Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE INTEGRATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurement of Charged-current Muon Neutrino–argon Interactions Without Final-state Pions Using the MicroBooNE Detector

This thesis presents a new high-statistics measurement of flux-integrated single- and double-differential cross sections for charged-current muon neutrino interactions on argon nuclei without final-state pions. The analysis utilizes the full 1.3 $\times$ $10^{21}$ protons-on-target dataset collected by the MicroBooNE liquid argon time projection chamber between 2015 and 2020 at Fermilab's Booster Neutrino Beam. The results of this study are reported with respect to final-state muon kinematic variables and compared with predictions from commonly used neutrino event generators. In one-dimensional distributions, all generators perform reasonably well. However, in two dimensions, only a few demonstrate good agreement with the data. These findings provide valuable insight into characterizing neutrino-nucleon interactions. Such advancements are vital for future long-baseline neutrino experiments, which aim to accurately measure neutrino oscillation and investigate beyond-the-Standard-Model physics with high sensitivity.

Englezos, Panagiotis [Rutgers U., Piscataway (main↗

An Innovative Hybrid Loop-Pool Design for Sodium Cooled Fast Reactor

The existing sodium cooled fast reactors (SFR) have two types of designs – loop type and pool type. In the loop type design, such as JOYO (Japan) [1] and MONJU (Japan), the primary coolant is circulated through intermediate heat exchangers (IHX) external to the reactor tank. The major advantages of loop design include compactness and easy maintenance. The disadvantage is higher possibility of sodium leakage. In the pool type design such as EBR-II (USA), BN-600M(Russia), Superphénix (France) and European Fast Reactor [2], the reactor core, primary pumps, IHXs and direct reactor auxiliary cooling system (DRACS) heat exchangers (DHX) all are immersed in a pool of sodium coolant within the reactor vessel, making a loss of primary coolant extremely unlikely. However, the pool type design makes primary system large. In the latest ANL’s Advanced Burner Test Reactor (ABTR) design [3], the primary system is configured in a pool-type arrangement. The hot sodium at core outlet temperature in hot pool is separated from the cold sodium at core inlet temperature in cold pool by a single integrated structure called Redan. Redan provides the exchange of the hot sodium from hot pool to cold pool through IHXs. The IHXs were chosen as the traditional tube-shell design. This type of IHXs is large in size and hence large reactor vessel is needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Closure Strategy for a Waste Disposal Facility with Multiple Waste Types and Regulatory Drivers at the Nevada Test Site

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) plans to close the waste and classified material storage cells in the southeast quadrant of the Area 5 Radioactive Waste Management Site (RWMS), informally known as the '92-Acre Area', by 2011. The 25 shallow trenches and pits and the 13 Greater Confinement Disposal (GCD) borings contain various waste streams including low-level waste (LLW), low-level mixed waste (LLMW), transuranic (TRU), mixed transuranic (MTRU), and high specific activity LLW. The cells are managed under several regulatory and permit programs by the U.S. Department of Energy (DOE) and the Nevada Division of Environmental Protection (NDEP). Although the specific closure requirements for each cell vary, 37 closely spaced cells will be closed under a single integrated monolayer evapotranspirative (ET) final cover. One cell will be closed under a separate cover concurrently. The site setting and climate constrain transport pathways and are factors in the technical approach to closure and performance assessment. Successful implementation of the integrated closure plan requires excellent communication and coordination between NNSA/NSO and the regulators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-differential and integral cross sections for electron-impact ionization for the damage of carbon clusters irradiated with x-ray free-electron lasers

Single-differential and integral cross sections for electron-impact ionization of the C atom and its ions were calculated with the binary-encounter-dipole model [Y.-K. Kim and M. E. Rudd, Phys. Rev. A 50, 3954 (1994)] to study the distribution of free-electron energies in carbon clusters after being irradiated with an x-ray free-electron laser (XFEL). The averaged energies of the secondary electrons for the C atom, and C{sup 1+}, C{sup 2+}, and C{sup 3+} ions were about 20, 70, 160, and 200 eV, respectively, when incident electron energy was about 20 keV, while those energies were in the order of tens of electronvolts when the incident electron energy was about 250 eV. The damage to carbon clusters irradiated with the XFEL was also investigated with time-dependent rate equations, considering photoionization, Compton scattering, Auger decay, and electron-impact ionization of the C atom and its ions. The results show that the electron-impact ionization becomes a more important process as the x-ray flux decreases, while the effect of Auger decay gradually appears as the x-ray flux increases. The energy dependence of the incident x ray was also investigated to evaluate the resolution of the diffraction pattern. These results indicate that we should make the XFEL pulse a few fs and about 16 keV to suppress damage and obtain desired resolution of the diffraction pattern.

74 ATOMIC AND MOLECULAR PHYSICS↗

Analysis of the elliptic integrable non-linear system in IOTA using tracking of a single electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, A. [Fermilab]↗

Analysis of the Elliptic Integrable Non-Linear System in IOTA Using Tracking of a Single Electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, Aleksandr Leonidovich [Fermilab] (ORCID:0↗

Appurtenance Influence on Type III Hanford Single-Shell Tank Structural Integrity

The interim stabilized Hanford Single Shell Tanks (SSTs) are currently undergoing a state of the art analysis to assess the structural integrity of the waste storage tanks, for cleanup and closure operations, considering their adverse thermal histories and an updated seismic hazard for the Hanford Site near Richland, Washington. The SSTs contain a variety of ancillary pits, piping, piping supports, risers, equipment, and penetrations known as appurtenances. These appurtenances may alter the structural response and ultimately could affect the structural integrity of the SSTs. An important challenge to the structural analysis of the SSTs is determining the impact of these appurtenances on structural integrity. To achieve this, the various appurtenances were reviewed and bounding appurtenance configurations for SST Types II and III tank designs were analyzed using finite element software. The bounding configurations for the Type II tanks considered four heavy offset pits with a central pit with and without a 36-inch diameter central post-construction penetration and four 42-inch diameter offset penetrations. The bounding configuration for the Type III tanks is a tank with two heavy offset pits and one heavy central pit. For each bounding configuration two finite element models are developed: a seismic analysis model and a thermal and operating loads analysis (TOLA) model. The TOLA models include a Type II or III thermal history, concrete cracking and thermal degradation, reinforcement yielding, and soil plasticity. Additionally, operating loads such as internal waste pressure and concentrated and distributed soil surface loads are applied to the TOLA model. The seismic model treats the tank concrete as linear elastic based on the present day degraded concrete properties. Also, in the seismic model the soil is treated as linear elastic while special techniques are used in the soil above the tank dome and along the tank wall to avoid soil arching and achieve the proper soil pressure on the tank walls. Seismic time histories (in the horizontal and vertical directions) are applied to the seismic model. The American Concrete Institute (ACI) has code requirements for nuclear safety-related concrete structures (ACI-349-06) that are used to evaluate the structural integrity of the SSTs. ACI-349-06 recommends evaluating factored load combinations against reduced tank section capacities to account for both loading and material uncertainties. From both the TOLA and seismic models the structural demands (forces and moments) are extracted from sections throughout the tank under the appropriate load combinations. These demands are compared against the ACI-349-06 capacities at each of the sections. This ratio of demand to capacity is reported as a measure of structural integrity. The Type II and Type III appurtenances configurations are found to increase the demand to capacity ratios in local regions near the appurtenances. Away from the appurtenances the influence on structural integrity is minor. A comparison of the Type II and III results show that even though the Type II offset pits weight less, they have a larger impact on the structural integrity of the tanks due to their locations. Finally, lessons learned from the Type II and Type III appurtenance analysis, and their application to the more complex Type IV structural integrity analysis, will be discussed.

appurtenances↗

Fully integrated InGaAs/InP single-photon detector module with gigahertz sine wave gating

InGaAs/InP single-photon avalanche diodes (SPADs) working in the regime of GHz clock rates are crucial components for the high-speed quantum key distribution (QKD). We have developed for the first time a compact, stable, and user-friendly tabletop InGaAs/InP single-photon detector system operating at a 1.25 GHz gate rate that fully integrates functions for controlling and optimizing SPAD performance. We characterize the key parameters of the detector system and test the long-term stability of the system for continuous operation of 75 h. The detector system can substantially enhance QKD performance and our present work paves the way for practical high-speed QKD applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OVERVIEW OF ENHANCED HANFORD SINGLE-SHELL TANK (SST) INTEGRITY PROJECT - 12128

To improve the understanding of the single-shell tanks integrity, Washington River Protection Solutions, LLC, the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank (SST) Integrity Project in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration, Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase has been focused on efforts to envelope the integrity of the tanks. The initial phase was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary based on the outcome from the initial work, a second phase would be focused on further definition of the integrity of the concrete and liners. Combined these two phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by Independent Qualified Registered Engineer. The work to further define the DOE's understanding of the structural integrity SSTs involves preparing a modern Analysis of Record using a finite element analysis program. Structural analyses of the SSTs have been conducted since 1957, but these analyses used analog calculation, less rigorous models, or focused on individual structures. As such, an integrated understanding of all of the SSTs has not been developed to modern expectations. In support of this effort, other milestones will address the visual inspection of the tank concrete and the collection of concrete core samples from the tanks for analysis of current mechanics properties. The work on the liner leak integrity has examined the leaks from 23 tanks with liner failures. Individual leak assessments are being developed for each tank to identify the leak cause and location. Also a common cause study is being performed to take the data from individual tanks to look for trends in the failure. Supporting this work is an assessment of the leak rate from tanks at both Hanford and the Savannah River Site and a new method to locate leak sites in tank liner using ionic conductivity. A separate activity is being conducted to examine the propensity for corrosion in select single shell tanks with aggressive waste layers. The work for these two main efforts will provide the basis for the phase two planning. If the margins identified aren't sufficient to ensure the integrity through the life of the mission, phase two would focus on activities to further enhance the understanding of tank integrity. Also coincident with any phase-two work would be the integrity analysis for the tanks, which would be complete in 2018. With delays in the completion of waste treatment facilities at Hanford, greater reliance on safe, continued storage of waste in the single shell tanks is increased in importance. The goal of integrity assessment would provide basis to continue SST activities till the end of the treatment mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress of the Enhanced Hanford Single Shell Tank (SST) Integrity Project

To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress of the enhanced Hanford single shell tank (SST) integrity project - 15497

To improve understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the US DOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matter experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration. In late 2010, seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase was focused on efforts to envelope the integrity of the tanks. The initial phase was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary, based on the outcome from the initial work, second phase would be focused on further definition of the integrity of the tanks and liners. Combined these two phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by an Independent Qualified Registered Engineer. As the initial phase of this work completes in early 2015, this paper summarizes the project formation and status the work of the past few years associated the implementation of the Phase one recommendations. Work in the initial phase to further define the DOE's understanding of the structural integrity SSTs involved preparing a modern Analysis of Record (AOR) using finite element analysis. Structural analyses of the SSTs have been conducted since 1957, but these analyses used analog calculations, less rigorous models, or focused on individual structures. As such, an integrated understanding of all of the SSTs has not been developed to modern expectations. In support of this effort, other activities addressed the visual inspection of tank internal conditions and the collection of concrete core samples from the tanks, including a full height tank sidewall core, for analysis of current mechanics properties. The work on the liner leak integrity has examined leaks from 25 tanks with known liner failures. Individual leak assessments were developed for each tank to identify the leak cause and location and estimate historic leak rates. A common cause/failure analysis study was performed to take data from individual tanks to look for trends in the causes of failure. A separate activity is being conducted to examine the propensity for corrosion in select SSTs with aggressive waste layers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lithium-niobate-on-insulator waveguide-integrated superconducting nanowire single-photon detectors

Here, we demonstrate waveguide-integrated superconducting nanowire single-photon detectors on thin-film lithium niobate (LiNbO 3 , LN). Using a 250 μm-long NbN superconducting nanowire lithographically defined on top of a 125 μm-long LN nanowaveguide, an on-chip detection efficiency of 46% is realized with simultaneous high performance in dark count rates and timing jitter. As LN possesses high χ (2) second-order nonlinear and electro-optic properties, an efficient single-photon detector on thin-film LN opens up the possibility to construct a small-scale fully integrated quantum photonic chip, which includes single-photon sources, filters, tunable quantum gates, and detectors.

42 ENGINEERING↗

SINGLE-SHELL TANK INTEGRITY PROJECT ANALYSIS OF RECORD-PRELIMINARY MODELING PLAN FOR THERMAL AND OPERATING LOADS

This document is a Phase I deliverable for the Single-Shell Tank Analysis of Record effort. This document is not the Analysis of Record. The intent of this document is to guide the Phase II detailed modeling effort. Preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. The preliminary analysis document reviews and preliminary modeling analysis results are reported herein. In addition, this report provides recommendations for the next phase of the SST AOR project, SST detailed modeling. Efforts and results discussed in this report do not include seismic modeling as seismic modeling is covered by a separate report. The combined results of both static and seismic models are required to complete this effort. The SST AOR project supports the US Department of Energy's (DOE) Office of River Protection (ORP) mission for obtaining a better understanding of the structural integrity of Hanford's SSTs. The 149 SSTs, with six different geometries, have experienced a range of operating histories which would require a large number of unique analyses to fully characterize their individual structural integrity. Preliminary modeling evaluations were conducted to determine the number of analyses required for adequate bounding of each of the SST tank types in the Detailed Modeling Phase of the SST AOR Project. The preliminary modeling was conducted in conjunction with the Evaluation Criteria report, Johnson et al. (2010). Reviews of existing documents were conducted at the initial stage of preliminary modeling. These reviews guided the topics that were explored in the SST preliminary modeling. The reviews determined the level of detail necessary to perform the analyses of the SSTs. To guide the Phase II detailed modeling effort, preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. Conclusions were derived from case studies on one of the tank types when no additional runs of similar cases on other types of tanks were found necessary to derive those conclusions. The document reviews provided relatively complete temperature histories for Type IV tanks. The temperature history data for Type I, II, and III tanks was almost nonexistent for years prior to 1975. Document reviews indicate that there might be additional useful data in the US Department of Energy, Richland Operations Office (DOE-RL) records in Seattle, WA, and these records need to be reviewed to extract data that might have been disregarded during previous reviews. Thermal stress analyses were conducted using different temperature distribution scenarios on Type IV tanks. Such studies could not be carried out for other tank types due to lack of temperature history data. The results from Type IV tank analyses indicate that factors such as temperature distribution in the tank waste and rate of rise in waste temperature have a significant impact on the thermal stresses in the tank structures. Overall, the conclusion that can drawn from the thermal stress analyses is that these studies should be carried out for all tank types during the detailed analysis phase with temperature values that are reasonably close to the typical temperature histories of the respective tank types. If and/or when additional waste temperature data is acquired for tank Type I, II, and III tanks, additional cases need to be considered as tank structural integrity is sensitive to thermal loads. A few case studies were also performed using Type IV-b models to comprehend the effects of excavation boundaries, change in soil stratigraphy (layer thickness and properties), and radial extent of soil in the finite element models. The result from the case studies indicates that the slight variation in soil stratigraphy has little effects on the tank sections force and moment demands under mechanical loads. The case study for excavation slope or backfill transition boundary indicated that inclusion of such boundary yields conservative demands in the wall region while demands at other locations remain unaffected. Hence this excavation slope will be modeled in the detailed analysis of SSTs.

54 ENVIRONMENTAL SCIENCES↗

Structure of the pre-mRNA leakage 39-kDa protein reveals a single domain of integrated zf-C3HC and Rsm1 modules

In Saccharomyces cerevisiae, the pre-mRNA leakage 39-kDa protein (ScPml39) was reported to retain unspliced pre-mRNA prior to export through nuclear pore complexes (NPCs). Pml39 homologs outside the Saccharomycetaceae family are currently unknown, and mechanistic insight into Pml39 function is lacking. Here we determined the crystal structure of ScPml39 at 2.5 Å resolution to facilitate the discovery of orthologs beyond Saccharomycetaceae, e.g. in Schizosaccharomyces pombe or human. The crystal structure revealed integrated zf-C3HC and Rsm1 modules, which are tightly associated through a hydrophobic interface to form a single domain. Both zf-C3HC and Rsm1 modules belong to the Zn-containing BIR (Baculovirus IAP repeat)-like super family, with key residues of the canonical BIR domain being conserved. Features unique to the Pml39 modules refer to the spacing between the Zn-coordinating residues, giving rise to a substantially tilted helix αC in the zf-C3HC and Rsm1 modules, and an extra helix αAB' in the Rsm1 module. Conservation of key residues responsible for its distinct features identifies S. pombe Rsm1 and Homo sapiens NIPA/ZC3HC1 as structural orthologs of ScPml39. Based on the recent functional characterization of NIPA/ZC3HC1 as a scaffold protein that stabilizes the nuclear basket of the NPC, our data suggest an analogous function of ScPml39 in S. cerevisiae.

59 BASIC BIOLOGICAL SCIENCES↗

Integrator Circuitry for Single Channel Radiation Detector

Input circuitry is provided for a high voltage operated radiation detector to receive pulses from the detector having a rise time in the range of from about one nanosecond to about ten nanoseconds. An integrator circuit, which utilizes current feedback, receives the incoming charge from the radiation detector and creates voltage by integrating across a small capacitor. The integrator utilizes an amplifier which closely follows the voltage across the capacitor to produce an integrator output pulse with a peak value which may be used to determine the energy which produced the pulse. The pulse width of the output is stretched to approximately 50 to 300 nanoseconds for use by subsequent circuits which may then use amplifiers with lower slew rates.

Holland, Samuel D.↗

Appurtenance Influence on Type III Hanford Single-Shell Tank Structural Integrity - 12255

The interim stabilized Hanford Single-Shell Tanks (SSTs) are currently undergoing a state of the art analysis to assess the structural integrity of the waste storage tanks, for cleanup and closure operations, considering their adverse thermal histories and an updated seismic hazard for the Hanford Site near Richland, Washington. The SSTs contain a variety of ancillary pits, piping, piping supports, risers, equipment, and penetrations known as appurtenances. These appurtenances may alter the structural response and ultimately could affect the structural integrity of the SSTs. An important challenge to the structural analysis of the SSTs is to determine the impact of these appurtenances on structural integrity. To achieve this, the various appurtenances were reviewed and a bounding appurtenance configuration for the SST Type III tanks was analyzed using finite element models for both thermal and operating loads as well as seismic loads. Tank structural demands from the finite element analyses were evaluated according to American Concrete Institute (ACI-349) code requirements to determine the tank structural integrity. The appurtenances configuration is found to increase the demand to capacity ratios in local regions near the appurtenances. Away from the appurtenances the influence on structural integrity is minor. The ACI-349-06 evaluation of the Type III SST bounding appurtenance configuration shows the tank is still structurally sound under all evaluated load combinations. When the appurtenance model D/C ratios were compared to those from the baseline axisymmetric model it was found that there were significant differences in the results, particularly under seismic loading conditions. This indicates that the effect of appurtenances on tank structural integrity should at least be considered in all SST AORs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct monolithic integration of vertical single crystalline octahedral molecular sieve nanowires on silicon

We developed an original strategy to produce vertical epitaxial single crystalline manganese oxide octahedral molecular sieve (OMS) nanowires with tunable pore sizes and compositions on silicon substrates by using a chemical solution deposition approach. The nanowire growth mechanism involves the use of track-etched nanoporous polymer templates combined with the controlled growth of quartz thin films at the silicon surface, which allowed OMS nanowires to stabilize and crystallize. α-quartz thin films were obtained after thermal activated crystallization of the native amorphous silica surface layer assisted by Sr 2+ - or Ba 2+ -mediated heterogeneous catalysis in the air at 800 °C. These α-quartz thin films work as a selective template for the epitaxial growth of randomly oriented vertical OMS nanowires. Furthermore, the combination of soft chemistry and epitaxial growth opens new opportunities for the effective integration of novel technological functional tunneled complex oxides nanomaterials on Si substrates.

36 MATERIALS SCIENCE↗

Overview of Hanford Single Shell Tank (SST) Structural Integrity

To improve the understanding of the single-shell tanks (SSTs) integrity, Washington River Protection Solutions, LLC (WRPS), the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration, Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The structural integrity of the tanks is a key element in completing the cleanup mission at the Hanford Site. There are eight primary recommendations related to the structural integrity of Hanford Single-Shell Tanks. Six recommendations are being implemented through current and planned activities. The structural integrity of the Hanford is being evaluated through analysis, monitoring, inspection, materials testing, and construction document review. Structural evaluation in the form of analysis is performed using modern finite element models generated in ANSYS. The analyses consider in-situ, thermal, operating loads and natural phenomena such as earthquakes. Structural analysis of 108 of 149 Hanford Single-Shell Tanks has concluded that the tanks are structurally sound and meet current industry standards. Analysis of the remaining Hanford Single-Shell Tanks is scheduled for FY2014. Hanford Single-Shell Tanks are monitored through a dome deflection program. The program looks for deflections of the tank dome greater than 1/4 inch. No such deflections have been recorded. The tanks are also subjected to visual inspection. Digital cameras record the interior surface of the concrete tanks, looking for cracks and other surface conditions that may indicate signs of structural distress. The condition of the concrete and rebar of the Hanford Single-Shell Tanks is currently being tested and planned for additional activities in the near future. Concrete and rebar removed from the dome of a 65 year old tank was tested for mechanics properties and condition. Results indicated stronger than designed concrete with additional Petrographic examination and rebar completed. Material properties determined from previous efforts combined with current testing and construction document review will help to generate a database that will provide indication of Hanford Single-Shell Tank structural integrity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗