Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE GRADIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Thermal confinement and transport in spherical tokamaks: a review

Here, we review the thermal plasma confinement and transport properties observed and predicted in low aspect ratio tokamaks, or spherical tokamaks (STs), which can depart significantly from those observed at higher aspect ratio. In particular, thermal energy confinement scalings show a strong, near linear dependence of energy confinement time on toroidal magnetic field, while the dependence on plasma current is more modest, the opposite of what is seen at higher aspect ratio. STs have revealed a very strong improvement in normalized confinement with decreasing collisionality, much stronger than at higher aspect ratio, which bodes well for an ST-based fusion pilot plant should this trend continue at an even lower collisionality than has already been accessed. These differences arise because of fundamental differences in transport in STs due to the more extreme toroidicity (i.e. reduced region of bad curvature), and to the relatively larger $E_r \times B$ shearing rates, both of which can suppress electrostatic drift wave instabilities at both ion and electron gyroradius scales. In addition, electromagnetic effects are much stronger in STs because they operate at high β T . Gyrokinetic (GK) studies, coupled with low- and high-k turbulence measurements, have shed light on the underlying physics controlling transport. At lower β T , both ion- and electron-scale electrostatic drift turbulence may be responsible for transport. At higher β T , microtearing, kinetic ballooning, and hybrid trapped electron/kinetic ballooning modes increasingly play a role, and they have a much stronger impact in the core of ST plasmas than at higher aspect ratio. Flow shear affects the balance between ion- and electron-scale modes. Non-linear GK simulations find regimes where the electron heat flux decreases with decreasing collisionality, consistent with the experimental global normalized confinement scaling. The ST is unique in that the relatively low toroidal magnetic field allows for localized measurements of electron-scale turbulence, and this coupled with turbulence measurements at ion-scales has facilitated detailed comparisons with GK simulations. These data have provided compelling evidence for the presence of ion temperature gradient and electron temperature gradient turbulence in some plasmas, and direct experimental support for the impact of experimental actuators like rotation shear, density gradient and magnetic shear on turbulence and transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

Molecular Processes in Comets

The research focused on molecular hydrogen and its response to ultraviolet radiation, photoelectron impact excitation and X-ray radiation and on the interpretation of the ultraviolet spectra of the Jupiter dayglow and auroras. A systematic effort was made to obtain reliable rate coefficients for rovibrational energy transfer of H2, particularly in collisions with hydrogen atoms. We carried out elaborate quantum-mechanical calculations of the scattering of H and H2 on what had been characterized as a reliable potential energy surface of the H3 molecular system. These calculations took into account reactive channels and rate coefficients for ortho-para transitions were obtained. Quantal calculations are too complex to be applied to all the possible rovibrational transitions and we turned to a semi-classical method. With it we calculated rate coefficients for transitions, reactive and non-reactive, for all the rovibrational levels. We carried out the calculations for three of the available H3 potential energy surfaces. We discovered an unexpected sensitivity of the rate coefficients for the non-reactive channels to the potential energy surface. This discovery stimulated more thorough investigations of the potential energy surface elsewhere and to the construction of a new surface. We have used it in further semi-classical calculations in work that will shortly be 2 completed and which, together with new quantum-mechanical calculations should comprise a set of reliable rate coefficients that can be used in discussions of H2 on the Jovian planets. We carried out a detailed study of the Jovian ultraviolet dayglow. There has been a long-running argument about the dayglow on Jupiter. There are two sources of excitation: fluorescence and photoelectron impact excitation. It had been argued that a third source "the electron glow" was needed to bring theory and observation into agreement. We believe we have shown conclusively that the third source is unnecessary. We have achieved a close quantitative agreement between the predicted spectrum arising from fluorescence and photoelectrons and the measured spectrum. We also demonstrated a method by which the presence of HD could be established observationary. Similar calculations were carried out of the ultraviolet spectra of the Jovian auroras. We again found close agreement. Indeed, the agreement was so detailed we were able to derive the temperature of the atmosphere. We found, contrary to the standard model of the time, a high temperature between 400 K and 600 K and established the presence of a significant temperature gradient. A large temperature gradient was indeed found by direct sampling with the Jupiter probe.

Dalgarno, A.↗

Pioneer 10 observation of the solar wind proton temperature heliocentric gradient

Solar wind isotropic proton temperatures as measured out to 12.2 AU heliocentric distance by the Ames plasma analyzer aboard Pioneer 10 are presented as consecutive averages over three Carrington solar rotations and discussed. The weighted least-squares fit of average temperature to heliocentric radial distance, R, yields the power law R sup -.52. These average proton temperatures are not correlated as well with Pioneer 10's heliocentric radial distance (-.85) as are the corresponding average Zurich sunspot numbers R sub z (-.95). Consequently, it is difficult to isolate the spatial gradient in the Pioneer 10 solar wind proton temperatures using that data alone.

Mihalov, J. D.↗

Thermal Effects on Far-Field Distributed Acoustic Strain-Rate Sensors

Summary Fiber-optic cables cemented outside of the casing of an unconventional well measure crosswell strain changes during fracturing of neighboring wells with low-frequency distributed acoustic sensing (LF-DAS). As a hydraulic fracture intersects an observation well instrumented with fiber-optic cables, the fracture fluid injected at ambient temperatures can cool a section of the sensing fiber. Often, LF-DAS and distributed temperature sensing (DTS) cables are run in tandem, enabling the detection of such cooling events. The increasing use of LF-DAS for characterizing unconventional hydraulic fracture completions demands an investigation of the effects of temperature on the measured strain response by LF-DAS. Researchers have demonstrated that LF-DAS can be used to extract the temporal derivative of temperature for use as a differential-temperature-gradient sensor. However, differential-temperature-gradient sensing is predicated on the ability to filter strain components out of the optical signal. In this work, beginning with an equation for optical phase shift of LF-DAS signals, a model relating strain, temperature, and optical phase shift is explicitly developed. The formula provides insights into the relative strength of strain and temperature effects on the phase shift. The uncertainty in the strain-rate measurements due to thermal effects is estimated. The relationship can also be used to quantify uncertainties in differential-temperature-gradient sensors due to strain perturbations. Additionally, a workflow is presented to simulate the LF-DAS response accounting for both strain and temperature effects. Hydraulic fracture geometries are generated with a 3D fracture simulator for a multistage unconventional completion. The fracture width distributions are imported by a displacement discontinuity method (DDM) program to compute the strain rates along an observation well. An analytic model is used to approximate the temperature in the fracture. Using the derived formulae for optical phase shift, the model outputs are then used to compute the LF-DAS response at a fiber-optic cable, enabling the generation of waterfall plots including both strain and thermal effects. The model results suggest that before, during, and immediately following a fracture intersecting a well instrumented with fiber, the strain on the fiber drives the LF-DAS signal. However, at later times, as completion fluid cools the observation well, the temperature component of the LF-DAS signal can be equal to or exceed the strain component. The modeled results are compared to a published field case in an attempt to enhance the interpretation of LF-DAS waterfall plots. Finally, we propose a sensing configuration to identify the events when “wet fractures” (fractures with fluids) intersect the observation well.

Engineering↗

Role of Simple Spatial Gradient in Reinforcing the Accuracy of Temperature Determination of HED Plasma via Spectral Line-Area Ratios

We report on the simulation of temperature gradients in tamped NaFMgO target-foil plasma, heated and backlit by z-pinch dynamic hohlraum radiation. Our approach compares the spectroscopic output of a collisional-radiative model (prismspect) with soft X-ray absorption spectra collected on Sandia National Laboratories’ (SNL) Z Pulsed Power Facility. The pattern of minimum χ2 is seen to agree with an efficient, three-parameter model. Results show that a negligible gradient in electron temperature Te is consistent with experimental data, justifying the assumptions of previous work. The predicted sensitivity of line spectra to the gradient-aligned profile of Te is documented for each spectral feature, so that the line-area ratio between a pair of spectral features may be assessed as a proxy for the existence and quantification of such gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Psyche Magnetometer Engineering Model Test and Thermal Model Correlation to Validate Operational Thermal Requirement

Psyche Fluxgate Magnetometer candidate fabricated by UCLA has a critical temperature gradient requirement inside the magnetometer sensor head. Since the temperature gradient requirement is a driving factor for the magnetometer operation and science data collection at 16 Psyche, it is critical to validate and verify this requirement via modeling and test. In this work, a thermal vacuum test was completed for Psyche flight-like magnetometer engineering model. Flight-like environments were simulated for a hot operational case (after launch), a cold survival case (cruise), and two cold operational cases to characterize thermal performance of the instrument. An additional, non-flight, steady-state test case was completed to better correlate the magnetometer thermal model. During the test, sensitive Cernox temperature sensors with accuracy of ±0.1°C were used to precisely characterize the temperature gradient and correlate the model to the best accuracy. Collected test data indicated power consumption of 28% lower than predicted. The temperature gradient measured met the expected value and the requirement. Test data indicated the magnetometer also met the AFTs in relevant hot and cold environments. Test Results were used to correlate the thermal model. The correlated thermal model will be integrated to the spacecraft thermal model to predict magnetometer thermal performance while collecting science data in Psyche orbits.

Caron, Ryan↗

Mo-100 Disk Structural Integrity Tests II

This report is a continuation of the work performed in the report, Mo-100 Disk Structural Integrity Tests I [1]. The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in-beam during production. These large temperature gradients cause high stress and deformation within the disks that could prove detrimental to the target assembly’s cooling performance. Disk fracture is also a possibility that must be understood. Therefore, disk structural integrity tests were performed to understand the thermal induced behavior of these disks. In order to replicate the in-beam conditions, the Mo-100 disks were subjected to large temperature gradients using a 30kW induction heater and coil. A series of transient tests were conducted in a similar fashion as the previous work, as well as an attempt to create steady state conditions for more accurate temperature gradients. The transient thermal test setup and results are described in this report.

36 MATERIALS SCIENCE↗

Agricultural scene understanding

The author has identified the following significant results. The LACIE field measurement data were radiometrically calibrated. Calibration enabled valid comparisons of measurements from different dates, sensors, and/or locations. Thermal band canopy results included: (1) Wind velocity had a significant influence on the overhead radiance temperature and the effect was quantized. Biomass and soil temperatures, temperature gradient, and canopy geometry were altered. (2) Temperature gradient was a function of wind velocity. (3) Temperature gradient of the wheat canopy was relatively constant during the day. (4) The laser technique provided good quality geometric characterization.

Landgrebe, D. A.↗

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation and Exploration of Parameterizations of Large-Scale Dynamics in NCAR's Single Column Atmosphere Model SCAM6

A single column model with parameterized large-scale (LS) dynamics is used to better understand the response of steady-state tropical precipitation to relative sea surface temperature under various representations of radiation, convection, and circulation. The large-scale dynamics are parametrized via the weak temperature gradient (WTG), damped gravity wave (DGW), and spectral weak temperature gradient (Spectral WTG) method in NCAR's Single Column Atmosphere Model (SCAM6). Radiative cooling is either specified or interactive, and the convective parameterization is run using two different values of a parameter that controls the degree of convective inhibition. Results are interpreted in the context of the Global Atmospheric System Studies -Weak Temperature Gradient (GASS-WTG) Intercomparison project. Using the same parameter settings and simulation configuration as in the GASS-WTG Intercomparison project, SCAM6 under the WTG and DGW methods produces erratic results, suggestive of numerical instability. However, when key parameters are changed to weaken the large-scale circulation's damping of tropospheric temperature variations, SCAM6 performs comparably to single column models in the GASS-WTG Intercomparison project. The Spectral WTG method is less sensitive to changes in convection and radiation than are the other two methods, performing qualitatively similarly across all configurations considered. Under all three methods, circulation strength, represented in 1D by grid-scale vertical velocity, is decreased when barriers to convection are reduced. This effect is most extreme under specified radiative cooling, and is shown to come from increased static stability in the column's reference radiative-convective equilibrium profile. This argument can be extended to interactive radiation cases as well, though perhaps less conclusively.

54 ENVIRONMENTAL SCIENCES↗

Radial gradients of ion densities and temperatures observed by SWICS/Ulysses

Mean density and temperature gradients of solar wind protons and alpha-particles between 1 and 5.4 AU are established from SWICS/Ulysses observations. All parameters are classified in speed intervals. au order scheme giving us a natural extension of the Helios observations. which were usually classified according to speed of the wind. The radial gradients show a similar behaviour of both particle species, while the particles radially propagate and thereby cool off in the heliosphere. The slow solar wind is found, for protons as well as a particles. to expand adiabatically all the way out to 5.4 AU, while the fast wind evolves non-adiabatically and is heated by interplanetary sources. It, seems that the heating rate of the a-particles is larger than the heating rate of the protons. The ion temperature ratio and density ratio are determined. They do not indicate any radial dependence. The temperature ratio T(sub alpha)/T(sub p) is on average about 4. It has a maximum of 4.5 in the velocity interval where 400 km/s is less than v(sub p) is less than 500 km/s, while in slow wind with v(sub p) is less than 400 km/s it has a minimum value of 37. and for fast wind with v(sub p) is greater than 500 km/s it is 3.9. The density gradients shows compression effects resulting from fast wind overtaking the slow wind.

Liu, S.↗

Thermal Field Imaging Using Ultrasound

It is often desirable to be able to determine the temperature field in the interiors of opaque fluids forced into convection by externally imposed temperature gradients. To measure the temperature at a point in an opaque fluid in the usual fashion requires insertion of a probe, and to determine the full field therefore requires either the ability to move this probe or the introduction of multiple probes. Neither of these solutions is particularly satisfactory, although they can lead to quite accurate measurements. As an alternative we have investigated the use of ultrasound as a relatively non-intrusive probe of the temperature field in convecting opaque fluids. The temperature dependence of the sound velocity can be sufficiently great to permit a determination of the temperature from timing the traversal of an ultrasound pulse across a chamber. In this paper we will present our results on convecting flows of transparent and opaque fluids. Our experimental cells consist of relatively narrow rectangular cavities made of thermally insulating materials on the sides, and metal top and bottom plates. The ultrasound transducer is powered by a pulser/receiver, the signal output of which goes to a very high speed signal averager. The average of several hundred to several thousand signals is then sent to a computer for storage and analysis. The experimental procedure is to establish a convective flow by imposing a vertical temperature gradient on the chamber, and then to measure, at several regularly spaced locations, the transit time for an ultrasound pulse to traverse the chamber horizontally (parallel to the convecting rolls) and return to the transducer. The transit time is related to the temperature of the fluid through which the sound pulse travels. Knowing the relationship between transit time and temperature (determined in a separate experiment), we can extract the average temperature across the chamber at that location. By changing the location of the transducer it is then possible to find the average temperature at different locations along the chamber, thereby determining the temperature profile along the system. (In the future we will construct an array of transducers. This will give us the capability to determine the temperature profile much more rapidly than at present, an important consideration if time-dependent phenomena are to be studied.) To validate our procedure we introduced encapsulated liquid crystal particles into glycerol. The liquid crystal particles' color varies depending on the temperature of the fluid. A photograph of the fluid through transparent sidewalls therefore gives a picture of the temperature field of the convecting fluid, independent of our ultrasound imaging. A representative result is shown in the Figure 1, which reveals a very satisfying correspondence between the two techniques. Therefore we have a great deal of confidence that the ultrasound imaging approach is indeed measuring the actual temperature profile of the fluid. The technique has also been applied to convecting liquid metal flows, and representative data will be presented from those experiments as well.

Andereck, D.↗

Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series

Abstract. Improving the quantification of soil thermal and physical properties is key to achieving a better understanding and prediction of soil hydro-biogeochemical processes and their responses to changes in atmospheric forcing. Obtaining such information at numerous locations and/or over time with conventional soil sampling is challenging. The increasing availability of low-cost, vertically resolved temperature sensor arrays offers promise for improving the estimation of soil thermal properties from temperature time series, and the possible indirect estimation of physical properties. Still, the reliability and limitations of such an approach need to be assessed. In the present study, we develop a parameter estimation approach based on a combination of thermal modeling, sliding time windows, Bayesian inference, and Markov chain Monte Carlo simulation to estimate thermal diffusivity and its uncertainty over time, at numerous locations and at an unprecedented vertical spatial resolution (i.e., down to 5 to 10 cm vertical resolution) from soil temperature time series. We provide the necessary framework to assess under which environmental conditions (soil temperature gradient, fluctuations, and trend), temperature sensor characteristics (bias and level of noise), and deployment geometries (sensor number and position) soil thermal diffusivity can be reliably inferred. We validate the method with synthetic experiments and field studies. The synthetic experiments show that in the presence of median diurnal fluctuations ≥ 1.5 ∘C at 5 cm below the ground surface, temperature gradients > 2 ∘C m−1, and a sliding time window of at least 4 d the proposed method provides reliable depth-resolved thermal diffusivity estimates with percentage errors ≤ 10 % and posterior relative standard deviations ≤ 5 % up to 1 m depth. Reliable thermal diffusivity under such environmental conditions also requires temperature sensors to be spaced precisely (with accuracy to a few millimeters), with a level of noise ≤ 0.02 ∘C, and with a bias defined by a standard deviation ≤ 0.01 ∘C. Finally, the application of the developed approach to field data indicates significant repeatability in results and similarity with independent measurements, as well as promise in using a sliding time window to estimate temporal changes in soil thermal diffusivity, as needed to potentially capture changes in bulk density or water content.

54 ENVIRONMENTAL SCIENCES↗

Reflected shock-initiated ignition probed via simultaneous lateral and endwall high-speed imaging with a transparent, cylindrical test-section

A TRAnsparent cylindrical (TRAC) shock tube test section has been developed to explore the ignition structure behind reflected shockwaves via simultaneous lateral and endwall high-speed imaging using three fuel/oxidizer mixtures: 0.1% n-C 7 H 16 /1.10% O 2 /4.14% N 2 /94.66% Ar, 0.1% iC 8 H 18 /1.25% O 2 /4.69% N 2 /93.96% Ar, and 5% CH 4 /10% O 2 /85% CO 2 . During mild ignition, the first exothermic centers were located outside of the observable test section. It is shown that with increasing temperature the far-wall ignition events move closer to the endwall, until a strong ignition is achieved. The temperature gradients that promote mild ignition were quantified and were found to have a slight dependence on fuel with the RMS temperature gradients being 0.80% for n-heptane and 1.07% for isooctane. The impact of temperature gradients on metrics used to improve kinetic models, such as species time histories, is noteworthy. From this temperature gradient, an experimental correlation is provided to estimate the transition temperature from mild to strong ignition for a mixture. The effect of diagnostic location in non-homogeneous reactions is quantified in reference to ignition delay. In conclusion, the unique and insightful perspective on the ignition process under heavy shock bifurcation is also discussed.

02 PETROLEUM↗

Evaluation and development of surface layer scheme representation of temperature inversions over boreal forests in Arctic wintertime conditions

Abstract. In this study, the Noah land surface model used in conjunction with the Mellor–Yamada–Janjić surface layer scheme (hereafter, Noah-MYJ) and the Noah multiphysics scheme (Noah-MP) from the Weather Research and Forecasting (WRF) 4.5.1 mesoscale model are evaluated with regard to their performance in reproducing positive temperature gradients over forested areas in the Arctic winter. First, simplified versions of the WRF schemes, recoded in Python, are compared with conceptual models of the surface layer in order to gain insight into the dependence of the temperature gradient on the wind speed at the top of the surface layer. It is shown that the WRF schemes place strong limits on the turbulent collapse, leading to lower surface temperature gradient at low wind speeds than in the conceptual models. We implemented modifications to the WRF schemes to correct this effect. The original and modified versions of Noah-MYJ and Noah-MP are then evaluated compared to long-term measurements at the Ameriflux Poker Flat Research Range, a forest site in interior Alaska. Noah-MP is found to perform better than Noah-MYJ because the former is a two-layer model which explicitly takes into account the effect of the forest canopy. Indeed, a non-negligible temperature gradient is maintained below the canopy at high wind speeds, leading to overall larger gradients than in the absence of vegetation. Furthermore, the modified versions are found to perform better than the original versions of each scheme because they better reproduce strong temperature gradients at low wind speeds.

Geology↗

Determination of the hydrogen heat of transport in Zircaloy-4

During operation in a nuclear reactor, Zr-based nuclear fuel cladding is subject to waterside corrosion which can lead to hydrogen ingress. Here, the hydrogen that enters the material will migrate to colder spots and precipitate as zirconium hydrides if the hydrogen content exceeds the hydrogen terminal solid solubility in the material. Since a temperature gradient is established in the radial direction of the cladding during operation, the hydrides can preferentially precipitate at the colder outer surface of the cladding. Other gradients can also occur in the longitudinal and azimuthal directions of the cladding tube. As a consequence, hydrogen redistributes itself in response to the concentration and temperature gradients present in the sample. The response of the hydrogen in solid solution to temperature gradients is governed by the heat of transport Q* as a function of temperature, so it can be used in the BISON code. A set of experiments was set up to determine the heat of transport (Q*), in which a uniformly hydrided Zircaloy-4 sample is annealed under a fixed temperature gradient at a range of temperatures, and the resulting hydrogen distribution is analyzed to determine Q*. The results are discussed in terms of existing literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗