Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation Cases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Modeling and Optimal Design of a Desalination System Integrated Between a Glass-Covered Solar Collection Water Chamber and a Heat Dissipating Chimney

Abstract Solar thermal energy is trapped in a glass-covered water chamber/basin to provide the heat for evaporation of brackish water in a novel desalination system. To harvest clean water, a chimney is integrated with the water basin, which draws air into the chamber to be humidified by the vapor and then being ventilated via buoyance force. Uniquely, thermal conductive metal sheet is recommended to make the chimney, which allows the vapor in the humid air condenses easily when flowing up. The condensate at the inner wall of the chimney flows down to be collected as clean water. Mathematical modeling and numerical computation have been carried out to delineate the coupling of the buoyance-force-driven flow with the heat and mass transfer of air and water in the solar collection chamber and the condensation of vapor in the heat-dissipating chimney. The objective of the simulation and optimization of the system is to find the best match of the dimensions of the water chamber with a chimney to maximize the production of clean water and energy efficiency. The model has been used to simulation several cases (of water from 40 °C to 50 °C) with available experimental data from the authors’ previous work, and the agreement was satisfactory. The optimization studies found that there is a maximum air flowrate corresponding to a critical chimney height due to the requirement that the chimney is designated to dissipate heat as much as possible to condense water vapor. With the chimney height greater than the critical height, the airflow rate will have a slight decrease. Nevertheless, higher than a critical height is still needed for a chimney to condense more moisture. Optimized chamber diameters at different chimney heights are provided for reference of optimal system designs.

Engineering↗

Development of in-use engine speed/torque heat maps across multiple heavy-duty commercial vehicle vocations

The U.S. Department of Energy (DOE) established the SuperTruck program with the goal of achieving brake thermal efficiency (BTE) greater than or equal to 55% as demonstrated in an operational heavy-duty (HD) diesel engine at a 65-miles-per-hour (mph) cruise point. Beyond the line-haul application, HD engines operate in a wide range of speed and torque conditions that are unlikely to yield the same efficiency under real-world operation. Thereby, the in-use engine heat maps described in this paper are a valuable tool to illustrate whether the engine-efficiency “sweet spot” matches the most frequent operating conditions. In this study, NREL developed engine heat maps to quantify the important operating points for various vocations using our Fleet DNA database of commercial fleet vehicle operations data. These heat maps clearly show that high-frequency operating points vary significantly according to vehicle vocation, while only a few of them match the sweet spot. Beyond the illustration, engine in-use heat maps can also be leveraged to build up reduced-order engine-efficiency models, needed by many rapid powertrain simulations. As case studies, nine reduced-order models – including line-haul truck, transfer truck, transit bus, transit bus with compressed natural gas (CNG) engine, drayage, refuse pickup, local delivery, utility truck, and school bus with CNG engine – using a trust-region reflective algorithm to fit the on-road data extracted based on the engine in-use heat maps.

33 ADVANCED PROPULSION SYSTEMS↗

Advancing representations of turbulence in Earth System Models [Slides]

We have created a suite of coastally focused Large Eddy Simulation (LES), including a first ever investigation of the influence of the ocean bottom on turbulence. We have added important forcing not previously considered in LES models. We have evaluated a new more physically realistic and advanced closure against our LES database of simulations. Test cases will constrain constants in the new model and help us transition the mixing model from the deep ocean to the coastal ocean for the first time.

58 GEOSCIENCES↗

Posterior Regularized Bayesian Neural Network

Traditional NNs often lack the ability for uncertainty quantification. Bayesian NNs(BNNs) could help measure the confidence level by using distributions in NNs modeling. Besides, knowledge is commonly available and could improve the performance of BNNs if it can be properly incorporated. In this work, we propose a novel Posterior-Regularized BNN(PR-BNN) model by incorporating soft and hard constraints as a posterior regularization term. We also propose an augmented Lagrangian method and stochastic optimization algorithm for efficient updating via Monte Carlo sampling. The simulations and case studies for solar PV plants have shown the performance improvement of the proposed model over traditional BNNs.

97 MATHEMATICS AND COMPUTING↗

ETF Grout Expansion: Evaluation of MgO Additions and Struvite Precipitation Protocol for Potential Expansion

The ETF ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during solidification of an ammonium-rich, concentrated sulfate aqueous waste stream generated at the Hanford Effluent Treatment Facility (ETF). VSL did not observe expansion in samples prepared during the waste form development work. However, Savannah River National Laboratory (SRNL) personnel did encounter expansion, in some cases up to 20+ volume percent expansion in ETF grout samples while preforming work scope to evaluate compositional ranges for ETF brine and of the precipitation and solidification reagent. The work requests can be found in Washington River Protection Services (WRPS) Statement of Work (SOW), Requisitions #: 339922 Revisions 0 and 1, March 11, 2021, and November 2021. Additional evaluation was requested by WRPS SOW Requisitions #: 356730, Revision 1, February 1, 2022, to determine whether differences in the slags or differences in sample preparation protocols used by VSL and SRNL were the cause of the expansion observed in the SRNL samples. G. Chen, WRPS, arranged a materials exchange between VSL and SRNL and coordinated the VSL protocol for grouting and curing 1L of Base Case ETF simulant. Materials were exchanged between VSL and SRNL and both laboratories performed the VSL struvite precipitation-solidification protocol and cured samples for at least 28 days. VSL and SRNL encountered expansion, at varying degrees, in all samples prepared under the material exchange and grouting protocol. Additional material exchange testing between VSL and SRNL and alternative materials evaluation to further investigate the causes of grout expansion and differentiate the effects of various dry materials, grouting procedures, and curing containers was requested by WRPS SOW Requisitions #: 356730, Revision 2, January 10, 2023. Pacific Northwest National Laboratory (PNNL) assembled and distributed materials to both laboratories for testing. Observations from this study indicated variations in MgO additions, water-to-dry mix (dm) ratios and curing containers did not correlate to ETF ammonia grout expansion. In comparison to previous work, SRNL observed the addition rate of NaOH to be a potential factor for the final pH in the struvite precipitation step. In the current testing NaOH was added in bulk (5-10 mL at one time) during the precipitation step. The resulting pH was 7.57-9.15 which is slightly higher than pH observed at a slower addition rate. Additional testing is needed to identify the presence and/or struvite stability in high-pH struvite precipitant ETF ammonia grout samples. Therefore, based on current data, it is unknown if NaOH addition rate is the fundamental cause of grout expansion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Samoa Updater: An Application of the Levenberg-Marquardt Method to Update DELFIC Predictions Using Field Measurements

The US Department of Energy (DOE) Forensics Operations (DFO) is a member of the Ground Collections Task Force (GCTF), which is responsible for sample collection of radiological debris for attribution should a nuclear detonation ever occur in the United States. The DFO runs the Defense Land Fallout Interpretive Code (DELFIC) Fallout Planning Tool to predict the deposition of fallout from a nuclear detonation. This prediction is refined using the DELFIC Updater tool, which takes ground measurements and adjusts DELFIC inputs to minimize the difference between prediction and observation, yielding improved predictions of fallout in locations both measured and not yet measured. Samoa, a framework for uncertainty analysis and optimization, is used to improve DELFIC predictive fallout modeling. This new capability using Samoa, dubbed “Samoa Updater,” is compared with the current DELFIC Updater, a brute-force sampling approach. Samoa Updater uses the Levenberg– Marquardt (LM) method, a gradient-based nonlinear least squares approach that uses the functional shape of the input space to increase optimization speed. In simulated test cases Samoa Updater yields faster and more accurate solutions than the current Updater.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pressure Exchanger for Energy Recovery in a Trans-Critical CO2 Refrigeration System

Trans-critical CO2 vapor compression (VC) refrigeration cycles require a high compression ratio, which is associated with high expansion losses. To recover these expansion losses, a pressure exchange process between the low- and high-pressure sides of the VC cycle is proposed and examined in this study. The proposed pressure exchange system is an open type constant volume process where the high- and low-pressure flows mix inside the system. This prototype is inspired by the pressure exchangers used in reverse-osmosis (RO) desalination systems. In this system, a 2D model was generated and modeled using the computational fluid dynamics (CFD) technique. The numerical model ignored any losses due to leakage or hydraulic friction and the process is considered adiabatic. For the modeling, it was assumed that the inlet conditions for the two pressure exchanger flows are similar to the flow conditions at the evaporator and gas cooler outlets in a VC cycle. Two parameters are examined to test the validity of the system and understand their effect on the performance, including the inlet flow rate represented by the inlet velocity and the process time represented by the speed of rotation. A total of nine cases were simulated and analyzed in this study.

30 DIRECT ENERGY CONVERSION↗

A Sustainable Wind–Biogas Hybrid System for Remote Areas in Jordan: A Case Study of Mobile Hospital for a Zaatari Syrian Refugee Camp

Access to reliable and sustainable energy in remote areas remains a pressing global challenge, significantly affecting economic development and the quality of life. This study focuses on the implementation of fully off-grid wind–biogas hybrid power systems to address this issue, with a focus on remote healthcare camp facilities. This paper investigates the performance of a hybrid renewable energy system within the context of one of Jordan’s northern remote areas, the Zaatari Syrian Refugee Camp, assessing its efficiency and environmental impact by taking the Zaatari hospital as the case study. Simulations were conducted to evaluate system components, including wind turbines, biogas generators, and diesel generators. A comprehensive evaluation was conducted, encompassing both the operational efficiency of the system and its impact on the environment. This study also considered various scenarios (SC#), including grid availability and autonomy levels, to optimize system configurations. The techno-economic assessment employed the levelized cost of energy (LCOE) as a key performance indicator, and sensitivity analyses explored the impact of diesel costs and wind power fluctuations on the system. Additionally, environmental assessment was conducted to evaluate the environmental effects of hybrid systems, with a specific focus on reducing greenhouse gas emissions. This investigation involved an examination of emissions in three different scenarios. The results indicate that the lowest LCOE that could be achieved was 0.0734 USD/kWh in SC#1 with 72.42% autonomy, whereas achieving 100% autonomy increased the LCOE to 0.1756 USD/kWh. Additionally, the results reveal that in scenarios SC#2 and SC#3, which have a higher proportion of diesel generator usage, there were elevated levels of NO x and CO 2 emissions. Conversely, in SC#1, which lacks diesel generators, emissions were notably lower. The proposed hybrid system demonstrates its potential to provide a reliable energy supply to healthcare facilities in remote regions, emphasizing both economic feasibility and environmental benefits. These findings contribute to informed decision making for sustainable energy solutions in similar contexts, promoting healthcare accessibility and environmental sustainability.

09 BIOMASS FUELS↗

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

Nonlinear power flow control for networked AC/DC microgrids

A method for designing feedforward and feedback controllers for integration of stochastic sources and loads into a nonlinear networked AC/DC microgrid system is provided. A reduced order model for general networked AC/DC microgrid systems is suitable for HSSPFC control design. A simple feedforward steady state solution is utilized for the feedforward controls block. Feedback control laws are provided for the energy storage systems. A HSSPFC controller design is implemented that incorporates energy storage systems that provides static and dynamic stability conditions for both the DC random stochastic input side and the AC random stochastic load side. Transient performance was investigated for the feedforward/feedback control case. Numerical simulations were performed and provided power and energy storage profile requirements for the networked AC/DC microgrid system overall performance. The HSSPFC design can be implemented in the Matlab/Simulink environment that is compatible with real time simulation/controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Posterior Regularized Bayesian Neural Network

Traditional NNs often lack the ability for uncertainty quantification. Bayesian NNs(BNNs) could help measure the confidence level by using distributions in NNs modeling. Besides, knowledge is commonly available and could improve the performance of BNNs if it can be properly incorporated. In this work, we propose a novel Posterior-Regularized BNN(PR-BNN) model by incorporating soft and hard constraints as a posterior regularization term. We also propose an augmented Lagrangian method and stochastic optimization algorithm for efficient updating via Monte Carlo sampling. The simulations and case studies in solar energy prediction have shown the performance improvement of the proposed model over traditional BNNs.

14 SOLAR ENERGY↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Study of Financial Impacts of Pooled Rideshare Based on Assignment Strategies

This study explores the potential profitability of a pooled rideshare service in a simulation-based case study of two US metropolitan regions in the context of two fleet assignment strategies. A new method of obtaining more accurate fares is created to address scalability and accuracy assumptions relevant to pooling choice. Cases for private rideshare fleets, public mobility on demand offerings, and autonomous fleets are explored and analyzed. Two regions of differing types are explored to illustrate the impacts of geo-spatial demand density of profitability, with one region capturing a large urban and suburban environment and the second a less dense more compact small city. Results indicate that the cost of human drivers is prohibitively expensive, and regulation of driver pay extends the issue of financial viability. Despite these shortcomings, a more efficient rideshare assignment strategy is shown to increase profitability by as much as 60%. The smaller, more dense region was illustrated to experience a greater increase in profitability than the larger region when pooling was improved.

Paul, Joseph↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau to River Groundwater Model (P2R Model) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by CH2M HILL Plateau Remediation Company at the Hanford Site in Washington State. Figure 1-1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3, documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation is to describe the application of the hydraulic property fields and recharge parameters documented in ECF-HANFORD-20-0027, Null Space Monte Carlo Evaluation of the Plateau to River Model, to the CA flow and fate and transport simulation results to quantify the uncertainty in the simulated results due to input parameter selection. Use of numerical groundwater models is always accompanied with uncertainty in the results produced by a model because models are approximations of reality. Thus, by definition, models lack the detail to fully represent observed behavior. Use of numerical techniques, such as a NSMC analysis, can help in identifying and quantifying the potential uncertainties associated with a numerical model such as the P2R Model. The result of NSCM analysis is a set of F&T simulations that provide an estimate of the range of possible outcomes that are used to quantify the uncertainty in simulated concentrations produced using the base case simulations. The simulated concentrations from all simulations will support calculation of the uncertainty of the total dose calculated in a separate calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Validation of Hermes-3 turbulence simulations against the TCV-X21 diverted L-mode reference case

Electrostatic flux-driven turbulence simulations with the Hermes-3 code are performed in TCV L-mode conditions in forward and reversed toroidal field configurations, and compared to the TCV-X21 reference dataset (Oliveira et al 2022 Nucl. Fusion 62 096001) qualitatively and with a quantitative methodology. Using only the magnetic equilibrium, total power across the separatrix (120 kW) and total particle flux to the targets (3 x 10 21 s −1 ) as inputs, the simulations produce time-averaged plasma profiles in good agreement with experiment. Shifts in the target peak location when the toroidal field direction is reversed are reproduced in simulation, including the experimentally observed splitting of the outer strike point into two density peaks. The overall normalized discrepancy between simulation and observation is better than any previously reported in the reversed field configuration, and matches the best previously reported in forward field configuration. Differences between simulation and experiment include density profiles inside the separatrix and at the inner target in forward (favorable $\bigtriangledown B$) field configuration. These differences in target temperature in forward field configuration lead to differences in the balance of current to the inner and outer divertor in the private flux region. The cause of these differences is most likely the lack of neutral gas in these simulations, indicating that even in low recycling regimes neutral gas plays an important role in determining edge plasma profiles. These conclusions are consistent with findings in Oliveira et al (2022 https://github.com/SPCData/TCV-X21).

Physics - Plasma physics↗