Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance of the H- Ion Source Supporting 1-MW Beam Operations at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached 1-MW of beam power in September 2009, and now routinely operates near 1-MW for the production of neutrons. This paper reviews the performance, operational issues, implemented and planned mitigations of the SNS H- ion source to support such high power-level beams with high availability. Some results from R&D activities are also briefly described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNS second target station moderator performance update

In its first years of operations of its first target station, the Spallation Neutron Source (SNS) is working towards a facility upgrade by a megawatt-class second target station operated at 20 Hz repetition rate, which is intended to complement the existing ORNL neutron sources, the first SNS target station and the HFIR reactor, with high-intensity cold neutron beams.The first round of optimization calculations converged on larger-volume cylindrical para-hydrogen moderators placed in wing configuration on top and bottom of a flat mercury target, pre-moderated by layers of ambient water and surrounded by beryllium reflector. The metric of these optimization calculations was time-averaged and energy-integrated neutron brightness below 5 meV with the requirement to be able to serve 20 ports with neutrons. A summary of these calculations will be given including lessons learned from the variety of simulated configurations and detailed neutron performance characteristics like spectral intensities, emission time distributions, local variations of moderator brightness at the viewed areas, and sensitivity of the optimization metric to optimized parameters for the most promising configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNS target reaches end-of-life

On Sunday, April 3, 2011, the Spallation Neutron Source (SNS) target reached an end-of-life condition, so user operations were shut down to change the stainless steel target housing the liquid mercury. This is the third change out of the target vessel; it is an expected event and took about two weeks. We took advantage of this time to do maintenance work that was planned for the longer summer shutdown. This will shorten that shutdown and recover the neutron production time. SNS restarted user operations on April 20.

36 MATERIALS SCIENCE↗

SNS LINAC MODULATOR OPERATIONAL HISTORY AND PERFOMANCE

Fourteen High Voltage Converter Modulators (HVCM) were initially installed at the Spallation Neutron Source Linear Accelerator (SNS Linac) at the Oak Ridge National Laboratory in 2005. A fifteenth HVCM was added in 2009. Each modulator provides a pulse of up to 140 kV at a maximum width of 1.35 msec. Peak power level is 11 MW with an 8% duty factor. The HVCM system must be available for neutron production (NP) 24/7 with the exception being two, 6-week maintenance periods per year. HVCM reliability is one of the most important factors to maximize Linac availability and achieve SNS performance goals. During the last few years several modifications have been implemented to improve the overall system reliability. This paper presents operational history of the HVCM systems and examines failure mode statistical data since the modulators began operating at 60 Hz. System enhancements and upgrades aimed at providing long term reliable operation with minimal down time are also discussed in the paper.

43 PARTICLE ACCELERATORS↗

A Quest for Measuring Ion Bunch Longitudinal Profiles with One Picosecond Accuracy in the SNS Linac.

The SNS linac utilizes several accelerating structures operating at different frequencies and with different transverse focusing structures. Low-loss beam transport requires a careful matching at the transition points in both the transverse and longitudinal axes. Longitudinal beam parameters are measured using four Bunch Shape Monitors (used at many ion accelerator facilities, aka Feschenko devices). These devices, as initially delivered to the SNS, provided an estimated accuracy of about 5 picoseconds, which was sufficient for the initial beam commissioning. New challenges of improving beam transport for higher power operation will require measuring bunch profiles with 1-2 picoseconds accuracy. We have successfully implemented a number of improvements to maximize the performance characteristics of the delivered devices. We will discuss the current status of this instrument, its ultimate theoretical limit of accuracy, and how we measure its accuracy and resolution with real beam conditions.

43 PARTICLE ACCELERATORS↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF Distribution System for High Power Test of the SNS Cryomodule

A four-way waveguide RF power distribution system for testing the Spallation Neutron Source (SNS) multi-cavity cryomodule to investigate the collective behavior has been developed. A single klystron operating at 805MHz for 1.3 msec at 60Hz powers the 4-way waveguide splitter to deliver up to 400 kW to individual cavities. Each cavity is fed through a combination of waveguide splitters and vector modulators (VM) to provide independent magnitude and phase controls. The waveguide vector modulator consists of two quadrature hybrids and two motorized waveguide phase shifters. The phase shifters and the assembled waveguide vector modulators were individually tested and characterized for low power and high RF power in the SNS RF test facility. Precise calibrations of magnitude and phase were performed to generate the look up tables (LUTs) to provide operational references during the cryomodule test. An I-Q demodulator module was developed and utilized to measure relative phases in pulsed high RF power operation. PLC units were developed for mechanical control of the phase shifters. Initial low/high power measurements were made using LabVIEW. An operation algorithm has been implemented into EPICS control for the cryomodule test stand.

43 PARTICLE ACCELERATORS↗

Tracking Stripped Proton Particles in SNS Ring Injection Momentum Dump Line

3D computer simulations are performed to study magnetic field distributions and particle trajectories along the SNS ring injection momentum dump line. Optical properties and transfer maps along the dump line are calculated. The stripped proton particle distributions on the dump window are analyzed. The study has provided useful information for the redesign of the SNS ring injection beam dump.

43 PARTICLE ACCELERATORS↗

Producing Persistent, High-Current, High-Duty-Factor H- Beams for Routine 1 MW Operation of SNS

Since 2009, SNS has been producing neutrons with ion beam powers near 1 MW, which requires the extraction of ~50 mA H- ions from the ion source with a ~5% duty factor. The 50 mA are achieved after an initial dose of ~3 mg of Cs and heating the Cs collar to ~170 C. The 50 mA normally persist for the entire 4-week source service cycles. Fundamental processes are reviewed to elucidate the persistence of the SNS H- beams without a steady feed of Cs and why the Cs collar temperature may have to be kept near 170 C.

Cesium↗

SNS BLM SYSTEM EVOLUTION: DETECTORS, ELECTRONICS AND SOFTWARE

SNS is a high intensity hadron beam facility; so the Beam Loss Monitor (BLM) system is a crucial part of Machine Protection System and an important tool for beam tuning. The paper presents the current status of installed detectors and experimental data obtained during SNS operations. We compare several different types of BLMs and show advantages and disadvantages of each type. The electronic parts obsolescence became a real issue since the original electronics was designed about 10 years ago. The first test of our next generation BLM system is expected to be done by summer 2009. The new system will contribute to significant noise reduction and will follow a modular concept of Smart Device to achieve a higher degree of reliability and maintainability.

Zhukov, Alexander P↗

IGBT Gate Driver Upgrades to the HVCM at the SNS

The SNS at ORNL has been fully operational since 2006 and in September 2009, the design goal of 1MW of sustained beam power on target was achieved. Historically, the high voltage converter modulators (HVCM) have been a known problem area and, in order to reach another SNS milestone of 90% availability, a new gate driver was one of several areas targeted to improve the overall reliability of the HVCM systems. The drive capability and fault protection of the large IGBT modules in the HVCM were specifically addressed to improve IGBT switching characteristics and provide enhanced troubleshooting and monitoring capabilities for the critical IGBT/driver pair. This paper outlines the work involved; the result obtained and documents the driver s long-term performance. Enhanced features, designed to be used in conjunction with a new controller presently under development, will also be discussed.

IGBT gate driver↗

STATUS OF LASER STRIPPING AT THE SNS

This paper presents an overview of experimental and theoretical studies on laser stripping that have been conducted up to the present time in the SNS project. The goal of this work is to develop techniques to achieve the experimental preconditions necessary for the successful realization of a future intermediate experiment on laser stripping. The experimental work consists of the tuning and measurement of H beam parameters in readiness for the intermediate experiment, and also takes into account the features and possibilities of the SNS accelerator.

Gorlov, Timofey V↗

LONGITUDINAL TUNING OF THE SNS SUPERCONDUCTING LINAC

The SNS superconducting linac delivers about 1 GeV of energy driven by self-consistent RF cavities. Here, we present an experience of the longitudinal tune-up of the SNS linac where a new application for quick RF phase setup and cavity fault adaptation was created. The routine of superconducting linac tune-up, longitudinal beam manipulation, and radio frequency cavity phase scaling for beam state recovery is presented. The application has direct value for beam optics study and will serve as the basis for longitudinal beam-size manipulation for the laser stripping project.

Gorlov, Timofey V↗

SIMULATION AND MOCKUP OF SNS JET-FLOW TARGET WITH WALL JET FOR CAVITATION DAMAGE MITIGATION

Pressure waves created in liquid mercury pulsed spallation targets at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory induce cavitation damage on the stainless steel target container. The cavitation damage is thought to limit the lifetime of the target for power levels at and above 1 MW. Severe through-wall cavitation damage on an internal wall near the beam entrance window has been observed in spent-targets. Surprisingly though, there is very little damage on the walls that bound an annular mercury channel that wraps around the front and outside of the target. The mercury flow through this channel is characterized by smooth, attached streamlines. One theory to explain this lack of damage is that the uni-directional flow biases the direction of the collapsing cavitation bubble, reducing the impact pressure and subsequent damage. The theory has been reinforced by in-beam separate effects data. For this reason, a second-generation SNS mercury target has been designed with an internal wall jet configuration intended to protect the concave wall where damage has been observed. The wall jet mimics the annular flow channel streamlines, but since the jet is bounded on only one side, the momentum is gradually diffused by the bulk flow interactions as it progresses around the cicular path of the target nose. Numerical simulations of the flow through this jet-flow target have been completed, and a water loop has been assembled with a transparent test target in order to visualize and measure the flow field. This paper presents the wall jet simulation results, as well as early experimental data from the test loop.

cavitation mercury target jet flow wall jet↗

Evaluation of SNS Beamline Shielding Configurations using MCNPX Accelerated by ADVANTG

Shielding analyses for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pose significant computational challenges, including highly anisotropic high-energy sources, a combination of deep penetration shielding and an unshielded beamline, and a desire to obtain well-converged nearly global solutions for mapping of predicted radiation fields. The majority of these analyses have been performed using MCNPX with manually generated variance reduction parameters (source biasing and cell-based splitting and Russian roulette) that were largely based on the analyst's insight into the problem specifics. Development of the variance reduction parameters required extensive analyst time, and was often tailored to specific portions of the model phase space. We previously applied a developmental version of the ADVANTG code to an SNS beamline study to perform a hybrid deterministic/Monte Carlo analysis and showed that we could obtain nearly global Monte Carlo solutions with essentially uniform relative errors for mesh tallies that cover extensive portions of the model with typical voxel spacing of a few centimeters. The use of weight window maps and consistent biased sources produced using the FW-CADIS methodology in ADVANTG allowed us to obtain these solutions using substantially less computer time than the previous cell-based splitting approach. While those results were promising, the process of using the developmental version of ADVANTG was somewhat laborious, requiring user-developed Python scripts to drive much of the analysis sequence. In addition, limitations imposed by the size of weight-window files in MCNPX necessitated the use of relatively coarse spatial and energy discretization for the deterministic Denovo calculations that we used to generate the variance reduction parameters. We recently applied the production version of ADVANTG to this beamline analysis, which substantially streamlined the analysis process. We also tested importance function collapsing (in space and energy) capabilities in ADVANTG. These changes, along with the support for parallel Denovo calculations using the current version of ADVANTG, give us the capability to improve the fidelity of the deterministic portion of the hybrid analysis sequence, obtain improved weight-window maps, and reduce both the analyst and computational time required for the analysis process.

43 PARTICLE ACCELERATORS↗

MODEL BENCHMARK WITH EXPERIMENT AT THE SNS LINAC

The history of attempts to perform a transverse match-ing in the Spallation Neutron Source (SNS) superconduct-ing linac (SCL) is discussed. The SCL has 9 laser wire (LW) stations to perform non-destructive measurements of the transverse beam profiles. Any matching starts with the measurement of the initial Twiss parameters, which in the SNS case was done by using the first four LW stations at the beginning of the superconducting linac. For years the consistency between data from all LW stations could not be achieved. This problem was resolved only after significant improvements in accuracy of the phase scans of the SCL cavities, more precise analysis of all available scan data, better optics planning, and the initial longitudi-nal Twiss parameter measurements. The presented paper discusses in detail these developed procedures.

Linac model↗

Burst-Mode UV Enhancement Cavity for Laser-Assisted Hydrogen Ion Beam Stripping at SNS

Recent success of laser-assisted charge exchange for 10 μs duration Hydrogen ion beams at SNS motivates laser development necessary for efficient stripping of 1.0 ms duration beam at full duty cycle. To overcome the laser power challenge, the interaction point was chosen inside an optical cavity. A doubly-resonant enhancement cavity and a novel locking technique have been developed, and a coherent enhancement of 402.5 MHz, 50 ps, 1.05 MW peak power ultraviolet (355 nm) laser pulses operating at 10-μs/10-Hz burst mode has been demonstrated. This will enable 1.0 ms duration laser macropulses at 60 Hz to be stored inside such a cavity to achieve efficient stripping at SNS.

Oguz, Abdurahim↗