Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Combining RNA-SEQ Datasets from NASA GENELAB: An Evaluation of Correction Methods

Background: Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets. Methods: In the present study, NASA GeneLab-hosted RNAseq datasets from mouse liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, the median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC to determine statistical differences between datasets before and after correction, Principal Component Analysis to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. Results: The results showed that the reference-based approach introduced several additional (and likely artificial) differentially expressed genes when compared with the respective standard approach. Conclusions: Of the methods tested, standard ComBat_seq and DESeq2 were identified as the most robust correction methods for combining spaceflight mouse liver RNAseq datasets hosted on GeneLab.

Finsam Samson↗

Evaluation of Correction Methods for NASA GeneLab Transcriptomic Datasets

Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets such as sex or age of the model organism used. In the present study, NASA GeneLab-hosted RNAseq datasets from rodent liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC, to determine statistical differences between datasets before and after correction, Principal Component Analysis, to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. The results showed that the reference-based approach introduced several additional (and likely artificial) DEGs when compared with the standard approach. Thus, the most robust standard correction will be implemented in the GeneLab Visualization 2.0 platform when datasets are combined.

GeneLab, RNA-seq, Batch Correction↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in Small Particle Handling of Astromaterials in Preparation for OSIRIS-REx and Hayabusa2: Initial Developments

The Astromaterials Acquisition and Curation office at NASA Johnson Space Center has established an Advanced Curation program that is tasked with developing procedures, technologies, and data sets necessary for the curation of future astromaterials collections as envisioned by NASA exploration goals. One particular objective of the Advanced Curation program is the development of new methods for the collection, storage, handling and characterization of small (less than 100 micrometer) particles. Astromaterials Curation currently maintains four small particle collections: Cosmic Dust that has been collected in Earth's stratosphere by ER2 and WB-57 aircraft, Comet 81P/Wild 2 dust returned by NASA's Stardust spacecraft, interstellar dust that was returned by Stardust, and asteroid Itokawa particles that were returned by the JAXA's Hayabusa spacecraft. NASA Curation is currently preparing for the anticipated return of two new astromaterials collections - asteroid Ryugu regolith to be collected by Hayabusa2 spacecraft in 2021 (samples will be provided by JAXA as part of an international agreement), and asteroid Bennu regolith to be collected by the OSIRIS-REx spacecraft and returned in 2023. A substantial portion of these returned samples are expected to consist of small particle components, and mission requirements necessitate the development of new processing tools and methods in order to maximize the scientific yield from these valuable acquisitions. Here we describe initial progress towards the development of applicable sample handling methods for the successful curation of future small particle collections.

Snead, C. J.↗

NASA Tech Briefs, Februrary 2013

Topics covered include: Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space; Gaseous Nitrogen Orifice Mass Flow Calculator; Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards; Rover Low Gain Antenna Qualification for Deep Space Thermal Environments; Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip; Measuring and Estimating Normalized Contrast in Infrared Flash Thermography; Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source; High-Reliability Waveguide Vacuum/Pressure Window; Methods of Fabricating Scintillators With Radioisotopes for Beta Battery Applications; Magnetic Shield for Adiabatic Demagnetization Refrigerators (ADR); CMOS-Compatible SOI MESFETS for Radiation-Hardened DC-to-DC Converters; Silicon Heat Pipe Array; Adaptive Phase Delay Generator; High-Temperature, Lightweight, Self-Healing Ceramic Composites for Aircraft Engine Applications; Treatment to Control Adhesion of Silicone-Based Elastomers; High-Temperature Adhesives for Thermally Stable Aero-Assist Technologies; Rockballer Sample Acquisition Tool; Rock Gripper for Sampling, Mobility, Anchoring, and Manipulation; Advanced Magnetic Materials Methods and Numerical Models for Fluidization in Microgravity and Hypogravity; Data Transfer for Multiple Sensor Networks Over a Broad Temperature Range; Using Combustion Synthesis to Reinforce Berms and Other Regolith Structures; Visible-Infrared Hyperspectral Image Projector; Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor Change_Detection.m; AGATE: Adversarial Game Analysis for Tactical Evaluation; Ionospheric Simulation System for Satellite Observations and Global Assimilative; Modeling Experiments (ISOGAME); An Extensible, User- Modifiable Framework for Planning Activities; Mission Operations Center (MOC) - Precipitation Processing System (PPS) Interface Software System (MPISS); Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter; Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays; RUSHMAPS: Real-Time Uploadable Spherical Harmonic Moment Analysis for Particle Spectrometers; Powered Descent Guidance with General Thrust-Pointing Constraints; X-Ray Detection and Processing Models for Spacecraft Navigation and Timing; and Extreme Ionizing-Radiation-Resistant Bacterium

Source record↗

Interlaboratory Comparisons of NbTi Critical Current Measurements

We report on a multi-institute comparison of critical current data measured on a modern NbTi wire for the Large Hadron Collider (LHC), which has shown a standard deviation below 1% in critical current density spread in more than 1500 measurements. Interlaboratory comparisons on Nb{sub 3}Sn wires have shown ambiguities that could be attributable to strain related differences in critical current density, originating from differences in sample handling, reaction, and mounting techniques, or also to differences in the magnetic field and current calibrations between the institutes. A round robin test of a well characterized NbTi wire provides a baseline variance in critical current results that is presumed to be attributable only to differences in the characterization systems. Systematic differences on the order of 3.5% are found in the comparison. The most likely cause for the observed differences is a small diameter holder that brings the wire into a strain regime in which strain effects can no longer be ignored. A NbTi round robin test, when performed properly, will separate system differences from sample specific differences and provide laboratories with an opportunity to calibrate equipment against a standard measurement.

43 PARTICLE ACCELERATORS↗

Sample Processor for Life on Icy Worlds (SPLIce): Monolithic Manifold-Based System to Recover, Prepare, and Deliver Samples and Standards to Instrumentation Suites for Ocean World Life-Search Missions

A claim of life detection on one of the solar system’s icy ocean worlds would necessitate extraordinarily convincing evidence. Limited energy availability in the oceans of such bodies as Europa and Enceladus argues for microbes as most probable among possible life forms, but evidence of their existence in the surface layers of an icy moon or in a frozen plume ejected into space could take various forms, pointing to instrumentation suites as a preferred means to detect diverse molecular and morphological life indicators. Multiple disparate categories of positive detections could provide truly convincing evidence from samples that may be only a few micro-liters. SPLIce’s Foundation. Teams led by NASA’s Ames Research Center have developed and operated numerous small, live-biology and astrobiology science payloads in space over two decades. Since 2016, we have adapted and augmented their biological sample-handling systems to create compact, robust search-for-life fluidic processors designed to function after a decade or more in transit, in environments with very little gravity and lots of radiation: up to 100’s of kilorads.

Instrumentation suite↗

Automation and AI in Space Drilling

Future planetary surface sampling missions, such as delving past the near-surface ice layers on Mars in search of organics and possibly signs of past/extant life, will require lightweight, low-mass planetary drilling and sample handling. Unlike terrestrial drills, these exploration drills must work dry (without drilling muds or gas), blind (no prior local or regional seismic or other surveys), and light (very low downward force or weight on bit, and perhaps 100 W available from solar power or batteries). Given the lightspeed transmission delays to Mars and outward, an exploratory planetary drill cannot be controlled directly from Earth. Drills that penetrate deeper than a few centimeters are likely to get stuck if operated open-loop (the MSL drill only penetrates 5 cm, and the MER Rock Abrasion Tools 5 mm by comparison), so some form of local drill control is required. In the relatively near-term, human crews cannot be presumed to be available for surface instrument teleoperation. Therefore highly automated drill and sample-transfer operations will be required, to explore the subsurface with the ability to safe robotic drilling systems and recover and continue on from the most probable fault conditions. Current automation, scheduling and diagnostic approaches will be discussed that roughly track the actions and roles of humans in terrestrial manual drilling operations.

drill automation↗

Fungal Exposure to Meteorite Thin Sections: Developing an Experimental to Observe Biogeochemical Changes

The Astromaterials Acquisition & Curation Office maintains collections of meteorite samples collected as part of the Antarctic Search for Meteorites (ANSMET) program. The chief goal of the curation department is to maintain these meteorites in pristine condition. The Astromaterials Research and Exploration Science (ARES) Directorate has implemented a microbial monitoring program for the meteorite collections that has resulted in the isolation of >100 fungal isolates [1], however it is currently unknown if these isolates could present danger to the collections through bioweathering or secretion of organic compounds. We grew a strain of Fusarium oxysporium isolated from nitrogen gas filters feeding the Meteorite Lab nitrogen gas in the presence of a H5 meteorite thin section to determine if this fungus has the capability of altering the mineral structure of this common meteorite. This first trial was to determine and understand the effects of Fusarium oxysporum growth on the iron content within H5 chondrites and evaluate what additional components are needed in the development of future trial runs. This experiment determined new considerations for handling samples, the nature of microscopic scans before and after the incubation period, and the quality of the samples utilized for the experiment. The results of this experiment were promising and warrant further investigation with a more refined process and timeline.

Barbre, K. S. R.↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

Pre-conceptual design activities for the materials plasma exposure experiment

The development of next step fusion facilities such as DEMO or a Fusion Nuclear Science Facility (FNSF) requires first closing technology gaps in a few critical areas. Understanding the material-plasma interface is necessary to enable the development of divertors for long-pulse plasma facilities. A pre-conceptual design for a proposed steady-state linear plasma device, the Materials Plasma Exposure Experiment (MPEX), is underway. A helicon plasma source along with ion cyclotron and electron Bernstein wave heating systems will produce ITER divertor relevant plasma conditions with steady-state parallel heat fluxes of up to 40 MW/m 2 with ion fluxes up to 10 24 /m 2 s on target. Current plans are for the device to use superconducting magnets to produce 1–2 T fields. As a steady-state device, active cooling will be required for components that interact with the plasma (targets, limiters, etc.), as well as for other plasma facing components (transport regions, vacuum tanks, diagnostic ports). Design concepts for the vacuum system, the cooling system, and the plasma heating systems have been completed. The device will include the capability for handling samples that have been neutron irradiated in order to consider the multivariate effects of neutrons, plasma, and high heat-flux on the microstructure of divertor candidate materials. A vacuum cask, which can be disconnected from the high field environment in order to perform in-vacuo diagnosis of the surface evolution is also planned for the facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searching for crystallographic superstructures in kappa-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br.

To resolve a superstructure formation previously reported for the organic superconductor {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br, we present synchrotron x-ray diffraction experiments carried out at the MAGS beamline at BESSY, Helmholtz-Centre Berlin. Surprisingly, in our low temperature (28 K) experiments, when searching k-space at (h 0 3.5), h = 7, 8 and (h 0 0.5), h = 5, 7, for none of these spots we could detect scattering intensity associated to a superstructure formation, in contradiction to previous reports. Our data suggest that details of the structural properties of {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br - such as superstructure formation - sensitively depend on sample handling, e.g., cooling rates (in our case 4 K/min), or thermal cycling. A direct relationship between superstructure formation and terminal ethylene group ordering cannot be verified, disproving proposals put forth previously.

43 PARTICLE ACCELERATORS↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative 14 N NMR with Monte Carlo Uncertainty Analysis of Nitrate/Nitrite in Alkaline Nuclear Waste

While monitoring of nitrate and nitrite concentrations is important for managing corrosion in nuclear waste systems, existing analytical methods are hindered by turbidity, spectral interference, and delays from sample handling. Here, we demonstrate quantitative 14 N nuclear magnetic resonance (qNMR) spectroscopy as a direct, matrix-tolerant approach for nitrate and nitrite detection at natural abundance. Monte Carlo resampling was integrated into the workflow to quantify random error, establish precision–time tradeoffs, and separate noise-limited uncertainty from systematic bias arising from shimming, transmitter offset, or excitation pulse conditions. Quantification of nitrate and nitrite were validated in controlled alkaline matrix challenges and in 18-component Hanford-type simulants. These results establish 14 N qNMR as a practical, uncertainty-bounded tool for monitoring redox-active nitrogen species in chemically complex environments and provide a generalizable framework for quantitative analysis of quadrupolar nuclei.

Graham, Trent R. [Pacific Northwest National Labor↗

Directly Probing the Fracture Behavior of Ultrathin Polymeric Films

Understanding fracture mechanics of ultrathin polymeric films is crucial for modern technologies, including semiconductor and coating industries. However, up to now, the fracture behavior of sub-100 nm polymeric thin films is rarely explored due to challenges in handling samples and limited testing methods available. In this work, we report a new testing methodology that can not only visualize the evolution of the local stress distribution through wrinkling patterns and crack propagation during the deformation of ultrathin films but also directly measure their fracture energies. Using ultrathin polystyrene films as a model system, we both experimentally and computationally investigate the effect of the film thickness and molecular weight on their fracture behavior, both of which show a ductile-to-brittle transition. Furthermore, we demonstrate the broad applicability of this testing method in semicrystalline semiconducting polymers. We anticipate our methodology described here could provide new ways of studying the fracture behavior of ultrathin films under confinement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗