Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Aqueous alkali metal hydroxide insoluble cellulose ether membrane

A membrane that is insoluble in an aqueous alkali metal hydroxide medium is described. The membrane is a resin which is a water-soluble C2-C4 hydroxyalkyl cellulose ether polymer and an insolubilizing agent for controlled water sorption, a dialytic and electrodialytic membrane. It is particularly useful as a separator between electrodes or plates in an alkaline storage battery.

Hoyt, H. E.↗

Physical aging of linear and network epoxy resins

Network and linear epoxy resins principally based on the diglycidyl ether of bisphenol-A and its oligomers are prepared and studied using diamine and anhydride crosslinking agents. Rubber modified epoxies and a carbon fiber reinforced composite are also investigated. All materials display time-dependent changes when stored at temperatures below the glass transition temperature after quenching (sub-T/g/ annealing). Solvent sorption experiments initiated after different sub-T(g) annealing times demonstrate that the rate of solvent uptake can be indirectly related to the free volume of the epoxy resins. Residual thermal stresses and water are found to have little effect on the physical aging process, which affects the sub-T(g) properties of uniaxial carbon fiber reinforced epoxy material. Finally, the importance of the recovery phenomenon which affects the durability of epoxy glasses is considered.

Kong, E. S.-W.↗

Adsorption and excess fission xenon

The adsorption of Xe and Kr on lunar soil 10084 was measured by a method that employs only very low fractions of monolayer coverage. Results are presented as parameters for calculation of the Henry constant for adsorption as a function of temperature. The adsorption potentials are about 3 kcal/mole for Kr and 5 kcal/mole for Xe; heating the sample in vacuum increased the Xe potential to nearly 7 kcal/mole. Henry constants at the characteristic lunar temperature are about 0.3 cu cm STP/g-atm. These data were applied to consider whether adsorption is important in producing the excess fission Xe effect characteristic of highland breccias. Sorption equilibrium with a transient lunar atmosphere vented fission Xe produces concentrations seven orders of magnitude lower than observed concentrations. Higher concentrations result because of the resistance of the regolith to upward diffusion of Xe. A diffusion coefficient of 0.26 sq cm/sec is estimated for this process.

Podosek, F. A.↗

A research program in determination of heavy metals in sediments and benthic species in relation to nuclear power plant operation

Heavy metals in the estuarine environment can be toxic to fish and shellfish early life history stages and concentrations build up to levels of concern in marketable shellfish. The present survey was begun just before startup in 1974 of the 1900 megawatt Calvert Cliffs Nuclear Power Plant on the Chesapeake Bay in order to assess and understand factors relating to heavy metal accumulation in estuarine biota. Oysters were collected in large numbers at test and reference sites in June 1974 to 77 and individually analyzed for copper and zinc. Oyster copper and zinc concentrations were correlated with salinity read at time of collection. The relationship of oyster age to metal concentration was examined with two sets of oysters of known age and genetic origin (laboratory spawned). Copper sorption by typical mid Bay sediments, and field studies on cadmium concentrations in sediments were examined.

Phelps, H. L.↗

Hydride absorption refrigerator system for ten Kelvin and below

A very long-life, lightweight and efficient hydride absorption refrigerator system was built to operate at ten Kelvin and below. The system consists of four basic stages of refrigeration. The first stage is accomplished by an active refrigeration system. The second stage is operated by a hydride absorption system, wherein a heated hydride powder drives off high pressure hydrogen through a Joule-Thomson/heat exchanger expansion loop such that the hydrogen is partially liquefied. In the third stage, the vapor pressure over the collected liquid hydrogen is lowered by absorbing the hydrogen vapor onto a different low pressure, worn hydride. With a 1.7 torr partial pressure of hydrogen gas in the hydride, liquid hydrogen is solidified and sublimes at 10 K. Long-life adiabatic demagnetization refrigerators, helium desorption, or helium diaphragm compressors are used to cool to 4 K or below. It is shown that the hydride concepts provide an extremely efficient means of refrigeration to 10 K, and that an entire sorption refrigeration process can be accomplished solely by using low grade heat energy at about 150 C.

Jones, J. A.↗

Crystalline-silicon reliability lessons for thin-film modules

The reliability of crystalline silicon modules has been brought to a high level with lifetimes approaching 20 years, and excellent industry credibility and user satisfaction. The transition from crystalline modules to thin film modules is comparable to the transition from discrete transistors to integrated circuits. New cell materials and monolithic structures will require new device processing techniques, but the package function and design will evolve to a lesser extent. Although there will be new encapsulants optimized to take advantage of the mechanical flexibility and low temperature processing features of thin films, the reliability and life degradation stresses and mechanisms will remain mostly unchanged. Key reliability technologies in common between crystalline and thin film modules include hot spot heating, galvanic and electrochemical corrosion, hail impact stresses, glass breakage, mechanical fatigue, photothermal degradation of encapsulants, operating temperature, moisture sorption, circuit design strategies, product safety issues, and the process required to achieve a reliable product from a laboratory prototype.

Ross, R. G., Jr.↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Foliage plants for indoor removal of the primary combustion gases carbon monoxide and nitrogen dioxide

Foliage plants were evaluated for their ability to sorb carbon monoxide and nitrogen dioxide, the two primary gases produced during the combustion of fossil fuels and tobacco. The spider plant (Chlorophytum elatum var. vittatum) could sorb 2.86 micrograms CO/sq cm leaf surface in a 6 h photoperiod. The golden pothos (Scindapsus aureus) sorbed 0.98 micrograms CO/sq cm leaf surface in the same time period. In a system with the spider plant, greater than or equal to 99 percent of an initial concentration of 47 ppm NO2 could be removed in 6 h from a void volume of approximately 0.35 cu m. One spider plant potted in a 3.8 liter container can sorb 3300 micrograms CO and effect the removal of 8500 micrograms NO2/hour, recognizing the fact that a significant fraction of NO2 at high concentrations will be lost by surface sorption, dissolving in moisture, etc.

Wolverton, B. C.↗

The Telecommunications and Data Acquisition Report

Developments in programs managed by the Jet Propulsion Laboratory's Office of Telecommunications and Data Acquisition are discussed. Topics discussed include sorption compression/mechanical expanded hybrid refrigeration, calculated 70-meter antenna performance for offset L-band, systolic arrays and stack decoding, and calibrations of Deep Space Network antennas.

Posner, E. C.↗

Air Force cryocooler development for spacecraft

An overview is given of Air Force sponsored cryocooler development for long duration spacecraft missions. Alternate approaches are being pursued to insure eventual success. The types of closed cycle cryocoolers that are now in advanced development include Vuilleumier, turbo-Brayton, and rotary-reciprocating refrigerators. Linear Stirling coolers with magnetic bearings have also been jointly sponsored by NASA and the Air Force. Technology is also being explored for future coolers using magnetic materials at low temperatures and for refrigerators with sorption compresssors. All of these cryocoolers are presently configured primarily for use with infrared sensor systems, but the designs could be adapted for use with cryogenic fluid storage systems or other applications.

Haskin, William L.↗

Treatment bed microbiological control

The effects of microbial fouling on treatment bed (TB) performance are being studied. Fouling of activated carbon (AC) and ion exchange resins (IEX) by live and devitalized bacteria can cause decreased capacity for selected sorbates with AC and IEX TB. More data are needed on organic species removal in the trace region of solute sorption isotherms. TB colonization was prevented by nonclassical chemical disinfectant compositions (quaternary ammonium resins) applied in suitable configurations. Recently, the protection of carbon beds via direct disinfectant impregnation has shown promise. Effects (of impregnation) upon bed sorption/removal characteristics are to be studied with representative contaminants. The potential need to remove solutes added or produced during water disinfection and/or TB microbiological control must be investigated.

Janauer, Gilbert E.↗

Magnetic-Flux-Compression Cooling Using Superconductors

Proposed magnetic-flux-compression refrigeration system produces final-stage temperatures below 4.2 K. More efficient than mechanical and sorption refrigerators at temperatures in this range. Weighs less than comparable liquid-helium-cooled superconducting magnetic refrigeration systems operating below 4.2 K. Magnetic-flux-compression cooling stage combines advantages of newly discovered superconductors with those of cooling by magnetization and demagnetization of paramagnetic salts.

Strayer, Donald M.↗

Self-actuating heat switches for redundant refrigeration systems

A dual refrigeration system for cooling a sink device is described, which automatically thermally couples the cold refrigerator to the sink device while thermally isolating the warm refrigerator from the sink device. The system includes two gas gap heat switches that each thermally couples one of the refrigerators to the sink device, and a pair of sorption pumps that are coupled through tubes to the heat switches. When the first refrigerator is operated and therefore cold, the first pump which is thermally coupled to it is also cooled and adsorbs gas to withdraw it from the second heat switch, to thereby thermally isolate the sink device from the warm second refrigerator. With the second refrigerator being warm, the second pump is also warm and desorbs gas, so the gas lies in the first switch, to close that switch and therefore thermally couple the cold first refrigerator to the sink device. Thus, the heat switches are automatically switched according to the temperature of the corresponding refrigerator.

Chung K Chan↗

Development of an adsorption compressor for use in cryogenic refrigeration

A new compressor with no moving parts has been developed which is able to supply a source of high-pressure gas to a Joule-Thompson based cryogenic refrigerator. The compressor relies on a newly implemented combination of high-surface-area Saran carbon (sorbent) and krypton gas (working fluid). In addition, an integral gas-gap heat switch is used to provide improved overall efficiency. A prototype compressor has been designed, built, and tested as a part of the Jet Propulsion Laboratory effort in sorption refrigeration. Performance data from the prototype unit described here demonstrate successful compressor performance and good agreement with theoretical predictions.

Schember, Helen R.↗

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗

Experimental studies of circumstellar, interstellar and interplanetary refractory grain analogs

Experimental techniques for studying the processes which occur during the life cycle of a refractory grain are reviewed. Consideration is given to the construction of a differentially-pumped beam-mass spectrometer which is expected to determine the relative stability of small clusters in the Fe-Mg-Si-O and Ca-Ti-Al-O systems as a function of temperature and pressure. Also, a smoke generator has been constructed to produce gram quantities of amorphous grains for use in thermal annealing and hydrous alteration studies of smokes containing Fe-Mg-Al-Ti-Ca-Si-O and Cl. Topics of the studies include the properties of grains produced in a flow condensation apparatus, the sorption efficiency of Si2O3 smokes for AR gas, the processing of ices containing refractory precursors such as SiH4 or Fe(CO)5 plus water, and the residue from 1 MeV bombardment and warming of an amorphous Fe-SiO smoke.

Nuth, J. A.↗

Oscillating Thermal Switch

Proposed heat switch transfers heat from source to sink in regular cycles. Self-sustaining; actuated by transferred heat, contains no moving parts, and needs no external heaters or electronic circuitry to synchronize heat-transfer periods or control heat-transfer rates. Intended for use in gas-sorption refrigerator.

Petrick, S. Walter↗

Reversible Chemisorption Gas-Gap Thermal Switch

Gas/sorbent combinations provide means to turn heat-conduction paths on and off. Single-stage gas-gap thermal switch based on reversible chemisorption of hydrogen gas by ZrNiH. Two-stage gas-gap thermal switch based on reversible desorption of O2 from MnO2 in first stage, followed by absorption in Cu on zeolite in second stage. Requires relatively low power. Used in sorption refrigeration systems designed to operate for long times without maintenance.

Jones, Jack A.↗