Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multiscale cohesive zone model for propagation of segmented crack fronts in mode I+III fracture

Quasistatic crack propagation in mixed-mode I+III fracture is widely observed to be unstable, the instability being characterized by the segmentation of the parent crack into a periodic array of daughter cracks shaped as flat facets rotated towards the principal stress axis. While there has been recent progress to characterize this instability, no global theory is presently available to describe all aspects of the propagation of the segmented front, including both “local” features like the angle of rotation of the facets and the ratio of their width to their spacing, and “global” ones like the effective energy-release-rate of the segmented crack front and the tendency of the facets to coarsen. This paper embarks on the development of such a theory, based on the assumption that the spacing of the facets is much smaller than their length, and asymptotic matching of outer and inner solutions for the mechanical fields on scales comparable to the facet length and spacing, respectively. Here, the inner problem is shown to reduce to a 2D linear elastic fracture mechanics problem in the plane perpendicular to the crack propagation axis. The solution of this problem is used to develop an effective cohesive zone description of the crack front on a scale much larger than the facet spacing. Such a description leads to a system of 1D integral equations for the outer mechanical fields on the cohesive zone, which may be solved numerically. Numerical examples are given that notably illustrate the prediction of the effective energy-release-rate of the segmented crack front in terms of the various geometrical parameters; this energy-release-rate is predicted to be smaller for a segmented front than for the parent planar front, with the conclusion that segmentation acts as a toughening mechanism. Implications upon the phenomenon of facet coarsening are also briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Refined Global Segmentation of X-Ray CT Images for Multi-phase Geomaterials

X-ray computed tomography images of three-phase silica sand and glass bead specimens are analyzed and used to evaluate the segmentation performances of Otsu-, and recursion-based multilevel algorithms. A global image segmentation technique that combines iterative and recursive algorithms, namely a refined statistics-based global segmentation is proposed for segmenting multi-phase granular geomaterials. The performance of the proposed algorithm is tested by segmenting partially saturated silica sand and glass bead specimens. For the tested silica sand specimen, the refined statistics method estimated void ratio and degree of saturation were 0.67 and 39.35%. The estimates for the glass bead specimen yielded 0.64 and 43.49%, respectively. The true void ratio (0.66) and degree of saturation (37.71%) were determined with a user-controlled Image processing software package—Image-Pro. It was found that the proposed method estimated the void ratio and the degree of saturation with 1.52 and 4.35 percent errors for the silica sand and with 15.63 and 0.34 percent errors for the glass bead, respectively. The computational time of the proposed method was found to be shorter than other methods considered. Overall, it is concluded that the proposed technique performed better in segmenting three-phase granular geomaterials.

42 ENGINEERING↗

Optimizing inference of segmentation on high-resolution images in MLExchange

MLExchange is a machine learning (ML) operations platform providing web user-interfaces (UIs) for data visualization and analysis pipelines at synchrotron facilities. Among these UIs is the segmentation app which helps synchrotron users utilize ML algorithms to automatically segment high-resolution scientific images with minimal manual annotation effort. In this work, we share code optimizations that significantly speed up the segmentation inference workflow of large data in short time. By optimizing the sequence of CPU-GPU data transfers and introducing CPU parallelization to key operations, we improve the per-device, per-image frame computational efficiency and observe close to 3×$$\times$$ speedup over the original segmentation inference workflow run time when utilizing a single GPU. Further adaptations enabling multi-GPU inference yield more than 40×$$\times$$ speedup with 100 GPUs compared to the optimized single GPU inference workflow. This acceleration of the segmentation inference workflow will provide MLExchange users with easy access to segmentation results with little wait time.

Lu, Shizhao↗

Automated Grain Boundary (GB) Segmentation and Microstructural Analysis in 347H Stainless Steel Using Deep Learning and Multimodal Microscopy

Austenitic 347H stainless steel offers superior mechanical properties and corrosion resistance required for extreme operating conditions such as high temperature. The change in microstructure due to composition and process variations is expected to impact material properties. Identifying microstructural features such as grain boundaries thus becomes an important task in the process-microstructure-properties loop. Applying convolutional neural network (CNN)-based deep learning models is a powerful technique to detect features from material micrographs in an automated manner. In contrast to microstructural classification, supervised CNN models for segmentation tasks require pixel-wise annotation labels. However, manual labeling of the images for the segmentation task poses a major bottleneck for generating training data and labels in a reliable and reproducible way within a reasonable timeframe. Microstructural characterization especially needs to be expedited for faster material discovery by changing alloy compositions. Here, in this study, we attempt to overcome such limitations by utilizing multimodal microscopy to generate labels directly instead of manual labeling. We combine scanning electron microscopy images of 347H stainless steel as training data and electron backscatter diffraction micrographs as pixel-wise labels for grain boundary detection as a semantic segmentation task. The viability of our method is evaluated by considering a set of deep CNN architectures. We demonstrate that despite producing instrumentation drift during data collection between two modes of microscopy, this method performs comparably to similar segmentation tasks that used manual labeling. Additionally, we find that naïve pixel-wise segmentation results in small gaps and missing boundaries in the predicted grain boundary map. By incorporating topological information during model training, the connectivity of the grain boundary network and segmentation performance is improved. Finally, our approach is validated by accurate computation on downstream tasks of predicting the underlying grain morphology distributions which are the ultimate quantities of interest for microstructural characterization.

36 MATERIALS SCIENCE↗

Nephron segment-specific gene expression using AAV vectors

AAV9 vector provides efficient gene transfer in all segments of the renal nephron, with minimum expression in non-renal cells, when administered retrogradely via the ureter. It is important to restrict the transgene expression to the desired cell type within the kidney, so that the physiological endpoints represent the function of the transgene expressed in that specific cell type within kidney. We hypothesized that segment-specific gene expression within the kidney can be accomplished using the highly efficient AAV9 vectors carrying the promoters of genes that are expressed exclusively in the desired segment of the nephron in combination with administration by retrograde infusion into the kidney via the ureter. We constructed AAV vectors carrying eGFP under the control of: kidney-specific cadherin (KSPC) gene promoter for expression in the entire nephron; Na{sup +}/glucose co-transporter (SGLT2) gene promoter for expression in the S1 and S2 segments of the proximal tubule; sodium, potassium, 2 chloride co-transporter (NKCC2) gene promoter for expression in the thick ascending limb of Henle's loop (TALH); E-cadherin (ECAD) gene promoter for expression in the collecting duct (CD); and cytomegalovirus (CMV) early promoter that provides expression in most of the mammalian cells, as control. We tested the specificity of the promoter constructs in vitro for cell type-specific expression in mouse kidney cells in primary culture, followed by retrograde infusion of the AAV vectors via the ureter in the mouse. Our data show that AAV9 vector, in combination with the segment-specific promoters administered by retrograde infusion via the ureter, provides renal nephron segment-specific gene expression.

60 APPLIED LIFE SCIENCES↗

INVESTIGATION ON THE RESPONSE OF SEGMENTED CONCRETE TARGETS TO PROJECTILE IMPACTS

The study of penetrator performance without free-surface effects can require prohibitively large monolithic targets. One alternative to monolithic targets is to use segmented targets made by stacking multiple concrete slabs in series. This paper presents an experimental investigation on the performance of segmented concrete targets. Six experiments were carried out on available small scale segmented and monolithic targets using instrumented projectiles. In all but one experiment using stacked slabs, the gap between slabs remained open. In the final experiment design, grout was inserted between the slabs, and this modification produced a target response that more closely represents that of the monolithic target. The results from this study suggest that further research on segmented targets is justified, to explore in more detail the response of segmented targets and the results of large scale tests when using segmented targets versus monolithic targets.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Volume of Lytic Vertebral Body Metastatic Disease Quantified Using Computed Tomography–Based Image Segmentation Predicts Fracture Risk After Spine Stereotactic Body Radiation Therapy

Purpose: To determine a threshold of vertebral body (VB) osteolytic or osteoblastic tumor involvement that would predict vertebral compression fracture (VCF) risk after stereotactic body radiation therapy (SBRT), using volumetric image-segmentation software. Methods and Materials: A computational semiautomated skeletal metastasis segmentation process refined in our laboratory was applied to the pretreatment planning CT scan of 100 vertebral segments in 55 patients treated with spine SBRT. Each VB was segmented and the percentage of lytic and/or blastic disease by volume determined. Results: The cumulative incidence of VCF at 3 and 12 months was 14.1% and 17.3%, respectively. The median follow-up was 7.3 months (range, 0.6-67.6 months). In all, 56% of segments were determined lytic, 23% blastic, and 21% mixed, according to clinical radiologic determination. Within these 3 clinical cohorts, the segmentation-determined mean percentages of lytic and blastic tumor were 8.9% and 6.0%, 0.2% and 26.9%, and 3.4% and 15.8% by volume, respectively. On the basis of the entire cohort (n=100), a significant association was observed for the osteolytic percentage measures and the occurrence of VCF (P<.001) but not for the osteoblastic measures. The most significant lytic disease threshold was observed at ≥11.6% (odds ratio 37.4, 95% confidence interval 9.4-148.9). On multivariable analysis, ≥11.6% lytic disease (P<.001), baseline VCF (P<.001), and SBRT with ≥20 Gy per fraction (P=.014) were predictive. Conclusions: Pretreatment lytic VB disease volumetric measures, independent of the blastic component, predict for SBRT-induced VCF. Larger-scale trials evaluating our software are planned to validate the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segmentation precision of abdominal anatomy for MRI-based radiotherapy

The limited soft tissue visualization provided by computed tomography, the standard imaging modality for radiotherapy treatment planning and daily localization, has motivated studies on the use of magnetic resonance imaging (MRI) for better characterization of treatment sites, such as the prostate and head and neck. However, no studies have been conducted on MRI-based segmentation for the abdomen, a site that could greatly benefit from enhanced soft tissue targeting. We investigated the interobserver and intraobserver precision in segmentation of abdominal organs on MR images for treatment planning and localization. Manual segmentation of 8 abdominal organs was performed by 3 independent observers on MR images acquired from 14 healthy subjects. Observers repeated segmentation 4 separate times for each image set. Interobserver and intraobserver contouring precision was assessed by computing 3-dimensional overlap (Dice coefficient [DC]) and distance to agreement (Hausdorff distance [HD]) of segmented organs. The mean and standard deviation of intraobserver and interobserver DC and HD values were DC{sub intraobserver} = 0.89 ± 0.12, HD{sub intraobserver} = 3.6 mm ± 1.5, DC{sub interobserver} = 0.89 ± 0.15, and HD{sub interobserver} = 3.2 mm ± 1.4. Overall, metrics indicated good interobserver/intraobserver precision (mean DC > 0.7, mean HD < 4 mm). Results suggest that MRI offers good segmentation precision for abdominal sites. These findings support the utility of MRI for abdominal planning and localization, as emerging MRI technologies, techniques, and onboard imaging devices are beginning to enable MRI-based radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transient Microstructure of Low Hard Segment Thermoplastic Polyurethane under Uniaxial Deformation

Microstructure evolution of a low hard segment (<10 mol %) thermoplastic polyurethane (LHS-TPU) has been followed by in-situ wide-angle X-ray (WAX) and small-angle X-ray scattering (SAX) with a focus on elucidating peculiar microstructural changes during uniaxial deformation ({gamma} = 1-3.5). For the LHS-TPU, the hard segments, due to their low content and chemical structure, do not crystallize but form glassy regions that act as physical cross-links. Two types of soft segment crystallites are resolved upon elongation via DSC, SAX, and WAX experiments. Phase I consists of a small amount of initial crystallites (<2%) that function similar to conventional PU hard segment domains, deforming at small uniaxial strains ({gamma} = 1-2) to a chevron-type morphology, which exhibit equatorial 4-point patterns in SAX. Phase II evolves at higher deformations ({gamma} > 2) due to strain-induced crystallization. Phase II exhibits a conventional meridional 2-point pattern along the deformation direction with lamellar crystallites aligning in the plane normal to the deformation. WAX, SAX, and DSC confirm that both phases coexist over a small strain window ({gamma} = 1.9-2.5), demonstrating the independent nature of the two crystalline phases. These findings indicate that the LHS-TPU in this study is similar to poly(butylene adipate) (PBA) in its morphological and structural behavior. This is further substantiated by NMR, which reveals that the LHS-TPU consists of 90% soft segments, which are identified as PBA via crystal structure analysis of a highly aligned fiber. The soft segments in the LHS-TPU dominate the morphology and the X-ray patterns upon deformation.

36 MATERIALS SCIENCE↗

Nanochannel-Directed Growth of One-Dimensional Multi-Segment Heterojunctions of Metallic Au1-xGex and Semiconducting Ge

We report on the synthesis of multi-segment nanowire (NW) junctions of Au{sub 1-x}Ge{sub x} and Ge inside the nanochannels of porous anodic aluminum oxide template. The one-dimensional heterostructures are grown with a low-temperature chemical vapor deposition process, assisted by electrodeposited Au nanowires (AuNWs). The Au-catalyzed vapor-liquid-solid growth process occurs simultaneously in multiple locations along the nanochannel, which leads to multi-segment Au{sub 1-x}Ge{sub x}/Ge heterojunctions. The structures of the as-grown hybrid NWs, analyzed by using transmission electron microscopy and energy-dispersive X-ray spectroscopy elemental mapping, show clear compositional modulation with variable modulation period and controllable junction numbers. Remarkably, both GeNW and Au{sub 1-x}Ge{sub x}NW segments are single crystalline with abrupt interfaces and good crystallographic coherences. The electronic and transport properties of individual NW junctions are measured by using a multi-probe scanning tunneling microscope, which confirms the semiconducting nature of Ge segments and the metallic behavior of Au{sub 1-x}Ge{sub x} segments, respectively. The high yield of multiple segment NW junctions of a metal-semiconductor can facilitate the applications in nanoelectronics and optoelectronics that harness multiple functionalities of heterointerfaces.

36 MATERIALS SCIENCE↗

SwinCell: a 3D transformer and flow-based framework for improved cell segmentation

Segmentation of three-dimensional (3D) cellular images is fundamental for studying and understanding cell structure and function. However, 3D cellular segmentation is challenging, particularly for dense cells and tissues. This challenge arises mainly from the complex contextual information within 3D images, anisotropic properties, and the sensitivity to internal cellular structures, which often lead to incorrect segmentation. In this work, we introduce SwinCell, a 3D transformer-based framework that leverages Swin-transformer to predict flow and differentiate individual cell instances. We demonstrate SwinCell’s utility in the segmentation of nuclei, colon tissue cells, and densely cultured cells. SwinCell strikes a balance between maintaining detailed local feature recognition and understanding broader contextual information. Through extensive testing with both public and in-house 3D cell imaging datasets, SwinCell shows utility in segmenting dense cells, making it a valuable tool for 3D segmentation in cellular analysis that could expedite research in cell biology and tissue engineering.

59 BASIC BIOLOGICAL SCIENCES↗

MultiTaskDeltaNet: change detection-based image segmentation for operando ETEM with application to carbon gasification kinetics

Transforming in situ transmission electron microscopy (TEM) imaging into a tool for spatially-resolved operando characterization of solid-state reactions requires automated, high-precision semantic segmentation of dynamically evolving features. However, traditional deep learning methods for semantic segmentation often face limitations due to the scarcity of labeled data, visually ambiguous features of interest, and scenarios involving small objects. To tackle these challenges, we introduce MultiTaskDeltaNet (MTDN), a novel deep learning architecture that creatively reconceptualizes the segmentation task as a change detection problem. By implementing a unique Siamese network with a U-Net backbone and using paired images to capture feature changes, MTDN effectively leverages minimal data to produce high-quality segmentations. Furthermore, MTDN utilizes a multi-task learning strategy to exploit correlations between physical features of interest. In an evaluation using data from in situ environmental TEM (ETEM) videos of filamentous carbon gasification, MTDN demonstrated a significant advantage over conventional segmentation models, particularly in accurately delineating fine structural features. Notably, MTDN achieved a 10.22% performance improvement over conventional segmentation models in predicting small and visually ambiguous physical features. This work bridges key gaps between deep learning and practical TEM image analysis, advancing automated characterization of nanomaterials in complex experimental settings.

08 HYDROGEN↗

Modeling of current characteristics of segmented Langmuir probe on DEMETER

We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numerically with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V{sub clay} (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Number and Pattern of Viral Genomic Reassortments are not Necessarily Identifiable from Segment Trees

Reassortment is an evolutionary process common in viruses with segmented genomes. These viruses can swap whole genomic segments during cellular co-infection, giving rise to novel progeny formed from the mixture of parental segments. Since large-scale genome rearrangements have the potential to generate new phenotypes, reassortment is important to both evolutionary biology and public health research. However, statistical inference of the pattern of reassortment events from phylogenetic data is exceptionally difficult, potentially involving inference of general graphs in which individual segment trees are embedded. In this paper, we argue that, in general, the number and pattern of reassortment events are not identifiable from segment trees alone, even with theoretically ideal data. We call this fact the fundamental problem of reassortment, which we illustrate using the concept of the “first-infection tree,” a potentially counterfactual genealogy that would have been observed in the segment trees had no reassortment occurred. Further, we illustrate four additional problems that can arise logically in the inference of reassortment events and show, using simulated data, that these problems are not rare and can potentially distort our observation of reassortment even in small data sets. Finally, we discuss how existing methods can be augmented or adapted to account for not only the fundamental problem of reassortment, but also the four additional situations that can complicate the inference of reassortment.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of U-net-based Image Segmentation Model to Digital Mammography

Detecting suspicious lesions in medical imaging is the important first step in computer-aided detection (CAD) systems. However, detecting abnormalities in breast tissue is difficult due to the lesion's varying size, shape, margin, and contrast with the background tissue. We focused on mass segmentation, a method that provides notable morphological features by outlining contours of masses. Accurate segmentation is crucial for correct diagnosis. Recent advancements in deep learning have improved object detection and segmentation, and these techniques are also being applied to medical imaging studies. We focused on U-net, which is a recently developed mass segmentation algorithm based on a fully convolutional network. The U-net architecture consists of (1) a contracting path to increase the resolution of the output and (2) a symmetric expanding path to better locate the region of interest. The performance of a U-net model was tested with 63 digital mammograms from INbreast, a publicly available database. We trained the model with images resized to 40x40 pixels and conducted 10-fold cross-validation to prevent overfitting. The model's performance with respect to breast density and the lesion's BI-RADS rating was also investigated. Dice coefficients (DC) were used as a performance measure to compare the predicted segmentation of the model with the ground truth. Logistic regression and an analysis of variance were performed to determine the significance of the DCs with regards to breast density and lesion behavior and to calculate the 95% confidence interval. The average DC was 0.80. The difference between DCs for BI-RADS 2 and 4c and for BI-RADS 2 and 5 were significant, suggesting that the model has more difficulty in segmenting benign lesions.

Cho, Priscilla↗

Proximal femur segmentation in conventional pelvic x ray

A solid and accurate proximal femur segmentation technique using the popular active shape model (ASM) is proposed. For generating an optimal shape prior, the minimum description length, based on 200 supervised manual segmented proximal femur shapes, is used. The segmentation is based on a coarse to fine scaling technique including a profile scale space method. The segmentation results are compared using an optimal defined initial pose and a pose based on a registration technique. Using ideal template initialization, 95% of the shapes have been recovered exactly (average point-to-point error {approx}13 pixels, average point-to-boundary error {approx}7 pixels). Using a template-based initialization based on a registration technique, a successful segmentation rate of {approx}89% is achieved, with an average point-to-point error {approx}12 pixels, and an average point-to-boundary error {approx}8 pixels. With an adequate template initialization and an improved ASM, this method seems to provide an accurate tool for segmentation of the proximal femur shapes on conventional hip overview x-ray images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: An evaluation study

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols, and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using different imaging equipment. Evaluation included qualitative and quantitative analyses of the segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: isointensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an intermodality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE differed from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability of GAR was superior to manual measurements and ISE. The intermodality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

60 APPLIED LIFE SCIENCES↗