Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

AGTR1 blocker attenuates activation of Tenon's capsule fibroblasts after glaucoma filtration surgery via the NF-κB signaling pathway

Activation of Tenon's capsule fibroblasts limits the success rate of glaucoma filtration surgery (GFS), the most efficacious therapy for patients with glaucoma. Angiotensin type 1 receptor (AGTR1) is involved in tissues remodeling and fibrogenesis. However, whether AGTR1 is involved in the progress of fibrogenesis after GFS is not fully elucidated. The aim of this study was to investigate the role of an AGTR1 in scar formation after GFS and the potential anti-fibrosis effect of AGTR1 blocker. AGTR1 expression level was increased in subconjunctival tissues in a rat model of GFS and transforming growth factor-beta 2 (TGF-β2)-induced human Tenon's capsule fibroblasts (HTFs). AGTR1 blocker treatment suppressed TGF-β2-induced HTF migration and α-smooth muscle actin (α-SMA) and fibronectin (FN) expression. AGTR1 blocker treatment also attenuated collagen deposition and α-SMA and FN expression in subconjunctival tissues of the rat model after GFS. Moreover, AGTR1 blocker decreased TGF-β2-induced P65 phosphorylation, P65 nuclear translocation, and nuclear factor kappa B (NF-κB) luciferase activity. Additionally, BAY 11–7082 (an NF-κB inhibitor) significantly suppressed HTF fibrosis. In conclusion, our results indicate that AGTR1 is involved in scar formation after GFS. The AGTR1 blocker attenuates subconjunctival fibrosis after GFS by inhibiting the NF-κB signaling pathway. These findings indicate that targeting AGTR1 is a potential approach to attenuate fibrosis after GFS.

60 APPLIED LIFE SCIENCES↗

Ion irradiation in liquid of {mu}m{sup 3} region for cell surgery

We present here a cell surgery scheme involving selective inactivation or disruption of cellular structures. Energetic ions are injected into a cell through a tapered glass capillary like a microinjection method. A slight but essential difference from microinjection is that a thin window is prepared at the outlet so that no liquid material can flow in or back through the outlet while still allowing energetic ions to penetrate into the cell. An {approx}MeV He ion beam from such a capillary having 10 {mu}m outlet diameter inactivated a selected volume ({approx}{mu}m{sup 3}) of fluorescent molecules located in a HeLa cell nucleus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focused Ultrasound Surgery Control Using Local Harmonic Motion: VX2 Tumor Study

The objective of this study was to develop a real-time method for controlling focused ultrasound surgery using ultrasound imaging. The approach uses measurements of localized harmonic motion (LHM) in order to perform controlled FUS exposures by detecting changes in the elastic properties of tissues during coagulation. Methods: Nine New Zealand rabbits with VX2 tumors implanted in the thigh were used for this study. LHM was generated within the tumors by periodic induction of radiation force using a FUS transducer (80-mm focal length, 100-mm diameter, 20-mm central hole, 1.485-MHz). Tissue motion was tracked by collecting and cross-correlating RF signals during the motion using a separate diagnostic transducer (3-kHz PRF, 5-MHz). After locating the tumor in MR images, a series of sonications were performed to treat the tumors using a reduction in LHM amplitude to control the exposure. Results: LHM was successfully used to control the sonications. A LHM amplitude threshold value was determined at which changes were considered significant and then the exposure was started and stopped when the LHM amplitude dropped below the threshold. The appearance of a lesion was then verified by MRI. The feasibility of LHM measurements to control FUS exposure was validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simulation Model for Local Harmonic Motion Monitoring of Focused Ultrasound Surgery

A computational model for local harmonic motion (LHM) imaging-based monitoring of high-intensity focused ultrasound surgery (FUS) is presented. LMH technique is based on a focused ultrasound radiation force excitation, which induces local mechanical vibrations at the focal region. These pulse-echo imaged vibrations are then used to estimate the mechanical properties of the sonication region. LHM has been proven to be feasible for FUS monitoring because changes in the material properties during the coagulation affect the measured displacements. The presented model includes separate models to simulate acoustic fields, sonication induced temperature elevation and mechanical vibrations, and pulse-echo imaging of the induced motions. These simulation models are based on Rayleigh integral, finite element, and spatial impulse response methods. Simulated temperature rise and vibration amplitudes have been compared with in vivo rabbit experiments with noninvasive MRI thermometry.

60 APPLIED LIFE SCIENCES↗

Using endografts from superelastic titanium-nickelid-based alloy singular tissue plural tissues in organ-preserving surgery of laryngeal cancer

Our study has demonstrated feasibility of performing larynx preservation surgeries in patients with recurrent laryngeal cancer after failure of radiotherapy. The technique of combined laryngeal reconstruction with endografts from superelastic titanium-nickelid-based alloy Singular tissue Plural tissues results in improvement of life quality by preserving laryngeal functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental and theoretical study of the heating dynamics of carbon-containing optothermal fibre converters for laser surgery

We have studied carbon-containing optothermal fibre converters (COTFCs) that are located on the distal end of a quartz – quartz optical fibre for delivering laser radiation in medical laser surgery systems and differ in the thickness and structure of the layer of a material converting laser radiation into heat. The heating dynamics of 'thin-film' and '3D' converters have been investigated at average incident 980-nm semiconductor laser beam powers of 0.3, 1.0 and 4.0 W, with the converters placed freely in air. The results demonstrate that, before the instant of disintegration, the efficiency of laser heating of the converter surface can reach 3000 °C W{sup -1} for thin-film converters, 1000 °C W{sup -1} for spherical 3D converters and 55 °C W{sup -1} for planar 3D converters. The thin-film converter breaks down at an average laser beam power as low as 0.30 ± 0.05 W, which is accompanied by a considerable reduction in heating efficiency and is caused by the disintegration of the carbon film on its surface. The spherical 3D converter breaks down at an average power of 4.0 ± 0.1 W, as a result of the disintegration of the carbon film on its surface and partial melting of a modified layer containing microbubbles. The carbon film on the surface of the planar 3D converter also disintegrates at an average power of 4.0 ± 0.1 W, but the structure of the modified layer remains unchanged. We have constructed structural and optophysical models of the converters by simulating light absorption in carbon films on the surface of the COTFC and inside the microbubbles present in the modified layer of the converters. The proposed models of the COTFCs have been shown to adequately describe real converters. (laser biophotonics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond-Laser-Induced Nanocavitation in Water: Implications for Optical Breakdown Threshold and Cell Surgery

We determined the bubble radius R{sub max} for femtosecond optical breakdown in water at 347, 520, and 1040 nm with an unprecedented accuracy ({+-}10 nm). At threshold, R{sub max} was smaller than the diffraction-limited focus radius and ranged from 190 nm to 320 nm. The increase of R{sub max} with laser energy E{sub L} is slowest at 347 nm, providing optimum control of cell surgery. Experimental results agree with a model of bubble formation in heated and thermoelastically stretched liquids. Theory predicts a threshold temperature T{sub th}{approx_equal}168 deg. C. For T>300 deg. C, a phase explosion sets in, and R{sub max} increases rapidly with E{sub L}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MR-guided focused ultrasound surgery, present and future

MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20/20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-33: Critical Role of T2-Weighted Imaging Combined with Diffusion-Weighted Imaging of MRI in Diagnosis of Loco-Regional Recurrent Esophageal Cancer After Radical Surgery

Purpose: We perform this study to investigate the diagnostic efficacy of T2-weighted MRI (T2WI) and diffusion-weighted MRI (DWI) in confirming local relapses of esophageal cancer in patients highly suspected of recurrence after eradicating surgery. Methods: Forty-two postoperative esophageal cancer patients with clinical suspicions of cancer recurrence underwent 3.0T MRI applying axial, coronal, sagittal T2WI and axial DWI sequences. Two experienced radiologists (R1 and R2) both used two methods (T2WI, T2WI+DWI) to observe the images, and graded the patients ranging from 1 to 5 to represent severity of the disease based on visual signal intensity (patients equal to or more than grade 3 was confirmed as recurrent disease) Results: 27/42patients were verified of recurrent disease by pathologic findings and/or imaging findings during follow-up. The sensitivity, specificity and accuracy of R1 applying T2WI+DWI are 96%, 87% and 93% versus 81%, 80% and 77% on T2WI, these figures by R2 were 96%, 93% and 95% versus 89%, 93% and 90%. The receiver operating curve (ROC) analyses suggest that both of the two readers can obtain better accuracy when adding DWI to T2WI compared with T2WI alone. Kappa test between R1 and R2 indicates excellent inter-observer agreement on T2WI+DWI. Conclusion: Standard T2WI in combination DWI can achieve better accuracy than T2WI alone in diagnosing local recurrence of esophageal cancer, and improve consistency between different readers.

60 APPLIED LIFE SCIENCES↗

SU-E-T-327: Dosimetric Impact of Beam Energy for Intrabeam Breast IORT with Different Residual Cancer Cell Distributions After Surgery

Purpose: The purpose of this study was to evaluate the dosimetric impact of beam energy to the IORT treatment of residual cancer cells with different cancer cell distributions after breast-conserving surgery. Methods: The three dimensional (3D) radiation doses of IORT using a 4-cm spherical applicator at the energy of 40 keV and 50 keV were separately calculated at different depths of the postsurgical tumor bed. The modified linear quadratic model (MLQ) was used to estimate the radiobiological response of the tumor cells assuming different radio-sensitivities and density distributions. The impact of radiation was evaluated for two types of breast cancer cell lines (α /β=10, and α /β =3.8) at 20 Gy dose prescribed at the applicator surface. Cancer cell distributions in the postsurgical tissue field were assumed to be a Gaussian with the standard deviations of 0.5, 1 and 2 mm respectively, namely the cancer cell infiltrations of 1.5, 3, and 6 mm respectively. The surface cancer cell percentage was assumed to be 0.01%, 0.1%, 1% and 10% separately. The equivalent uniform doses (EUD) for all the scenarios were calculated. Results: The EUDs were found to be dependent on the distributions of cancer cells, but independent of the cancer cell radio-sensitivities and the density at the surface. EUDs of 50 keV are 1% larger than that of 40 keV. For a prescription dose of 20 Gy, EUDs of 50 keV beam are 17.52, 16.21 and 13.14 Gy respectively for 0.5, 1.0 and 2.0 mm of the standard deviation of cancer cell Gaussian distributions. Conclusion: The impact by selected energies of IORT beams is very minimal. When energy is changed from 50 keV to 40 keV, the EUDs are almost the same for the same cancer cell distribution. 40 keV can be safely used as an alternative of 50 keV beam in IORT.

60 APPLIED LIFE SCIENCES↗

Laterally Extended Pelvic Resection for Gynaecological Malignancies: A Multicentric Experience with Out-of-the-Box Surgery

Purpose: To evaluate morbidity and oncological outcome in a multicentre series of women with gynaecological malignancies infiltrating pelvic side wall (PSW) that received laterally extended pelvic resection (LEPR). Methods: Patients operated between 2007 and 2017 at three institutions were included. LEPR was defined as an en bloc lateral resection of a pelvic tumour involving sidewall muscle, and/or bone, and/or major nerve, and/or major vascular structure. Postsurgical complications and survivals were evaluated. Results: Sixty-three women with gynaecological tumours involving PSW were treated with LEPR. Five women underwent primary LEPR, whereas 58 (92%) patients needed LEPR because of recurrence. Twenty-four women (38%) received previous radiation therapy before the surgery. R0 resection was achieved in 54 patients (85.7%), whereas the pathologic margins were microscopically and macroscopically positive in 8 (12.7%) patients and 1 (1.6%) patient, respectively. There was one perioperative death, whereas major postoperative complications occurred in 17 patients (27.7%). Thirty (47.5%) women experienced recurrences: 24/54 (44.4%) were in the R0 group, and 6/9 (66.6%) were in the R1 group, with a median PFS of 15 months and 7 months, respectively (p = 0.024). In total, 11 of 54 (20.3%) patients died of disease in the R0 group and 5 of 9 (55.5%) in the R1 group; a median OS was not reached and was 32 months for R0 and R1 groups, respectively (p = 0.033). Conclusions: Involvement of the PSW should not prevent obtaining R0 resection. Although the LEPR is associated with considerable morbidity (≈ 30%), a long-term survival seems to be achieved in those women with complete resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy After Breast-Conserving Surgery in Women 70 Years of Age and Older: How Wisely Do We Choose?

Background: Despite data from randomized trials supporting omission of radiation therapy (RT) for women ≥ 70 years of age with T1, estrogen receptor-positive (ER+) tumors undergoing breast-conserving therapy (BCT), RT usage remains high. We reviewed our institutional experience to determine if risk factors for local recurrence or comorbidities influenced use. Methods: Women ≥ 70 years of age with T1, ER+, human epidermal growth factor receptor 2-negative (HER2−) tumors undergoing BCT in 2010–2012 were identified from a prospectively maintained database. Ten-year estimated mortality was calculated using the Suemoto index. The associations of clinicopathological features and mortality risk on receipt of RT were examined. Results: Overall, 323 patients with 327 cancers were identified. Median age was 75 years, median tumor size was 1 cm, and all were clinically node negative; 53.7% of patients received RT. RT usage decreased with age (73.6%, age 70–74 years; 49.5%, age 75–79 years; 33.3%, age 80–84 years; 10.7%, ≥ 85 years; p < 0.001). Within age groups, estimated mortality did not impact RT usage. On multivariable analysis, only younger age and larger tumor size were associated with RT use. Recurrence-free survival was 98% versus 93% with and without RT, respectively (p = 0.011). Those who received adjuvant radiation also had improved overall survival (92% vs. 89%), although this effect did not reach statistical significance (p = 0.051). Conclusion: Neither the factors associated with risk of local recurrence nor the estimated risk of death in 10 years were associated with use of adjuvant radiation in a large cohort of women ≥ 70 years of age with small ER+ breast cancers treated with breast-conserving surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital Breast Tomosynthesis for Intraoperative Margin Assessment during Breast-Conserving Surgery

Background: Intraoperative margin assessment for breast cancer patients undergoing segmental mastectomy (SM) enables identification of positive margins, with immediate excision of additional tissue to obtain negative margins. Objective: The aim of this study was to determine the ability of digital breast tomosynthesis (DBT) to detect positive margins compared with an institution’s standard extensive processing (SEP). Methods: SM specimens underwent intraoperative SEP with two-dimensional (2D) imaging of the intact and sliced specimen, with review by a breast radiologist and gross assessment by a breast pathologist. Findings guided the surgeon to excise additional tissue. DBT images of intact specimens were prospectively obtained and retrospectively reviewed by a breast radiologist. A positive margin was defined as tumor at ink. Results: Ninety-eight patients underwent 99 SMs. With SEP, 14 (14%) SM specimens had 19 positive margins. SEP did not detect 3 of the 19 positive margins, for a sensitivity of 84%, specificity of 78%, positive predictive value (PPV) of 11%, and negative predictive value (NPV) of 99%. Moreover, DBT did not detect 5 of the 19 positive margins, for a sensitivity of 74% (p > 0.05), specificity of 91% (p < 0.05), PPV of 21.5%, and NPV of 99%. With SEP guidance to excise additional tissue, six cases had final positive margins, with SEP not identifying three of these cases and DBT not identifying two. Pathology from the second surgery of these patients showed either no additional malignancy or only focal ductal carcinoma in situ. Conclusions: DBT is an accurate method for detecting positive margins in breast cancer patients undergoing SM, performing similar to institutional labor-intensive, intraoperative standard processing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neoadjuvant Chemotherapy with Gemcitabine Plus Nab-Paclitaxel for Borderline Resectable Pancreatic Cancer Potentially Improves Survival and Facilitates Surgery

Background: Accumulation of evidence suggests that neoadjuvant chemotherapy improves the outcomes of borderline resectable pancreatic cancer (BRPC). Gemcitabine plus nab-paclitaxel (GnP) has been widely accepted as systemic chemotherapy for unresectable pancreatic cancer and reportedly results in remarkable tumor shrinkage. This study was performed to evaluate the safety and efficacy of neoadjuvant chemotherapy using neoadjuvant GnP for BRPC. Methods: The medical records of 57 patients who underwent treatment of BRPC from 2010 to 2017 were retrospectively reviewed. The patient characteristics and short- and intermediate-term outcomes were compared between the GnP and upfront surgery (UFS) groups. Results: The GnP group comprised 31 patients and the UFS group comprised 26 patients. The patient characteristics were comparable with the exception of a higher prevalence of arterial involvement in the GnP group. Twenty-seven of the 31 patients (87%) in the GnP group and all 26 patients in the UFS group underwent resection. The GnP group showed a significantly shorter operation time (429 vs. 509.5 min, p = 0.0068), less blood loss (760 vs. 1324 ml, p = 0.0115), and a higher R0 resection rate (100% vs. 77%, p = 0.0100) than the UFS group. Postoperative complications and hospital stay were comparable between the two groups, and no treatment-related mortality occurred in either group. Both the disease-free survival and overall survival times were significantly longer in the GnP group (p = 0.0018 and p = 0.0024, respectively). Conclusions: Neoadjuvant GnP is a safe and effective treatment strategy for BRPC. It potentially improves patients’ prognosis and facilitates surgical procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inpatient Opioid Use After Pancreatectomy: Opportunities for Reducing Initial Opioid Exposure in Cancer Surgery Patients

Background: Despite advances in enhanced surgical recovery programs, strategies limiting postoperative inpatient opioid exposure have not been optimized for pancreatic surgery. The primary aims of this study were to analyze the magnitude and variations in post-pancreatectomy opioid administration and to characterize predictors of low and high inpatient use. Methods: Clinical characteristics and inpatient oral morphine equivalents (OMEs) were downloaded from electronic records for consecutive pancreatectomy patients at a high-volume institution between March 2016 and August 2017. Regression analyses identified predictors of total OMEs as well as highest and lowest quartiles. Results: Pancreatectomy was performed for 158 patients (73% pancreaticoduodenectomy). Transversus abdominus plane (TAP) block was performed for 80% (n = 127) of these patients, almost always paired with intravenous patient-controlled analgesia (IV-PCA), whereas 15% received epidural alone. All the patients received scheduled non-opioid analgesics (median, 2). The median total OME administered was 423 mg (range 0–4362 mg). Higher total OME was associated with preoperative opioid prescriptions (p < 0.001), longer hospital length of stay (LOS; p < 0.001), and no epidural (p = 0.006). The lowest and best quartile cutoff was 180 mg of OME or less, whereas the highest and worst quartile cutoff began at 892.5 mg. After adjustment for inpatient team, only epidural use [odds ratio (OR) 0.3; p = 0.04] predicted lowest-quartile OME. Preoperative opioid prescriptions (OR 8.1; p < 0.001), longer operative time (OR 3.4; p = 0.05), and longer LOS (OR 1.1; p = 0.007) predicted highest-quartile OME. Conclusions: Preoperative opioid prescriptions and longer LOS were associated with increased inpatient OME, whereas epidural use reduced inpatient OME. Understanding the predictors of inpatient opioid use and the variables predicting the lowest and highest quartiles can inform decision-making regarding preoperative counseling, regional anesthetic block choice, and novel inpatient opioid weaning strategies to reduce initial postoperative opioid exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Saving the Male Breast: A Systematic Literature Review of Breast-Conservation Surgery for Male Breast Cancer

Background: Male breast cancer (MBC) management is extrapolated from female BC. Mastectomy remains the most frequently used surgical procedure for male breast cancer (MBC). We performed a literature review to assess the use of breast-conservation (BCS) in MBC as well as outcomes following BCS. Methods: A systematic literature was performed, and articles screened to identify studies that measured overall survival (OS), disease-free survival (DFS), or local recurrence (LR) in patients undergoing BCS. Weighted averages based on study size were performed for LR, DFS, and 5-year OS. Results: Eight studies met the inclusion criteria with male breast surgery cases, and 859 (14.7%) underwent BCS. The mean follow-up time was 53 months, and mean age was 62.6 years, with stage II as the most common presentation. Two studies reported that 50–71.4% of patients underwent sentinel lymph node biopsy, and four studies reported axillary lymph node dissection in 14.3–100%. Five studies reported on adjuvant radiation therapy in 12.0–100% of total patients undergoing BCS. Four studies reported use of hormonal therapy in 73.8–100% of patients. Four studies reported use of chemotherapy in 25–66.7% of patients. Seven studies reported LR among 116 patients, with a weighted average of 9.9%. Three studies reported on DFS in 14 patients, with a weighted average 85.6%. Two studies report OS in 143 patients with a weighted average of 84.4%. Conclusions: Breast conservation may be considered a safe alternative in the surgical treatment of MBC. Future research should focus on better standardization of local therapy for MBC and improved reporting of outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Update on the Feasibility and Progress on Robotic Breast Surgery

Background: Robotic nipple-sparing mastectomy (RNSM) may allow for more precise anatomic dissection and improved cosmetic outcomes over conventional open nipple-sparing mastectomy; however, data regarding the feasibility and safety of the procedure are limited. Objective: The aim of this study was to present and discuss perioperative surgical outcomes and early oncologic follow-up data on consecutive patients undergoing RNSM from June 2014 to January 2019. Methods: Patients underwent RNSM and immediate robotic breast reconstruction through an axillary incision at a single institution. Perioperative data, complications at 3 months postoperatively, pathological data, and adjuvant therapies were recorded. Local recurrence-free, disease-free, and overall survival were analyzed. Results: Overall, 73 women underwent 94 RNSM procedures. Indications were invasive breast cancer in 39 patients, ductal carcinoma in situ in 17 patients, and BRCA mutation in 17 patients. Mean surgery time was 3 h and 32 min. One-step reconstruction with implant occurred in 89.4% of procedures. The rate of complications requiring reoperation was 4.3%, and the rate of flap or nipple necrosis was 1.1%. Median follow-up was 19 months (range 3.1–44.8). No local recurrences occurred. Overall survival at 12, 24, or 60 months was 98% (95% confidence interval 86–100%). Conclusion: We observed a low complication rate in 94 consecutive RNSM procedures, demonstrating the procedure is technically feasible and safe. We found no early local failures at 19 months follow-up. Long-term follow-up is needed to confirm oncologic safety. Future clinical trials to study the advantages and disadvantages of RNSM are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗