Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spallation Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons↗

Conceptual Polarization Setup at CENTAUR, the SANS/WANS Instrument at the Second Target Station of SNS

CENTAUR is a multifunctional general purpose small-angle and wide-angle neutron scattering instrument with diffraction and spectroscopic capability in the future Second Target Station at the Spallation Neutron Source of the Oak Ridge National Laboratory. To fill a gap in neutron polarization capability, the instrument will be designed to provide polarization analysis. Here we present the conceptual polarization setup at CENTAUR, as well as the Spin Echo Modulated Small-Angle Neutron Scattering setup which will further expand the length scale covered by the instrument.

Qian, Shuo↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of the nEDM@SNS light collection system efficiency

Here, a system for collecting the scintillation light produced by the capture of ultra-cold neutrons (UCN) on polarized 3 He is discussed and results from simulations of its performance are presented. This system will be implemented in nEDM@SNS, the experiment searching for the neutron electric dipole moment (nEDM) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Simulation results show that the light collection system detects on average 17 photoelectrons per UCN- 3 He capture event (sufficient to generate a robust signal), reconstructs the event location in the beam direction to approximately 3 cm accuracy, detects capture events with a high and spatially uniform efficiency (0.95 with 1% variation), and rejects greater than 50% of beta decay background events.

47 OTHER INSTRUMENTATION↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulse Shape Discrimination in JSNS 2

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\overline{ν}$ μ → $\overline{ν}$ e appearance oscillations using neutrinos from muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS2 detector is located above ground, on the third floor of the building. We have achieved 94.95% ± 0.15% rejection of neutron events while keeping 92.82% ± 1.77% of signal, electron-like events using a data-driven likelihood method. This article will report the PSD technique using the full fiducial volume of the JSNS2 detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-pressure neutron diffraction at ultra-low temperature

Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 ⁢O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.

Wu, Yan [Oak Ridge National Laboratory (ORNL), Oak↗

Demonstration of a Novel Phase-Space Painting Method in a Coupled Lattice to Mitigate Space Charge in High-Intensity Hadron Beams

Multiturn charge-exchange injection is the primary method of creating high-intensity hadron beams in circular accelerators, and phase space painting during injection enables tailoring of the accumulated phase space distribution. A technique we call eigenpainting allows injection of particles into a single mode of a coupled ring, providing full four-dimensional control of the phase space distribution. Under ideal conditions, uniform eigenpainting generates a linear-force equilibrium distribution in the transverse plane, with zero volume in four-dimensional transverse phase space, even including space charge. Here, we have implemented eigenpainting for the first time in the spallation neutron source accumulator ring. Injecting 8.8 μ⁢C of an 800 MeV beam, we obtain a final ratio of intrinsic transverse emittances of ≈2.4. We analyze the effect of space charge on the final distribution through comparison of the reconstructed phase space to particle-in-cell simulations.

Evans, Nicholas J. [Oak Ridge National Laboratory ↗

First JSNS 2 measurement of the electron neutrino flux using the 12 C⁡(𝜈 𝑒 ,𝑒 − )⁢ 12 N g.s. reaction

JSNS2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment searching for sterile neutrinos through the observation of ν¯μ→ν¯e appearance oscillations, using neutrinos produced by muon decay-at-rest. A key aspect of the experiment involves accurately understanding the neutrino flux and the quantities of pions and muons, which are progenitors of (anti)neutrinos, given that their production rates have yet to be measured. We present the first electron-neutrino flux measurement using C12(νe,e−)12Ng.s. reaction in JSNS2, yielding a flux of (6.7±1.6(stat)±1.7(syst))×10−9 cm−2 proton−1 at the JSNS2 detector location, located at 24 meters distance from the mercury target. This flux measurement is consistent with predictions from simulations based on hadron models.

Particle decays↗

First full Dalitz plot measurement in neutron 𝛽 decay using the Nab spectrometer and implications for new physics

Precision measurements of observables in neutron 𝛽 decay are used to test the standard model description of the weak interaction and search for evidence of new physics. The Nab experiment at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was constructed to measure correlations in neutron decay by utilizing an asymmetric spectrometer and novel detection system to accurately reconstruct the proton momentum and electron energy for each 𝛽 decay. This work describes the detection of neutron 𝛽-decay products in the Nab spectrometer and presents the first full Dalitz plot representation of the phase space of neutron 𝛽 decay for all electrons >100 keV. In addition, new constraints are placed on a possible excited neutron state, hypothesized to explain the disagreement between the appearance and disappearance neutron lifetime techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Four-dimensional phase space tomography from one-dimensional measurements of a hadron beam

In this paper, we use one-dimensional measurements to infer the four-dimensional phase space density of an accumulated proton beam in the Spallation Neutron Source (SNS) accelerator. The reconstruction was performed by maximizing the distribution’s entropy subject to the measurement constraints and thus represents the most conservative inference from the data. The reconstructed distribution reproduces the measured profiles down to the noise level, and simulations indicate that the problem is reasonably well constrained. Similar measurements could serve as benchmarks for beam dynamics simulations in the SNS or hadron accelerators.

43 PARTICLE ACCELERATORS↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗