Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Detecting thermal crack growth on a large additive manufactured structure using acoustic emission

Large format additive manufacturing (LFAM) proved to have a great potential to become an adjacent technology to traditional manufacturing methods. One of the sectors LFAM is targeting is rapid tool/mold development for composites. This includes large mold structures used for high-temperature molding techniques (in-oven or autoclave). Although, these large printed structures (reaching hundreds of pounds) develop thermal-residual stress during cool-down and can eventually crack, turning the structure into waste. Acoustic emission (AE), a passive non-intrusive global nondestructive evaluation (NDE) technique, was used to monitor crack growth and can provide the right tools that can be used for feedback loop for corrective action. This research performs thermal testing on a large AM mold with preexisting cracks, in an attempt to monitor crack growth using AE. AE was able to detect, identify and locate the crack source by means of acoustic features, waveform characteristics, spectrum analysis, and difference in arrival times.

Spencer, Ryan↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

High-resolution Gamma Spectroscopy Measurements of Pressurized Water Reactor Spent Nuclear Fuel Rods

International nuclear safeguards use nondestructive assay techniques to verify declared characteristics of spent nuclear fuel (SNF) assemblies. The declared characteristics usually include the initial enrichment, assembly average burnup, and irradiation history. The primary nondestructive assay tool used by the International Atomic Energy Agency has been the fork detector irradiated fuel measurement system, which uses gross gamma and neutron correlations; however, there have been several research publications within the last decade on the use of high-resolution gamma spectroscopy for the determination of SNF characteristics. References [1]–[6] are published journal articles on this subject from 2006–2016. This report describes measurements of 25 individual SNF rods using high-resolution gamma spectroscopy. Details of the measurement geometry, measurement settings, and rod characteristics are documented. These spectra are intended for the validation of simulation codes that calculate SNF inventory and source term characteristics. The spectrum archive is available to evaluate future spectrum analysis methods. The archive contains full axial scan spectra of each SNF rod. This allows more detailed comparison between simulation and nondestructive analysis than is possible on assemblies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Radiation Emissions Due To Volcano Particulates During Kilauea Eruption

I traveled to the island of Hawaii on May 19th, 2018 to measure gamma emissions from rainfall in the area impacted by recent volcanic eruptions. Kilauea Volcano, which has erupted nearly continuously from the area of Puu Oo Crater since 1983, entered a new eruptive phase on April 30, 2018 with the collapse of the Puu Oo Lava Lake and movement of magma to the east along the east rift zone. Beginning May 3, intrusion of this magma in the lower east rift zone led to eruptions from newly formed fissures that continue today. The eruption has provided geologists an opportunity to examine and document processes that were inaccessible previously on the Hawaiian island. The eruption also provided me an opportunity to gather gamma emissions spectrum from the newly erupted lava and the rainfall that may have incorporated gases and particulate from the erupting fissures. I brought a Light House Detector (LHD) that would be used to measure the gamma emissions, and intended to purchase any additional supplies necessary to complete my surveys. The goal of the trip was to determine if gamma spectrum analysis of rainfall on the leeward side of the erupting fissures could be differentiated from rainfall on the windward side of the fissures, and if the leeward rainfall had any impact on the background radiation for a given sample area.

58 GEOSCIENCES↗

BNL Irradiation Damage Studies of the Metal Matrix Composite Mo-GR Considered for High Luminosity LHC Collimator Upgrade

A comprehensive experimental/analytical effort on the resilience of Mo-GR metal matrix composite to high energy proton beam irradiation combined with elevated temperatures has been undertaken at BNL on behalf of the CERN LHC Collimation effort as part of an effort to identify novel materials that will exhibit optimal performance in the high luminosity LHC upgrade. While the Mo-Gr composite was one of the four (4) different materials or composites (Mo, Glidcop, Cu-CD and Mo-Gr) that constituted the High Luminosity LHC collimation material campaign, this report focuses solely on Mo-GR with some reference to its constituents Mo and graphite (graphite studied in previous research or irradiation campaigns along with the carbonfiber composites). The multi-faceted study on Mo-GR (one of several different alloys and matrices) performed at BNL included the following stages: Irradiation damage phase using the 200 MeV proton beams of the BNL Linac and the BLIP target beamline. Specifically, Mo-GR samples encapsulated under vacuum in special capsules were exposed to direct protons as part of a multi-capsule, multi-material irradiation array. The long-term irradiation of ~8 weeks resulted in an accumulated fluence at the Mo-GR of ~10 21 p/cm 2 . The irradiation was conducted in two sessions (RUN 2013 and RUN 2014 of the BLIP operations in tandem with isotope production). Irradiation damage experiments using spallation neutrons at the BLIP beamline generated by 118 MeV protons that interact with and are stopped by an array of isotope producing targets. The Mo-GR capsule combined the effects of short-term proton irradiation and the effects of the mixed irradiating spectrum. Spallation-induced irradiation of Mo-GR at sub-zero temperatures utilizing the mixed field generated by spallation of 28 MeV protons of the BN Tandem on Mo targets Gamma spectrum analysis of the heavily irradiated Mo-Gr to enable the correlation of predicted isotope profile from Mo-Gr by transport codes and therefore the utilization of the validated transport code in other aspects of the damage induced on Mo-Gr by irradiation.

43 PARTICLE ACCELERATORS↗

Radioisotope Identification with List-Mode Gamma Ray Data: A rigorous assessment on the value of temporal information applied to radioisotope identification.

This work explores the potential of utilizing temporal data from gamma-ray detectors, known as list-mode data, to enhance radioisotope identification. Traditional identification methods, which rely on full gamma-ray spectrum analysis, often require long dwell times and struggle with “confuser” sources, or spectra with similarly spaced spectral peaks. We hypothesize that by leveraging the probabilistic nature of nuclear decay and the time-encoded information from decay sequences and interactions with surrounding materials, we can improve classification accuracy over static spectral analysis. This research rigorously examines the temporal content of list-mode data through exploratory data analysis via correlation discovery and information theory. We further propose a basic classification model that can utilize spectral or temporal data (or both) to determine if the incorporation of temporal information can improve radioisotope identification. The findings suggest that the temporal information present in list-mode gamma-ray data has merit and should be further investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved battery parameter estimation method considering operating scenarios for HEV/EV applications

This study presents an improved battery parameter estimation method based on typical operating scenarios in hybrid electric vehicles and pure electric vehicles. Compared with the conventional estimation methods, the proposed method takes both the constant-current charging and the dynamic driving scenarios into account, and two separate sets of model parameters are estimated through different parts of the pulse-rest test. The model parameters for the constant-charging scenario are estimated from the data in the pulse-charging periods, while the model parameters for the dynamic driving scenario are estimated from the data in the rest periods, and the length of the fitted dataset is determined by the spectrum analysis of the load current. In addition, the unsaturated phenomenon caused by the long-term resistor-capacitor (RC) network is analyzed, and the initial voltage expressions of the RC networks in the fitting functions are improved to ensure a higher model fidelity. Simulation and experiment results validated the feasibility of the developed estimation method.

25 ENERGY STORAGE↗

Long-term changes in the seasonality of Baltic sea level

The seasonal cycle accounts for about 40% of the total sea level variability in the Baltic Sea. In a climate change context, changes are expected to occur, not only in mean levels but also in the seasonal characteristics of sea level. The present study addresses the quantification of changes in the seasonal cycle of sea level from a set of century-long tide gauge records in the Baltic Sea. In order to obtain robust estimates of the changes in amplitude and phase of the seasonal cycle, we apply different methods, including continuous wavelet filtering, multi-resolution decomposition based on the maximal overlap discrete wavelet transform, auto-regressive-based decomposition, singular spectrum analysis and empirical mode decomposition. The results show that all methods generally trace a similar long-term variability of the annual cycle amplitudes, and we focus on discrete wavelet analysis as the natural counterpart of classical moving Fourier analysis. In contrast to previous studies suggesting the existence of long-term changes in the seasonal cycle, in particular an increase of the annual amplitude, we find alternating periods of high and low amplitudes without any clear indication of systematic long-term trends. The derived seasonal patterns are spatially coherent, discriminating the stations in the Baltic entrance from the remaining stations in the Baltic basin, for which zonal wind accounts for typically more than 40% of the variations in amplitude.

54 ENVIRONMENTAL SCIENCES↗

WIYN Open Cluster Study LXXIX. M48 (NGC 2548) I. Radial Velocities, Rotational Velocities, and Metallicities of Stars in the Open Cluster M48 (NGC 2548)

WIYN/Hydra spectra (R ∼ 13,500, signal-to-noise pixel{sup −1} = 50–1000) of a 400 Å region around Li 6708 Å are used to determine radial and rotational velocities for 287 photometrically selected candidate members of the open cluster M48. The sample ranges from turnoff A stars to late-K dwarfs and eight giants. We combine our V {sub RAD} measurements and power spectrum analysis with parallax and proper motion data from Gaia DR2 to evaluate membership and multiplicity. We classify 152 stars as single cluster members, 11 as binary members, 16 as members of uncertain multiplicity, 56 as single nonmembers, 28 as single “likely” nonmembers, two as single “likely” members, one as a binary “likely” member, five as binary nonmembers, 10 as “likely” members of uncertain multiplicity, three as nonmembers of uncertain multiplicity, and three as “likely” nonmembers of uncertain multiplicity. From a subsample of 95 single members, we derive V {sub RAD} = 8.512 ± 0.087 km s{sup −1} (σ {sub μ}, and σ = 0.848 km s{sup −1}). Using 16 isolated Fe I lines for a subsample of 99 single members (that have σ{sub T{sub e{sub f{sub f}}}}<75 K (from 10 colors from UBVRI), v sin i < 25 km s{sup −1}, and well-behaved Fe I lines), [Fe/H]{sub M48} = −0.063 ± 0.007 dex (σ {sub μ}). [Fe/H] is independent of T {sub eff} over an unprecedentedly large range of 2500 K. The minimum cluster binary fraction is 11%–21%. M48 exhibits a clear but modest broadening of the main-sequence turnoff, and there is no correlation between color and v sin i.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification and assignment of rotational spectra using artificial neural networks

A method of identifying molecular parameters may include receiving observed transition frequencies, generating transition frequency sets and a spectral parameter sets, training one or more artificial neural networks by analyzing the transition frequency sets and the spectral parameter sets, analyzing the observed transition frequencies using the one or more trained artificial neural networks to predict estimated spectral parameters, and identifying molecular parameters by analyzing the estimated spectral parameters. A molecular parameter identification system may include a rotational spectrometer, a user interface, and a spectrum analysis application that may retrieve observed transition frequencies, identify a Hamiltonian type by a neural network analyzing the observed transition frequencies, select a second trained artificial neural network based on the identified Hamiltonian type, analyze observed transition frequencies using the second artificial neural network to identify estimated spectral parameters, and identify molecular parameters.

Prozuments, Kirills↗

Low-Beta Structure for High Energy Part of Project X

Long 11-cell, {beta} = 0.81 L-band structure is considered as an initial stage of the high-energy part of the Project-X in order to accommodate to a standard Type-4 cryomodule. The cavity shape is optimized for maximal energy gain providing the same time field flatness along the structure not worse than for ILC {beta} = 1 cavity, and the same ratio of surface magnetic field to electric field. The results of spectrum analysis for monopole and dipole HOMs is presented as well.

43 PARTICLE ACCELERATORS↗

THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

IMPLEMENTING THE STANDARD SPECTRUM METHOD FOR ANALYSIS OF β-γ COINCIDENCE SPECTRA

The standard deconvolution analysis tool (SDAT) algorithms were developed and tested at the University of Texas at Austin. These algorithms utilize the standard spectrum technique for spectral analysis of {beta}-{gamma} coincidence spectra for nuclear explosion monitoring. Work has been conducted under this contract to implement these algorithms into a useable scientific software package with a graphical user interface. Improvements include the ability to read in PHD formatted data, gain matching, and data visualization. New auto-calibration algorithms were developed and implemented based on 137Cs spectra for assessment of the energy vs. channel calibrations. Details on the user tool and testing are included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primordial power spectrum: a complete analysis with the WMAP nine-year data

We have improved further the error sensitive Richardson-Lucy deconvolution algorithm making it applicable directly on the un-binned measured angular power spectrum of Cosmic Microwave Background observations to reconstruct the form of the primordial power spectrum. This improvement makes the application of the method significantly more straight forward by removing some intermediate stages of analysis allowing a reconstruction of the primordial spectrum with higher efficiency and precision and with lower computational expenses. Applying the modified algorithm we fit the WMAP 9 year data using the optimized reconstructed form of the primordial spectrum with more than 300 improvement in χ{sup 2}{sub eff} with respect to the best fit power-law. This is clearly beyond the reach of other alternative approaches and reflects the efficiency of the proposed method in the reconstruction process and allow us to look for any possible feature in the primordial spectrum projected in the CMB data. Though the proposed method allow us to look at various possibilities for the form of the primordial spectrum, all having good fit to the data, proper error-analysis is needed to test for consistency of theoretical models since, along with possible physical artefacts, most of the features in the reconstructed spectrum might be arising from fitting noises in the CMB data. Reconstructed error-band for the form of the primordial spectrum using many realizations of the data, all bootstrapped and based on WMAP 9 year data, shows proper consistency of power-law form of the primordial spectrum with the WMAP 9 data at all wave numbers. Including WMAP polarization data in to the analysis have not improved much our results due to its low quality but we expect Planck data will allow us to make a full analysis on CMB observations on both temperature and polarization separately and in combination.

79 ASTRONOMY AND ASTROPHYSICS↗