Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

CO Chondrite Parent Body Processing as Recorded by Noble Gases

**Introduction:** CO carbonaceous chondrites are among the most primitive meteorites, of which some experienced mild degrees of thermal alteration (up to 500 °C) in their parent asteroid. Previous studies on aqueously altered CM, CY and CR chondrites have shown that the noble gases preserved in those meteorites can be used to assess the extent of parent body processing. This is mostly due to an Ar-rich carrier phase being susceptible to aqueous alteration. In this study, we follow up on these findings by investigating the effects of mild thermal alteration on the noble gas content of CO chondrites. They are subclassified from petrologic subtype 3.0 (e.g., Yamato-81025) to 3.8 (e.g., Isna) according to the degree of thermal alteration experienced. Understanding these effects does not only help to distinguish the most primitive samples from the severely altered ones, but also adds to the picture of the primordial volatile composition and distribution, as preserved in the most primitive material which accreted from the solar nebula at different heliocentric distances. Additionally, we search for pairing among samples, as part of an ongoing survey of Antarctic CO chondrites. **Experimental:** Noble gas measurements were conducted on aliquots of ~20-25 mg from 16 different samples of varying petrologic subtype from 3.0 to 3.8. The gas extraction occurred in one temperature step at ~1700 °C, followed by separation into three fractions, He-Ne, Ar, and Kr-Xe, measured successively in a custom-built mass spectrometer. For each sample, complete gas extraction was verified by a re-extraction step at ~1750 °C. Details on the sample preparation and measurement protocols can be found in. **Results and Discussion:** In most cases, the gas concentrations for all five noble gases decrease with increasing petrologic subtype, and the trend is most pronounced for Ne. An exception is e.g. CO3.0 Colony, which is strongly terrestrially weathered. CO3.8 Isna shows an unusually short expo-sure time to cosmic rays (~0.15 Ma), which may be explained by a direct injection into a mean orbital resonance shortly after collision. The currently ill-defined Ar-rich carrier phase, found only in the least aqueously altered CM and CR samples, is still abundantly present in the predominately anhydrous CO chondrites, indicating that this component is less susceptible to moderately elevated temperatures. No CO chondrites examined so far contain solar wind, supporting the hypothesis that CO chondrites originate from the asteroidal interior. It thus remains enigmatic which material could account for the surface layer.

Noble gas↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Contact Conductivity Measurement for Automated Sample Processing Systems

A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

Beegle, Luther W.↗

Inflight resistance measurement on high-T(sub c) superconducting thin films exposed to orbital atomic oxygen on CONCAP-2 (STS-46)

In 1992, UAH (University of Alabama in Huntsville) conducted a unique experiment on STS-46 in which YBa2Cu3O7 (commonly known as '1-2-3' superconductor) high-T(c) superconducting thin film samples prepared at three different laboratories were exposed to 5 eV atomic oxygen in low Earth orbit on the ambient and 320 C hot plate during the first flight of the CONCAP-2 (Complex Autonomous Payload) experiment carrier. The resistance of the thin films was measured in flight during the atomic oxygen exposure and heating cycle. Superconducting properties were measured in the laboratory before and after the flight by the individual experimenters. Films with good superconducting properties, and which were exposed to the oxygen flux, survived the flight including those heated to 320 C (600 K) with properties essentially unchanged, while other samples which were heated but not exposed to oxygen were degraded. The properties of other flight controls held at ambient temperature appear unchanged and indistinguishable from those of ground controls, whether exposed to oxygen or not.

Gregory, J. C.↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

Wang, Zuwei↗

Biomolecule Sequencer: Next-Generation DNA Sequencing Technology for In-Flight Environmental Monitoring, Research, and Beyond

On the International Space Station (ISS), technologies capable of rapid microbial identification and disease diagnostics are not currently available. NASA still relies upon sample return for comprehensive, molecular-based sample characterization. Next-generation DNA sequencing is a powerful approach for identifying microorganisms in air, water, and surfaces onboard spacecraft. The Biomolecule Sequencer payload, manifested to SpaceX-9 and scheduled on the Increment 4748 research plan (June 2016), will assess the functionality of a commercially-available next-generation DNA sequencer in the microgravity environment of ISS. The MinION device from Oxford Nanopore Technologies (Oxford, UK) measures picoamp changes in electrical current dependent on nucleotide sequences of the DNA strand migrating through nanopores in the system. The hardware is exceptionally small (9.5 x 3.2 x 1.6 cm), lightweight (120 grams), and powered only by a USB connection. For the ISS technology demonstration, the Biomolecule Sequencer will be powered by a Microsoft Surface Pro3. Ground-prepared samples containing lambda bacteriophage, Escherichia coli, and mouse genomic DNA, will be launched and stored frozen on the ISS until experiment initiation. Immediately prior to sequencing, a crew member will collect and thaw frozen DNA samples, connect the sequencer to the Surface Pro3, inject thawed samples into a MinION flow cell, and initiate sequencing. At the completion of the sequencing run, data will be downlinked for ground analysis. Identical, synchronous ground controls will be used for data comparisons to determine sequencer functionality, run-time sequence, current dynamics, and overall accuracy. We will present our latest results from the ISS flight experiment the first time DNA has ever been sequenced in space and discuss the many potential applications of the Biomolecule Sequencer for environmental monitoring, medical diagnostics, higher fidelity and more adaptable Space Biology Human Research Program investigations, and even life detection experiments for astrobiology missions.

Sequencer↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Small Particle Glovebox Experiments - Preliminary Results

A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.

C. J. Snead↗

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

gene expression↗

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

quantitative PCR↗

Coordinated Analyses of Diverse Components in Whole Stardust Cometary Tracks

Analyses of samples returned from Comet 81P/Wild-2 by the Stardust spacecraft have resulted in a number of surprising findings that show the origins of comets are more complex than previously suspected. However, these samples pose new experimental challenges because they are diverse and suffered fragmentation, thermal alteration, and fine scale mixing with aerogel. Questions remain about the nature of Wild-2 materials, such as the abundances of organic matter, crystalline materials, and presolar grains. To overcome these challenges, we have developed new sample preparation and analytical techniques tailored for entire aerogel tracks. We have successfully ultramicrotomed entire "carrot" and "bulbous" type tracks along their axis while preserving their original shapes. This innovation allowed us to examine the distribution of fragments along the track from the entrance hole all the way to the terminal particle (TP). We will present results of our coordinated analysis of the "carrot" type aerogel tracks #112 and #148, and the "bulbous" type aerogel tracks #113, #147 and #168 from the nanometer to the millimeter scale. Scanning TEM (STEM) was used for elemental and detailed mineralogy characterization, NanoSIMS was used for isotopic analyses, and ultrafast two-step laser mass spectrometry (ultra L2MS) was used to investigate the nature and distribution of organic phases. The isotopic measurements were performed following detailed TEM characterization for coordinated mineralogy. This approach also enabled spatially resolving the target sample from fine-scale mixtures of compressed aerogel and melt. Eight of the TPs of track #113 are dominated by coarse-grained enstatite (En90) that is largely orthoenstatite with minor, isolated clinoenstatite lamellae. One TP contains minor forsterite (Fo88) and small inclusions of diopside with % levels of Al, Cr and Fe. Two of the TPs contain angular regions of fine-grained nepheline surrounded by enstatite. Their O isotopic compositions are in the range of meteoritic materials, implying that they originated in the inner Solar System. Complex aromatic hydrocarbons are distributed along aerogel tracks and in TPs. These organics are likely cometary but were affected by shock heating. Three TPs of track #147 and two of track 168 have completely different mineralogy. TP2 of track #147 entirely consists of Fe-Ni alloy (5 at% Ni) and TP3 contains Fa28 with partial olivine-pyroxene intergrowth and minor albite. TP4 contains pentlandite, Fe-olivine, albite and high Ca pyroxene with Na and Cr (kosmochlor component). TP1 of #168 contains Fe-olivine, albite and pentlandite, and the concentric TP2 has a core of olivine grains with co-existing indigenous amorphous SiO2 surrounded by a carbon mantle, which in turn is surrounded by a layer of compressed aerogel. The TP of the carrot track #112 is a (16)O-rich forsteritic olivine grain that likely formed in the inner Solar System. The track also contains submicron-sized diamond grains of likely Solar System origin.

Nakamura-Messenger, Keiko↗

A Mossbauer investigation of iron-rich terrestrial hydrothermal vent systems: lessons for Mars exploration

Hydrothermal spring systems may well have been present on early Mars and could have served as a habitat for primitive life. The integrated instrument suite of the Athena Rover has, as a component on the robotic arm, a Mossbauer spectrometer. In the context of future Mars exploration we present results of Mossbauer analysis of a suite of samples from an iron-rich thermal spring in the Chocolate Pots area of Yellowstone National Park (YNP) and from Obsidian Pool (YNP) and Manitou Springs, Colorado. We have found that Mossbauer spectroscopy can discriminate among the iron-bearing minerals in our samples. Those near the vent and on the surface are identified as ferrihydrite, an amorphous ferric mineraloid. Subsurface samples, collected from cores, which are likely to have undergone inorganic and/or biologically mediated alteration (diagenesis), exhibit spectral signatures that include nontronite (a smectite clay), hematite (alpha-Fe2O3), small-particle/nanophase goethite (alpha-FeOOH), and siderite (FeCO3). We find for iron minerals that Mossbauer spectroscopy is at least as efficient in identification as X-ray diffraction. This observation is important from an exploration standpoint. As a planetary surface instrument, Mossbauer spectroscopy can yield high-quality spectral data without sample preparation (backscatter mode). We have also used field emission scanning electron microscopy (FESEM), in conjunction with energy-dispersive X ray (EDX) fluorescence spectroscopy, to characterize the microbiological component of surface sinters and the relation between the microbiological and the mineralogical framework. Evidence is presented that the minerals found in these deposits can have multi-billion-year residence times and thus may have survived their possible production in a putative early Martian hot spring up to the present day. Examples include the nanophase property and the Mossbauer signature for siderite, which has been identified in a 2.09-billion-year old hematite-rich chert stromatolite. Our research demonstrates that in situ Mossbauer spectroscopy can help determine whether hydrothermal mineral deposits exist on Mars, which is significant for exobiology because of the issue of whether that world ever had conditions conductive to the origin of life. As a useful tool for selection of samples suitable for transport to Earth, Mossbauer spectroscopy will not only serve geological interests but will also have potential for exopaleontology.

NASA Discipline Exobiology↗

Mechanical Properties and Microstructure Investigation of Lead Free Solder

While the electronics industry appears to be focusing on Sn-Ag-Cu as the alloy of choice for lead free electronics assembly, ,the exact composition varies by geographic region, supplier and user. Add to that dissolved copper and silver from the printed circuit board traces and surface finish, and there can be significant variation in the final solder joint composition. A systematic study of the mechanical and microstructural properties of Sn-Ag-Cu alloys with Ag varying from 2wt% to 4wt% and Cu varying from 0.5wt% to lSwt%, was undertaken in this research study. Different sample preparation techniques (water quenched, oil quenched and water quenched followed by reflow) were explored and the resulting microstructure compared to that of a typical reflowed lead free chip scale package (CSP) solder joint. Tensile properties (modulus, 0.2% yield strength and the ultimate tensile strength) and creep behavior of selected alloy compositions (Sn-4Ag-1 X u , Sn-4Ag-OSCu, Sn- 2Ag-1 X u , Sn-2Ag-OSCu, Sn-3.5Ag-O.SCu) were determined for three conditions: as- cast; aged for 100 hours at 125OC; and aged for 250 hours at 125OC. There was no significant difference in Young's Modulus as a function of alloy composition. After an initial decrease in modulus after 100 hours at 125"C, there was an insignificant change with further aging. The distribution of 0.2% strain yield stress and ultimate tensile strength as a function of alloy composition was more significant and decreased with aging time and temperature. The microstructures of these alloys were examined using light and scanning electron microscopy (LM and SEM) respectively and SEM based energy dispersive x-ray spectroscopy (EDS). Fracture surface and cross-section analysis were performed on the specimens after creep testing. The creep testing results and the effect of high temperature aging on mechanical properties is presented for the oil quenched samples. In general the microstructure of oil quenched specimen exhibited a eutectic region of Sn with moderately dispersed Ag3Sn intermetallic, surrounded by a dendritic Sn-rich phase. The SEM images of the fracture surface indicated the presence of a tough shear surface at the initial cavity break area and a break line in the middle of specimen along the failure direction. A hyperbolic-sine creep model was adopted and used to fit the creep experiment data. The effect on the mechanical properties by adding the quaternary element bismuth to the Sn-3.5Ag-0.8Cu alloy was measured and compared with the mechanical properties of the ternary alloys. The results of this research study provide necessary data for the modeling of solder joint reliability for a range of Sn-Ag-Cu compositions and a baseline for evaluating the effects of subsequent quaternary additions.

Wang, Qing↗

Transformative Impacts of Laser-Induced Breakdown Spectroscopy on Environmental and Biological Research at Oak Ridge National Laboratory

This manuscript will present an advancement of transformative research that has been conducted at Oak Ridge National Laboratory (ORNL) over a 25-year period (2000–2025) on a variety of environmental and biological matrices. These investigations derived a fundamental understanding of how elemental detection and analysis of these matrices led to the knowledge and discovery of natural processes in plants and the environment. Each project led to the initiation of a new research area which unearthed awesome and novel breakthroughs. Highlights are listed below: 1. The preliminary research at ORNL centered on the detection of aerosols utilizing Laser-induced Breakdown Spectroscopy (LIBS) technology. The Clean Air Act Amendment (CAAA) of 1990 highlighted the importance of identifying hazardous air pollutants (HAPs) due to their impact on environmental and human health, thereby underscoring the need to detect various toxic elements. Research in aerosol chemistry aimed to identify these harmful elements released by factories during periods of increased emissions in their manufacturing processes. LIBS emerged as the most effective method for real-time, in situ measurements of metal species in both gaseous and aerosol phases. 2. An understanding of the presence of total carbon in soils gives perspective on how to develop carbon sequestration strategies. The recognition that carbon sinks can evolve back to carbon sources to emit back to the atmosphere was an important consideration. Also, the concentration of carbon in soil indicates the health of land areas for growing crops successfully. 3. The direct detection of most of the elements in a wood sample in a single emission spectrum, without sample preparation, encouraged the research to use the LIBS technique for preservative treated wood coupled with use of multivariate statistical methodology. Additionally, it encouraged the researchers to try to differentiate natural woods from different parts of the country, and it was successfully demonstrated that LIBS coupled with MVA analysis could differentiate wood of different species from each other and of similar species grown in different environments based on their elemental spectra. This was a breakthrough since it revealed a systematic approach to connect elemental scarcity and abundance to either drought or typical rainfall conditions for the hardwood trees grown in specific areas. 4. Furthermore, the research progressed to reveal physiological and developmental processes contributing to biomass production such that the variation in leaf elemental composition increases our understanding of terrestrial nutrient cycles, as well as tracking the transfer of toxic elements from soils to living organisms. 5. Recently another breakthrough viz., ionomics initiated the correlation of elements to specific genes, uncovering the function that the element performed in the plant. More recently, this has been extended from plants to fungi as well as fungi growing in symbiotic relations with plants.

09 BIOMASS FUELS↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

The microbiologist's guide to metaproteomics

Metaproteomics is an emerging approach for studying microbiomes, offering the ability to characterize proteins that underpin microbial functionality within diverse ecosystems. As the primary catalytic and structural components of microbiomes, proteins provide unique insights into the active processes and ecological roles of microbial communities. By integrating metaproteomics with other omics disciplines, researchers can gain a comprehensive understanding of microbial ecology, interactions, and functional dynamics. This review, developed by the Metaproteomics Initiative (www.metaproteomics.org), serves as a practical guide for both microbiome and proteomics researchers, presenting key principles, state-of-the-art methodologies, and analytical workflows essential to metaproteomics. Topics covered include experimental design, sample preparation, mass spectrometry techniques, data analysis strategies, and statistical approaches.

bioinformatics↗