Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STRONTIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Imaging antiferromagnetic domain fluctuations and the effect of atomic scale disorder in a doped spin-orbit Mott insulator

Correlated oxides can exhibit complex magnetic patterns. Understanding how magnetic domains form in the presence of disorder and their robustness to temperature variations has been of particular interest, but atomic scale insight has been limited. We use spin-polarized scanning tunneling microscopy to image the evolution of spin-resolved modulations originating from antiferromagnetic (AF) ordering in a spin-orbit Mott insulator perovskite iridate Sr 3 Ir 2 O 7 as a function of chemical composition and temperature. We find that replacing only several percent of lanthanum for strontium leaves behind nanometer-scale AF puddles clustering away from lanthanum substitutions preferentially located in the middle strontium oxide layer. Thermal erasure and reentry into the low-temperature ground state leads to a spatial reorganization of the AF puddles, which nevertheless maintain scale-invariant fractal geometry in each configuration. Our experiments reveal multiple stable AF configurations at low temperature and shed light onto spatial fluctuations of the AF order around atomic scale disorder in electron-doped Sr 3 Ir 2 O 7 .

36 MATERIALS SCIENCE↗

Pascal conductance series in ballistic one-dimensional LaAlO 3 /SrTiO 3 channels

One-dimensional electronic systems can support exotic collective phases because of the enhanced role of electron correlations. We describe the experimental observation of a series of quantized conductance steps within strongly interacting electron waveguides formed at the lanthanum aluminate–strontium titanate (LaAlO 3 /SrTiO 3 ) interface. The waveguide conductance follows a characteristic sequence within Pascal’s triangle: (1, 3, 6, 10, 15, …) e 2 /h , where e is the electron charge and h is the Planck constant. This behavior is consistent with the existence of a family of degenerate quantum liquids formed from bound states of n = 2, 3, 4, … electrons. Our experimental setup could provide a setting for solid-state analogs of a wide range of composite fermionic phases.

Science & Technology - Other Topics↗

Crack Growth Rate at Oxygen Electrode/Electrolyte Interface in Solid Oxide Electrolysis Cells Predicted by Experiment Coupled Multiphysics Modeling

Solid oxide electrolysis cell (SOEC) is a very efficient hydrogen production technology, but the cell degradation is a serious limiting factor for its long-term implementation. Oxygen electrode (OE) delamination is reported to be the critical degradation mechanism. In this study, we present a methodology to understand the delamination failure of the OE due to chemical stress in a better perspective. Several OE configurations were tested: baseline strontium-doped lanthanum cobalt iron oxide (LSCF) single layer design and tantalum-doped strontium cobalt oxide (SCT) - LSCF bilayer designs with different SCT loadings. An electro-chemo-mechanical model is developed to associate the electrochemical behavior of the cell with solid mechanics for calculating crack growth of the cell during long term test. The bilayer configuration with SCT 20 wt% has better performance as it survived in the long-term life test with the least crack length. This study implies that an additional nano-coating of SCT over the OE have improved the species transport and oxygen evolution with reduced chemical stress. As the operating current density decreases, it takes longer time for the cell to reach the delamination with the same critical crack length of 6.5 μ m (∼93% of the electrode/electrolyte interface length). Finally, it was concluded that chemical stress plays a significant role in interface delamination failure, however it may not be the only source of stresses at the interface.

08 HYDROGEN↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Laser Transport System Vacuum Simulations and LED Atom Tracker

MAGIS-100 is an experiment using atom interferometry on strontium atoms in a 100m vacuum chamber. The laser travels through a laser transport system (LTS) before going down the chamber. Two projects were completed over the course of the internship. One project was conducting vacuum simulations on the LTS to ensure it meets the experimental pressure requirement of 10-11 torr. This was done by characterizing the pressure profile with variations in pump size, pump spacing, and orifice size. The initial design of the LTS included one 30 L/s ion pump in the high vacuum (HV) region, a lens mount with holes of diameter 0.788”, and three 150 L/s ion pumps in the ultra-high vacuum (UHV) region. After adjusting these variables, it was concluded that the lens mount holes could be reduced to 0.200” in diameter and one 150 L/s ion pump in the UHV could be removed and still meet the experimental requirements. The other project was to design an LED atom tracker that shows the position of the strontium atoms in the 100m shaft. This will help with public outreach by allowing visitors to have a visual of the experiment. An Arduino Uno and Arduino Due were programmed using classical physics formulas to direct the RGB LED strips to flash in sync with the falling atoms. The requirements for powering and connecting the hardware were calculated and recommendations for scaling the system to 100m were made.

43 PARTICLE ACCELERATORS↗

Isotopic fractionation as in-situ sensor of subsurface reactive flow and precursor for rock failure

Greater utilization of subsurface reservoirs perturbs in-situ chemical-mechanical conditions with wide ranging consequences from decreased performance to project failure. Understanding the chemical precursors to rock deformation is critical to reducing the risks of these activities. To address this need, we investigated the coupled flow-dissolution- precipitation-adsorption reactions involving calcite and environmentally-relevant solid phases. Experimentally, we quantified (1) stable isotope fractionation processes for strontium during calcite nucleation and growth, and during reactive fluid flow; (2) consolidation behavior of calcite assemblages in the common brines. Numerically, we quantified water weakening of calcite using molecular dynamics simulations; and quantified the impact of calcite dissolution rate on macroscopic fracturing using finite element models. With microfluidic experiments and modeling, we show the effect of local flow fields on the dissolution kinetics of calcite. Taken together across a wide range of scales and methods, our studies allow us to separate the effects of reaction, flow, and transport, on calcite fracturing and the evolution of strontium isotopic signatures in the reactive fluids.

42 ENGINEERING↗

Characterization Results for the March 2022 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the March 2022 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed on a single sample replicate. A summary of the analytical results for the 3H evaporator overhead sample includes the following. The measured cesium-137 activity in the 3H evaporator overhead sample is 4.59E+02 dpm/mL which is above the ETP WAC limit of 3.28E+02 dpm/mL. The strontium-90 activity in the 3H evaporator overhead sample is <2.95E+01 dpm/mL. This is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample is <1.92E-02 dpm/mL. This is below the ETP WAC limit of 1.00E+00 dpm/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U-Th-Pb and Rb-Sr measurements on some Apollo 14 lunar samples.

The concentrations of selected elements and elemental ratios in some Apollo 14 samples are presented in a table. Another table shows the isotopic composition of lead and strontium in some Apollo 14 samples. Graphs are provided with lead isotope ratio plots and a strontium evolution diagram. Rb-Sr ages are discussed together with isochron age methods of U-Th-Pb, a primary Pb-Pb isochron, a secondary Pb-Pb isochron, U-Pb concordia age relations, and U-Th-Pb concordia relations. Breccias and some soil samples as well as a basalt sample give evidence of significant enrichment of lead relative to uranium and thorium billions of years ago at the Fra Mauro site.

Tatsumoto, M.↗

Thermionic converter performance with oxide collectors

Thermionic converters using a variety of metal oxide collector surfaces have been fabricated and tested. Both work function and power output data are presented and evaluated. Oxides of barium, strontium, zinc, tungsten and titanium have been incorporated into a variable spacing converter. Tungsten oxide was found to give the highest converter performance and to furnish oxygen for the emitter at the same time. Oxygenated emitters operate at reduced cesium pressure with an increase in electrode spacing. Electron spectroscopy for chemical analysis (ESCA) performed on several tungsten oxide collectors showed cesium penetration of the oxide layer, possibly forming a cesium tungstate bronze. Titanium oxide showed high performance but did not furnish oxygen for the emitter; strontium oxide, in the form of a sprayed layer, appeared to dissociate in the presence of cesium. Sprayed coatings of barium and zinc oxides produced collector work functions of about 1.3 eV, but had excessive series resistance. Lanthanum hexaboride, in combination with oxygen introduced through a silver tube, and cesium produced a low work function collector and better than average performance.

Lieb, D.↗

Improved transistor-controlled and commutated brushless DC motors for electric vehicle propulsion

The development, design, construction, and testing processes of two electronically (transistor) controlled and commutated permanent magnet brushless dc machine systems, for propulsion of electric vehicles are detailed. One machine system was designed and constructed using samarium cobalt for permanent magnets, which supply the rotor (field) excitation. Meanwhile, the other machine system was designed and constructed with strontium ferrite permanent magnets as the source of rotor (field) excitation. These machine systems were designed for continuous rated power output of 15 hp (11.2 kw), and a peak one minute rated power output of 35 hp (26.1 kw). Both power ratings are for a rated voltage of 115 volts dc, assuming a voltage drop in the source (battery) of about 5 volts. That is, an internal source voltage of 120 volts dc. Machine-power conditioner system computer-aided simulations were used extensively in the design process. These simulations relied heavily on the magnetic field analysis in these machines using the method of finite elements, as well as methods of modeling of the machine power conditioner system dynamic interaction. These simulation processes are detailed. Testing revealed that typical machine system efficiencies at 15 hp (11.2 kw) were about 88% and 84% for the samarium cobalt and strontium ferrite based machine systems, respectively. Both systems met the peak one minute rating of 35 hp.

Demerdash, N. A.↗

Long-life high performance fuel cell program

A multihundred kilowatt Regenerative Fuel Cell for use in a space station is envisioned. Three 0.508 sq ft (471.9 cm) active area multicell stacks were assembled and endurance tested. The long term performance stability of the platinum on carbon catalyst configuration suitability of the lightweight graphite electrolyte reservoir plate, the stability of the free standing butyl bonded potassium titanate matrix structure, and the long life potential of a hybrid polysulfone cell edge frame construction were demonstrated. A 18,000 hour demonstration test of multicell stack to a continuous cyclical load profile was conducted. A total of 12,000 cycles was completed, confirming the ability of the alkaline fuel cell to operate to a load profile simulating Regenerative Fuel Cell operation. An orbiter production hydrogen recirculation pump employed in support of the cyclical load profile test completed 13,000 hours of maintenance free operation. Laboratory endurance tests demonstrated the suitability of the butyl bonded potassium matrix, perforated nickel foil electrode substrates, and carbon ribbed substrate anode for use in the alkaline fuel cell. Corrosion testing of materials at 250 F (121.1 C) in 42% wgt. potassium identified ceria, zirconia, strontium titanate, strontium zirconate and lithium cobaltate as candidate matrix materials.

Martin, R. E.↗

Rapid Solidification of Magnetic Oxides

The enhanced control over microstructural evolution inherent in rapid solidification processing techniques are exploited to create novel ceramic magnetic materials. The great sensitivity of magnetic properties to local structure provides a powerful probe both for the study of structure and of microscopic solidification mechanisms. The first system studied is the SrO-Fe2O3 binary, which contains the commercially important hard magnetic compound strontium hexaferrite. The products were analyzed by transmission electron microscopy, Mossbauer spectroscopy, magnetic measurements, and differential thermal analysis. As-quenched ribbons contain high concentrations of super-paramagnetic particles, 80 to 250 Angstroms in diameter, in a glassy matrix. This suggests the possibility of crystallizing monodomain strontium hexaferrite during subsequent heat treatment, with a resulting increase in coercivity over conventionally processed ferrite magnets. That magnetic properties can be controlled in solidification processing by varying the quench rate is demonstrated.

Kalonji, G.↗

Effect of space exposure on pyroelectric infrared detectors

Twenty pyroelectric type infrared detectors were flown onboard the Long Duration Exposure Facility (LDEF). The detector chips were of three different pyroelectric materials: lithium-tantalate, strontium-barium-niobate, and triglycine-sulfide. The experiment was passive; no measurements were taken during the flight. Performance of the detectors was measured before and after flight. Postflight measurements revealed that detectors made of lithium-tantalate and strontium-barium-niobate suffered no measureable loss in performance. Detectors made of triglycine-sulfide suffered complete loss of performance, but so did the control samples of the same material. Repoling of the triglycine-sulfide failed to revive the detectors.

Robertson, James B.↗

High-T sub c fluorine-doped YBa2Cu3O(y) films on ceramic substrates by screen printing

Thick films of fluorine-doped YBa2Cu3O(y) were screen printed on highly polished alumina, magnesia spinel, strontium titanate, and yttria-stabilized zirconia (YSZ) substrates. They were annealed at 1000 C and soaked in oxygen at 450 C, followed by slow cooling to room temperature. The films were characterized by electrical resistivity measurements as a function of temperature and x-ray diffraction. The film on YSZ showed the best characteristics with a T sub c (onset) of 91 K, T sub c (R equals 0) of 88.2 K, and a transition width, delta T sub c (10-90 percent), of approximately 1.7 K. The film adhesion, probably controlled by interdiffusion of cations between the film and the substrate, was good in all cases except on strontium titanate where the film completely detached from the substrate.

Bansal, Narottam P.↗

Modelling the Phanerozoic carbon cycle and climate - Constraints from the Sr-87/Sr-86 isotopic ratio of seawater

A numerical model is developed for simulating the long-term changes of atmospheric CO2 and climate during the Phanerozoic. The model describes the coupled evolution of the biogeochemical cycles of C, S, Ca, Mg, P, and Sr, with the emphasis on the effect of coupling the cycles of carbon and strontium and on interpreting the observed seawater Sr-87/Sr-86 ratios. The abilities of continental weathering, volcanism, and surface lithology in generating that signal are tested and compared. The results obtained are used to reconstruct a history of atmospheric CO2 and climate during Phanerozoic time, consistent with the strontium isotopic data. It is shown that the predicted history is compatible with paleoclimatic indicators, such as the timing of glaciation and the estimates of Cretaceous paleotemperatures.

Francois, Louis M.↗

High temperature sensor/microphone development for active noise control

The industrial and scientific communities have shown genuine interest in electronic systems which can operate at high temperatures, among which are sensors to monitor noise, vibration, and acoustic emissions. Acoustic sensing can be accomplished by a wide variety of commercially available devices, including: simple piezoelectric sensors, accelerometers, strain gauges, proximity sensors, and fiber optics. Of the several sensing mechanisms investigated, piezoelectrics were found to be the most prevalent, because of their simplicity of design and application and, because of their high sensitivity over broad ranges of frequencies and temperature. Numerous piezoelectric materials are used in acoustic sensors today; but maximum use temperatures are imposed by their transition temperatures (T(sub c)) and by their resistivity. Lithium niobate, in single crystal form, has the highest operating temperature of any commercially available material, 650 C; but that is not high enough for future requirements. Only two piezoelectric materials show potential for use at 1000 C; AlN thin film reported to be piezoactive at 1150 C, and perovskite layer structure (PLS) materials, which possess among the highest T(sub c) (greater than 1500 C) reported for ferroelectrics. A ceramic PLS composition was chosen. The solid solution composition, 80% strontium niobate (SN) and 20% strontium tantalate (STa), with a T(sub c) approximately 1160 C, was hot forged, a process which concurrently sinters and renders the plate-like grains into a highly oriented configuration to enhance piezo properties. Poled samples of this composition showed coupling (k33) approximately 6 and piezoelectric strain constant (d33) approximately 3. Piezoactivity was seen at 1125 C, the highest temperature measurement reported for a ferroelectric ceramic. The high temperature piezoelectric responses of this, and similar PLS materials, opens the possibility of their use in electronic devices operating at temperatures up to 1000 C. Concurrent with the materials study was an effort to define issues involved in the development of a microphone capable of operation at temperatures up to 1000 C; important since microphones capable of operation above 260 C are not generally available. The distinguishing feature of a microphone is its diaphragm which receives sound from the atmosphere: whereas, most other acoustic sensors receive sound through the solid structure on which they are installed. In order to gain an understanding of the potential problems involved in designing and testing a high temperature microphone, a prototype was constructed using a commercially available lithium niobate piezoelectric element in a stainless steel structure. The prototype showed excellent frequency response at room temperature, and responded to acoustic stimulation at 670 C, above which temperature the voltage output rapidly diminished because of decreased resistivity in the element. Samples of the PLS material were also evaluated in a simulated microphone configuration, but their voltage output was found to be a few mV compared to the 10 output of the prototype.

Shrout, Thomas R.↗

The Ejecta of Eta Carinae as Studied by STIS

The Space Telescope Imaging Spectrograph has been used to study the emission and absorption spectra of ejecta surrounding Eta Carinae. Discussion will be presented on the overall structure of the Homunculus, the Weigelt blobs and the Strontium filament. Three visits have been accomplished with the Position Angle precisely the same and covering the Central Source and Weigelt Blobs B and D. Deep spectra have been done at several positions to obtain the overall velocity structure of the Homunculus and the disk region. Mapping has been done with the STIS medium dispersion gratings set near H beta and H alpha. We have obtained full coverage of the strontium filament from 1640 Angstroms to 10300 Angstroms. The structure and physical properties will be described.

Gull, Theodore R.↗

Multilayer article having stabilized zirconia outer layer and chemical barrier layer

A multilayer article includes a substrate that includes at least one of a ceramic compound and a Si-containing metal alloy. An outer layer includes stabilized zirconia. Intermediate layers are located between the outer layer and the substrate and include a mullite-containing layer and a chemical barrier layer. The mullite-containing layer includes 1) mullite or 2) mullite and an alkaline earth metal aluminosilicate. The chemical barrier layer is located between the mullite-containing layer and the outer layer. The chemical barrier layer includes at least one of mullite, hafnia, hafnium silicate and rare earth silicate (e.g., at least one of RE.sub.2 SiO.sub.5 and RE.sub.2 Si.sub.2 O.sub.7 where RE is Sc or Yb). The multilayer article is characterized by the combination of the chemical barrier layer and by its lack of a layer consisting essentially of barium strontium aluminosilicate between the mullite-containing layer and the chemical barrier layer. Such a barium strontium aluminosilicate layer may undesirably lead to the formation of a low melting glass or unnecessarily increase the layer thickness with concomitant reduced durability of the multilayer article. In particular, the chemical barrier layer may include at least one of hafnia, hafnium silicate and rare earth silicate.

Lee, Kang N.↗