Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Three phase spectral interferometry for recording high dynamic range optical waveforms with <1 ps resolution over >2 ns records applied to closed-loop pulse shaping

Herein we demonstrate, to our knowledge, a novel spectral interferometry technique that simultaneously captures three spectral interferograms of a signal waveform with a reference pulse. The measured performance is robust to nonidealities and ambient drifts by implementing a precisely calibrated 3 × 3 polarization maintaining (PM) splitter that provides three phase shift differences nominally spaced 120° apart. The system can achieve long record length by implementing three, high resolution, virtually imaged phase array (VIPA) spectrometers. Here, we experimentally implement this technique and demonstrate the measurement of waveforms with >2ns of record while maintaining <1ps resolution.

42 ENGINEERING↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Upper boundaries of active galactic nucleus regions in optical diagnostic diagrams

The distribution of galaxies in optical diagnostic diagrams can provide information about their physical parameters when compared with ionization models under proper assumptions. By using a sample of central emitting regions from the Mapping Nearby Galaxies at Apache Point Observatory survey (MaNGA), we find evidence of the existence of upper boundaries for narrow-line regions (NLRs) of active galactic nuclei (AGNs) in optical Baldwin, Phillips & Terlevich (BPT) diagrams, especially in diagrams involving [Sii]λλ6716, 6731/Hα. Photoionization models can reproduce the boundaries well, as a consequence of the decrease of [Sii]λλ6716, 6731/Hα and [Oiii]λ5007/Hβ ratios at very high metallicity. Whilst the exact location of the upper boundary in the [Sii] BPT diagram depends only weakly on the electron density of the ionized cloud and the secondary nitrogen prescription, its dependence on the shapes of the input spectral energy distributions (SEDs) is much stronger. This allows us to constrain the power-law index of the AGN SED between 1 Ryd and ~100 Ryd to be less than or equal to -1.40 ± 0.05. The coverage of photoionization models in the [Nii] BPT diagram has a stronger dependence on the electron density and the secondary nitrogen prescription. With the density constrained by the [Sii] doublet ratio and the input SED constrained by the [Sii] BPT diagram, we find that the extent of the data in the [Nii] BPT diagram favours those prescriptions with high N/O ratios. Furthermore, although shock-ionized clouds can produce line ratios similar to those from photoionization, the resulting shapes of the upper boundaries, if they exist, would likely be different from those of photoionizing origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Multipole interaction in spectral line broadening by plasmas

A long-standing ambiguity in spectral line broadening theory related to the electric field divergence in the quadrupole term of the screened Coulomb radiator-plasma interaction is examined. This is accomplished with multipole expansions from a Taylor series as well as a partial wave analysis of the screened Coulomb interaction. Here, it is explicitly shown that the two approaches agree up to the octupole term for an effective radiator size small compared to the plasma screening length. Furthermore, the ambigous corrections are confirmed appearing naturally in both methods. For higher multipoles the agreement is demonstrated numerically with a computer program using exact arithmetic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle transport constraints via Bayesian spectral fitting of multiple atomic lines

Optimized operation of fusion devices demands detailed understanding of plasma transport, a problem that must be addressed with advances in both measurement and data analysis techniques. In this work, we adopt Bayesian inference methods to determine experimental particle transport, leveraging opportunities from high-resolution He-like ion spectra in a tokamak plasma. The Bayesian spectral fitting code is used to analyze resonance (w), forbidden (z), intercombination (x, y), and satellite (k, j) lines of He-like Ca following laser blow-off injections on Alcator C-Mod. This offers powerful transport constraints since these lines depend differently on electron temperature and density, but also differ in their relation to Li-like, He-like, and H-like ion densities, often the dominant Ca charge states over most of the C-Mod plasma radius. Using synthetic diagnostics based on the AURORA package, we demonstrate improved effectiveness of impurity transport inferences when spectroscopic data from a progressively larger number of lines are included.

47 OTHER INSTRUMENTATION↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Decoherence dynamics in molecular qubits: Exponential, Gaussian and beyond

In this article, we examine how the structure of system–bath interactions can determine commonly encountered temporal decoherence patterns, such as Gaussian and exponential decay, in molecular and other qubits coupled to a thermal bosonic bath. The analysis, based on a pure dephasing picture that admits analytical treatment, shows that decoherence, in general, is neither purely Gaussian nor exponential but rather the exponential of oscillatory functions, with periods determined by the bath’s frequencies. For initially unentangled qubit-bath states, Gaussian decay is always present at early times. It becomes increasingly dominant with increasing temperature, qubit–bath interaction strength, and bath correlation time. Initial system–bath entanglement that arises due to displacement in the position of the bath states preserves the Gaussian decay. By contrast, strict exponential decay arises only in very specific models that we isolate. However, it becomes dominant for times longer than the bath correlation time or for early times when there is initial entanglement due to momentum displacement of the bath states. For molecular electronic decoherence, the long-time exponential regime plays a limited role as it emerges after most coherence is lost. Thus, the Gaussian decay provides a more suitable (albeit imperfect) model of such decoherence. Furthermore, we discuss the connection between electronic decoherence dynamics and electronic spectroscopic line shape theory, where Gaussian spectral peaks correspond to Gaussian coherence decay and Lorentzian peaks correspond to exponential coherence decay. We find that Gaussian spectral peaks, usually associated with inhomogeneous broadening, can emerge from the entangling unitary system–bath dynamics even when there is no inhomogeneity in the initial conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Frequency domain assurance criterion for defect detection in additively manufactured parts

Additive manufacturing (AM) is a very desirable manufacturing method for industries such as aerospace and automotive due to its ability to create internal features and complex geometries, however, these characteristics also present challenges for nondestructive evaluation (NDE) and defect detection. Dynamic analysis and modal analysis have shown promise for NDE and identifying flaws in AM parts. Frequency Domain Assurance Criterion (FDAC) is a method of dynamic evaluation that represents the degree of correlation between two sets of operational deflection shapes (ODS) at each spectral line. Using colormaps to display the results allows for quick and easy interpretation of parts’ similarities and differences. This method appears to show promise in identifying parts with minor defects and can be used to differentiate nominal and defective parts. This paper explores the use of FDAC on various AM parts with and without intentional defects.

Deonarain, G↗

Spectral Function of the Chiral One-Dimensional Fermi Liquid in the Regime of Strong Interactions

We study momentum-resolved tunneling into a system of spinless chiral one-dimensional fermions, such as electrons at the edge of an integer quantum Hall system. Interactions between particles give rise to broadening of the spectral function of the system. We develop an approach that enables one to obtain the shape of the peak in the spectral function in the regime of strong interaction. We apply our technique to the special cases of short-range and Coulomb interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers↗

Enhancing Graphene Plasmonic Device Performance via its Dielectric Environment

Graphene plasmons provide a compelling avenue toward chip-scale dynamic tuning of infrared light. Dynamic tunability emerges through controlled alterations in the optical properties of the system defining graphene’s plasmonic dispersion. Typically, electrostatic induced alterations of the carrier concentration in graphene working in conjunction with mobility have been considered the primary factors dictating plasmonic tunability. We find here that the surrounding dielectric environment also plays a primary role, dictating not just the energy of the graphene plasmon but so too the magnitude of its tuning and spectral width. To arrive at this conclusion, poles in the imaginary component of the reflection coefficient are used to efficiently survey the effect of the surrounding dielectric on the tuning of the graphene plasmon. By investigating several common polar materials, optical phonons (i.e., the Reststrahlen band) of the dielectric substrate are shown to appreciably affect not only the plasmon’s spectral location but its tunability, and its resonance shape as well. In particular, tunability is maximized when the resonances are spectrally distant from the Reststrahlen band, whereas sharp resonances (i.e., high-Q) are achievable at the band’s edge. Overall, these observations both underscore the necessity of viewing the dielectric environment in aggregate when considering the plasmonic response derived from two-dimensional materials and provide heuristics to design dynamically tunable graphene-based infrared devices.

36 MATERIALS SCIENCE↗

Surface science insight note: A linear algebraic approach to elucidate native films on Fe 3 O 4 surface

Standard materials are often used to obtain spectra that can be compared to those from unknown samples. Spectra measured from these known substances are also used as a means of computing sensitivity factors to allow quantification by X-ray photoelectron spectroscopy (XPS) of less well-defined materials. Spectra from known materials also provide line shapes suitable for inclusion in spectral models which, when fitted to spectra, permit the chemical state for a sample to be assessed. Both types of information depend on isolating photoemission signals from the inelastically scattered signal. In this Insight note, technical issues associated with the use of XPS of as received Fe 3 O 4 powder sample surface are discussed. The Insight note is designed to show how linear algebraic techniques applied to data collected from a sample marketed as pure Fe 3 O 4 powder are used to verify that XPS has been performed on chemistry representative of the sample. The methods described in this Insight note can further be utilized in elucidating complex XPS data obtained from thin films formed or evolved during cyclic/non-steady use of complex (electro)catalyst surfaces, especially in the presence of contaminants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geometric control of hyperbolic exciton-polariton condensate dimers

Coupled many-body quantum systems exhibit rich emergent physics with diverse stationary and dynamical behaviours. By engineering platforms with tunable and distinct coupling mechanisms, new insights emerge into the collective behaviour of coupled many body systems. Particles can be exchanged via evanescent or ballistic coupling: the former, based on proximity, yields large spectral splitting, while the latter requires strict phase-matching, analogous to phase-coupled harmonic oscillators and has a smaller impact on the energy landscape. We demonstrate an all-optically tunable quantum fluid dimer based on exciton-polariton condensates in a photonic crystal waveguide with hyperbolic (saddle-like) dispersion. Varying the dimer’s angle relative to the grating tunes the coupling from evanescent to ballistic. We directly observe spectral features and mass flow shaped by the saddle dispersion. This work highlights photonic crystals as powerful platforms to explore condensed matter phenomena lying at the interface between delay-coupled nonlinear oscillators and tight binding physics.

Georgakilas, Ioannis [IBM Research-Zurich, Rüschli↗

Relic cosmological vector fields and inflationary gravitational waves

Here we show that relic vector fields can significantly impact a spectrum of primordial gravitational waves in the postinflationary era. We consider a triplet of U(1) fields in a homogeneous, isotropic configuration. The interaction between the gravitational waves and the vector fields, from the end of reheating to the present day, yields novel spectral features. The amplitude, tilt, shape, and net chirality of the gravitational wave spectrum are shown to depend on the abundance of the electric- and magneticlike vector fields. Our results show that even a modest abundance can have strong implications for efforts to detect the imprint of gravitational waves on the cosmic microwave background polarization. We find that a vector field comprising less than 2% of the energy density during the radiation-dominated era can have a greater than order unity effect on the predicted inflationary gravitational wave spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultranarrow bandwidth pulses from a regeneratively mode-locked fiber laser

We report on the generation of transform-limited nanosecond pulse with an ultranarrow bandwidth from a regeneratively mode-locked erbium-doped fiber laser. A narrow bandwidth fiber Bragg grating is combined with a bulk amplitude electro-optic modulator to shape pulse evolution inside a ring cavity, and regenerative mode locking is applied to produce a stationary shape of pulses in the nanosecond regime (2.05 ns in duration). Spectral characterization via high bandwidth optoelectronic devices shows that optical pulses have an ultranarrow bandwidth of 220 MHz. Numerical simulation reveals that the shape of the narrow spectral filter has a strong effect on the duration and bandwidth of output pulses.

43 PARTICLE ACCELERATORS↗