Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multi-images deconvolution improves signal-to-noise ratio on gated stimulated emission depletion microscopy

Time-gated detection, namely, only collecting the fluorescence photons after a time-delay from the excitation events, reduces complexity, cost, and illumination intensity of a stimulated emission depletion (STED) microscope. In the gated continuous-wave- (CW-) STED implementation, the spatial resolution improves with increased time-delay, but the signal-to-noise ratio (SNR) reduces. Thus, in sub-optimal conditions, such as a low photon-budget regime, the SNR reduction can cancel-out the expected gain in resolution. Here, we propose a method which does not discard photons, but instead collects all the photons in different time-gates and recombines them through a multi-image deconvolution. Our results, obtained on simulated and experimental data, show that the SNR of the restored image improves relative to the gated image, thereby improving the effective resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A HIGH SIGNAL-TO-NOISE RATIO COMPOSITE SPECTRUM OF GAMMA-RAY BURST AFTERGLOWS

We present a composite spectrum of 60 long duration gamma-ray burst (GRB) afterglows with redshifts in the range 0.35 < z < 6.7 observed with low-resolution optical spectra. The composite spectrum covers the wavelength range 700-6600 A in the rest frame and has a mean signal-to-noise ratio of 150 per 1 A pixel and reaches a maximum of {approx}300 in the range 2500-3500 A. Equivalent widths are measured from metal absorption lines from the Ly{alpha} line to {approx}5200 A, and associated metal and hydrogen lines are identified between the Lyman break and Ly{alpha} line. The average transmission within the Lyman forest is consistent with that found along quasar lines of sight. We find a temporal variation in fine-structure lines when dividing the sample into bursts observed within 2 hr from their trigger and those observed later. Other lines in the predominantly neutral gas show variations too, but this is most likely a random effect caused by weighting of individual strong absorption lines and which mimics a temporal variation. Bursts characterized with high- or low-prompt GRB energy release produce afterglows with similar absorption line strengths, and likewise for bursts with bright or faint optical afterglows. Bursts defined as dark from their optical to X-ray spectral index have stronger absorption lines relative to the optically bright bursts. The composite spectrum has strong Ca II and Mg II absorption lines as commonly found in dusty galaxies, however, we find no evidence for dust or a significant molecular content based on the non-detection of diffuse interstellar bands. Compared to starburst galaxy spectra, the GRB composite has much stronger fine-structure lines, while metal absorption lines are weaker.

79 ASTRONOMY AND ASTROPHYSICS↗

Design considerations for a LORAN-C timing receiver in a hostile signal to noise environment

The environment in which a LORAN-C Timing Receiver may function effectively depends to a large extent on the techniques utilized to insure that interfering signals within the pass band of the unit are neutralized. The baseline performance manually operated timing receivers is discussed and the basic design considerations and necessary parameters for an automatic unit utilizing today's technology are established. Actual performance data is presented comparing the results obtained from a present generation timing receiver against a new generation microprocessor controlled automatic acquisition receiver. The achievements possible in a wide range of signal to noise situations are demonstrated.

Porter, J. W.↗

Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ{sub 0} = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for Interstellar C{sub 60}{sup +} Using a New Method for High Signal-to-noise HST/STIS Spectroscopy

Due to recent advances in laboratory spectroscopy, the first optical detection of a very large molecule has been claimed in the diffuse interstellar medium (ISM): C{sub 60}{sup +} (ionized Buckminsterfullerene). Confirming the presence of this molecule would have significant implications regarding the carbon budget and chemical complexity of the ISM. Here we present results from a new method for ultra-high signal-to-noise ratio (S/N) spectroscopy of background stars in the near-infrared (at wavelengths of 0.9–1 μm), using the Hubble Space Telescope (HST) Imaging Spectrograph (STIS) in a previously untested “STIS scan” mode. The use of HST provides the crucial benefit of eliminating the need for error-prone telluric-correction methods in the part of the spectrum where the C{sub 60}{sup +} bands lie and where the terrestrial water vapor contamination is severe. Our STIS spectrum of the heavily reddened B0 supergiant star BD+63 1964 reaches an unprecedented S/N for this instrument (∼600–800), allowing the detection of the diffuse interstellar band (DIB) at 9577 Å attributed to C{sub 60}{sup +}, as well as new DIBs in the near-IR. Unfortunately, the presence of overlapping stellar lines, and the unexpected weakness of the C{sub 60}{sup +} bands in this sightline, prevents conclusive detection of the weaker C{sub 60}{sup +} bands. A probable correlation between the 9577 Å DIB strength and interstellar radiation field is identified, which suggests that more strongly irradiated interstellar sightlines will provide the optimal targets for future C{sub 60}{sup +} searches.

79 ASTRONOMY AND ASTROPHYSICS↗

On the signal-to-noise ratio in IUE high-dispersion spectra

An observational and data reduction technique for fixed pattern noise (FPN) and random noise (RN) in fully extracted IUE high-dispersion spectra is described in detail, along with actual empirical values of signal-to-noise ratio (S/N) achieved. A co-addition procedure, involving SWP and LWR cameras observations of the same spectrum at different positions in the image format, provides a basis to disentangle FPN from RN, allowing each average amplitude, within a given wavelength interval, to be estimated as a function of average flux number. Empirical curves, derived with the noise algorithm, make it possible to estimate the S/N in individual spectra at the wavelengths investigated. The average S/N at the continuum level in well-exposed stellar spectra varies from 10 to 20, for the orders analyzed, depending on position in the spectral format. The co-addition procedure yields an improvement in S/N by factors ranging from 2.3 to 2.9. Direct measurements of S/N in narrow, line-free wavelength intervals of individual and co-added spectra for weak-lined stars yield comparable, or in some cases somewhat higher, S/N values and improvement factors.

Leckrone, David S.↗

Multilayered optical bit memory with a high signal-to-noise ratio in fluorescent polymethylmethacrylate

We report on the three-dimensional optical memory utilizing a photoluminescence (PL) change in polymethylmethacrylate. Irradiation with a femtosecond pulsed laser (800 nm, 1 kHz, 100 fs) induced a strong PL spectrum in the visible range, which may result from the photogeneration of emissive radicals. Multilayered patterns were recorded inside the bulk sample by tightly focusing a pulsed laser beam. The pattern images were read out by a reflection-type fluorescent confocal microscope which detected the blue-green emission at 410-510 nm. The stored bits were retrieved with a high signal-to-noise ratio in the absence of any cross-talk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of exposure equalization on image signal-to-noise ratios in digital mammography: A simulation study with an anthropomorphic breast phantom

Purpose: The scan equalization digital mammography (SEDM) technique combines slot scanning and exposure equalization to improve low-contrast performance of digital mammography in dense tissue areas. In this study, full-field digital mammography (FFDM) images of an anthropomorphic breast phantom acquired with an anti-scatter grid at various exposure levels were superimposed to simulate SEDM images and investigate the improvement of low-contrast performance as quantified by primary signal-to-noise ratios (PSNRs). Methods: We imaged an anthropomorphic breast phantom (Gammex 169 ''Rachel,'' Gammex RMI, Middleton, WI) at various exposure levels using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, WI). The exposure equalization factors were computed based on a standard FFDM image acquired in the automatic exposure control (AEC) mode. The equalized image was simulated and constructed by superimposing a selected set of FFDM images acquired at 2, 1, 1/2, 1/4, 1/8, 1/16, and 1/32 times of exposure levels to the standard AEC timed technique (125 mAs) using the equalization factors computed for each region. Finally, the equalized image was renormalized regionally with the exposure equalization factors to result in an appearance similar to that with standard digital mammography. Two sets of FFDM images were acquired to allow for two identically, but independently, formed equalized images to be subtracted from each other to estimate the noise levels. Similarly, two identically but independently acquired standard FFDM images were subtracted to estimate the noise levels. Corrections were applied to remove the excess system noise accumulated during image superimposition in forming the equalized image. PSNRs over the compressed area of breast phantom were computed and used to quantitatively study the effects of exposure equalization on low-contrast performance in digital mammography. Results: We found that the highest achievable PSNR improvement factor was 1.89 for the anthropomorphic breast phantom used in this study. The overall PSNRs were measured to be 79.6 for the FFDM imaging and 107.6 for the simulated SEDM imaging on average in the compressed area of breast phantom, resulting in an average improvement of PSNR by {approx}35% with exposure equalization. We also found that the PSNRs appeared to be largely uniform with exposure equalization, and the standard deviations of PSNRs were estimated to be 10.3 and 7.9 for the FFDM imaging and the simulated SEDM imaging, respectively. The average glandular dose for SEDM was estimated to be 212.5 mrad, {approx}34% lower than that of standard AEC-timed FFDM (323.8 mrad) as a result of exposure equalization for the entire breast phantom. Conclusions: Exposure equalization was found to substantially improve image PSNRs in dense tissue regions and result in more uniform image PSNRs. This improvement may lead to better low-contrast performance in detecting and visualizing soft tissue masses and micro-calcifications in dense tissue areas for breast imaging tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Expanded Signal to Noise Ratio Estimates for Validating Next-Generation Satellite Sensors in Oceanic, Coastal, and Inland Waters

The launch of the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) and the Surface Biology and Geology (SBG) satellite sensors will provide increased spectral resolution compared to existing platforms. These new sensors will require robust calibration and validation datasets, but existing field-based instrumentation is limited in its availability and potential for geographic coverage, particularly for coastal and inland waters, where optical complexity is substantially greater than in the open ocean. The minimum signal-to-noise ratio (SNR) is an important metric for assessing the reliability of derived biogeochemical products and their subsequent use as proxies, such as for biomass, in aquatic systems. The SNR can provide insight into whether legacy sensors can be used for algorithm development as well as calibration and validation activities for next-generation platforms. We extend our previous evaluation of SNR and associated uncertainties for representative coastal and inland targets to include the imaging sensors PRISM and AVIRIS-NG, the airborne-deployed C-AIR radiometers, and the shipboard HydroRad and HyperSAS radiometers, which were not included in the original analysis. Nearly all the assessed hyperspectral sensors fail to meet proposed criteria for SNR or uncertainty in remote sensing reflectance (R rs ) for some part of the spectrum, with the most common failures (>20% uncertainty) below 400 nm, but all the sensors were below the proposed 17.5% uncertainty for derived chlorophyll-a. Instrument suites for both in-water and airborne platforms that are capable of exceeding all the proposed thresholds for SNR and R rs uncertainty are commercially available. Thus, there is a straightforward path to obtaining calibration and validation data for current and next-generation sensors, but the availability of suitable high spectral resolution sensors is limited.

signal-to-noise ratio↗

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

Integrated path differential absorption (IPDA) lidar can be used to remotely measure the column density of gases in the path to a scattering target [1]. The total column gas molecular density can be derived from the ratio of the laser echo signal power with the laser wavelength on the gas absorption line (on-line) to that off the line (off-line). 80th coherent detection and direct detection IPDA lidar have been used successfully in the past in horizontal path and airborne remote sensing measurements. However, for space based measurements, the signal propagation losses are often orders of magnitude higher and it is important to use the most efficient laser modulation and detection technique to minimize the average laser power and the electrical power from the spacecraft. This paper gives an analysis the receiver signal to noise ratio (SNR) of several laser modulation and detection techniques versus the average received laser power under similar operation environments. Coherent detection [2] can give the best receiver performance when the local oscillator laser is relatively strong and the heterodyne mixing losses are negligible. Coherent detection has a high signal gain and a very narrow bandwidth for the background light and detector dark noise. However, coherent detection must maintain a high degree of coherence between the local oscillator laser and the received signal in both temporal and spatial modes. This often results in a high system complexity and low overall measurement efficiency. For measurements through atmosphere the coherence diameter of the received signal also limits the useful size of the receiver telescope. Direct detection IPDA lidars are simpler to build and have fewer constraints on the transmitter and receiver components. They can use much larger size 'photon-bucket' type telescopes to reduce the demands on the laser transmitter. Here we consider the two most widely used direct detection IPDA lidar techniques. The first technique uses two CW seeder lasers, one on-line and one offline that are intensity modulated by two different frequency sine-waves signals before being amplified by a common laser amplifier. The receiver uses narrowband amplitude demodulation, or lock-in, Signal processing at the given laser modulation frequencies [3,4]. The laser transmitter operates in a quasi CW mode with the peak power equal to twice the average power. The on-line and off-line lasers can be transmitted at the same time without interference. Another direct detection technique uses a low duty cycle pulsed laser modulation [5,6] with the laser wavelengths alternating between on-line and off-line on successive pulses. The receiver uses time resolved detection and can also provide simultaneous target range measurement. With a lower laser duty cycle it requires a much higher peak laser power for the same average power.

Sun, Xiaoli↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of signal to noise ratios from spatial and frequency domain formulations of nonprewhitening model observers in digital mammography

Purpose: Image quality indices based upon model observers are promising alternatives to laborious human readings of contrast-detail images. This is especially appealing in digital mammography as limiting values for contrast thresholds determine, according to some international protocols, the acceptability of these systems in the radiological practice. The objective of the present study was to compare the signal to noise ratios (SNR) obtained with two nonprewhitening matched filter model observer approaches, one in the spatial domain and the other in the frequency domain, and with both of them worked out for disks as present in the CDMAM phantom. Methods: The analysis was performed using images acquired with the Siemens Novation and Inspiration digital mammography systems. The spatial domain formulation uses a series of high dose CDMAM images as the signal and a routine exposure of two flood images to calculate the covariance matrix. The frequency domain approach uses the mathematical description of a disk and modulation transfer function (MTF) and noise power spectrum (NPS) calculated from images. Results: For both systems most of the SNR values calculated in the frequency domain were in very good agreement with the SNR values calculated in the spatial domain. Both the formulations in the frequency domain and in the spatial domain show a linear relationship between SNR and the diameter of the CDMAM discs. Conclusions: The results suggest that both formulations of the model observer lead to very similar figures of merit. This is a step forward in the adoption of figures of merit based on NPS and MTF for the acceptance testing of mammography systems.

60 APPLIED LIFE SCIENCES↗

CROSS-CORRELATIONS OF THE Ly{alpha} FOREST WITH WEAK-LENSING CONVERGENCE. ANALYTICAL ESTIMATES OF SIGNAL-TO-NOISE RATIO AND IMPLICATIONS FOR NEUTRINO MASS AND DARK ENERGY

We expect a detectable correlation between two seemingly unrelated quantities: the four-point function of the cosmic microwave background (CMB) and the amplitude of flux decrements in quasar (QSO) spectra. The amplitude of CMB convergence in a given direction measures the projected surface density of matter. Measurements of QSO flux decrements trace the small-scale distribution of gas along a given line of sight. While the cross-correlation between these two measurements is small for a single line of sight, upcoming large surveys should enable its detection. This paper presents analytical estimates for the signal-to-noise ratio (S/N) for measurements of the cross-correlation between the flux decrement and the convergence, <{delta}F{kappa}>, and for measurements of the cross-correlation between the variance in flux decrement and the convergence, <({delta}F){sup 2}{kappa}>. For the ongoing BOSS (SDSS-III) and Planck surveys, we estimate an S/N of 30 and 9.6 for these two correlations. For the proposed BigBOSS and ACTPOL surveys, we estimate an S/N of 130 and 50, respectively. Since <({delta}F){sup 2}{kappa}>{proportional_to}{sigma}{sub 8}{sup 4}, the amplitude of these cross-correlations can potentially be used to measure the amplitude of {sigma}{sub 8} at z {approx} 2%-2.5% with BOSS and Planck and even better with future data sets. These measurements have the potential to test alternative theories for dark energy and to constrain the mass of the neutrino. The large potential signal estimated in our analytical calculations motivates tests with nonlinear hydrodynamic simulations and analyses of upcoming data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

The atmosphere as a research window - Signal or noise

The interpretation of measurements by instruments with FOV that are large enough to contain pronounced radiometric variations is discussed, focusing on the retrieval of cloud properties from satellite radiance measurements. Examples are presented for three retrieval approaches. The use of a physical principle to establish a relationship between the measurement and the desired parameter is shown for cirrus-cloud optical depth and precipitation from passive microwave measurements. Examples of the use of inherent variability of the atmosphere and the statistical character of this variability are the spatial covariance method and the threshold method. Also, two examples using a hybrid of these two methods are presented. It is shown that the natural variability (noise) within the instrument FOV biases the relationship between the measurement and the parameter of interest which would be predicted by simple one-dimensional radiative-transfer theory. It is suggested that the noise of the measurement also contains signal, forming the basis for hybrid methods.

Stephens, Graeme L.↗

Coherent dual-comb spectroscopy at high signal-to-noise ratio

Two coherent frequency combs are used to measure the full complex response of a sample in a configuration analogous to a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual-comb spectrometer retains the frequency accuracy and resolution of the reference underlying the stabilized combs. We discuss the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) over the 9 THz bandwidth is 2500 for both the magnitude and phase of the measured spectral response and the peak SNR is 4000. This peak SNR corresponds to a fractional absorption sensitivity of 0.05% and a phase sensitivity of 250 microradians. As the spectral coverage of combs expands, coherent dual-comb spectroscopy could provide high-frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions. Work of U. S. government, not subject to copyright.

74 ATOMIC AND MOLECULAR PHYSICS↗

Unsupervised Dictionary Learning for Signal-to-Noise Ratio Enhancement of Array Data

Waveform enhancement methods generally explore lateral coherency in arrivals, often assuming a linear moveout across an array, as exhibited by plane waves. Here, we illustrate how unsupervised dictionary learning combined with orthogonal matching pursuit for feature extraction can be used for signal-to-noise ratio (SNR) enhancement. In this strategy, waveform characteristics are directly learned from provided data samples; the created dictionary is then used for signal extraction. This combination prevents the need to set a predefined dictionary, and it becomes computationally efficient because learning is only done on smaller data portions. Because the dictionary is learned from data, there is no assumption regarding wavefront shape or form. Tests on synthetic and field data demonstrate the better denoising performance in terms of SNR enhancement compared to other methods.

58 GEOSCIENCES↗