Overview of the MSTI 2 on-orbit alignment

The Miniature Sensor Technology Integration (MSTI) 2 Spacecraft is a small 3-axis stabilized spacecraft designed to track mid-range missiles and estimate their state vectors. In order to accurately estimate the target state vector, the MSTI 2 spacecraft must have highly accurate knowledge of its own attitude. Errors in its attitude knowledge arise primarily from the errors in its Attitude Control System (ACS) sensors. The ACS sensors on the spacecraft include a scanning Earth Sensor (ES), a Sun Sensor (SS), and two 2-axis gyros. The On-Orbit Alignment (OOA) generated an error map of the ES and estimated the biases of the SS and the misalignment of the gyros. This paper discusses some of the error sources, and the techniques used to reduce the effects of these errors. The payload carried by the MSTI2 spacecraft is a high fidelity camera, which was aimed at the target using gimballed mirrors. By aiming it at a celestial target, the payload was used as a high-accuracy single-axis attitude reference. This attitude reference was compared to the attitude reference of the ACS sensors, and the errors were attributed to the ACS sensors.

Rygaard, Christopher A.↗

Mercury - Full-disk radar images and the detection and stability of ice at the North Pole

The first full-disk radar images of Mercury are discussed. About 77 percent of the surface was imaged at resolutions as good as 150 km. The North Pole was visible at the time of the observations, and the feature with the highest same sense (SS) circular reflectivity in the images is near the nominal polar position. The peak SS reflectivity of this feature is 7.9 percent and the circular polarization ratio through much of it is over one. The diameter of the feature is estimated to be less than about 350 km. The signal strength and polarization characteristics suggest the presence of very clean ices deposited in a relatively short period. The reflectivity of the north polar feature is slightly depressed compared to absolute reflectivities of other ice bodies and regions in the solar system. This may be due to a layer of dust or soil covering the ice. Other prominent features in the unphotographed hemisphere correpond to positions where atmospheric sodium enhancements have been measured from earth. These sites may be large basins similar to the Caloris basin.

Butler, Bryan J.↗

Design considerations for a Space Station radiation shield for protection from both man-made and natural sources

This study was conducted to analyze scenarios involving the use of nuclear-power vehicles in the vicinity of a manned Space Station (SS) in low-earth-orbit (LEO) to quantify their radiological impact to the station crew. In limiting the radiant dose to crew members, mission planners may (1) shut the reactor down prior to reentry, (2) position the vehicle at a prescribed parking distance, and (3) deploy radiation shield about the shutdown reactor. The current report focuses on the third option in which point-kernel gamma-ray shielding calculations were performed for a variety of shield configurations for both nuclear electric propulsion (NEP) and nuclear thermal rocket (NTR) vehicles. For a returning NTR vehicle, calculations indicate that a 14.9 MT shield would be needed to limit the integrated crew exposure to no more than 0.05 Sv over a period of six months (25 percent of the allowable exposure to man-made radiation sources). During periods of low vehicular activity in LEO, the shield may be redeployed about the SS habitation module in order to decrease crew exposures to trapped proton radiations by approximately a factor of 10. The corresponding shield mass required for deployment at a returning NEP vehicle is 2.21 MT. Additional scenarios examined include the radioactivation of various metals as might be found in tools used in EVA activities.

Bolch, Wesley E.↗

Evolution of magnetized protoplanetary disks

We investigate the global evolution of a turbulent protoplanetary disk in its viscous stage, incorporating the effects of Maxwell stress due to a large-scale magnetic field permeating disk. We assume that the viscous stress is given by an alpha model. A magnetic field is produced contemporaneously by an alpha omega dynamo mechanism and the resultant Maxwell stress assists the viscous stress in providing the means for disk evolution. The aim of this work is to compare the evolution of magnetized and nonmagnetized disks driven by turbulent viscosity of the same magnitude and thus assess the effects of a self-generated magnetic field on the structure and dynamical evolution of protoplanetary disks. Two illustrative examples corresponding to two different initial conditions are considered: a high-mass case that starts with a disk of 0.245 solar mass and angular momentum of 5.6 x 10(exp 52)g sq cm/s, and a low-mass that case starts with a disk of 0.11 solar mass and angular momentum of 1.8 x 10(exp 52)g sq cm/s. For each of these two cases the radial development of a disk is calculated numerically assuming a fiducial value of the dimensionless viscosity parameter alpha(sub ss) = 0.01, as well as alpha(sub ss) = 2 x 10(exp -3). In all cases the central star has a mass equal to 1 solar mass. The most striking feature of magnetized disk evolution is the presence of the surface density bulge located in the region of the disk where the dynamo mechanism cannot support a magnetic field. The bulge persists for a time of the order of 10(exp 5)-10(exp 6) yr. The presence and persistence of the surface density bulge may have important implications for the process of planet formation and the overall characteristics of resultant planetary systems.

Reyes-Ruiz, Mauricio↗

Diffusion of Na and K in the uppermost regolith of Mercury

We examine the conditions under which ions impacting the Hermean surface can act as a regional source of enhanced atmospheric column through ion implantation and subsequent release at the surface. At most latitudes, energetic (a few keV) Na or K ions which impact the nightside surface, are released quickly (well before noon) upon warming of the surface. We show that the relative sunrise/sunset difference produced by ion implantation is ((n)(sub SR) - (n)(sub SS)/(n)(sub Ave) = f, where f is the fraction of the photo-ions recycled, (n)(sub SR) is the average zenith column above the sunrise portion of the illuminated hemisphere, (n)(sub SS) is the average zenith column in the sunset portion, and (n)(sub Ave) is the average column over the sunlit disk. Thus, to produce a large sunrise/sunset difference via ion implantation and subsequent release requires efficient (close to total) recycling. We show that the most extensive set of available data reduced to Na column abundance does not show any sunrise enhancement. We argue that the K data do not permit an unambiguous interpretation in favor of sunrise/sunset differences. We further find that if an efficient surface loss process for the alkali is not operating after sunrise, the initial Na and K distribution will relax into the bulk of the solid. Preserved abundance gradients of Na and K in lunar glasses that the Arrhenius coefficients for impact glasses are likely more modest than those for laboratory glasses derived from rock by nonimpact processes, but the effect of the more modest diffusion rates is only to delay the efficient loss of Na by a few Earth days. We argue that implantation can lead to observable regional increases in the observed Na or K column densities only if it occurs at very high latitudes, where diffusion is slow. It is typically lower energy ions which impact at high latitude and these are both more numerous than the high energy ions and possess smaller average penetration depths; thus there are additional reasons to favor a high-latitude locus for any possible prompt return related increases in zenith column. We find that we cannot rule out sputtering as a source process, as the low-energy ions are efficient sputterers. Finally, we argue that the observed Na/K ratio in the atmopshere may be the expression of their different asymptotic rates of loss from the interiors of the regolith grains. If so, this allows us to fix the importance of sputtering and photon stimulated desorption relative to impact vaporization.

Killen, R. M.↗

Verification of Experimental Techniques for Flow Surface Determination

The concept of a yield surface is central to the mathematical formulation of a classical plasticity theory. However, at elevated temperatures, material response can be highly time-dependent, which is beyond the realm of classical plasticity. Viscoplastic theories have been developed for just such conditions. In viscoplastic theories, the flow law is given in terms of inelastic strain rate rather than the inelastic strain increment used in time-independent plasticity. Thus, surfaces of constant inelastic strain rate or flow surfaces are to viscoplastic theories what yield surfaces are to classical plasticity. The purpose of the work reported herein was to validate experimental procedures for determining flow surfaces at elevated temperatures. Since experimental procedures for determining yield surfaces in axial/torsional stress space are well established, they were employed -- except inelastic strain rates were used rather than total inelastic strains. In yield-surface determinations, the use of small-offset definitions of yield minimizes the change of material state and allows multiple loadings to be applied to a single specimen. The key to the experiments reported here was precise, decoupled measurement of axial and torsional strain. With this requirement in mind, the performance of a high-temperature multi-axial extensometer was evaluated by comparing its results with strain gauge results at room temperature. Both the extensometer and strain gauges gave nearly identical yield surfaces (both initial and subsequent) for type 316 stainless steel (316 SS). The extensometer also successfully determined flow surfaces for 316 SS at 650 C. Furthermore, to judge the applicability of the technique for composite materials, yield surfaces were determined for unidirectional tungsten/Kanthal (Fe-Cr-Al).

Lissenden, Cliff J.↗

Effects of Prostaglandin E2 and Risedronate Administration on Cancellous Bone in Older Female Rats

The effects of Prostaglandin E2 (PGE2) and Risedronate (Ris) both separately and in combination (PGE2 + Ris) were studied on the intact aged female rat skeleton to determine whether the combination of PGE2 with an antiresorptive agent is more effective anabolically than PGE2 alone. Nine month-old Sprague-Dawley rats were injected subcutaneously either with vehicle, 6 mg PGE2/kg per day, 1 or 5 microgram Ris/kg twice a week, or 6 mg PGE2/kg per day plus 1 or 5 microgram Ris/kg twice a week (PGE2 + 1 Ris or PGE2 + 5 Ris) for 60 days. After the treatment, we determined the longitudinal bone growth rate, the qualitative appearance of the primary spongiosa (PS), and the static and dynamic bone histomorphometry of the secondary spongiosa (SS) of the proximal tibial metaphysis (PTM) by examining undecalcified longitudinal sections after double fluorescent labeling. The relative effects of these treatments on longitudinal bone growth were ranked as follows: PGE2 + 5 Ris greater than PGE2 + 1 Ris = basal greater than PGE2 greater than 1 microgram Ris = 5 microgram Ris = aging. The density of the PS was ranked as follows: PGE2 + 5 Ris greater than PGE2 + 1 Ris = PGE2 = 5 microgram Ris = 1 microgram Ris greater than basal = aging. The increase in density of the PS was the result of stimulated longitudinal growth and the action of bisphosphonate. Bone mass in the SS was ranked as follows: PGE2 + 5 Ris = PGE2 + 1 Ris = PGE2 greater than 5 microgram Ris = 1 microgram Ris = aging = basal. However, PGE2 alone and its cotreatment with Ris accumulated bone by different tissue mechanisms. PGE2 alone created new bone by increasing activation frequency 8.3-fold and the formation to resorption ratio 1.3-fold from the controls. The combination of PGE2 and Ris depressed activation frequency (-54% to -74%), and bone formation rate (tissue-based -31%, and bone-based -42%) and eroded surface (-79% to -81%), so as to increase the formation to resorption ratio (three- to four-fold) over PGE2 alone. The increased ratio was due primarily to a greater decrease in eroded perimeter than in labeled perimeter. The major finding of this study is that the combination of PGE2 and a bisphosphonate (Ris) is more anabolic than PGE2 or Ris alone when endochondral ossification is active, but PGE2 + Ris is no more anabolic than PGE2 alone in old bone without endochondral ossification. However, the tissue mechanisms by which PGE2 alone and PGE2 + Ris treatments accumulated bone differed in that the latter allowed the same bone mass to accumulate with lower levels of cell recruitment and activity.

Lin, B. Y.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Galaptin Mediates the Effect of Hypergravity on Vascular Smooth Muscle cell (SMC) Adhesion to Laminin Containing Matrices

Galaptin, an endogenous beta-galactoside specific lectin, has been reported to bind to laminin and subsequently decrease the binding of SMC. Cellular function depend on cell:matrix interactions. Hypergravity (HGrav) affect a number of cellular functions, yet little is known about its affect on cell adhesion. We examined the possibility that galaptin mediates the effects of hypergravity on SMC adherence. Confluent primate aorta SMC cultures were subjected to Hgrav (centrifuged at 6G) for 24 and 48 hr. Cells were non-enzymatically dispersed, pretreated with antisense (AS-oligo) or control sense (SS-oligo) oligonucleotides to galaptin mRNA (0.01 micro g/ml), then seeded in uncoated or ECL-matrix coated plates. Adhesion of cells were monitored after 6 hr. HGrav increased adhesion by 100-300% compared to controls. AS-oligo decreased adhesion for both HGrav and control cells. SS-oligo did not affect adhesion for either HGrav or control cells. These studies show that HGrav affects cell adhesion and that galaptin expression is required for this effect.

Enahora, Fatisha T.↗

Prediction of Coronal Mass Ejections from Vector Magnetograms: Results from More Active Regions

In a previous pilot study of four predominantly bipolar active regions observed by the MSFC vector magnetograph in 1991-92, we found that two quantitative measures of the global nonpotentiality of an active region were promising predictors of whether the active region produced coronal mass ejections (CMES) during its rotation across the Sun. The two quantitative measures are 1) the length (L(sub ss)) of the segments along the active region's main neutral line on which the vector magnetic field is both strong and strongly sheared, and 2) the global net current (I(sub N) flowing up one side of the bipole and down the other. Two of the active regions had large measured global nonpotentiality (L(sub ss) approximately >10(exp 5) km and I(sub N) approximately >4x 10(exp 12) Amp) and produced three CMEs each. The other two active regions had much smaller measured global nonpotentiality and produced no CMES. We have now expanded our sample of active regions by a factor of 3 with active regions from 1991 to the present. We have calibrated the line-of-sight magnetic field by comparing it to the line-of-sight field measured by Kitt Peak and/or SOHO/MDI. We have resolved the 180 deg. ambiguity in the transverse field by using three different methods, and compared the resulting global net currents. We will compare the two measures of global nonpotentiality to each other and to the CME productivity of each active i-eolon in our expanded set. We will examine the extent to which these results from the expanded set confirm or modify the tentative rule for CME prediction that we found in our pilot study.

Falconer, D. A.↗

Prediction of Coronal Mass Ejections From Vector Magnetograms: Quantitative Measures as Predictors

We derived two quantitative measures of an active region's global nonpotentiality from the region's vector magnetogram, 1) the net current (I(sub N)), and 2) the length of strong-shear, strong-field main neutral line (Lss), and used these two measures in a pilot study of the CME productivity of 4 active regions. We compared the global nonpotentiality measures to the active regions' CME productivity determined from GOES and Yohkoh/SXT observations. We found that two of the active regions were highly globally nonpotential and were CME productive, while the other two active regions had little global nonpotentiality and produced no CMEs. At the Fall 2000 AGU, we reported on an expanded study (12 active regions and 17 magnetograms) in which we evaluated four quantitative global measures of an active region's magnetic field and compared these measures with the CME productivity. The four global measures (all derived from MSFC vector magnetograms) included our two previous measures (I(sub N) and L(sub ss)) as well as two new ones, the total magnetic flux (PHI) (a measure of an active region's size), and the normalized twist (alpha (bar)= muIN/PHI). We found that the three quantitative measures of global nonpotentiality (I(sub N), L(sub ss), alpha (bar)) were all well correlated (greater than 99% confidence level) with an active region's CME productivity within plus or minus 2 days of the day of the magnetogram. We will now report on our findings of how good our quantitative measures are as predictors of active-region CME productivity, using only CMEs that occurred after the magnetogram. We report the preliminary skill test of these quantitative measures as predictors. We compare the CME prediction success of our quantitative measures to the CME prediction success based on an active region's past CME productivity. We examine the cases of the handful of false positive and false negatives to look for improvements to our predictors. This work is funded by NSF through the Space Weather Program and by NASA through the Solar Physics Supporting Research and Technology Program.

Falconer, D. A.↗

Correlation of the Coronal Mass Ejection Productivity of Solar Active Regions with Measures of their Global Nonpotentiality from Vector Magnetograms: Baseline Results

Conventional magnetograms and chromospheric and coronal images show qualitatively that the fastest coronal mass ejections (CMEs) are magnetic explosions from sunspot active regions where the magnetic field is globally strongly sheared and twisted from its minimum-energy potential configuration. We present measurements from active region vector magnetograms that start to quantify the dependence of an active region's CME productivity on the global nonpotentiality of its magnetic field. From each of 17 magnetograms of 12 bipolar active regions, we measured the size of the active region (the magnetic flux content, phi) and three separate measures of the global nonpotentiality (L(sub SS), the length of strong-shear, strong-field main neutral line: I(sub N), the net electric current connecting one polarity to the other; and alpha = (mu)I(sub N)/phi), a flux normalized measure of the field twist). From these measurements and the observed CME productivity of the active regions, we find that: (1) All three measures of global nonpotentiality are statistically correlated with the active region flux content and with each other; (2) All three measures of global nonpotentiality are significantly correlated with CME productivity. The flux content correlates with CME productivity, but at a lower statistically significant confidence level (less than 95%); (3) The net current is less closely correlated with CME productivity than alpha and the correlation of CME productivity with flux content is even weaker. If these differences in correlation strength, and a significant correlation of alpha with flux content, persist to larger active regions, this would imply that the size of active regions does not affect CME productivity except through global nonpotentiality; and (4) For each of the four global magnetic quantities, the correlation with CME productivity is stronger for a two-day time window for the CME production than for windows half as wide or twice as wide. This plausibly is a result of the most counterproductive active regions producing less than one CME per day, and from the active region's evolution often significantly changing the global nonpotentiality over the course of several days. These results establish that measures of active region global nonpotentiality from vector magnetograms (such as L(sub SS), I(sub N), and alpha) should be useful for prediction a active region CMEs.

Falconer, D. A.↗

Forecasting Coronal Mass Ejections from Vector Magnetograms

In a 17 vector magnetogram study of 12 bipolar active regions (Falconer, Moore, & Gary, 2002, ApJ in press), we correlated four quantitative global magnetic measures with the Coronal Mass Ejections (CME) productivity of the active region. The global measures included a measure of active region size, the total magnetic flux phi and three measures of an active region global nonpotentiality 1) the net current (I (sub N)), 2) the length of the strong-shear, strong-field main neutral line (L(sub SS)) and 3) and the normalized twist (alpha = muIN/PHI). The CME productivity was determined from YOHKOH/SXT observations, Geostationary Operational Environmental Satellite (GOES), and when possible Solar and Heliospheric Observatory/Large Angle and Spectrometric Coronagraph Experiment (SOHO/LASCO) observations within 12 days of the day of the magnetogram. We found that the three measures of global nonpotentiality (I(sub N), L(sub SS), alpha) were all well correlated (greater than 99% confidence level) with an active region's CME productivity. The sample size was to small to confirm if there was a statistical significant correlation of the globally nonscientist measures with future CME activity (i.e. from the date of the magnetogram forward). We are doubling our sample, and will report on the statistical significance of global nonpotentiality as a predictor of future CME productivity. The new active regions are all from the first year of the upgraded MSFC vector magnetograms. This work, is funded by NSF through the Space Weather Program, by NASA through the Living with the Star, Targeted Research and Technology, and by NASA Solar Physics Supporting Research and Technology Program. The upgrade to the MSFC vector magnetograph was supported by the High Energy Solar Spectroscopic Imager (HESSI) mission.

Falconer, D. A.↗

Carboxylic and Dicarboxylic Acids Extracted from Crushed Magnesium Oxide Single Crystals

Carboxylic and dicarboxylic acids (glycolic, oxalic, malonic and succinic) have been extracted with tetrahydrofuran (THE) and H2O from large synthetic MgO crystals, crushed to a medium fine powder. The extracts were characterized by infrared spectroscopy and (sup 1)H-NMR (Nuclear Magnetic Resonance). The THF extracts were derivatized with tert-butyldimethylsilyl (t-BDMS) for GC-MS (Gas Chromatography - Mass Spectroscopy) analysis. A single crystal separated from the extract was used for an x-ray structure analysis, giving the monoclinic unit cell, space group P2(sub 1)/c with a(sub o) = 5.543 A, b(sub o) = 8.845 A, c(sub o) = 5.086 A, and beta = 91.9 degrees, consistent with beta-succinic acid, HOOC(CH2)COOH. The amount of extracted acids is estimated to be of the order of 0.1 to 0.5 mg/g MgO. The MgO crystals from which these organic acids were extracted grew from the 2360 C hot melt, saturated with CO/CO2 and H2O, thereby incorporating small amounts of the gaseous components to form a solid solution (ss) with MgO. Upon cooling, the ss becomes supersaturated, causing solute carbon and other solute species to segregate not only to the surface but also internally, to dislocations and subgrain boundaries. The organic acids extracted from the MgO crystals after crushing appear to derive from these segregated solutes that formed C-C, C-H, and C-O bonds along dislocations and other defects in the MgO structure, leading to entities that can generically be described as (HxCyOz)(sup n-). The processes underlying the formation of these precursors are fundamental in nature and expected to be operational in any minerals, preferentially those with dense structures, that crystallized in H2O-CO2-laden environments. This opens the possibility that common magmatic and metamorphic rocks when weathering at the surface of a tectonically active planet like Earth may be an important source of abiogenically formed complex organic compounds.

Freund, Friedemann↗

Gas Sensor

High Technology Sensors, Inc.'s Model SS-250 carbon dioxide detector uses a patented semiconductor optical source that efficiently creates infrared radiation, which is focused through an airway on a detector. Carbon dioxide passing through the airway absorbs the radiation causing the detector to generate a signal. The small size and low power requirements of the SS-250 make it attractive for incorporation in a variety of medical instruments.

Source record↗

CME Prediction from Line-of-Sight Magnetogram

We have previously shown for bipolar active regions that measures of active-region nonpotentiality from vector magnetograms are correlated with active-region CME productivity. We have now obtained a measure from line-of-sight magnetograms that is well correlated both with our measures of active-region nonpotentiality from vector magnetograms and with active-region CME productivity. The measure is the length of strong-gradient main neutral line (L(sub G)). This is the length of the bipolar region's main neutral line on which the potential transverse field is greater than 150G, and the gradient in the line-of-sight field is greater than 50G/Mm. From the sample of 17 MSFC magnetograms of 12 basically bipolar active regions used in our previous paper, we find that L(sub G) is strongly correlated with one of our vector-magnetogram measures of nonpotentiality, the length of strong-gradient main neutral line L(sub SS) (99.7%). We also find that L(sub G) is as strongly correlated with CME productivity (99.7%) as is L(sub SS). Being obtainable from line-of-sight magnetograms, L(sub G) makes the much larger data set of line-of-sight magnetograms (i.e. from SOHO/MDI and Kitt Peak) available for CME prediction study. This is especially important for evolutionary studies, with SOHO/MDI having no daylight, cloudy weather, or atmospheric seeing problems. This work was supported by funding from NSF's division of Atmospheric Sciences (Space Weather and Shine Programs) and by NASA's office of Space Science (Living with a Star program Solar and Heliospheric Physics Supporting Research and Technology program).

Falconer, D. A.↗

Prediction of Active-Region CME Productivity from Magnetograms

We report results of an expanded evaluation of whole-active-region magnetic measures as predictors of active-region coronal mass ejection (CME) productivity. Previously, in a sample of 17 vector magnetograms of 12 bipolar active regions observed by the Marshall Space Flight Center (MSFC) vector magnetograph, from each magnetogram we extracted a measure of the size of the active region (the active region s total magnetic flux a) and four measures of the nonpotentiality of the active region: the strong-shear length L(sub SS), the strong-gradient length L(sub SG), the net vertical electric current I(sub N), and the net-current magnetic twist parameter alpha (sub IN). This sample size allowed us to show that each of the four nonpotentiality measures was statistically significantly correlated with active-region CME productivity in time windows of a few days centered on the day of the magnetogram. We have now added a fifth measure of active-region nonpotentiality (the best-constant-alpha magnetic twist parameter (alpha sub BC)), and have expanded the sample to 36 MSFC vector magnetograms of 31 bipolar active regions. This larger sample allows us to demonstrate statistically significant correlations of each of the five nonpotentiality measures with future CME productivity, in time windows of a few days starting from the day of the magnetogram. The two magnetic twist parameters (alpha (sub 1N) and alpha (sub BC)) are normalized measures of an active region s nonpotentially in that they do not depend directly on the size of the active region, while the other three nonpotentiality measures (L(sub SS), L(sub SG), and I(sub N)) are non-normalized measures in that they do depend directly on active-region size. We find (1) Each of the five nonpotentiality measures is statistically significantly correlated (correlation confidence level greater than 95%) with future CME productivity and has a CME prediction success rate of approximately 80%. (2) None of the nonpotentiality measures is a significantly better CME predictor than the others. (3) The active-region phi shows some correlation with CME productivity, but well below a statistically significant level (correlation confidence level less than approximately 80%; CME prediction success rate less than approximately 65%). (4) In addition to depending on magnetic twist, CME productivity appears to have some direct dependence on active-region size (rather than only an indirect dependence through a correlation of magnetic twist with active-region size), but it will take a still larger sample of active regions (50 or more) to certify this. (5) Of the five nonpotentiality measures, L(sub SG) appears to be the best for operational CME forecasting because it is as good or better a CME predictor than the others and it alone does not require a vector magnetogram; L(sub SG) can be measured from a line-of-sight magnetogram such as from the Michelson Doppler Imager (MDI) on the Solar and Heliospheric Observatory (SOHO).

Falconer, D. A.↗