Installation package for a solar-heating system
Installation package for solar-powered hot-air system contains such information as operation and maintenance manuals, hardware brochures, schematics, operating mode descriptions, and drawings.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Installation package for solar-powered hot-air system contains such information as operation and maintenance manuals, hardware brochures, schematics, operating mode descriptions, and drawings.
The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.
We investigate the role of high-frequency waves in the heating of solar active region coronal loops. We assume a uniform background magnetic field, and we introduce a density stratification in a direction perpendicular to this field. We focus on ion compressive viscosity as the damping mechanism of the waves. We incorporate viscosity self-consistently into the equations, and we derive a dispersion relation by adopting a slab model, where the density inside the slab is greater than that outside. Such a configuration supports two types of modes: surface waves and trapped body waves. In order to determine under what conditions these waves may contribute to the heating of active regions, we solve our dispersion relation for a range of densities, temperatures, magnetic field strengths, density ratios, wavevector magnitudes, wavevector ratios, and slab widths. We find that surface waves exhibit very small damping, but body waves can potentially damp at rates needed to balance radiative losses. However, the required frequencies of these body waves are very high. For example, the wave frequency must be at least 5.0/s for a slab density of 10(exp 9,5)/cc, a slab temperature of 10(exp 6,5) K, a field strength of 100 G, and a density ratio of 5. For a slab density of 10(exp 10)/cc, this frequency increases to 8.8/s. Although these frequencies are very high, there in no observational evidence to rule out their existence, and they may be generated both below the corona and at magnetic reconnection sites in the corona. However, we do find that, for slab densities of 10(exp 10)/cc or less, the dissipation of high-frequency waves will be insufficient to balance the radiative losses if the magnetic field strength exceeds roughly 200 G. Because the magnetic field is known to exceed 200 G in many active region loops, particularly low-lying loops and loops emanating from sunspots, it is unlikely that high-frequency waves can provide sufficient heating in these regions.
The efficiency at which solar ultraviolet radiation absorbed in the Hartley band of ozone is directly converted to heat in the terrestrial mesosphere and lower thermosphere (50-110 km) is calculated. The ozone molecule undergoes photolysis to yield the excited species O(1D) and O2(1Delta) with a quantum yield of about 0.9. Spontaneous emission from O2(1Delta) and from O2(1Sigma) (excited by energy transfer from O/1D/) significantly decreases the amount of energy available for heat. Similarly, the efficiency at which solar ultraviolet radiation absorbed by O2 in the Schumann-Runge continuum is directly converted to heat in the lower thermosphere (95-110 km) is calculated. The O2 undergoes photolysis and the excited product O(1D) is generated. Spontaneous emission from O2(1Sigma) (excited by energy transfer from O/1D/) reduces the amount of energy available for heat in the lower thermosphere. The consideration of these energy transfer and loss processes results in significantly reduced heating rates as compared to those conventionally calculated in models of the middle atmosphere.
The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.
It has been shown that the coronal hole, and the associated high-speed stream in the solar wind, are powered by a heat input of the order of 500,000 ergs/sq cm s, with most of the heat injected in the first 1-2 solar radii, and perhaps 100,000 ergs/sq cm s introduced at distances of several solar radii to provide the high speed of the issuing solar wind. The traditional view has been that this energy is obtained from Alfven waves generated in the subphotospheric convection, which dissipate as they propagate outward, converting the wave energy into heat. This paper reviews the generation of waves and the known wave dissipation mechanisms, to show that the necessary Alfven waves are not produced under the conditions presently understood to exist in the sun, nor would such waves dissipate significantly in the first 1-2 solar radii if they existed. Wave dissipation occurs only over distances of the order of 5 solar radii or more.
Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.
SHCOST program assesses economic feasibility of solar energy for single-family residences and light commercial applications. Program analyzes life-cycle costs as well as sensitivity studies to aid designer in selecting most economically attractive solar system for single-family residence or light commercial application. SHCOST includes fairly comprehensive list of cost elements from which user may select.
Report evaluates solar-energy system in residential ranger station. Installation provided 22 percent of space-heating and 58 percent of hot-water energy requirements. Annual net energy savings were 30 million Btu. Report describes system and its subsystems: collector array, storage, hot-water, and space-heating. Average weather conditions of test site, performance values, and energy savings are listed.
Solar-assisted hot-water system for a new 122-unit motor inn in Mobile, Alabama, generates more than half the energy needed for hot-water heating at motel each year. System consists of 93 flat-plate collectors, 2,500 gallon (9,500 1) insulated storage tank located outdoors, heat exchangers and controls. Electronic thermometers, measuring the temperatures at 22 locations monitor system performance.
Data needed necessary to evaluate the design and operation of a solar energy heating and hot water system installed in a commercial application are presented. The information includes system descriptions, acceptance test data, schematics, as built drawing, problems encountered, all solutions and photographs of the system at various stages of completion.
The development of twelve prototype solar heating/cooling systems, six heating and six heating and cooling systems, two each for single family, multi-family, and commercial applications, is reported. Schedules and technical discussions, along with illustrations on the progress made from April 1, 1977 through June 30, 1977 are detailed.
Report describes solar-energy system for 50 seat observatory that provides 60 percent of space heating needs. System includes 9 flat-plate collectors, rock storage bin, blowers, controls, ducting, and auxiliary natural-gas furnace; it has five operation modes. Net energy savings were 11.31 million Btu for 12 months, or equivalent of 1.9 barrels of oil. Report appendixes list performance factor definitions, performance equations, and average area weather conditions.
Progress made in the development of a solar hot water and space heating system is described in four quarterly reports. The program schedules, technical status and other program activities from 6 October 1976 through 30 September 1977 are provided.
A hot air solar system which utilizes flat plate air collectors is discussed. Collector areas for each of four buildings cover 780 sq ft, with storage capacity of 390 cu ft per building. The air system has a special air handling unit to move air through the collectors and into and out of the rock storage, with connection to the air duct distribution system. The heat of the motor is added to the heat delivered to the system. The solar system also includes four motorized special low leakage dampers and two gravity fabric dampers. The system is automatically controlled by a solid state controller with three thermistors: one located in the collectors, one in the rock box to plenum, one in the return air duct from the heated space. A three stage heating thermostat, located in the conditioned space, controls the operation.
The acquisition and processing of selected parametric data for inclusion in a computerized Data Base using the Marshall Information Retrieval and Data System (MIRADS) developed by NASA-MSFC is discussed. This data base provides extensive technical and socioeconomic information related to solar energy heating and cooling on a national scale. A broadly based research approach was used to assist in the support of program management and the application of a cost-effective program for solar energy development and demonstration.
Report describes comprehensive performance tests of complete solar powered space and hot water heating system to verify its suitability for field installation in small single family dwellings.
The solar energy system located at the North Dallas High School, Dallas, Texas is discussed. The system is designed as a retrofit in a three story with basement, concrete frame high school building. Extracts from the site files, specification references for solar modification to existing building heating and domestic hot water systems, drawings, installation, operation and maintenance instructions are included.