Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Demonstration of Magnetron as an Alternative RF Source for SRF Accelerators

Magnetron has been considered as alternate high-efficiency, low-cost RF sources for linacs and storage rings [1] for national labs and industrial applications. After the demonstration of magnetrons power to drive and combine for a radio frequency cavity at 2450 MHz in CW mode, we have used trim coils adding to a water-cooled magnetron and amplitude modulation feedback to further suppress the side-band noise to -46.7 dBc level. We also demonstrated the phase-locking to an industrial grade cooking magnetron transmitter at 915 MHz with a 75 kW CW power delivered to a water load by using a -26.6 dBc injection signal [2]. The sideband noise from the 3-Phase SCRs DC power supply can be reduced to -16.2 dBc level. Further noise reduction and their power combining scheme using magic-tee and cavity type combiners for higher power application (2x75kW) are to be presented. We intent to use one power station to drive the normal conducting and superconducting RF cavities for the inductrial linac. We also going to demonstarte a vertical SRF cavity test with a high input coupling Q using a 2.45GHz magnetron and comparing with a baseline test result using a solid state amplifier.

Wang, H.↗

Developing Conduction-Cooled SRF Cavities and First Test Results [Slides]

Summary and Future Work: Development of conduction cooling for SRF; practical thermal link design; experimental setup ready; first results are promising; 6.6 MV/m cwrecorded on a single cell 650 MHz Nb3Sn cavity Activities: ongoing and planned; improve magnetic hygiene of our cryostat; test with improved Nb3Sn coating; and identity and mitigate potential microphonics due to cryocooler vibrations.

43 PARTICLE ACCELERATORS↗

Plasma Processing of SRF Cavities for the Next Generation of Particle Accelerators

What are the major goals of the project? Goal 1: Optimize interactively processing of the single-cell cavity by combining plasma treatment and vertical cold bath testing. Continue using single cell cavity as the test bed for new applications. Goal 2: Work on upgrading the plasma etching technology for multi-cell SRF cavities. Goal 3: Develop and adapt discharge configurations to critical cavity regions including the electron beam weld (EBW) and iris areas. Goal 4: Develop tailored methods to prepare surface properties for a specific function prior to any additional modification, such as (but not limited to) surface passivation in preparation of other superconducting materials and structures.

43 PARTICLE ACCELERATORS↗

Novel High-Current SRF Cavity With On-Cell Waveguide Dampers

A new concept was proposed to improve the Higher-Order-Mode (HOM) damping in Superconducting Radio Frequency (SRF) cavities beyond state-of-the-art. A prototype cavity was planned to be built and tested in JLab’s Vertical Test Area as a proof-of-principle.

42 ENGINEERING↗

Cryocooler conduction-cooled SRF accelerator design for industrial applications

Principal Investigator Dr. Ram Dhuley has led R&D efforts at the U.S. Department of Energy's Fermi National Accelerator Laboratory to design a cryocooler conduction-cooled SRF accelerator for e-beam irradiation treatment of wastewater. This is a spotlight on the accelerator design and its enabling core technologies.

43 PARTICLE ACCELERATORS↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become “standard” components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Technical Report: Innovative Magnetron Power Sources for Superconducting RF (SRF) Accelerators

In this project, MUONS is designing and building custom magnetrons at Richardson Electronics (RELL) to test the predictions of the models and make improvements to the designs to match the needs of NP SRF accelerators and their life-cycle costs. To increase lifetime, the filament temperature is controlled by a feedback circuit that includes a model of back streaming of electrons. The gain of the magnetron is optimized by the design of an input port. A permanent magnet design with trim coil for amplitude adjustment reduces energy consumption. Moving the construction of the magnetron from prototype to manufacturing includes the utilization of RELL processes and designs. To the extent that outgassing of materials influences the lifetime of the magnetron, methods for minimizing outgassing was explored. Further experimentation of the potential of sub-critical voltage operation continues to be explored. The commercialization goal of the project will be naturally achieved as RELL already has world-wide marketing, sales, and support to exploit the assembly-line capabilities generated by this project to enable magnetron technologies for NP accelerators.

43 PARTICLE ACCELERATORS↗

Two-Tone Spectroscopy of 3D SRF Cavities to Understand Two-Level System Loss

So-called two-level system (TLS) defects are among the most detrimental sources of loss and decoherence in superconducting quantum devices, and their microscopic nature still poorly understood. We develop a two-tone spectroscopy technique to characterize the spectral line width of TLS. This knowledge will help to distinguishes various types of TLS defects. In our experiments we use the fundamental TM010 pass band modes of 9-cell elliptical SRF cavities to probe spectral properties of TLS in native niobium oxide formed on the inside walls of the resonator. We pump one of the modes (4¿/9 through 8¿/9) with continuous high-power to saturate TLSs that couple to this frequency, and we probe the Q-factor of the ¿-mode. We observe increase of the quality factor of the probed ¿-mode when one of the neighboring modes is pumped. Extremely high quality factors of the pass band modes and their relative proximity in the frequency space allow us to estimate the width of the spectral hole burned in the TLS bath absorption spectrum which is related to the line spectral width of the TLS defects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

Research and Development of Advanced Superconducting Radiofrequency (SRF) Accelerator Technology and Components for Scientific and Industrial Applications

The purpose of this CRADA is to provide for the joint conduct of research and development (R&D) investigations between Fermi Research Alliance, LLC (Contractor), as operator of the Fermi National Accelerator Laboratory (Fermilab) and Euclid TechLabs, LLC (Participant) related to Research and Development of Advanced Superconducting Radiofrequency (SRF) Accelerator Technology and Components for Scientific and Industrial Applications.

43 PARTICLE ACCELERATORS↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

Recent advances in metallographic polishing for SRF application

This paper is an overview of the metallographic polishing R\&D program covering Niobium and Copper substrates treatment for thin film coating as an alternative fabrication pathway for 1.3 GHz elliptical cavities. The presented research is the result of a collaborative effort between IJCLab, CEA/Irfu, HZB, and KEK in order to develop innovative surface processing and cavity fabrication protocols capable of meeting stringent requirements for SRF surfaces, including the reduction of safety risks and ecological footprint, enhancing reliability, improving the surface roughness, and potentially allowing cost reduction. The research findings will be disclosed.

Hryhorenko, O.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Dark Matter and other BSM searches with SRF cavities at SQMS

The Superconducting Quantum Materials and Systems Center, led by Fermi National Accelerator Laboratory, is one of five research centers funded by the U.S. Department of Energy as part of a national initiative to develop and deploy the world’s most powerful quantum computers and sensors. The SQMS Center uses world-record quality-factor superconducting radio-frequency, or SRF, cavities as ultra-sensitive quantum probes. Cavities combined with superconducting transmon qubits can be the building block of a quantum computer, and they can also be employed for fundamental physics searches. Within the quantum sensing thrust, researchers are developing experiments based on cavities and novel quantum devices to search for particles beyond the Standard Model, dark matter candidates, gravitational waves and fundamental material properties. The seminar will present a brief overview of the center and focus on the physics and sensing work conducted at Fermilab.

43 PARTICLE ACCELERATORS↗