Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTRAL SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electrooptical effect in the plasmon structure glass–In{sub 2}O{sub 3}: Sn–ferroelectric–Al with a subwavelength grating

The spectral features of the electrooptical effect, in which an applied voltage changes the refractive index of a ferroelectric copolymer, are studied. Three nanostructures are investigated: two nanostructures play an auxiliary role, and the basic structure consists of a glass substrate, a transparent ITO (In{sub 2}O{sub 3}: Sn) layer, active copolymer layer, and an Al layer with a nanograting. This grating with a period of 400 nm meets the conditions of excitation of plasmon resonances. The light transmission coefficients of all structures are analyzed in the spectral range 400–900 nm. The transmission spectra have two characteristic plasmon dips, one of which is related to the copolymer–ITO interface and the other, to the copolymer–Al interface. The aluminum and ITO layers play the role of electrodes, which supply voltage pulses (from 0 to 15 V) to the copolymer layer. When studying the electrooptical effect, we detected spectral shifts in plasmon resonance bands when the amplitudes of both positive and negative voltage pulses (quadratic effect) increase. These shifts change the effective refractive indices (n{sub eff}) of the structural elements, reaching the minimum negative increment Δ{sub eff} =–0.06.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent pulse interrogation system for fiber Bragg grating sensing of strain and pressure in dynamic extremes of materials

A 100 MHz fiber Bragg grating (FBG) interrogation system is described and applied to strain and pressure sensing. The approach relies on coherent pulse illumination of the FBG sensor with a broadband short pulse from a femtosecond modelocked erbium fiber laser. After interrogation of the FBG sensor, a long multi-kilometer run of single mode fiber is used for chromatic dispersion to temporally stretch the spectral components of the reflected pulse from the FBG sensor. Dynamic strain or pressure induced spectral shifts in the FBG sensor are detected as a pulsed time domain waveform shift after encoding by the chromatic dispersive line. Signals are recorded using a single 35 GHz photodetector and a 50 G Samples per second, 25 GHz bandwidth, digitizing oscilloscope. Application of this approach to high-speed strain sensing in magnetic materials in pulsed magnetic fields to ~150 T is demonstrated. The FBG wavelength shifts are used to study magnetic field driven magnetostriction effects in LaCoO₃. A sub-microsecond temporal shift in the FBG sensor wavelength attached to the sample under first order phase change appears as a fractional length change (strain: ΔL/L<10⁻⁴) in the material. A second application used FBG sensing of pressure dynamics to nearly 2 GPa in the thermal ignition of the high explosive PBX-9501 is also demonstrated. Both applications demonstrate the use of this FBG interrogation system in dynamical extreme conditions that would otherwise not be possible using traditional FBG interrogation approaches that are deemed too slow to resolve such events.

36 MATERIALS SCIENCE↗

Demonstration of the DC-Kerr effect in silicon-rich nitride

We demonstrate the DC-Kerr effect in plasma enhanced chemical vapor deposition (PECVD) silicon-rich nitride (SRN) and use it to demonstrate a third order nonlinear susceptibility, χ (3) , as high as (6 ± 0.58) × 10 -19 m 2 /V 2 . We employ spectral shift versus applied voltage measurements in a racetrack resonator as a tool to characterize the nonlinear susceptibilities of these films. In doing so, we demonstrate a χ (3) larger than that of silicon and argue that PECVD SRN can provide a versatile platform for employing optical phase shifters while maintaining a low thermal budget using a deposition technique readily available in CMOS process flows.

42 ENGINEERING↗

Luminescent Lanthanide Reporters for High-Sensitivity Novel Bioassays

Biological imaging and assay technologies rely on fluorescent organic dyes as reporters for a number of interesting targets and processes. However, limitations of organic dyes such as small Stokes shifts, spectral overlap of emission signals with native biological fluorescence background, and photobleaching have all inhibited the development of highly sensitive assays. To overcome the limitations of organic dyes for bioassays, we propose to develop lanthanide-based luminescent dyes and demonstrate them for molecular reporting applications. This relatively new family of dyes was selected for their attractive spectral and chemical properties. Luminescence is imparted by the lanthanide atom and allows for relatively simple chemical structures that can be tailored to the application. The photophysical properties offer unique features such as narrow and non-overlapping emission bands, long luminescent lifetimes, and long wavelength emission, which enable significant sensitivity improvements over organic dyes through spectral and temporal gating of the luminescent signal.Growth in this field has been hindered due to the necessary advanced synthetic chemistry techniques and access to experts in biological assay development. Our strategy for the development of a new lanthanide-based fluorescent reporter system is based on chelation of the lanthanide metal center using absorbing chromophores. Our first strategy involves "Click" chemistry to develop 3-fold symmetric chelators and the other involves use of a new class of tetrapyrrole ligands called corroles. This two-pronged approach is geared towards the optimization of chromophores to enhance light output.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗

Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out [Slides]

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Applying Two-Dimensional Correlation Spectroscopy and Principal Component Analysis to Understand How Temperature Affects the Neptunium(V) Absorption Spectrum

The visible-near infrared (Vis-NIR) electronic absorption spectrum of neptunium(V) (NpO 2 + ) comprises numerous f-f electronic transitions with mostly undocumented temperature dependencies. The effect of temperature on the absorption spectrum of the pentavalent neptunyl dioxocation (NpO 2 + ) is an important factor to consider with spectrophotometric applications but has often been overlooked. Optical Vis-NIR absorption spectra (400–1700 nm) of Np(V) (0.017–0.89 M) in 1 M nitric acid were evaluated with varying temperatures (T = 10–80 °C). The intensity, position, and overall shape of the bands were sensitive to interactions with the solvent and coordination environment. Numerous temperature-induced isosbestic points were identified resulting from dynamic, overlapping peak shifts. Spectral variations were characterized using principal component analysis (PCA) and 2D correlation spectroscopy (COS). 2D-COS revealed that the absorption band near 1095 nm likely consists of two bands centered near 1087 and 1096 nm, which cannot be explained by current computational methods. 2D-COS analysis also provided an unambiguous assignment of unresolved peaks in the visible region for comparison with computational predictions. PCA was used to identify nonlinearity in the spectral response at elevated Np(V) concentrations ≥ 0.5 M. This unique experimental data and interpretation will foster a deeper understanding of the absorption spectra for complex actinyl ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Three-dimensional Expansion of the Ejecta from Tycho's Supernova Remnant

We present the first 3D measurements of the velocity of various ejecta knots in Tycho’s supernova remnant, known to result from a Type Ia explosion. Chandra X-ray observations over a 12 yr baseline from 2003 to 2015 allow us to measure the proper motion of nearly 60 “tufts” of Si-rich ejecta, giving us the velocity in the plane of the sky. For the line-of-sight velocity, we use two different methods: a nonequilibrium ionization model fit to the strong Si and S lines in the 1.2–2.8 keV regime, and a fit consisting of a series of Gaussian lines. These methods give consistent results, allowing us to determine the redshift or blueshift of each of the knots. Assuming a distance of 3.5 kpc, we find total velocities that range from 2400 to 6600 km s{sup −1}, with a mean of 4430 km s{sup −1}. We find several regions where the ejecta knots have overtaken the forward shock. These regions have proper motions in excess of 6000 km s{sup −1}. Some SN Ia explosion models predict a velocity asymmetry in the ejecta. We find no such velocity asymmetries in Tycho, and we discuss our findings in light of various explosion models, favoring those delayed-detonation models with relatively vigorous and symmetrical deflagrations. Finally, we compare measurements with models of the remnant’s evolution that include both smooth and clumpy ejecta profiles, finding that both ejecta profiles can be accommodated by the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Multichannel analyzers at high rates of input

Multichannel analyzer, used with a gating system incorporating pole-zero compensation, pile-up rejection, and baseline-restoration, achieves good resolution at high rates of input. It improves resolution, reduces tailing and rate-contributed continuum, and eliminates spectral shift.

Rudnick, S. J.↗

Design and flight performance evaluation of the Mariners 6, 7, and 9 short-circuit current, open-circuit voltage transducers

The purpose of the short-circuit voltage transducer is to provide engineering data to aid the evaluation of array performance during flight. The design, fabrication, calibration, and in-flight performance of the transducers onboard the Mariner 6, 7 and 9 spacecrafts are described. No significant differences were observed in the in-flight electrical performance of the three transducers. The transducers did experience significant losses due to coverslides or adhesive darkening, increased surface reflection, or spectral shifts within coverslide assembly. Mariner 6, 7 and 9 transducers showed non-cell current degradations of 3-1/2%, 3%, and 4%, respectively at Mars encounter and 6%, 3%, and 4-12%, respectively at end of mission. Mariner 9 solar Array Test 2 showed 3-12% current degradation while the transducer showed 4-12% degradation.

Patterson, R. E.↗

Optimal use of electrophysiological indicators of muscular effort and fatigue

Electromyograms (EMG) from working muscles convey information on effort and fatigue. Their application, e.g., to assess the demands of vehicle control tasks, is complicated by the cooperative action of sets of muscles, by both intrinsic and imposed filtering, and by numerous other sources of variation. Fourier analyses of these noise like signals offer one approach to interpretation; downward spectral shifts accompany fatigue. Techniques are being sought (in both time and frequency domains) for further condensing the wideband EMG signals, while retaining essential information, into a concise 'state vector' usable in comparing control system designs.

Updike, O. L.↗

Evidence that Resorption of Bone by Rat Peritoneal Macrophages Occurs in an Acidic Environment

Skeletal loss in space, like any form of osteoporosis, reflects a relative imbalance of the activities of cells resorbing (degrading) or forming bone. Consequently, prevention of weightlessness induced bone loss may theoretically be accomplished by (1) stimulating bone formation or (2) inhibiting bone resorption. This approach, however, requires fundamental understanding of the mechanisms by which cells form or degrade bone, information not yet at hand. An issue central to bone resorption is the pH at which resorption takes place. The pH dependent spectral shift of a fluorescent dye (fluorescein isothiocyanate) conjugated to bone matrix was used to determine the pH at the resorptive cell bone matrix interface. Devitalized rat bone was used as the substrate, and rat peritoneal macrophages were used as the bone resorbing cells. The results suggest that bone resorption is the result of generation of an acidic microenvironment at the cell matrix junction.

Blair, H. C.↗

SUMER: Solar Ultraviolet Measurements of Emitted Radiation

The SUMER (solar ultraviolet measurements of emitted radiation) experiment is described. It will study flows, turbulent motions, waves, temperatures and densities of the plasma in the upper atmosphere of the Sun. Structures and events associated with solar magnetic activity will be observed on various spatial and temporal scales. This will contribute to the understanding of coronal heating processes and the solar wind expansion. The instrument will take images of the Sun in EUV (extreme ultra violet) light with high resolution in space, wavelength and time. The spatial resolution and spectral resolving power of the instrument are described. Spectral shifts can be determined with subpixel accuracy. The wavelength range extends from 500 to 1600 angstroms. The integration time can be as short as one second. Line profiles, shifts and broadenings are studied. Ratios of temperature and density sensitive EUV emission lines are established.

Wilhelm, K.↗

Data acquisition and processing

Fundamental methods of signal processing used in normal mesosphere stratosphere troposphere (MST) radar observations are described. Complex time series of received signals obtained in each range gate are converted into Doppler spectra, from which the mean Doppler shift, spectral width and signal-to-noise ratio (SNR) are estimated. These spectral parameters are further utilized to study characteristics of scatterers and atmospheric motions.

Tsuda, Toshitaka↗

CW laser strategies for multi-parameter measurements of high-speed flows containing either NO or O2

Measurements of gasdynamic quantities were performed using a rapid-tuning CW dye laser to resolve Doppler-shifted spectral features in either the O2 Schumann-Runge bands or the NO gamma band near 225 nm. With the rapid-tuning capability, spectral features were acquired at a repetition rate of 4 kHz. Monitoring O2 transitions provided estimates of velocities while monitoring collision-broadened NO line pairs provided simultaneous measurements of velocity, temperature and pressure. Experiments were first performed in absorption within the transient one-dimensional flows generated in a shock tube. Agreement between measured and theoretical values, as calculated from one-dimensional shock relations, was typically better than 5 percent. The method was extended to fluorescence detection of NO in a static cell. Temperature and pressure were extracted from recorded profiles, and the results agreed well with expected values.

Dirosa, M. D.↗