Superconducting penetration depth through a Van Hove singularity: Sr 2 ⁢RuO 4 under uniaxial stress

A plethora of experiments in Sr 2 RuO 4 have reached conflicting conclusions about the symmetry of the superconducting gap. To probe the gap’s structure in k-space, we use strain to continuously tune the band structure through a Van Hove singularity (VHS) while imaging the superconductivity with scanning SQUID microscopy. We find that the superfluid density peaks at the VHS and that the temperature dependence of the penetration depth is T 2 -quadratic over the entire measured range of strain ε. These results are consistent with a gap structure that has vertical line nodes, experimentally confirming that non-local effects in the Meissner screening can lead to T 2 behavior and clarifying the nature of the low-energy excitations in Sr 2 RuO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion permeation in potassium ion channels

The study of ion channels dates back to the 1950s and the groundbreaking electrophysiology work of Hodgin and Huxley, who used giant squid axons to probe how action potentials in neurons were initiated and propagated. More recently, several experiments using different structural biology techniques and approaches have been conducted to try to understand how potassium ions permeate through the selectivity filter of potassium ion channels. Two mechanisms of permeation have been proposed, and each of the two mechanisms is supported by different experiments. The key structural biology experiments conducted so far to try to understand how ion permeation takes place in potassium ion channels are reviewed and discussed. Protein crystallo­graphy has made, and continues to make, key contributions in this field, often through the use of anomalous scattering. Other structural biology techniques used to study the contents of the selectivity filter include solid-state nuclear magnetic resonance and two-dimensional infrared spectroscopy, both of which make clever use of isotopic labeling techniques, while molecular-dynamics simulations of ion flow through the selectivity filter have been enabled by the growing number of potassium ion channel structures deposited in the Protein Data Bank.

59 BASIC BIOLOGICAL SCIENCES↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data for Magnetic Anisotropy due to Localized Structural Defects in Strained Yttrium Iron Garnet Thin Films

This dataset contains electron microscopy, magnetic, and X-ray diffraction characterization data for YIG/YSGG thin films associated with the manuscript "Magnetic anisotropy due to localized structural defects in strained yttrium iron garnet thin films". Characterizations include: scanning electron nano diffraction (SEND, or 4D-STEM), dark field transmission electron microscopy (DF-TEM), energy dispersive X-ray spectroscopy (EDS), ferrimagnetic resonance (FMR), superconducting quantum interference device (SQUID), scanning transmission electron microscopy (STEM), X-ray diffraction (XRD).

Electron microscopy↗

Synthesis and behavior of bulk iron nitride soft magnets via high-pressure spark plasma sintering

Abstract In this study, dense bulk iron nitrides (Fe x N) were synthesized for the first time ever using spark plasma sintering (SPS) of Fe x N powders. The Fe 4 N phase of iron nitride in particular has significant potential to serve as a new soft magnetic material in both transformer and inductor cores and electrical machines. The density of SPSed Fe x N increased with SPS temperature and pressure. The microstructure of the consolidated bulk Fe x N was characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and superconducting quantum interference device (SQUID) magnetometry. XRD revealed a primary phase of Fe 4 N with secondary phases of Fe 3 N and metallic iron. Finite element analysis (FEA) was also applied to investigate and explain localized heating and temperature distribution during SPS. The effects of processing on interface bonding formation and phase evolution were investigated and discussed in detail to provide insight into fundamental phenomena and microstructural evolution in SPSed Fe x N. Graphic abstract

36 MATERIALS SCIENCE↗

Quantum Sensing and its Potential for Nuclear Safeguards

Quantum sensing has the potential to provide ultrasensitive measurements of physical phenomenon. Unlike quantum computing, quantum sensing is available now, though in general at research laboratories. A notable commercially-available quantum sensing device is the ubiquitous Superconducting Quantum Interference Device (SQUID), which can measure faint magnetic fields such as found in the human brain. Quantum sensing is used for direct measurement of environmental phenomenon, such as electromagnetic fields and accelerations, which then are used for certain applications. For example, quantum sensing of accelerations is useful for Position, Navigation, and Timing (PNT) applications. It is not clear, however, how quantum sensing can be useful for nuclear safeguards. This report provides first a background in quantum sensing, followed by a survey of potential safeguards utilizations of quantum sensing. Several potential safeguards applications are identified and explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

Nanofabrication techniques of Josephson junction for transmon qubit

This report deals with the theory of transmon qubits in general, also focusing on the SQUID and the functioning of a Josephson junction. The interaction of the qubit in a cavity with the quantized electro-magnetic field is then treated. After this introduction whose goal is to contextualize the work that I actually did, I will talk about the 2D and 3D qubits that we have built. The problem of etching and "patching" will be dealt with in detail, reporting the results obtained in the laboratory. Finally, I wanted to conclude by addressing the concept of measurement of a qubit in a cavity only at a theoretical level. I conclude everything with a "Feynman treatment" of the cavities which in my opinion is really very interesting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of critical scaling in spin glasses below T c using thermoremanent magnetization

Time-dependent thermoremanent magnetization (TRM) studies have been instrumental in probing energy dynamics within the spin glass phase. In this paper, we review the evolution of the TRM experiment over the last half century and discuss some aspects related to how it has been used in the understanding of spin glasses. We also report on recent experiments using high-resolution DC SQUID magnetometry to probe the TRM at temperatures less than but near to the transition temperature T c . These experiments have been performed as a function of waiting time, temperature, and five different magnetic fields. We find that as the transition temperature is approached from below, the characteristic time scale of TRM is suppressed up to several orders of magnitude in time. In the highest-temperature region, we find that the waiting time effect subsides, and a waiting time-independent crossover line is reached. We also find that increasing the magnetic field further suppresses the crossover line. Using a first-principles energy argument across the crossover line, we derive an equation that is an excellent fit to the crossover lines for all magnetic fields probed. The data show strong evidence for critical slowing down and an H = 0 Oe phase transition.

36 MATERIALS SCIENCE↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

Magnetic Compton Scattering Study of Li-Rich Battery Materials

The redox process in a lithium-ion battery occurs when a conduction electron from the lithium anode is transferred to the redox orbital of the cathode. Understanding the nature of orbitals involved in anionic as well as cationic redox reactions is important for improving the capacity and energy density of Li-ion batteries. In this connection, we have obtained magnetic Compton profiles (MCPs) from the Li-rich cation-disordered rock-salt compound LixTi0.4Mn0.4O2 (LTMO). The MCPs, which involved the scattering of circularly polarized hard X-rays, are given by the momentum density of all the unpaired spins in the material. The net magnetic moment in the ground state can be extracted from the area under the MCP, along with a SQUID measurement. Our analysis gives insight into the role of Mn 3d magnetic electrons and O 2p holes in the magnetic redox properties of LTMO.

Suzuki, Kosuke (ORCID:0000000317110604)↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

The biology of cartilage. II

Squid head cartilage properties in terms of light and electron microscopic appearance, amino acid composition and X ray diffraction

Person, P.↗

The effect of membrane parameters on the properties of the nerve impulse.

The effect of varying some membrane parameters is explored, basing the investigation on computer simulation of the Hodgkin-Huxley equations for the squid giant axon, including variations in the membrane capacitance, conductances, and the rate constants. It is shown that by reducing the degree of regeneration in the excitable membrane, the character of the nerve signal can be smoothly changed from that of the axonal spike to essentially electrotonic spread, with all gradations in between. The reduction in the degree of regeneration can most simply be brought about by a decrease in the density of active membrane patches.

Sabah, N. H.↗

Improvements of a magnetic monopole detector

Modifications to our previously described detector of magnetic monopoles resulting in substantial improvements in performance have been made. The sensitivity has been increased a factor of 35 by using a sensitive magnetometer (SQUID) to measure changes in current. The modifications, new measurement techniques, and implications for past and future experiments are described.

Eberhard, P. H.↗

A high accuracy gyroscope readout test facility for the relativity gyroscope experiment

An apparatus is under construction for ground-based testing of a gyroscope system to be used in a satellite test of general relativity. The immediate goal is a readout capable of measuring the direction of the gyroscope spin axis to an angular resolution of one arcsecond over a limited range. A combination of SQUID magnetometers and persistent current loops are used to measure the London moment of the spinning superconducting rotor levitated electrostatically. To obtain a trapped flux signal in the gyroscope sufficiently smaller than the London moment signal, the apparatus makes use of a new magnetic field shielding technique for obtaining large superconductor shielded regions below 0.1 millionth of a Gauss.

Cabrera, B.↗

Superconducting bearings for application in cryogenic experiments in space

Linear superconducting magnetic bearings suitable for use in a proposed orbital equivalence principle experiment and for general application in space were developed and tested. Current flows in opposite directions in adjacent superconducting wires arranged parallel to the axis of a cylinder. This configuration provides maximum stiffness radially while allowing the test mass to move freely along the cylinder axis. In a space application, the wires are extended to cover the entire perimeter of the cylinder: for the earth-based tests it was desirable to use only the bottom half. Control of the axial position of the test mass is by small control coils which may be positioned inside or outside the main bearing. The design is suitable for application to other geometries where maximum stiffness is desired. A working model scaled to operate in a 1-g environment was perfected approximate solutions for the bearings were developed. A superconducting transformer method of charging the magnets for the bearing, and a position detector based on a SQUID magnetometer and associated superconducting circuit were also investigated.

Everitt, C. W. F.↗

Development of a London moment readout for a superconducting gyroscope

A gyroscope for verifying certain predictions of General Relativity is under development at Stanford. A method of measuring the gyroscope orientation based on the use of the London moment and a SQUID magnetometer is described. It is estimated that the required sensitivity of 1 milliarc-sec can be achieved in a bandwidth of 2.5 times 10 to the -6th Hz.