Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Smoke Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Using Satellite‐Derived Fire Arrival Times for Coupled Wildfire‐Air Quality Simulations at Regional Scales of the 2020 California Wildfire Season

Abstract Wildfire frequency has increased in the Western US over recent decades, driven by climate change and a legacy of forest management practices. Consequently, human structures, health, and life are increasingly at risk due to wildfires. Furthermore, wildfire smoke presents a growing hazard for regional and national air quality. In response, many scientific tools have been developed to study and forecast wildfire behavior, or test interventions that may mitigate risk. In this study, we present a retrospective analysis of 1 month of the 2020 Northern California wildfire season, when many wildfires with varying environments and behavior impacted regional air quality. We simulated this period using a coupled numerical weather prediction model with online atmospheric chemistry, and compare two approaches to representing smoke emissions: an online fire spread model driven by remotely sensed fire arrival times and a biomass burning emissions inventory. First, we quantify the differences in smoke emissions and timing of fire activity, and characterize the subsequent impact on estimates of smoke emissions. Next, we compare the simulated smoke to surface observations and remotely sensed smoke; we find that despite differences in the simulated smoke surface concentrations, the two models achieve similar levels of accuracy. We present a detailed comparison between the performance and relative strengths of both approaches, and discuss potential refinements that could further improve future simulations of wildfire smoke. Finally, we characterize the interactions between smoke and meteorology during this event, and discuss the implications that increases in regional smoke may have on future meteorological conditions.

54 ENVIRONMENTAL SCIENCES↗

Application of Infrared Scanners to Forest Fire Detection

The potential of using infrared scanners for the detection of forest fires is discussed. An experiment is described in which infrared and visual detection systems were used jointly to study timber fire detection. Many fires were detected visually but missed by the airborne IR system, and many fires were detected by the IR system but missed visually. Until more is learned about the relationship between heat output and smoke output from latent fires, the relative effectiveness of visual and IR systems cannot be determined. The 1970 tests indicated that IR used in combination with visual detection will result in a more efficient system than visual alone. Even with limited knowledge of the relative effectiveness of the two systems, operational use of a combined system can be used to substantially reduce total firefighting costs.

Hirsch, S. N.↗

Combined Retrievals of Boreal Forest Fire Aerosol Properties with a Polarimeter and Lidar

Absorbing aerosols play an important, but uncertain, role in the global climate. Much of this uncertainty is due to a lack of adequate aerosol measurements. While great strides have been made in observational capability in the previous years and decades, it has become increasingly apparent that this development must continue. Scanning polarimeters have been designed to help resolve this issue by making accurate, multi-spectral, multi-angle polarized observations. This work involves the use of the Research Scanning Polarimeter (RSP). The RSP was designed as the airborne prototype for the Aerosol Polarimetery Sensor (APS), which was due to be launched as part of the (ultimately failed) NASA Glory mission. Field observations with the RSP, however, have established that simultaneous retrievals of aerosol absorption and vertical distribution over bright land surfaces are quite uncertain. We test a merger of RSP and High Spectral Resolution Lidar (HSRL) data with observations of boreal forest fire smoke, collected during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS). During ARCTAS, the RSP and HSRL instruments were mounted on the same aircraft, and validation data were provided by instruments on an aircraft flying a coordinated flight pattern. We found that the lidar data did indeed improve aerosol retrievals using an optimal estimation method, although not primarily because of the constraints imposed on the aerosol vertical distribution. The more useful piece of information from the HSRL was the total column aerosol optical depth, which was used to select the initial value (optimization starting point) of the aerosol number concentration. When ground based sun photometer network climatologies of number concentration were used as an initial value, we found that roughly half of the retrievals had unrealistic sizes and imaginary indices, even though the retrieved spectral optical depths agreed within uncertainties to independent observations. The convergence to an unrealistic local minimum by the optimal estimator is related to the relatively low sensitivity to particles smaller than 0.1 ( m) at large optical thicknesses. Thus, optimization algorithms used for operational aerosol retrievals of the fine mode size distribution, when the total optical depth is large, will require initial values generated from table look-ups that exclude unrealistic size/complex index mixtures. External constraints from lidar on initial values used in the optimal estimation methods will also be valuable in reducing the likelihood of obtaining spurious retrievals.

Knobelspiesse, K.↗

Optical and probe determination of soot concentrations in a model gas turbine combustor

An experimental program was conducted to track the variation in soot loading in a generic gas turbine combustor. The burner is a 12.7-cm dia cylindrical device consisting of six sheet-metal louvers. Determination of soot loading along the burner length is achieved by measurement at the exit of the combustor and then at upstream stations by sequential removal of liner louvers to shorten burner length. Alteration of the flow field approaching and within the shortened burners is minimized by bypassing flow in order to maintain a constant linear pressure drop. The burner exhaust flow is sampled at the burner centerline to determine soot mass concentration and smoke number. Characteristic particle size and number density, transmissivity of the exhaust flow, and local radiation from luminous soot particles in the exhaust are determined by optical techniques. Four test fuels are burned at three fuel-air ratios to determine fuel chemical property and flow temperature influences. Particulate concentration data indicate a strong oxidation mechanism in the combustor secondary zone, though the oxidation is significantly affected by flow temperature. Soot production is directly related to fuel smoke point.

Eckerle, W. A.↗

Flight test investigation of the vortex wake characteristics behind a Boeing 727 during two-segment and normal ILS approaches

A series of flight tests were performed to evaluate the vortex wake characteristics of a Boeing 727 (B727-200) aircraft during conventional and two-segment ILS approaches. Flights of the B727, equipped with smoke generators for vortex marking, were flown wherein its vortex wake was intentionally encountered by a Lear Jet model 23 (LR-23) or a Piper Twin Comanche (Pa-30); and its vortex location during landing approach was measured using a system of photo-theodolites. The tests showed that at a given separation distance there were no differences in the upsets resulting from deliberate vortex encounters during the two types of approaches. Timed mappings of the position of the landing configuration vortices showed that they tended to descend approximately 91 meters (300 feet) below the flight path of the B727. The flaps of the B727 have a dominant effect on the character of the trailed wake vortex. The clean wing produces a strong, concentrated vortex. As the flaps are lowered, the vortex system becomes more diffuse. Pilot opinion and roll acceleration data indicate that 4.5 nautical miles would be a minimum separation distance at which roll control could be maintained during parallel encounters of the B727's landing configuration wake by small aircraft.

Garodz, L. J.↗

Test technique development in interference free testing, flow visualization, and remote control model technology at Langley's Unitary Plan wind tunnel

A metric half-span model is considered as a means of mechanical support for a wind-tunnel model which allows measurement of aerodynamic forces and moments without support interference or model distortion. This technique can be applied to interference-free propulsion models. The vapor screen method of flow visualization at supersonic Mach numbers is discussed. The use of smoke instead of water vapor as a medium to produce the screen is outlined. Vapor screen data are being used in the development of analytical vortex tracking programs. Test results for a remote control model system are evaluated. Detailed control effectiveness and cross-coupling data were obtained with a single run. For the afterbody tail configuration, tested control boundaries at several roll orientations were established utilizing the facility's on-line capability to 'fly' the model in the wind tunnel.

Corlett, W. A.↗

Analyzing Wildland Fire Smoke Emissions Data Using Compositional Data Techniques

By conservation of mass, the mass of wildland fuel that is pyrolyzed and combusted must equal the mass of smoke emissions, residual char and ash. For a given set of conditions, these amounts are fixed. This places a constraint on smoke emissions data which violates statistical assumptions for many of the methods currently used to analyze these data such as linear regression, analysis of variance, and t-tests. These data are inherently multivariate and non-negative parts of a whole. This paper introduces the field of compositional data analysis to the emissions community and provides examples of appropriate statistical treatment of emissions data. It is shown that modified combustion efficiency should not be used as a predictor variable for other smoke emissions because it is not an independent variable. An alternative method based on compositional linear trends to estimate trace gas composition using CO and CO2 is presented. The data used in this paper resulted from projects the DOD/DOE/EPA Strategic 586 Environmental Research and Development Program projects RC-1648 and 1649. The senior 587 author appreciates the guidance and R scripts provided by Prof. Girty at San Diego State 588 University to estimate linear trends by perturbation. J. P.-A. was supported by the Spanish 589 Ministry of Science, Innovation and Universities under the project CODAMET (RTI2018-590 095518-B-C21, 2019-2021). The data used in this study have been previously published and are 591 available in the original publications. DRW conceived the initial manuscript (70 percent) and 592 performed the bulk of the data analysis. JPA provided statistical guidance and compositional data 593 expertise and contributed 20 percent of the manuscript. TJJ and HJ were extensively involved in 594 the study that provided the data. TJJ provide smoke emissions expertise and HJ provided 595 combustion expertise. The authors declare that they have no conflict of interest. The use of trade 596 or firm names in this publication is for reader information and does not imply endorsement by 597 the U.S. Department of Agriculture of any product or service.

simplex, compositional data analysis, balance, log↗

Evaluation of Federal Aviation Administration ion engine exhaust sampling rake

A FAA exhaust emissions rake was tested in the Experimental Clean Combustor Program, Phase 3 to permit comparison of the values of gaseous emissions and smoke measured by the FAA rake with those measured with the NASA Pratt and Whitney Aircraft (P and WA) rake used in the Phase 3 Experimental Clean Combustor Program and with station seven probes. The results showed that the levels of CO, THC, NOx and smoke measured by the FAA and NASA/P and WA rakes agree well at high power, but that CO emissions measured by the FAA rake were approximately 10 percent higher than those measured by the NASA/P and WA rake at low power.

Fiorentino, A. J.↗

Combustion characteristics of hydrogen-carbon monoxide based gaseous fuels

The results of trials with a staged combustor designed to use coal-derived gaseous fuels and reduce the NO(x) emissions from nitrogen-bound fuels to 75 ppm and 37 ppm without bound nitrogen in 15% O2 are reported. The combustor was outfitted with primary zone regenerative cooling, wherein the air cooling the primary zone was passed into the combustor at 900 F and mixed with the fuel. The increase in the primary air inlet temperature eliminated flashback and autoignition, lowered the levels of CO, unburned hydrocarbons, and smoke, and kept combustion efficiencies to the 99% level. The combustor was also equipped with dual fuel injection to test various combinations of liquid/gas fuel mixtures. Low NO(x) emissions were produced burning both Lurgi and Winkler gases, regardless of the inlet pressure and temperature conditions. Evaluation of methanation of medium energy gases is recommended for providing a fuel with low NO(x) characteristics.

White, D. J.↗

Vortex flow hysteresis

An experimental study was conducted to quantify the hysteresis associated with various vortex flow transition points and to determine the effect of planform geometry. The transition points observed consisted of the appearance (or disappearance) of trailing edge vortex burst and the transition to (or from) flat plate or totally separated flows. Flow visualization with smoke injected into the vortices was used to identify the transitions on a series of semi-span models tested in a low speed tunnel. The planforms tested included simple deltas (55 deg to 80 deg sweep), cranked wings with varying tip panel sweep and dihedral, and a straked wing. High speed movies at 1000 frames per second were made of the vortex flow visualization in order to better understand the dynamics of vortex flow, burst and transition.

Cunningham, A. M., Jr.↗

Smoke-Point Properties of Nonbuoyant Round Laminar Jet Diffusion Flames

The laminar smoke-point properties of non-buoyant round laminar jet diffusion flames were studied emphasizing results from long-duration (100-230 s) experiments at microgravity carried out in orbit aboard the space shuttle Columbia. Experimental conditions included ethylene- and propane-fueled flames burning in still air at an ambient temperature of 300 K, pressures of 35-130 kPa, jet exit diameters of 1.6 and 2.7 mm, jet exit velocities of 170-690 mm/s, jet exit Reynolds numbers of 46-172, characteristic flame residence times of 40-302 ms, and luminous flame lengths of 15-63 mm. Contrary to the normal-gravity laminar smoke point, in microgravity the onset of laminar smoke-point conditions involved two flame configurations: closed-tip flames with soot emissions along the flame axis and open-tip flames with soot emissions from an annular ring about the flame axis. Open-tip flames were observed at large characteristic flame residence times with the onset of soot emissions associated with radiative quenching near the flame tip: nevertheless, unified correlations of laminar smoke-point properties were obtained that included both flame configurations. Flame lengths at laminar smoke-point conditions were well correlated in terms of a corrected fuel flow rate suggested by a simplified analysis of flame shape. The present steady and nonbuoyant flames emitted soot more readily than non-buoyant flames in earlier tests using ground-based microgravity facilities and than buoyant flames at normal gravity, as a result of reduced effects of unsteadiness, flame disturbances, and buoyant motion. For example, present measurements of laminar smokepoint flame lengths at comparable conditions were up to 2.3 times shorter than ground-based microgravity measurements and up to 6.4 times shorter than buoyant flame measurements. Finally, present laminar smoke-point flame lengths were roughly inversely proportional to pressure to a degree that is a somewhat smaller than observed during earlier tests both at microgravity (using ground-based facilities) and at normal gravity,

Urban, D. L.↗

Vortex Wake Turbulence: Flight Tests Conducted During 1970

A flight test program designed to obtain data on the characteristics of wing-tip vortices generated by large jet aircraft was initiated on 12 February 1970. The objective was to update the interim air traffic separation standards issued on 21 January 1970 restricting the airspace behind the B-747 and C-5A aircraft 60 deg either side and 2,000 feet below to a distance of 10 miles. The program involved flight tests at three different locations, which were conducted simultaneously. (1) At the Edwards Air Force Base test range, a NASA CV-990 and F-104 probed the vortices of a C-5A. This supplemented previous flight tests in U-3A and F-104 behind a B-52 and C-5A. (2) At Seattle, the Boeing Company probed the vortices of a B-747 and a B-707-300 with a B-737 and F-86. In addition, approach, landing, takeoff, and crossing runway tests were conducted with a B-737 trailing a B-747. Immediately following the Edwards tests, the NASA CV-990 proceeded to Seattle and engaged in probing flights behind the same B-747 and B-707-300. (3) At Idaho Falls, Idaho, FAA personnel, utilizing the Atomic Energy Commission and Environmental Science Services Administration facilities and a 200 ft, instrumented tower, conducted 114 flights past the tower. The aircraft were positioned to permit their vortices to descend into the air flow sensors and smoke generated from various levels on the tower. This permitted obtaining measurements and photography of the vortex core diameters, tangential velocities and related characteristics. Immediately following this test phase, analysis of the interrelated data was completed by the project managers representing NASA, Boeing and FAA and a Compilation of Work Papers was issued on 30 April 1970. These data were the basis of a revised General Notice issued on 26 February 1970 which, in essence, modified the restricted airspace to five miles behind heavy jets in the 300,000 lb. gross takeoff weight category.

Source record↗

Characteristics of wake vortex generated by a Boeing 727 jet transport during two-segment and normal ILS approach flight paths

A series of flight tests was conducted to evaluate the vortex wake characteristics of a Boeing 727 (B727-200) aircraft during conventional and two-segment ILS approaches. Twelve flights of the B727, which was equipped with smoke generators for vortex marking, were flown and its vortex wake was intentionally encountered by a Lear Jet model 23 (LR-23) and a Piper Twin Comanche (PA-30). Location of the B727 vortex during landing approach was measured using a system of photo-theodolites. The tests showed that at a given separation distance there were no readily apparent differences in the upsets resulting from deliberate vortex encounters during the two types of approaches. Timed mappings of the position of the landing configuration vortices showed that they tended to descend approximately 91 m(300 ft) below the flight path of the B727. The flaps of the B727 have a dominant effect on the character of the trailed wake vortex. The clean wing produces a strong, concentrated vortex but as the flaps are lowered, the vortex system becomes more diffuse. Pilot opinion and roll acceleration data indicate that 4.5 n.mi. would be a minimum separation distance at which roll control of light aircraft (less than 5,670 kg (12,500 lb) could be maintained during parallel encounters of the B727's landing configuration wake. This minimum separation distance is generally in scale with results determined from previous tests of other aircraft using the small roll control criteria.

Kurkowski, R. L.↗

Soot loading in a generic gas turbine combustor

Variation in soot loading along the centerline of a generic gas turbine combustor was experimentally investigated. The 12.7-cm dia burner consisted of six sheet-metal louvers. Soot loading along the burner length was quantified by acquiring measurements first at the exit of the full-length combustor and then at upstream stations by sequential removal of liner louvers to shorten the burner length. Alteration of the flow field approaching removed louvers, maintaining a constant liner pressure drop. Burner exhaust flow was sampled at the burner centerline to determine soot mass concentration and smoke number. Characteristic particle size and number density, transmissivity of the exhaust flow, and local radiation from luminous soot particles in the exhaust flow were determined by optical techniques. Four test fuels were burned at three fuel-air ratios to determine fuel chemical property and flow temperature influences. Data were acquired at two combustor pressures. Particulate concentration data indicated a strong oxidation mechanism in the combustor secondary zone, though the oxidation was significantly affected by flow temperature. Soot production was directly related to fuel smoke point. Less soot production and lower secondary-zone oxidation rates were observed at reduced combustor pressure.

Eckerle, W. A.↗

Evaluation of Wiring Constructions for Space Applications

A NASA Office of Safety and Mission Assurance (OS&MA) program to develop lightweight, reliable, and safe wiring insulations for aerospace applications is being performed by the NASA Lewis Research Center (LeRC). As part of this effort, a new wiring construction utilizing high strength PTFE (poly tetrafluoroethylene) as the insulation has been tested and compared with the existing military standard polyimide-based MIL-W-81381 wire construction. Electrical properties which were investigated included ac corona inception and extinction voltages (sea level and 60,000 feet), time/current to smoke, and wire fusing time. The two constructions were also characterized in terms of their mechanical properties of flexural strength, abrasion resistance (23 C and 150 C), and dynamic cut-through (23 C and 200 C). The results obtained in this testing effort are presented and discussed in this paper.

Hammoud, Ahmad N.↗

Effect of tip vanes on the performance and flow field of a rotor in hover

Tests run with a single bladed model rotor with a vane located at the tip of the blade indicated significantly increased performance under certain test conditions. Data reveal that a figure of merit increase of over one third occurred in hover. Flow visualization using smoke revealed that a pair of vortices sprung from the blade tip and the vane tip. The vane tip vortex tended to roll up and over the primary vortex. The vortices in the wake became much less well defined with the tip vane configurations.

Velkoff, H. R.↗

Firefly system concept

The 'Firefly' project has developed and implemented an infrared (IR) remote sensing prototype system based on the concept presented. The Firefly system produces images through smoke that will provide near real-time wildland fire information for fire management and suppression. The prototype will be tested through the 1991 fire season. Results of the testing will be incorporated into the final system design for operational use at the end of 1992.

Nichols, J. D.↗