Lunar Surface Thermal Analysis Roadmap
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The residual tensile strength of a thick graphite/epoxy composite with impact damage was predicted using surface crack analysis. The damage was localized to a region directly beneath the impact site and extended only part way through the laminate. The damaged region contained broken fibers, and the locus of breaks in each layer resembled a crack perpendicular to the direction of the fibers. In some cases, the impacts broke fibers without making a visible crater. The impact damage was represented as a semi-elliptical surface crack with length and depth equal to that of the impact damage. The maximum length and depth of the damage were predicted with a stress analysis and a maximum shear stress criterion. The predictions and measurements of strength were in good agreement.
Process control has been proven to be the most reliable means of safeguarding the quality of adhesive bonds according to Federal Aviation Administration (FAA). A method for implementing process control for reduction in risk in a bonded joint fabrication process is demonstrated in this study using a selected bonding system. The stepwise method included risk analysis to identify defects with the highest impact and likelihood to occur, evaluation of various pre-bond surface analysis tools to monitor for the selected defects, and demonstration of the benefits of in-process monitoring utilizing threshold limits determined from bond performance tests. The bonded system selected for investigation was an aerospace carbon fiber epoxy composite substrate surface prepared with random orbital sanding using 180 grit aluminum oxide sand paper. A series of portable, pre-bond surface analysis tools were investigated for their ability to be used for in-line bond process control. Results and threshold limits are presented from roughness, ballistic water contact angle (WCA), color, gloss, and Fourier transform infrared spectroscopy (FTIR) surface analysis tools. Results demonstrated how in-process inspection methods can be used to ensure quality of a surface preparation for a selected bonding system. A framework is provided for implementation of bond process control for robust bonding.
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique surface analysis technique because it can provide molecular recognition for organic and biological molecules. However, analyzing aqueous solution surfaces by ToF-SIMS is difficult, because ToF-SIMS is a high-vacuum technique, while the vapor pressure of water is about 2.3 kPa at room temperature (20 C). We designed and fabricated a self-contained microfluidic device, enabling in situ analysis of aqueous surfaces by scanning electron microscope (SEM) and ToF-SIMS, which has been briefly reported.1,2 In this study, we report more performance data, focusing on the performance of this device for in situ analysis of organic molecules at aqueous surfaces using ToF-SIMS. Three representative organic compounds (formic acid, glycerol, and glutamic acid) were tested, and their molecular signals were successfully observed. The device can be self-running in vacuum for 8 hours, and SIMS measurements are feasible at any time in this time range. The stability of this device under primary ion beam bombardment is also impressive. High fluence (6 × 1012 ions cm-2 s-1) measurements can be operated continuously for up to 30 minutes without any significant damage to the aperture. However, extra-high fluence measurements (>1 × 1014 ions cm-2 s-1) may lead to liquid bumping in the aperture, and the aqueous solutions may spread out quickly. Signal reproducibility is reasonably good, and relative standard deviation (RSD) for molecular ion signals can be controlled to be smaller than ±15% for consecutive measurements. Measurements at long time intervals (e.g., 60 min) show RSDs of ±40-50%. In addition, the detection limits of formic acid, glycerol, and glutamic acid are estimated to be 0.04%, 0.008%, and 0.002% (weight ratio), respectively.
The international ISO Standard 20579-4, dealing with the history and preparation of nano-objects for surface analysis, has been developed to help address some of the replication and reproducibility issues caused by the fundamental nature of nano-objects. Although all types of samples requiring surface analysis need thoughtful preparation, nano-objects, for which many properties are controlled by their surfaces, present additional challenges in order to avoid variations and artefacts due to the handling and preparation of materials prior to analysis. This international standard is part of a series of standards related to preparation of samples for surface chemical analysis. Parts 1 and 2 of ISO Standard series 20579 address general issues that apply to many samples. Part 4 specifically considers issues that arise due to the inherent nature of nano-objects. Because of sensitivity to their environment, the standard indicates the minimum information that needs to be reported about the handling and preparation of nano-objects prior to surface analysis. This information should become part of sample provenance information that helps assure the reliability and usefulness of data obtained from surface-analysis in the context of the synthesis, processing and analysis history of a batch of material. Application of this standard can help address reproducibility and traceability issues associated with synthesis, processing, and characterization of nano-objects in research and commercial applications.
ZnO is a wide-gap oxide semiconductor of considerable current interest for electronics, optoelectronics, and, possibly, semiconductor spintronics. Through selective electronic doping, ZnO can be a transparent conducting oxide [1], a UV light emitter [2,3], and, when alloyed with a few to several atomic percent of Co, Mn or other transition metals with unpaired d electrons, is squarely at the center of controversy in the field of high-Tc ferromagnetic semiconductors [4]. Despite this range of interests, fundamental aspects of electronic doping in ZnO remain poorly understood. For instance, theoretical calculations suggest that H at either interstitial or substitutional sites is responsible for the persistent n-type conductivity that frustrates efforts to achieve p-type behavior, an essential requirement for the fabrication of pn light emitting diodes and hole-mediated ferromagnetic coupling of Mn dopants [5,6]. Yet, experimental studies do not in general align with this prediction. Another interesting aspect of n-type conduction in ZnO is the appearance of a near-surface conducting channel that appears to be present in bulk crystals [7,8]. Although it has been a few years since the original observation of this phenomenon was described, detailed understanding is lacking. In this paper, David Look presents a transport study aimed at gaining insight into the phenomenon of near-surface conductivity in bulk ZnO. All samples investigated were unintentionally n-type, as is typical. The measured Hall data were interpreted using a two-layer conduction model based on standard charge balance equations. Look fit the temperature dependence of the electron mobility and carrier concentration and extracted the thicknesses of the surface conducting layer, which dominates at lower temperatures, for bulk crystals synthesized by different methods and marketed by different companies. By making reasonable assumptions about the surface acceptor density, the lower limit of the surface conducting layer thickness was extracted from the transport data. From a surface science perspective, two aspects of the investigation are of particular interest: (i) the donor concentration was enhanced by annealing in forming gas, which is 5% H2, and, (ii) despite relatively weak variation in the sheet carrier concentration, the surface conducting layer thickness (dsurf) varied from as large as 28 nm to as small as 1.5 nm, depending on the method of preparation and supplier. The ongoing exploration of this phenomenon begs for the kind of experiments that practitioners of surface, interface and thin-film science can readily conduct. In bulk crystals, is H doping really the cause? Answering this question represents a major challenge because the donor concentration is in the 1017-1018 cm-3 range. Determining the donor identity in this concentration range is a major experimental hurdle. How does dsurf depend on crystallographic orientation? How does the phenomenon depend on the extent of band bending? Does persistent photoconductivity come into play? Can the effect be modified by band bending modification via surface photovoltage effects? All of the above questions pertain to epitaxial films as well, but other questions also arise. How do the film thickness and strain state affect dsurf? Can the surface conduction effect be enhanced by judicious design and growth of quantum well structures made from ZnO, MgxZn1-xO, and/or CdxZn1-xO? Answering these and other questions that arise will expand our understanding of this fascinating and potentially important material, as well as pave the way for device applications.
Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power Free Electron Lasers (FEL). Photocathode quantum efficiency (QE) degradation is due to residual gasses in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes, which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include Helium Ion Microscopy (HIM), Rutherford Backscattering Spectrometry (RBS), Atomic Force Microscopy (AFM) and Secondary Ion Mass Spectrometry (SIMS). In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the Continuous Electron Beam Accelerator Facility (CEBAF) photoinjector and one unused, were also analyzed using Transmission Electron Microscopy (TEM) and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but shows evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.
A statistical analysis was made on ground soils to define the general relationship and ranges of values of the field moisture relative to both the variance and coefficient of variation for a given test site and depth increment. The results of the variability study show that: (1) moisture variations within any given large field area are inherent and can either be controlled nor reduced; (2) neither a single value of the standard deviation nor coefficient of variation uniquely define the variability over the complete range of mean field moisture contents examined; and (3) using an upper bound standard deviation parameter clearly defines the maximum range of anticipated moisture variability. 87 percent of all large field moisture content standard deviations were less than 3 percent while about 96 percent of all the computed values had an upper bound of sigma=4 percent for these intensively sampled fields. The limit of accuracy curves of mean soil moisture measurements for large field sites relative to the required number of samples were determined.
This international standard specifies the minimum amount of information required for describing the methods of charge control in measurements of Auger electron transitions from insulating specimens by electron-stimulated Auger electron spectroscopy to be reported with the analytical results. Information is provided in an Annex on methods that have been found useful for charge control prior to or during AES analysis. The Annex also includes a summary table of methods or approaches, ordered by simplicity of approach. A similar international standard has been published for x-ray photoelectron spectroscopy (ISO 19318: 2003(E), Surface chemical analysis - X-ray photoelectron spectroscopy - Reporting of methods used for charge control and charge correction).
Flutter analysis for thin lifting surfaces by application of supersonic kernel function procedure
Galileo in-situ dust measurements have shown that the Galilean moons are surrounded by tenuous dust clouds formed by collisional ejecta from their icy surfaces, kicked up by impacts of interplanetary micrometeoroids. The majority of the ejecta dust particles have been sensed at altitudes below five between 0.5 and 1 micron, just above the detector threshold, indicating a size distribution decreasing towards bigger particles. their parent bodies. They carry information about the properties of the surface from which they have been kicked up. In particular, these grains may carry organic compounds and other chemicals of biological relevance if they exist on the icy Galilean moons. In-situ analysis of the grain composition with a sophisticated dust analyzer instrument flying on a Jupiter Icy Moons Orbiter can provide important information about geochemical and geophysical processes during the evolutionary histories of these moons which are not accessible with other techniques from an orbiter spacecraft. Thus, spacecraft-based in-situ dust measurements can be used as a diagnostic tool for the analysis of the surface composition of the moons. This way, the in-situ measurements turn into a remote sensing technique by using the dust instrument like a telescope for surface investigation. An instrument capable of very high resolution composition analysis of dust particles is the Cometary Secondary Ion Mass Analyzer (COSIMA). The instrument was originally developed for the Comet Rendezvous and Asteroid Flyby (CRAF) mission and has now been built for ESA'S comet orbiter Rosetta. Dust particles are collected on a target and are later located by an optical microscope camera. A pulsed primary indium ion gun partially ionizes the dust grains. The generated secondary ions are accelerated in an electric field and travel through a reflectron-type time-of-flight ion mass spectrometer.
RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ) ready Advion TriVersa NanoMate system. RESULTS: Under optimized conditions about 10% of laser ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 m x 160 m) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA (ca. 1 mm diameter liquid extraction spot). The set-up was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent resistant materials.
Patterns of roughness evolution have been studied analysis of high magnification video observations of accreting ice surfaces provided by the NASA Lewis Research Center. Three distinct patterns of surface roughness generation have been identified within the parametric regions studied. They include: Rime, Multi-Zone Glaze, and Uniform Glaze. Under most icing conditions, a brief period of transient rime ice growth was observed caused by heat conduction into the body. The resulting thin rime layer explains previously observed insensitivity of some ice accretions to substrate insensitivity of some ice accretions to substrate surface chemistry and may provide justification for simplifying assumptions in ice accretion sailing and modeling effects.
To meet the ever-increasing need for high-throughput screening in metabolic engineering, information-rich, fast screening methods are needed. Mass spectrometry (MS) provides an efficient and general approach for metabolite screening and offers the capability of characterizing a broad range of analytes in a label-free manner, but often requires a range of sample clean-up and extraction steps. Liquid extraction surface analysis (LESA) coupled MS is an image-guided MS surface analysis approach that directly samples and introduces metabolites from a surface to MS. Here, we combined the advantages of LESA–MS and an acoustic liquid handler with stable isotope-labeled internal standards. This approach provides absolute quantitation of target chemicals from liquid culture-dried droplets and enables high-throughput quantitative screening for microbial metabolites. In this paper, LESA–MS was successfully applied to quantify several different metabolites (itaconic acid, triacetic acid lactone, and palmitic acid) from different yeast strains in different mediums, demonstrating its versatility, accuracy, and efficiency across a range of microbial engineering applications.
Surface wave study techniques, discussing digital moving window analysis of group and phase velocity and use of time variable filters
We present an algorithm to calculate the normal albedo of Mars at the MOLA wavelength using the MGS Thermal Emission Spectrometer (TES) 9 um opacity measurement [6].
In late 2011, an A(H3N8) influenza virus infection resulted in the deaths of 162 New England harbor seals. Virus sequence analysis and virus receptor binding studies highlighted potential markers responsible for mammalian adaptation and a mixed receptor binding preference. Here, we present a detailed structural and biochemical analysis of the surface antigens of the virus. Results obtained with recombinant proteins for both the hemagglutinin and neuraminidase indicate a true avian receptor binding preference. Although the detection of this virus in new species highlights an increased potential for cross-species transmission, our results indicate that the A(H3N8) virus currently poses a low risk to humans. Cross-species transmission of zoonotic influenza viruses increases public health concerns. Here, we report a molecular and structural study of the major surface proteins from an A(H3N8) influenza virus isolated from New England harbor seals. Furthermore, the results improve our understanding of these viruses as they evolve and provide important information to aid ongoing risk assessment analyses as these zoonotic influenza viruses continue to circulate and adapt to new hosts.
The report presents analyzed surface areas on particular experiment trays from the Long Duration Exposure Facility (LDEF) for silicone-based molecular contamination. The trays for examination were part of the Ultra-Heavy Cosmic Ray Experiment (UHCRE). These particular trays were chosen because each tray was identical to the others in construction, and the materials on each tray were well known, documented, and characterized. In particular, a known specific source of silicone contamination was present on each tray. Only the exposure conditions varied from tray to tray. The results of post-flight analyses of surfaces of three trays were compared with the predictions of the three different spacecraft molecular contamination models. Phase one tasks included: 1) documenting the detailed geometry of the hardware; 2) determining essential properties of the anodized aluminum, Velcro(Tm), silverized Teflon(Tm), silicone gaskets, and DC6-1104(Tm) silicone adhesive materials used to make the trays, tray covers, and thermal control blankets; 3) selecting and removing areas from each tray; and 4) beginning surface analysis of the selected tray walls. Phase two tasks included: 1) completion of surface analysis measurements of the selected tray surface, 2) obtaining auger depth profiles at selected locations, and 3) running versions of the ISEM, MOFLUX, and PLIMP (Plume Impingement) contamination prediction models and making comparisons with experimental results.