Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Free energy landscape and molecular pathways of gas hydrate nucleation

Despite the significance of gas hydrates in diverse areas, a quantitative knowledge of hydrate formation at a molecular level is missing. The impediment to acquiring this understanding is primarily attributed to the stochastic nature and ultra-fine scales of nucleation events, posing a great challenge for both experiment and simulation to explore hydrate nucleation. Here we employ advanced molecular simulation methods, including forward flux sampling (FFS), p{sub B} histogram analysis, and backward flux sampling, to overcome the limit of direct molecular simulation for exploring both the free energy landscape and molecular pathways of hydrate nucleation. First we test the half-cage order parameter (H-COP) which we developed for driving FFS, through conducting the p{sub B} histogram analysis. Our results indeed show that H-COP describes well the reaction coordinates of hydrate nucleation. Through the verified order parameter, we then directly compute the free energy landscape for hydrate nucleation by combining both forward and backward flux sampling. The calculated stationary distribution density, which is obtained independently of nucleation theory, is found to fit well against the classical nucleation theory (CNT). Subsequent analysis of the obtained large ensemble of hydrate nucleation trajectories show that although on average, hydrate formation is facilitated by a two-step like mechanism involving a gradual transition from an amorphous to a crystalline structure, there also exist nucleation pathways where hydrate crystallizes directly, without going through the amorphous stage. The CNT-like free energy profile and the structural diversity suggest the existence of multiple active transition pathways for hydrate nucleation, and possibly also imply the near degeneracy in their free energy profiles among different pathways. Our results thus bring a new perspective to the long standing question of how hydrates crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A numerical study of shock waves generated through laser ablation of explosives

Shock waves resulting from irradiation of energetic materials with a pulsed ultraviolet laser source have been shown to be an effective indicator for explosives detection. In this study, the features of shock wave propagation are explored theoretically. The initial stage of the shock motion is simulated as a one-dimensional process. As the nonlinear wave expands to form a blast wave, a system of conservation equations, simplified to the Euler equations, is employed to model wave propagation. The Euler equations are solved numerically by the 5th order weighted essentially non-oscillatory finite difference scheme with the time integration carried out using the 3rd order total variation diminishing Runge Kutta method. The numerical results for the shock wave evolution are compared with those obtained from experiments with a meltcast 2,6-dinitrotoluene sample. The calculations lay a theoretical foundation for a recently investigated technique for photoacoustically sensing explosives using a vibrometer.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TeraChem protocol buffers ( TCPB ): Accelerating QM and QM/MM simulations with a client–server model

The routine use of electronic structures in many chemical simulation applications calls for efficient and easy ways to access electronic structure programs. Here, we describe how the graphics processing unit (GPU) accelerated electronic structure program TeraChem can be set up as an electronic structure server, to be easily accessed by third-party client programs. We exploit Google’s protocol buffer framework for data serialization and communication. The client interface, called TeraChem protocol buffers (TCPB), has been designed for ease of use and compatibility with multiple programming languages, such as C++, Fortran, and Python. To demonstrate the ease of coupling third-party programs with electronic structures using TCPB, we have incorporated the TCPB client into Amber for quantum mechanics/molecular mechanics (QM/MM) simulations. The TCPB interface saves time with GPU initialization and I/O operations, achieving a speedup of more than 2× compared to a prior file-based implementation for a QM region with ~250 basis functions. We demonstrate the practical application of TCPB by computing the free energy profile of p-hydroxybenzylidene-2,3-dimethylimidazolinone (p-HBDI - )—a model chromophore in green fluorescent proteins—on the first excited singlet state using Hamiltonian replica exchange for enhanced sampling. All calculations in this work have been performed with the non-commercial freely-available version of TeraChem, which is sufficient for many QM region sizes in common use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of structural, transport and magneto-crystalline anisotropy in La 1-x Sr x MnO 3 (0.30 ≤ x ≤ 0.40) perovskite manganites

In this paper we present structural, transport, magnetic and magneto-crystalline anisotropy of La 1–x Sr x MnO 3 (х = 0.30, 0.33, 0.36, and 0.40) synthesized using the solid-state reaction method. The X-ray diffraction pattern of the samples is well indexed to the rhombohedral structure with R 3 - c space group. Lattice parameters and unit cell volume are found to decrease monotonically upon increasing Sr 2+ concentration at La 3+ site. X-ray photoelectron spectroscopy confirms the presence of Mn 4+ and Mn 3+ , the ratio of which (Mn 4+ /Mn 3+ ) increases from 0.44 to 0.64 with increasing Sr 2+ concentration. From the ρ(T) and M(T) data analysis, we find that T MI and M S are larger for x = 0.33 composition, suggesting a weakening of the double-exchange interaction due to competing super-exchange interactions in x = 0.30, 0.36 and 0.40 samples. We calculated MCA constant (K 1 ) by fitting the saturation magnetisation data at a higher magnetic field using the law of approach model, M = M S [1-a/H-b/H 2 ]-χH with K 1 2 = (105/8)bMs 2 and is in the order of 10 5 erg/cm 3 .

36 MATERIALS SCIENCE↗

EXPLORING THE CORRELATIONS BETWEEN GLOBULAR CLUSTER POPULATIONS AND SUPERMASSIVE BLACK HOLES IN GIANT GALAXIES

This paper presents an analysis of the correlation between the number of globular clusters (N{sub GC}) in giant galaxies and the mass of the galaxies' central supermassive black hole (M{sub SMBH}). I construct a sample of 20 elliptical, spiral, and S0 galaxies with known SMBH masses and with accurately measured GC system properties derived from wide-field imaging studies. The coefficients of the best-fitting N{sub GC}-M{sub SMBH} relation for the early-type galaxies are consistent with those from previous work but in some cases have smaller relative errors. I examine the correlation between N{sub GC} and M{sub SMBH} for various subsamples and find that elliptical galaxies show the strongest correlation, while S0 and pseudobulge galaxies exhibit increased scatter. I also compare the quality of the fit of the numbers of metal-poor GCs versus SMBH mass and the corresponding fit for metal-rich GCs. I supplement the 20 galaxy sample with 10 additional galaxies with reliable N{sub GC} determinations but without measured M{sub SMBH}. I use this larger sample to investigate correlations between N{sub GC} and host galaxy properties like total galaxy luminosity and stellar mass, and bulge luminosity and mass. I find that the tightest correlation is between N{sub GC} and total galaxy stellar mass. This lends support to the notion that N{sub GC} and M{sub SMBH} are not directly linked but are correlated because both quantities depend on the host galaxy potential. Finally, I use the N{sub GC}-M{sub SMBH} relation derived from the 20 galaxy sample to calculate predicted M{sub SMBH} values for the 10 galaxies with accurate N{sub GC} measurements but without measured SMBH masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective pair potential for random fcc CoCrFeMnNi alloys

The single-phase equiatomic CoCrFeMnNi alloy is a random solid solution of five elements on the face-centered cubic lattice, whose pure constituents crystallize in very different structures and exhibit diverse magnetic properties. Due to the randomness of the alloy, 80% of nearest neighbor bonds are between unlike elements and thus the details of bonding in pure structures are less important. The elastic moduli of this alloy give rise to small Cauchy pressure C 12 - C 44 , which suggests that the dominant part of bonding may be described by a simple pair potential. We test this hypothesis by developing a long-range Lennard-Jones potential in which the equilibrium crystal structures of pure constituents are taken as reference. The standard mixing rules for regular solutions are then adopted to obtain parameters for bonds between unlike elements in the quinary system. The transferability of this potential to quaternary CoCrFeNi, ternary CoCrNi, and binary FeNi alloys is investigated and the predictions compared with experiments and density functional theory calculations. By sampling over a large number of random configurations, we investigate the effect of compositional randomness on misfit volumes, energies of point defects and stacking faults, and the dislocation friction stresses experienced by moving edge and screw dislocations.

Materials Science↗

The SNS/HFIR Web Portal System for SANS

In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 7TB of experiment and user data, approximately 1,000,000 files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

data↗

The SNS/HFIR Web Portal System – How Can it Help Me?

Abstract. In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 5TB of experiment and user data, approximately 660K files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Energy Survey Year 3 results: galaxy sample for BAO measurement

Here, we present and validate the galaxy sample used for the analysis of the baryon acoustic oscillation (BAO) signal in the Dark Energy Survey (DES) Y3 data. The definition is based on a colour and redshift-dependent magnitude cut optimized to select galaxies at redshifts higher than 0.5, while ensuring a high-quality determination. The sample covers ~ 4100 square degrees to a depth of i = 22.3 (AB) at 10σ. It contains 7,031,993 galaxies in the redshift range from z = 0.6 to 1.1, with a mean effective redshift of 0.835. Redshifts are estimated with the machine learning algorithm DNF, and are validated using the VIPERS PDR2 sample. We find a mean redshift bias of z bias ~ 0.01 and a mean uncertainty, in units of 1 + z, of σ 68 ~ 0.03$. We evaluate the galaxy population of the sample, showing it is mostly built upon Elliptical to Sbc types. Furthermore, we find a low level of stellar contamination of ≲ 4 %. We present the method used to mitigate the effect of spurious clustering coming from observing conditions and other large-scale systematics. We apply it to the BAO sample and calculate weights that are used to get a robust estimate of the galaxy clustering signal. This paper is one of a series dedicated to the analysis of the BAO signal in DES Y3. In the companion papers, we present the galaxy mock catalogues used to calibrate the analysis and the angular diameter distance constraints obtained through the fitting to the BAO scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Raman scattering study of spin-density-wave-induced anisotropic electronic properties in A Fe 2 As 2 ( A = Ca , Eu)

We present a polarization-resolved and temperature-dependent Raman scattering study of AFe 2 As 2 (A = Ca, Eu). In the spin-density-wave phase, spectral weight redistribution is observed in the fully symmetric and nonsymmetric scattering channels at different energies. An anisotropic Raman response is observed in the fully symmetric channel in spontaneously detwinned CaFe 2 As 2 samples. We calculate the orbital-resolved electronic structures using a combination of density functional theory and dynamical mean field theory. We identify the electronic transitions corresponding to these two spectral features and find that the anisotropic Raman response originates from the lifted degeneracy of the d xz/yz orbitals in the broken-symmetry phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-dependent Ginzburg-Landau treatment of rf magnetic vortices in superconductors: Vortex semiloops in a spatially nonuniform magnetic field

We apply time-dependent Ginzburg-Landau (TDGL) numerical simulations to study the finite frequency electrodynamics of superconductors subjected to an intense rf magnetic field. Much recent TDGL work has focused on spatially uniform external magnetic fields and largely ignores the Meissner state screening response of the superconductor. In this paper, we solve the TGDL equations for a spatially nonuniform magnetic field created by a point magnetic dipole in the vicinity of a semi-infinite superconductor. A two-domain simulation is performed to accurately capture the effect of the inhomogeneous applied fields and the resulting screening currents. The creation and dynamics of vortex semiloops penetrating deep into the superconductor domain are observed and studied, and the resulting third-harmonic nonlinear response of the sample is calculated. Further, the effect of pointlike defects on vortex semi-loop behavior is also studied. This simulation method will assist our understanding of the limits of superconducting response to intense rf magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalous in-plane electronic scattering in charge ordered Na0.41CoO20.6H2O

We report electronic transport measurements on high quality floating zone grown Na{sub x}CoO{sub 2} and Na{sub 0.41}CoO{sub 2} {center_dot} 0.6H{sub 2}O single crystals. We find an in-plane electronic scattering minimum near 11 K and a clear charge ordering at approximately 50 K. The electronic and magnetic properties in hydrated and nonhydrated Na{sub 0.41}CoO{sub 2} samples are similar at higher temperature, but evolve in markedly different ways below {approx}50 K, where a strong ferromagnetic tendency is observed in the hydrated sample. Model calculations show the relationship of this tendency to the structure of the Fermi surface. The results, particularly the clear differences between the hydrated and nonhydrated material show a substantially enhanced ferromagnetic tendency upon hydration. Implications for superconductivity are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Percent-Level Test of Isotropic Expansion Using Type Ia Supernovae

We propose and implement a novel, robust, and nonparametric test of statistical isotropy of the expansion of the Universe and apply it to around 1000 type Ia supernovae from the Pantheon sample. We calculate the angular clustering of supernova magnitude residuals and compare it to the noise expected under the isotropic assumption. We also test for systematic effects and demonstrate that their effects are negligible or are already accounted for in our procedure. Here, we express our constraints as an upper limit on the rms spatial variation in the Hubble parameter at late times. For the sky smoothed with a Gaussian with FWHM = 60°, less than 1% rms spatial variation in the Hubble parameter is allowed at 99.7% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

A Raman cell based on hollow core photonic crystal fiber for human breath analysis

Purpose: Breath analysis has a potential prospect to benefit the medical field based on its perceived advantages to become a point-of-care, easy to use, and cost-effective technology. Early studies done by mass spectrometry show that volatile organic compounds from human breath can represent certain disease states of our bodies, such as lung cancer, and revealed the potential of breath analysis. But mass spectrometry is costly and has slow-turnaround time. The authors’ goal is to develop a more portable and cost effective device based on Raman spectroscopy and hollow core-photonic crystal fiber (HC-PCF) for breath analysis. Methods: Raman scattering is a photon-molecular interaction based on the kinetic modes of an analyte which offers unique fingerprint type signals that allow molecular identification. HC-PCF is a novel light guide which allows light to be confined in a hollow core and it can be filled with a gaseous sample. Raman signals generated by the gaseous sample (i.e., human breath) can be guided and collected effectively for spectral analysis. Results: A Raman-cell based on HC-PCF in the near infrared wavelength range was developed and tested in a single pass forward-scattering mode for different gaseous samples. Raman spectra were obtained successfully from reference gases (hydrogen, oxygen, carbon dioxide gases), ambient air, and a human breath sample. The calculated minimum detectable concentration of this system was ∼15 parts per million by volume, determined by measuring the carbon dioxide concentration in ambient air via the characteristic Raman peaks at 1286 and 1388 cm{sup −1}. Conclusions: The results of this study were compared to a previous study using HC-PCF to trap industrial gases and backward-scatter 514.5 nm light from them. The authors found that the method presented in this paper has an advantage to enhance the signal-to-noise ratio (SNR). This SNR advantage, coupled with the better transmission of HC-PCF in the near-IR than in the visible wavelengths led to an estimated seven times improvement in the detection sensitivity. The authors’ prototype device also demonstrated a 100-fold improvement over a recently reported detection limit of a reflective capillary fiber-based Raman cell for breath analysis. Continued development is underway to increase the detection sensitivity further to reach practical clinical applications.

60 APPLIED LIFE SCIENCES↗

Non-isothermal crystallization kinetics of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass containing nucleation agent P{sub 2}O{sub 5}/TiO{sub 2}

Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass ceramics containing nucleation agent P{sub 2}O{sub 5}/TiO{sub 2} were prepared by sol-gel method. The samples were characterized by X-ray diffraction (XRD) and differential scanning calorimetry (DSC). The activation energy and kinetic parameters for crystallization of the samples were calculated by the Johnson-Mehi-Avrami (JMA) model and Augis-Bennett method according to the results of DSC. The results showed that the crystallization mechanism of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass, whose non-isothermal kinetic parameter n = 2.3, was consistent with surface crystallization of the JMA model. The kinetics model function of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass, f(α) = 2.3(1–α)[–ln(1–α)]{sup 0.57}, was also obtained. The addition of nucleation agent P{sub 2}O{sub 5}/TiO{sub 2} could reduce the activation energy, which made the crystal growth modes change from onedimensional to three-dimensional.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrophysical properties of solid solutions of silver in PbTe

The thermopower coefficient {alpha}{sub 0} and the electrical conductivity {sigma} of Pb{sub 1-x}Ag{sub x}Te solid solutions, where x = (0-0.007), are measured at T = 300 K. The hole concentration p is calculated. All samples are of the p type. With increasing silver content, {alpha}{sub 0} decreases, while p and {sigma} increase. For undoped crystals, {alpha}{sub 0} = 251.0 {mu}V/K, p = 1.1 Multiplication-Sign 10{sup 18} cm{sup -3}, and {sigma} = 165 {Omega}{sup -1} cm{sup -1}. At the silver-solubility limit for x = 0.007, {alpha}{sub 0} = 193.8 {mu}V/K, p = 2.3 Multiplication-Sign 10{sup 18} cm{sup -3}, and {sigma} = 216 {Omega}{sup -1} cm{sup -1}. The hole concentration in all samples is much lower than the concentration of introduced silver atoms. The hole gas in Pb{sub 1-x}Ag{sub x}Te solid solutions is weakly degenerate in the entire silver-concentration range.

36 MATERIALS SCIENCE↗

Understanding Artifacts in Impedance Spectroscopy

Four-terminal measurements of impedance spectra have long been troubled by the presence of high frequency artifacts that typically indicate unphysically large inductive behavior. In this paper, we follow up on the observation of Fleig et al., that voltage and current are necessarily measured in different locations of the potentiostat circuit, and that, typically, the electrometer input is a virtual ground. In this case, the capacitance of coaxial cables that connect sample electrodes to the potentiostat provides a high frequency conduction path to ground, so that some of the current that passes through the sample bypasses the electrometer. In four-electrode measurements, this mechanism produces the observed inductive artifacts. We examine a variety of simulated samples, with calculations compared to measurements of relevant circuits, to quantitatively investigate the nature of the artifacts. Model results agree with measurements when the leakage capacitances are properly included in the circuit analyses. With understanding of the origin of the inductive artifacts, the four-electrode method can be effectively utilized, enabling a combination of two-, three- and four-electrode measurements to be used to best advantage. Finally, using this combination of electrode configurations, temperature dependent measurements of SrTiO 3 , Y 2 O 3 -stabilized ZrO 2 , and In 2 O 3 films deposited on YSZ substrates are presented.

36 MATERIALS SCIENCE↗