their thermodynamic properties undergo substantial changes. Due to the particle nature of the icing cloud, the droplets and ice crystals tend to redistribute within the cloud as it propagates with the main flow. Data will be presented that shows how these factors affect the thermodynamic property distribution within the icing cloud. A discussion is given of the thermal balances in the icing cloud, between the evaporating spray droplets and the airflow, as a basis for interpreting the measured results.

Crystal Icing↗

A fast-response aspirating probe for measurements of total temperature and pressure in transonic cryogenic wind tunnel

A newly developed, 3-mm-diam, dual hot-wire aspirating probe was used to measure the time-resolved stagnation temperature and pressure in a transonic cryogenic wind tunnel. The probe consists of two coplanar constant temperature hot wires at different overheat ratios operating in a 1.5-mm-diam channel with a choked exit. Thus, the constant Mach number flow by the wires is influenced only by free-stream stagnation temperature and pressure. Diffusion of the free-stream Mach number to a lower value in the channel reduces the dynamic drag on the hot-wire. Frequency response of the present design is dc to 20 kHz. The probe was used to measure the unsteady wake shed from an oscillating airfoil tested in the 0.3-m Transonic Cryogenic Tunnel at NASA-Langley Research Center. The hot-wire lasted for more than ten hours before breaking, proving the ruggedness of the probe and the usefulness of the technique in a high dynamic pressure, transonic cryogenic wind tunnel. Typical data obtained from the experiment are presented after reduction to stagnation pressure and temperature.

Ng, W.-F.↗