Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Generating Emissions Inventory for Carbon Capture and Storage Analysis for Carbon-Intensive Industrial Sectors

Decarbonizing the industrial sector is critical to achieve carbon dioxide (CO2) emissions reductions goals of the Biden Administration. Currently available decarbonization options include electrification, fuel switching to zero carbon fuels like green hydrogen (H2) and carbon capture and storage (CCS). Application of post-combustion carbon capture (PCCC) technology in the power sector, as well as research at the U.S. Department of Energy's Fossil Energy and Carbon Management (FECM) Office has shown that its application in the industrial sector could have co-benefits in the form of emissions reductions of non-CO2 regulated pollutants. For example, solvent based PCCC systems require pre-conditioning of flue gas to remove sulfur and particulate matter (PM) upstream of the CO2 absorber. However, there is a lack of understanding about the type of non-CO2 pollutants which can be captured and the amount of reduction possible. PCCC application differs across industrial sectors as it depends on the availability of decarbonization options, characteristics of industrial processes and the amount and composition of pollutant flows. Certain facilities can also have multiple effluent flows with or without a CO2 stream. As such, understanding industrial processes and their effluent flows in detail is required to quantify the co-benefits opportunities presented by PCCC. Considering this requirement, the goal of this analysis is to develop a high-resolution inventory of effluent flows from facilities of 8 industrial sectors in the U.S. These industrial sectors - ethanol, ammonia, cement, steel, natural gas processing, hydrogen, petroleum refining and wood and pulp products - have carbon-intensive effluent flows, and thus are prime candidates for PCCC applications. In this study, we map the composition of pollutant flow from flue stacks across the identified facilities. Using data available in three Environmental Protection Agency (EPA) databases - the Green House Gas Reporting Program (GHGRP), the National Emissions Inventory (NEI) and the Toxic Release Inventory (TRI), we create a combined inventory which lists the type, amount, and concentration of pollutant flows. Using total weight of the pollutant flow back calculated from observed data for CO2 concentrations in flue gas for individual sectors, we calculate the concentration of each pollutant in the flue gas stream. Thus, the resultant emissions inventory includes the following details for each facility in the sector: facility-level and if possible, process-level pollutant flows, concentrations of pollutants in the flue gas, and geographical coordinates of the facilities. A detailed statistical analysis and summary allows us to search for erroneous data and remove them from the final inventory. The generation of the inventory is achieved using a python-based framework which can recreate this inventory for other industrial sectors as well as using newer releases of emission inventories from EPA. The statistical analysis performed on the inventory is also calibrated and automated to identify outliers efficiently.

air pollutants↗

Using AIRS and IASI Data to Evaluate Absolute Radiometric Accuracy and Stability for Climate Applications

The creation of multi-decadal data sets for climate research requires better than 100 mK absolute calibration accuracy for the full range of spectral temperatures encountered under global conditions. Validation that this accuracy is achieved by the operational hyperspectral sounders from polar orbit is facilitated by comparing data from two instruments. Extreme radiometric calibration stability is critical to allow a long time series of noisy, but presumably long-term accurate truth measurements to be used for the validation of absolute accuracy at the 100 mK level. We use the RTGSST in the tropical oceans as ground truth. The difference between the AIRS derived sst2616 and the RTGSST based on six years of data shows a systematic cold bias of about 250 mK, but better than 4 mK/year stability. The double difference between AIRS and the RTGSST and IASI and the RTGSST with less than one year of data already allows statements at the 100 mK absolute level. It shows a 60 mK difference between the AIRS and the IASI calibration at 2616 cm-(sup 1) and 300 K, with a statistically insignificant 20 mK shift in six months.

EOS Aqua↗

Comparison of Iterative and Non-Iterative Strain-Gage Balance Load Calculation Methods

The accuracy of iterative and non-iterative strain-gage balance load calculation methods was compared using data from the calibration of a force balance. Two iterative and one non-iterative method were investigated. In addition, transformations were applied to balance loads in order to process the calibration data in both direct read and force balance format. NASA's regression model optimization tool BALFIT was used to generate optimized regression models of the calibration data for each of the three load calculation methods. This approach made sure that the selected regression models met strict statistical quality requirements. The comparison of the standard deviation of the load residuals showed that the first iterative method may be applied to data in both the direct read and force balance format. The second iterative method, on the other hand, implicitly assumes that the primary gage sensitivities of all balance gages exist. Therefore, the second iterative method only works if the given balance data is processed in force balance format. The calibration data set was also processed using the non-iterative method. Standard deviations of the load residuals for the three load calculation methods were compared. Overall, the standard deviations show very good agreement. The load prediction accuracies of the three methods appear to be compatible as long as regression models used to analyze the calibration data meet strict statistical quality requirements. Recent improvements of the regression model optimization tool BALFIT are also discussed in the paper.

Ulbrich, N.↗

Langley Wind Tunnel Data Quality Assurance-Check Standard Results

A framework for statistical evaluation, control and improvement of wind funnel measurement processes is presented The methodology is adapted from elements of the Measurement Assurance Plans developed by the National Bureau of Standards (now the National Institute of Standards and Technology) for standards and calibration laboratories. The present methodology is based on the notions of statistical quality control (SQC) together with check standard testing and a small number of customer repeat-run sets. The results of check standard and customer repeat-run -sets are analyzed using the statistical control chart-methods of Walter A. Shewhart long familiar to the SQC community. Control chart results are presented for. various measurement processes in five facilities at Langley Research Center. The processes include test section calibration, force and moment measurements with a balance, and instrument calibration.

Hemsch, Michael J.↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

ROSE: A reduced-order scattering emulator for optical models

A new generation of phenomenological optical potentials requires robust calibration and uncertainty quantification, motivating the use of Bayesian statistical methods. These Bayesian methods usually require calculating observables for thousands or even millions of parameter sets, making fast and accurate emulators highly desirable or even essential. Emulating scattering across different energies or with interactions such as optical potentials is challenging because of the nonaffine parameter dependence, meaning the parameters do not all factorize from individual operators. Here we introduce and demonstrate the reduced-order scattering emulator ( ROSE ) framework, a reduced basis emulator that can handle nonaffine problems. ROSE is fully extensible and works within the publicly available band framework software suite for calibration, model mixing, and experimental design. As a demonstration problem, we use ROSE to calibrate a realistic nucleon-target scattering model through the calculation of elastic cross sections. This problem shows the practical value of the ROSE framework for Bayesian uncertainty quantification with controlled trade-offs between emulator speed and accuracy as compared to high-fidelity solvers. Finally, planned extensions of ROSE are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prime VI

SAND2025-03757O Prime VI is a distribution-of-disease outbreak model calibration code based on variational inference. It accompanies a publication for submission to Statistics in Medicine journal, and the code will be maintained for open-source use on Sandia's GitLab. The software provides methods for calibrating an epidemiological model to measured case-count data for a multitude of correlated spatial regions. The code solves a Bayesian inverse problem for model calibration where the posterior over-model parameters are approximated through a custom implementation of variational inference. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Landsat-8 Thermal Infrared Sensor (TIRS) Vicarious Radiometric Calibration

Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 micrometers (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board Landsat-8. The TIRS instrument has an internal calibration system consisting of a variable temperature blackbody and a special viewport with which it can see deep space; a two point calibration can be performed twice an orbit. Immediately after launch, a rigorous vicarious calibration program was started to validate the absolute calibration of the system. The two vicarious calibration teams, NASA/Jet Propulsion Laboratory (JPL) and the Rochester Institute of Technology (RIT), both make use of buoys deployed on large water bodies as the primary monitoring technique. RIT took advantage of cross-calibration opportunity soon after launch when Landsat-8 and Landsat-7 were imaging the same targets within a few minutes of each other to perform a validation of the absolute calibration. Terra MODIS is also being used for regular monitoring of the TIRS absolute calibration. The buoy initial results showed a large error in both bands, 0.29 and 0.51 W/sq m·sr·micrometers or -2.1 K and -4.4 K at 300 K in Band 10 and 11 respectively, where TIRS data was too hot. A calibration update was recommended for both bands to correct for a bias error and was implemented on 3 February 2014 in the USGS/EROS processing system, but the residual variability is still larger than desired for both bands (0.12 and 0.2 W/sq m·sr·micrometers or 0.87 and 1.67 K at 300 K). Additional work has uncovered the source of the calibration error: out-of-field stray light. While analysis continues to characterize the stray light contribution, the vicarious calibration work proceeds. The additional data have not changed the statistical assessment but indicate that the correction (particularly in band 11) is probably only valid for a subset of data. While the stray light effect is small enough in Band 10 to make the data useful across a wide array of applications, the effect in Band 11 is larger and the vicarious results suggest that Band 11 data should not be used where absolute calibration is required.

TIIRS↗

(abstract) Deep Space Network Radiometric Remote Sensing Program

Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid,and precipitation , emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band becausecommunication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of watervapor-induced prop agation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity waveexperiments, and r adio science missions. During 1993, WVRs provided data for propagation mode development, supp orted planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily, monthly, and seasonal variations. Only long-term monitoring will prevent biases from being introduced by an exceptionally wet or dry year. Support for planetary missions included tropospheric calibration for the recent Mars Observer gravity wave experiments and Ka-band link experiment (KaBLE). Additionally, several proposed radio science experiments such as profiling planetary atmospheres using satellite occultations and Ka-band gravitational wave searches require advanced radiometer technology development. Finally, there has been a consistent advanced technology program to advance satellite navigational and tracking capabilities. This year that included an experiment with radiometer based tropospheric calibration for a series of VLBI catalog measurements.

microwave propagation Ka-band weather variations r↗

Deep Space Network Radiometric Remote Sensing Program

Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily, monthly, and seasonal variations. Only long-term monitoring will prevent biases from being introduced by an exceptionally wet or dry year. Support for planetary missions included tropospheric calibration for the recent Mars Observer gravity wave experiments and Ka-band link experiment (KaBLE). Additionally, several proposed radio science experiments such as profiling planetary atmospheres using satellite occultations and Ka-band gravitational wave searches require advanced radiometer technology development. Finally, there has been a consistent advanced technology program to advance satellite navigational and tracking capabilities. This year that included an experiment with radiometer based tropospheric calibration for a series of VLBI catalog measurements.

tropospheric calibration atmospheric water radio s↗

Full Aerothermal Characterization of the 6- by 9-Foot Icing Research Tunnel (2019 Test)

A full aerothermal characterization of the NASA Glenn Icing Research Tunnel (IRT) was completed in August 2019. A mandatory maintenance period required the test entry to be separated into two phases: the first occurring in April 2019 and the second in August 2019. The hardware used during this test entry consisted of the 6-foot quick-check rake, 6-foot traversing rake, RTD array, and hot-wire rake. The 6-foot quick check rake collects static pressure, total pressure, total temperature, and flow angularity data along the centerline of the test section. The data from the 6-foot quick-check rake were used to generate test section calibration relationships for total and static pressure as well as implement statistical process control. The 6-foot traversing rake collects flow uniformity data across the test section for various flow parameters, such as static pressure, total pressure, and flow angularity. Total temperature flow uniformity data is mapped by the RTD array and is used to generate the test section calibration relationship for total temperature. The hot-wire rake measures turbulence intensity at three lateral locations and characterizes airspeed unsteadiness in the test section. The test entry resulted in updated calibration relationships and a full characterization of test section flow quality and flow uniformity in the IRT.

Wind↗

Search for a heavy neutral lepton with the MAGNETO-𝜈 experiment using 241 Pu 𝛽 − decays

The MAGNETO-𝜈 experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the 𝛽 − -decay spectrum of 241 Pu. We present spectra comprising a total of 194 million 𝛽 − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of 241 Pu 𝛽 − decay to date. The 𝛽-endpoint energy was determined using 𝛾 rays and x-rays from an external 133 Ba calibration source, yielding 𝑄 𝛽 = 22.273⁢ (33) ⁢keV. The measured spectrum shows no statistically significant deviation from the allowed 𝛽-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, |𝑈 𝑒⁢4 | 2 < 1.31 × 10 −3 at the 95% confidence level.

A ≥ 220↗

Hydrologic applicability of satellite-based precipitation estimates for irrigation water management in the data-scarce region

Reliable precipitation estimates are crucial for planning and managing water resources, monitoring hydrologic extremes, and fulfilling irrigation water requirements. Accurate precipitation estimates are particularly challenging in complex mountain terrains, where monitoring gauges are often sparsely distributed due to their remote locations, and high installation and long-term operation costs. Recent advances in satellite-based precipitation estimates offer promising opportunities to improve our understanding of hydrologic processes and their applications for irrigation water management. Several datasets are available varying considerably in terms of their data sources, quality control methods, estimation procedure, and spatiotemporal resolutions. Choosing the most suitable dataset for a particular application is a complex task. In this study, we (1) evaluate the performance of six satellite-based precipitation estimates (SPEs): i) CHIRPS v2.0, ii) CMORPH v1.0, iii) ERA5, iv) IMERG v6, v) MSWEP v2.8, and vi) PERSIANN-CDR against the gauge precipitation using continuous statistical and categorical indices, (2) integrate SPEs with a calibrated semi-distributed hydrologic model to predict streamflow, and (3) demonstrate practical implications of improved streamflow prediction for irrigation water management in the central Himalayan region, Nepal. Our results illustrate that satellite-based precipitation estimates have competitive performance in capturing a wide range of rainfall characteristics, with demonstrated variability across river basins and time scales. Further, there are no significant discrepancies observed in satellite-based precipitation estimates for estimating irrigation water requirements for the three major crops (maize, wheat, and paddy) during the cropping period across the selected river basins, showing a greater promise for irrigation water management planning and decision making.

54 ENVIRONMENTAL SCIENCES↗

Functional protein mining with conformal guarantees

Molecular structure prediction and homology detection offer promising paths to discovering protein function and evolutionary relationships. However, current approaches lack statistical reliability assurances, limiting their practical utility for selecting proteins for further experimental and in-silico characterization. To address this challenge, we introduce a statistically principled approach to protein search leveraging principles from conformal prediction, offering a framework that ensures statistical guarantees with user-specified risk and provides calibrated probabilities (rather than raw ML scores) for any protein search model. Our method (1) lets users select many biologically-relevant loss metrics (i.e. false discovery rate) and assigns reliable functional probabilities for annotating genes of unknown function; (2) achieves state-of-the-art performance in enzyme classification without training new models; and (3) robustly and rapidly pre-filters proteins for computationally intensive structural alignment algorithms. Our framework enhances the reliability of protein homology detection and enables the discovery of uncharacterized proteins with likely desirable functional properties.

59 BASIC BIOLOGICAL SCIENCES↗

Model-based quantification of margins and uncertainties in metal additive manufacturing for process design and qualification

Laser powder bed fusion (LPBF) Additive Manufacturing (AM) has the potential to enable the production of components with novel designs and material properties unachievable otherwise. However, process repeatability is a challenge, making qualification ill-defined and greatly reducing the utility of what could be an important manufacturing technology. In this work, a combination of modeling, uncertainty quantification (UQ), and experimentation are used in an effort to predict and bound the range of possible outcomes of the LPBF process. Quantities of interest predicted are melt pool dimensions, microstructure features, and mechanical distortions. A combination of high fidelity thermal-fluid models, microstructure growth models, and reduced fidelity, rapid thermal and mechanical models are used. Uncertainty propagation techniques are used to predict probability distributions of quantities of interest from estimates of process uncertainties. Repeated experiments are done to quantify observed probability distributions and compared to predicted distributions to determine if predictions are precise and accurate. Novel modeling methods are microstrucutre characterization techniques are also discussed. It is found that high fidelity models do a generally good job bounding experimentally observed melt pool morphologies for both bead-on-plate and powder bed cases. Microstructure models are able to bound a number of experimentally observed microstructure statistics, but with low precision due to challenges with calibrating the microstructure growth model parameters. A developed modified inherent strain distortion model does not accurately predict observed distortions. A lumped laser distortion model shows promise in being both accurately and precisely bounding observed outcomes from the deflection comb build, but requires further evaluation on more builds and geometries.

36 MATERIALS SCIENCE↗

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.↗

Determination of jet calibration and energy resolution in proton–proton collisions at $\sqrt{s} = 8~\hbox {TeV}$ using the ATLAS detector

The jet energy scale, jet energy resolution, and their systematic uncertainties are measured for jets reconstructed with the ATLAS detector in 2012 using proton–proton data produced at a centre-of-mass energy of 8 TeV with an integrated luminosity of 20fb -1 . Jets are reconstructed from clusters of energy depositions in the ATLAS calorimeters using the anti-k t algorithm. A jet calibration scheme is applied in multiple steps, each addressing specific effects including mitigation of contributions from additional proton–proton collisions, loss of energy in dead material, calorimeter non-compensation, angular biases and other global jet effects. The final calibration step uses several in situ techniques and corrects for residual effects not captured by the initial calibration. Furthermore, these analyses measure both the jet energy scale and resolution by exploiting the transverse momentum balance in γ + jet, Z + jet, dijet, and multijet events. A statistical combination of these measurements is performed. In the central detector region, the derived calibration has a precision better than 1% for jets with transverse momentum 150 GeV < p T < 1500 GeV, and the relative energy resolution is (8.4 ± 0.6)% for p T =100 GeV and (23 ± 2)% for p T =20 GeV. The calibration scheme for jets with radius parameter R = 1.0, for which jets receive a dedicated calibration of the jet mass, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An IEEE 1451.1 Architecture for ISHM Applications

The IEEE 1451.1 Standard for a Smart Transducer Interface defines a common network information model for connecting and managing smart elements in control and data acquisition networks using network-capable application processors (NCAPs). The Standard is a network-neutral design model that is easily ported across operating systems and physical networks for implementing complex acquisition and control applications by simply plugging in the appropriate network level drivers. To simplify configuration and tracking of transducer and actuator details, the family of 1451 standards defines a Transducer Electronic Data Sheet (TEDS) that is associated with each physical element. The TEDS contains all of the pertinent information about the physical operations of a transducer (such as operating regions, calibration tables, and manufacturer information), which the NCAP uses to configure the system to support a specific transducer. The Integrated Systems Health Management (ISHM) group at NASA's John C. Stennis Space Center (SSC) has been developing an ISHM architecture that utilizes IEEE 1451.1 as the primary configuration and data acquisition mechanism for managing and collecting information from a network of distributed intelligent sensing elements. This work has involved collaboration with other NASA centers, universities and aerospace industries to develop IEEE 1451.1 compliant sensors and interfaces tailored to support health assessment of complex systems. This paper and presentation describe the development and implementation of an interface for the configuration, management and communication of data, information and knowledge generated by a distributed system of IEEE 1451.1 intelligent elements monitoring a rocket engine test system. In this context, an intelligent element is defined as one incorporating support for the IEEE 1451.x standards and additional ISHM functions. Our implementation supports real-time collection of both measurement data (raw ADC counts and converted engineering units) and health statistics produced by each intelligent element. The handling of configuration, calibration and health information is automated by using the TEDS in combination with other electronic data sheets extensions to convey health parameters. By integrating the IEEE 1451.1 Standard for a Smart Transducer Interface with ISHM technologies, each element within a complex system becomes a highly flexible computation engine capable of self-validation and performing other measures of the quality of information it is producing.

Morris, Jon A.↗