Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Surface Water Disinfection Byproducts and Organic Matter Characterization Data Associated with: “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream”

This dataset is associated with the publication “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream” published in Water Research X (Leonard et al. 2022; https://doi.org/10.1016/j.wroa.2022.100144). The associated study analyzed temporal trends from the Town of Crested Butte water treatment facility and synoptic sampling at Coal Creek in Crested Butte, Colorado, US. This work demonstrates how drinking water quality archives combined with synoptic sampling and targeted analyses can be used to identify and understand export control points for dissolved organic matter. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) metadata and international geo-sample number (IGSN) mapping file; (4) dissolved organic carbon (DOC), ultraviolet absorbance at 254 nanometers (UV254), total nitrogen (TN), and specific ultraviolet absorbance (SUVA) data; (5) disinfection bioproduct formation potential (DBP-FP) data; (6) readme; (7) methods codes; (8) water collection protocol; (9) folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory); and (10) folder of excitation emissions matrix (EEM) spectra. The FTICR folder contains a file of DOC (measured as non-purgeable organic carbon; NPOC) used for FTICR sample preparation. The FTICR folder also contains three subfolders: one subfolder containing the raw .xml data files, one containing the processed data, and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .dat, .R, .ref, or .xml

54 ENVIRONMENTAL SCIENCES↗

Low Cost, High Volume, Carbon Fiber Precursor for Plasma Oxidation

Light weighting with carbon fiber is critical to improving the energy efficiency of wind turbines, airplanes, and automobiles, but the high cost of carbon fiber continues to limit market growth and applications. Half of this cost is in the raw materials. For the carbon fiber market to reach the next level of adoption, the cost of both the raw materials and conversion must be reduced. This project considered the combination of low-cost, textile-grade precursors combined with the increased efficiency of plasma oxidation to greatly reduce the cost of carbon fiber. The primary objective of this project was to make industrial-grade carbon fiber (550 ksi tensile strength, 35 Msi tensile modulus) from textile-grade PAN precursors, something that cannot be achieved with conventional oxidation and to date has not been achieved with any technology. To accomplish this, the project team iteratively optimized the process conditions in the plasma oxidation and carbonization stages to maximize the tensile properties of the resultant carbon fibers. This involved implementing experimental designs for both stages, whereby process conditions (e.g. temperature) were varied and correlated to fiber properties. Samples of oxidized PAN fibers (OPFs) were prepared using a small pilot-scale plasma oxidation oven at 4XTechnologies (4XT). The thermal, chemical, and physical properties of OPF samples were analyzed by the University of Tennessee (UTK) and Oak Ridge National Laboratory (ORNL). The OPF samples were then converted to carbon fiber by subsequent low- and high-temperature carbonization using a lab-scale furnace at ORNL. The resultant carbon fibers were tested for tensile strength also at ORNL, and the results were fed back into the experimental design. Of the hundreds of carbon fiber samples produced over the course of the project, the best sample had an average break strength of 479 ksi and modulus of 33 Msi. While the best tensile properties achieved fell short of the final project targets of 550 ksi for break strength and 35 Msi for modulus, the team demonstrated the potential to produce industrial-grade carbon fiber using textile-grade precursors. The best performing fiber samples had tensile properties that are 87% of the goal for tensile strength and 94% of the goal for tensile modulus. With additional optimization work, it is likely that the targets could be achieved, since only a fraction of the process parameter space was explored during this project. 4XT and its affiliate (4M) have already secured funding through private equity, and there is a CRADA (Cooperative Research and Development Agreement) project currently underway with the Carbon Fiber Technology Center (CFTF) at ORNL to continue this research. Additionally, while not an original goal of the project, the carbon fibers for most samples had diameters >8.5μm. This is considerably larger than commercially available carbon fiber products, which can impart unique properties to the composites (e.g. increased compressive strength) and decrease manufacturing costs even further. Moreover, these fibers were oxidized with plasma oxidation using residence times ranging <60mins, which would be considered fast for normal diameter fibers, but it is as much as 5x faster when factoring in the diameter of the fibers.

36 MATERIALS SCIENCE↗

Determining significant material properties: A discovery approach

The following is a laboratory experiment designed to further understanding of materials science. The experiment itself can be informative for persons of any age past elementary school, and even for some in elementary school. The preparation of the plastic samples is readily accomplished by persons with resonable dexterity in the cutting of paper designs. The completion of the statistical Design of Experiments, which uses Yates' Method, requires basic math (addition and subtraction). Interpretive work requires plotting of data and making observations. Knowledge of statistical methods would be helpful. The purpose of this experiment is to acquaint students with the seven classes of recyclable plastics, and provide hands-on learning about the response of these plastics to mechanical tensile loading.

Karplus, Alan K.↗

Coordinated Analysis of an Ion Irradiated Carbonaceous Chondrite Suggests Complex Space Weathering Effects

Surfaces of airless planetary bodies are exposed to micrometeorite bombardment and solar wind irradiation which alter the microstructural, compositional, and optical properties of regoliths over time. These processes are collectively known as space weathering, and they complicate the interpretation of remote sensing data and the subsequent characterization of airless surfaces. Within the next 5 years, NASA’s OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer) and JAXA (Japan Aerospace Exploration Agency)’s Hayabusa2 missions will return samples from C-type asteroids Bennu and Ryugu, respectively. Compared to the Moon and S-type asteroids, our understanding of the space weathering of C-complex asteroids is limited. In order to maximize scientific return from remote sensing data and to prepare for the analysis of returned samples from these missions, we must better understand the effects of space weathering on hydrated, organic-rich materials. We can do so by simulating these processes in the laboratory. In this study, we simulate solar wind exposure through ion irradiation of the CM2 carbonaceous chondrite Murchison - a suitable analog for C-complex asteroids. Here, we present coordinated analyses of a sample before and after ion irradiation.

Laczniak, D. L.↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Defining a national microgravity facility for America's Space Station

Plans for a Microgravity and Materials Processing Facility (with a Manufacturing and Technology Laboratory Module as its main element) on the U.S. Space Station are reviewed and illustrated with drawings, graphs, tables, and diagrams. Consideration is given to the ideal and practically achievable acceleration environment, on-orbit sample preparation and analysis, crew operations, technology-development requirements, and classes of materials with commercial potential (with an emphasis on organic molecular crystals).

Mookherji, Tripty↗

Pyroshock recommendations in proposed MIL-HDBK on 'Dynamic Data Acquisition and Analysis'

The pyroshock recommendations presented in a military handbook on Guidelines for Dynamic Data Acquisition and Analysis, which is being prepared by the Jet Propulsion Laboratory, are summarized. Numerous comments,including suggestions for modifications and additions to the handbook, are discussed. Particular attention is given to recommendations concerning measurement locations, transducers, signal conditioners, data recorders, data sampling, data editing, and data analysis.

Piersol, Allan G.↗

Small Particle Glovebox Experiments - Preliminary Results

A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.

C. J. Snead↗

BioSentinel ISS mission: Analysis of ISS Flight Data and Lessons Learned

As we prepare for a future with a human presence on the Moon, Mars, and beyond, the need for countermeasures to protect astronauts against deep space radiation is ever pressing. However, our understanding of how life operates in the space environment, especially past the protection of the Van Allen radiation belts, is critically limited. BioSentinel, a biological CubeSat, aims to further investigate the effects of deep space ionizing radiation, utilizing the budding yeast Saccharomyces cerevisiae to examine the cell’s DNA damage response. The yeast wild type and a rad51Δ mutant strain defective for DNA damage repair will be monitored via the redox dye alamarBlue and a 3-color LED detection system. Selected as a secondary payload on Artemis I, BioSentinel will be the first deep space biological experiment in a half-century and the first biological CubeSat or free-flyer to ever reach a heliocentric orbit. Notably, BioSentinel is the only biological CubeSat to include an ISS control study in addition to a ground control. Comparisons between the ground, ISS, and free-flyer experiments will allow us to isolate the effects of deep space radiation from those of microgravity. The ISS study also provides a unique platform to conduct important technological and biological testing of BioSentinel’s instrumentation in preparation for the deep space mission. In this work, we use a series of data processing tools and scripts to analyze ISS flight data as well as samples exposed to simulated space radiation at Brookhaven National Laboratory, specifically looking at cell growth, metabolic activity, and duplication rates based on optical absorbance and alamarBlue kinetics. These analyses provide a crucial set of controls and a framework for analyzing and interpreting future data sets from the free-flyer, helping us gain further insight into the health risks astronauts will face when exposed to deep space radiation.

Kylie Lauren Lo-Wen Akiyama↗

Unsupervised Clustering and Supervised Regression Learning to Select High Temperature Oxidation-Resistant Materials

High temperature oxidation and corrosion degradation mechanisms dictate the lifetime of materials critical to energy production. The combination of modeling and experimental approaches such as machine learning (ML) and data analytics, with sufficient experimental data, can accelerate the development of new materials while limiting its cost. In the present work, ML will be applied to two high temperature oxidation data libraries (Oak Ridge National Laboratory and National Air and Space Administration) that comprised of about 5000 mass change sample datasheets for a variety of materials and temperatures in dry air and air + 10 % H2O. A python code was developed to prepare the data for machine learning by collecting and formatting oxidation rate constants, alloy compositions and environment of exposure into a single data frame. Scikit-learn library and Statistics and Machine Learning Toolbox within MathWorks were then used to perform unsupervised clustering and supervised regression learning. The impact of dataset distribution on the performance of the developed ML models was evaluated. Potential strategies to improve the predictions and enhance extrapolative capability of the previously trained model were investigated.

Romedenne, Marie [ORNL] (ORCID:0000000317936561)↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

Antoine, A. C.↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grain orientation in lunar soil

Orientation of lunar soil particles in a vertical plane, as seen in the radiographs of core tubes was characterized by preparing orientation diagrams for the different stratigraphic units. Radiographs of double-core drive tubes 64001/64002, 60009/60010, and 60013/60014 were used. The orientation results reinforced the stratigraphic differences. Another source of fabric data was the laboratory-deposited sample 14163,148. The artificial deposition results showed that the grain arrangements were dependent upon the method of deposition. These results from lunar soil and other data from a crushed basalt simulant can be a basis for the inference that lunar soil grain orientation and properties are useful in interpreting lunar surface history.

Mahmood, A.↗

Optical Properties of Iron Silicates in the Infrared to Millimeter as a Function of Wavelength and Temperature

The Optical Properties of Astronomical Silicates with Infrared Techniques (OPASI-T) program utilizes multiple instruments to provide spectral data over a wide range of temperature and wavelengths. Experimental methods include Vector Network Analyzer (VNA) and Fourier Transform Spectroscopy (FTS) transmission, and reflection/scattering measurements. From this data, we can determine the optical parameters for the index of refraction, n, and the absorption coefficient, k. The analysis of the laboratory transmittance data for each sample type is based upon different mathematical models, which are applied to each data set according to their degree of coherence. Presented here are results from iron silicate dust grain analogs, in several sample preparations and at temperatures ranging from 5-300 K, across the infrared and millimeter portion of the spectrum (from 2.5-10,000 μm or 4,000-1 cm(exp −1).

Optical↗

Importance of Sample Handling and Preparation for Surface Analysis: A Summary of ISO Standard 20579 Part 1, Documenting and Reporting the Handling of Specimens Prior to Analysis

Reliable and reproducible analysis of surfaces is critically dependent on how samples have been collected, handled, and prepared before analysis. Although there are important, well-established general guidelines to minimize unintended alteration of the surfaces to be analyzed, specific handling steps depend on the nature of the samples and information desired. Assessments of the validity and reliability of the results require adequate information about sampling, handling, and processing. ISO standard 20579 part 1 describes the information to be recorded and reported for samples that are prepared or submitted for surface analysis. This paper summarizes elements of the standard, which includes annexes that justify and inform the sample handling processes. Also included is a checklist of information that needs to be recorded and reported and an appendix containing an example of a form that might be used to report the information.

AES↗

Vitrification of Hanford Tank 241-AP-105 Waste at 7 M Na and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection. Hanford tank 241-AP-105 (referred to herein as AP-105) is one of the initial Hanford radioactive tank wastes planned to be processed and vitrified. A portion of AP-105 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL). The waste went through dilution by Columbia River water to reach a target sodium (Na) concentration of 7 M, solids filtration, and cesium removal by ion exchange. A glass composition was calculated from the Kim et al. glass models to satisfy the WTP baseline requirements based on the as-received sample and the target dilution to 7 M, from which a simulant was calculated and glass forming chemical (GFC) additions were determined to form a liquid/solids mixture called melter feed. To prepare for the processing of the 7 M Na AP-105 waste melter feed and learn about the production expectations, the melter feed simulant of 7 M Na AP-105 waste was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization

In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.

Seebeck effect↗