Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution using rice husk-based activated carbon

An attempt was made to investigate the potential of rice husk-based activated carbon as an alternative low-cost adsorbent for the removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Rice husk-based activated carbon was prepared via treatment of rice husk with NaOH followed by the carbonization process at 400°C for 2 hours. Three samples, i.e. raw rice husk, rice husk treated with NaOH and rice husk-based activated carbon, were analyzed for their morphological characteristics using field-emission scanning electron microscope/energy dispersive X-ray (FESEM/EDX). These samples were also analyzed for their carbon, hydrogen, nitrogen, oxygen and silica contents using CHN elemental analyzer and FESEM/EDX. The porous properties of rice husk-based activated carbon were determined by Brunauer-Emmett-Teller (BET) surface area analyzer, and its surface area and pore volume were 255 m{sup 2}/g and 0.17 cm{sup 2}/g, respectively. The adsorption studies for the removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution were carried out at a fixed initial concentration of metal ion (150 ppm) with variation amount of adsorbent (rice husk-based activated carbon) as a function of varied contact time at room temperature. The concentration of each metal ion was analyzed using atomic absorption spectrophotometer (AAS). The results obtained from adsorption studies indicate the potential of rice husk as an economically promising precursor for the preparation of activated carbon for removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Isotherm and kinetic model analyses suggested that the experimental data of adsorption studies fitted well with Langmuir, Freundlich and second-order kinetic models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin Dynamics of a Single Mn Ion in a CdTe/(Cd, Mg, Zn)Te Quantum Dot

The spin dynamics of a single Mn ion confined in a CdTe/(Cd, Mg, Zn)Te quantum dot is determined by measurements of photon correlation of photoluminescence. The characteristic time of spin flip is a few nanoseconds and strongly depends on the excitation power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parity-relevant zitterbewegung and quantum simulation by a single trapped ion

Zitterbewegung (ZB), the trembling of free relativistic electrons in a vacuum, could be simulated by a single trapped ion. We focus on the variations of ZB under different parity conditions and find no ZB in the case of odd or even parity. ZB occurs only for the admixture of the odd- and even-parity states. We also show that a similar role is played by the parity operator for the trapped ion in Fock-state representation and the space-inversion operator for a realistic relativistic electron. Although the ZB effect is invisible in a relativistic electron, preparation of the trapped ion in different parity states is a sophisticated job, which makes it possible to observe the parity-relevant ZB effects with currently available techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semi-empirical scaling for ion–atom single charge exchange cross sections in the intermediate velocity regime

We present a semi-empirical scaling law for non-resonant ion–atom single charge exchange cross sections for collisions with velocities from ${10}^{7}\,{\rm{t}}{\rm{o}}\,{10}^{9}\,\mathrm{cm}\,{{\rm{s}}}^{-1}$ and ions with positive charge $q\lt 8$. Non-resonant cross sections tend to have a velocity peak at collision velocities $v\lesssim 1\ {\rm{a}}{\rm{u}}$ with exponential decay around this peak. We construct a scaling formula for the location of this peak then choose a functional form for the cross section curve and scale it. The velocity at which the cross section peaks, v m , is proportional to the energy defect of the collision, ${\rm{\Delta }}E$, which we predict with the decay approximation. The value of the cross section maximum is proportional to the charge state q, inversely proportional to the target ionization energy I T , and inversely proportional to v m . For the shape of the cross section curve, we use a function that decays exponentially asymptotically at high and low velocities. We scale this function with parameters ${v}_{{\rm{m}}},{I}_{{\rm{T}}},{Z}_{{\rm{T}}},\mathrm{and}\ {Z}_{{\rm{P}}}$, where the ${Z}_{{\rm{T}},{\rm{P}}}$ are the target and projectile atomic numbers. In conclusion, for the more than 100 cross section curves that we use to find the scaling rules, the scaling law predicts cross sections within a little over a factor of 2 on average.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electroweak Nuclear Properties from Single Molecular Ions in a Penning Trap

Here, we present a novel technique to probe electroweak nuclear properties by measuring parity violation (PV) in single molecular ions in a Penning trap. The trap’s strong magnetic field Zeeman shifts opposite-parity rotational and hyperfine molecular states into near degeneracy. The weak interaction-induced mixing between these degenerate states can be larger than in atoms by more than 12 orders of magnitude, thereby vastly amplifying PV effects. The single molecule sensitivity would be suitable for applications to nuclei across the nuclear chart, including rare and unstable nuclei.

electronic structure of atoms & molecules↗

Real-Time Analysis and Signal Optimization for Charge Detection Mass Spectrometry

Charge detection mass spectrometry (CDMS) is an important tool for measuring mass distributions for high mass samples and heterogeneous mixtures. In CDMS, single ions are trapped and their m/z and charge are measured simultaneously. As a single particle technique, the average signal must be optimized to maximize the number of single ion trapping events. If the average signal is too small, most of the trapping events will be empty, and if the average signal is too large, most of the trapping events will contain multiple ions. In recent embodiments, the time domain signal from the trapped ion is analyzed by fast Fourier transforms. The analysis time is much longer that the data collection time which precludes real-time optimization of the experimental conditions. In this paper, we describe the implementation of CDMS with real-time analysis. Processing the data in real time allows the average signal intensities to be dynamically optimized to maximize the number of single ion trapping events. Real-time analysis also allows the experimental settings to be optimized in a timely manner to target specific mass regimes to maximize the useful information content of the measurements. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond laser generated plasma as a source of singly charged ions for external injection into an EBIS

The focus of this paper is on practical aspects of ion generation by picosecond lasers as a source of low charge state ions for external injection of ions into an electron beam ion source (EBIS). For a ps-laser, compared to a ns-laser currently used at Relativistic Heavy Ion Collier Electron Beam Ion Source (RHIC EBIS), the influence of heat conductivity in the solid target is almost negligible, which results in a lower target consumption rate and less vacuum pressure rise. By using a laser with high repetition rate, it is possible to produce quasi continuous 1+ ion beams for periods of tens of milliseconds, making it possible to take advantage of the ability of the EBIS to accumulate ions in the “slow” injection capture mode. Producing such an ion pulse train is now feasible since ps-lasers with pulse energy up to 10 mJ and rep-rate up to 10 kHz have recently become commercially available. The advantages of this lower current accumulation scheme include: (1) easier beam transport due to lower space charge of lower beam currents required compared to the present single pulse fast injection scheme, (2) better EBIS pulse to pulse ion output stability since pulse to pulse ion variations of the laser source are averaged over a long train of laser pulses, and (3) the possible addition of an isotope separator in which rare beams could be produced and selected at run time from less expensive (unenriched) targets. We studied the properties of plasmas generated by a ps-laser with 1.27 mJ energy within an 8 ps pulse and a repetition rate up to 400 Hz at Argonne National Laboratory to investigate feasibility and specify parameters for a laser ion source for RHIC EBIS using a “slow” injection mode. Al, Ti, Cu, Nb, and Ta targets were tested with various target translation speeds. Here, we demonstrated that a both “slow” and “fast” injection modes are accessible with a single ion source geometry and single injection line, providing the most attractive option for an ion source for external injection into RHIC EBIS trap based on a ps-laser.

43 PARTICLE ACCELERATORS↗

Electronic stopping powers for heavy ions in SiC and SiO{sub 2}

Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC and SiO{sub 2}, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15 MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atom probe tomography characterization of ion and neutron irradiated Alloy 800H

Alloy 800H is a high temperature and creep resistant alloy, and is considered as a candidate alloy for use in Generation IV nuclear reactor systems. To clarify the alloy's behavior under irradiation, samples were subjected to single ion irradiations up to 20 dpa at 440°C, a dual ion/He irradiation to 17 dpa at 460°C, and a neutron irradiation to 17 dpa at 385°C. The irradiated microstructures were characterized using atom probe tomography to complement previously published transmission electron microscopy studies. Additionally, after single ion irradiation, sparse fine Al and Ti clusters were observed after 1dpa, while high number densities of nanoscale Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops developed after 10 and 20 dpa. The microstructure formed during single ion irradiation exhibited a strong depth dependence. No significant differences were observed between the single and dual ion irradiations. While Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops were also observed after neutron irradiation, the neutron-irradiated microstructure differed from those found in the ion-irradiated samples.

36 MATERIALS SCIENCE↗

Deterministic doping and the exploration of spin qubits

Deterministic doping by single ion implantation, the precise placement of individual dopant atoms into devices, is a path for the realization of quantum computer test structures where quantum bits (qubits) are based on electron and nuclear spins of donors or color centers. We present a donor - quantum dot type qubit architecture and discuss the use of medium and highly charged ions extracted from an Electron Beam Ion Trap/Source (EBIT/S) for deterministic doping. EBIT/S are attractive for the formation of qubit test structures due to the relatively low emittance of ion beams from an EBIT/S and due to the potential energy associated with the ions' charge state, which can aid single ion impact detection. Following ion implantation, dopant specific diffusion mechanisms during device processing affect the placement accuracy and coherence properties of donor spin qubits. For bismuth, range straggling is minimal but its relatively low solubility in silicon limits thermal budgets for the formation of qubit test structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

Broken symmetry approach to density functional calculation of zero field splittings including anisotropic exchange interactions

The broken symmetry approach to the calculation of zero field splittings (or magnetic anisotropies) of multinuclear transition metal complexes is further developed. A procedure is suggested how to extract spin Hamiltonian parameters for anisotropic exchange from a set of broken symmetry density functional calculations. For isotropic exchange coupling constants J{sub ij}, the established procedure is retrieved, and anisotropic (or pseudodipolar) exchange coupling tensors D{sub ij} are obtained analogously. This procedure only yields the sum of the individual single-ion zero field splitting tensors D{sub i}. Therefore, a procedure based on localized orbitals has been developed to extract the individual single-ion contributions. With spin Hamiltonian parameters at hand, the zero field splittings of the individual spin multiplets are calculated by an exact diagonalization of the isotropic part, followed by a spin projection done numerically. The method is applied to the binuclear cation [LCr(OH){sub 3}CrL]{sup 3+} (L = 1,4,7-trimethyl-1,4,7-triazanonane) for which experimental zero field splittings for all low-energy spin states are known, and to the single-molecule magnet [Fe{sub 4}(CH{sub 3}C(CH{sub 2}O){sub 3}){sub 2}(dpm){sub 6}] (Hdpm = 2,2,6,6-tetramethylheptane-3,5-dione). In both these 3d compounds, the single-ion tensors mainly come from the spin-orbit interaction. Anisotropic exchange is dominated by the spin-dipolar interaction only for the chromium compound. Despite the rather small isotropic exchange couplings in the iron compound, spin-orbit and spin-dipolar contributions to anisotropic exchange are of similar size here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compliant glass–polymer hybrid single ion-conducting electrolytes for lithium batteries

Despite high ionic conductivities, current inorganic solid electrolytes cannot be used in lithium batteries because of a lack of compliance and adhesion to active particles in battery electrodes as they are discharged and charged. Here, we have successfully developed a compliant, nonflammable, hybrid single ion-conducting electrolyte comprising inorganic sulfide glass particles covalently bonded to a perfluoropolyether polymer. The hybrid with 23 wt% perfluoropolyether exhibits low shear modulus relative to neat glass electrolytes, ionic conductivity of 10 -4 S/cm at room temperature, a cation transference number close to unity, and an electrochemical stability window up to 5 V relative to Li + /Li. X-ray absorption spectroscopy indicates that the hybrid electrolyte limits lithium polysulfide dissolution and is, thus, ideally suited for Li-S cells. Our work opens a previously unidentified route for developing compliant solid electrolytes that will address the challenges of lithium batteries.

25 ENERGY STORAGE↗

A generalized Jaynes-Cummings model: The relativistic parametric amplifier and a single trapped ion

We introduce a generalization of the Jaynes-Cummings model and study some of its properties. We obtain the energy spectrum and eigenfunctions of this model by using the tilting transformation and the squeezed number states of the one-dimensional harmonic oscillator. As physical applications, we connect this new model to two important and novelty problems: the relativistic parametric amplifier and the quantum simulation of a single trapped ion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct Observation of Defect Range and Evolution in Ion-Irradiated Single Crystalline Ni and Ni Binary Alloys

We report that energetic ions have been widely used to evaluate the irradiation tolerance of structural materials for nuclear power applications and to modify material properties. It is important to understand the defect production, annihilation and migration mechanisms during and after collision cascades. In this study, single crystalline pure nickel metal and single-phase concentrated solid solution alloys of 50%Ni50%Co (NiCo) and 50%Ni50%Fe (NiFe) without apparent preexisting defect sinks were employed to study defect dynamics under ion irradiation. Both cross-sectional transmission electron microscopy characterization (TEM) and Rutherford backscattering spectrometry channeling (RBS-C) spectra show that the range of radiation-induced defect clusters far exceed the theoretically predicted depth in all materials after high-dose irradiation. Defects in nickel migrate faster than in NiCo and NiFe. Both vacancy-type stacking fault tetrahedra (SFT) and interstitial loops coexist in the same region, which is consistent with molecular dynamics simulations. Kinetic activation relaxation technique (k-ART) simulations for nickel showed that small vacancy clusters, such as di-vacancies and tri-vacancies, created by collision cascades are highly mobile, even at room temperature. The slower migration of defects in the alloy along with more localized energy dissipation of the displacement cascade may lead to enhanced radiation tolerance.

36 MATERIALS SCIENCE↗

Investigation on optical absorption properties of ion irradiated single walled carbon nanotubes

In the present study change in the optical absorption properties of single walled carbon nanotubes (SWCNTs) under nickel ion (60 MeV) irradiation at various fluences has been investigated. Langmuir Blodgett technique is used to deposit SWCNT thin film of uniform thickness. AFM analysis shows a network of interconnected bundles of nanotubes. UV-Vis-NIR absorption spectra indicate that the sample mainly contain SWCNTs of semiconducting nature. It has been found in absorption spectra that there is decrease in the intensity of the characteristic SWCNT peaks with increase in fluence. At fluence value 1×10{sup 14} ions/cm{sup 2} there is almost complete suppression of the characteristic SWCNTs peaks.The decrease in the optical absorption with increase in fluence is due to the increase in the disorder in the system which leads to the decrease in optically active states.

36 MATERIALS SCIENCE↗

Controlling single rare earth ion emission in an electro-optical nanocavity

Abstract Rare earth emitters enable critical quantum resources including spin qubits, single photon sources, and quantum memories. Yet, probing of single ions remains challenging due to low emission rate of their intra-4 f optical transitions. One feasible approach is through Purcell-enhanced emission in optical cavities. The ability to modulate cavity-ion coupling in real-time will further elevate the capacity of such systems. Here, we demonstrate direct control of single ion emission by embedding erbium dopants in an electro-optically active photonic crystal cavity patterned from thin-film lithium niobate. Purcell factor over 170 enables single ion detection, which is verified by second-order autocorrelation measurement. Dynamic control of emission rate is realized by leveraging electro-optic tuning of resonance frequency. Using this feature, storage, and retrieval of single ion excitation is further demonstrated, without perturbing the emission characteristics. These results promise new opportunities for controllable single-photon sources and efficient spin-photon interfaces.

42 ENGINEERING↗