Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL DISTORTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Deep Cryogenic Low Power 24 Bits Analog to Digital Converter with Active Reverse Cryostat

LBNL is developing an innovative data acquisition module for superconductive magnets where the front-end electronics and digitizer resides inside the cryostat. This electronic package allows conventional electronic technologies such as enhanced metal–oxide–semiconductor to work inside cryostats at temperatures as low as 4.2 K. This is achieved by careful management of heat inside the module that keeps the electronic envelop at approximately 85 K. This approach avoids all the difficulties that arise from changes in carrier mobility that occur in semiconductors at deep cryogenic temperatures. There are several advantages in utilizing this system. A significant reduction in electrical noise from signals captured inside the cryostat occurs due to the low temperature that the electronics is immersed in, reducing the thermal noise. The shorter distance that signals are transmitted before digitalization reduces pickup and cross-talk between channels. This improved performance in signal-to-noise rate by itself is a significant advantage. Another important advantage is the simplification of the feedthrough interface on the cryostat head. Data coming out of the cryostat is digital and serial, dramatically reducing the number of lines going through the cryostat feedthrough interface. It is important to notice that all lines coming out of the cryostat are digital and low voltage, reducing the possibility of electric breakdown inside the cryostat. This paper will explain in details the architecture and inner workings of this data acquisition system. It will also provide the performance of the analog to digital converter when the system is immersed in liquid helium, and in liquid nitrogen. Parameters such as power dissipation, integral non-linearity, effective number of bits, signal-to-noise and distortion, will be presented for both temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep learning ferroelectric polarization distributions from STEM data via with and without atom finding

Over the last decade, scanning transmission electron microscopy (STEM) has emerged as a powerful tool for probing atomic structures of complex materials with picometer precision, opening the pathway toward exploring ferroelectric, ferroelastic, and chemical phenomena on the atomic scale. Analyses to date extracting a polarization signal from lattice coupled distortions in STEM imaging rely on discovery of atomic positions from intensity maxima/minima and subsequent calculation of polarization and other order parameter fields from the atomic displacements. Here, we explore the feasibility of polarization mapping directly from the analysis of STEM images using deep convolutional neural networks (DCNNs). In this approach, the DCNN is trained on the labeled part of the image (i.e., for human labelling), and the trained network is subsequently applied to other images. We explore the effects of the choice of the descriptors (centered on atomic columns and grid-based), the effects of observational bias, and whether the network trained on one composition can be applied to a different one. This analysis demonstrates the tremendous potential of the DCNN for the analysis of high-resolution STEM imaging and spectral data and highlights the associated limitations.

36 MATERIALS SCIENCE↗

Decoupling indirect topographic cross-talk in band excitation piezoresponse force microscopy imaging and spectroscopy

Here, all scanning probe microscopies are subjected to topographic cross-talk, meaning the topography-related contrast in functional images. Here, we investigate the signatures of indirect topographic cross-talk in piezoresponse force microscopy (PFM) imaging and spectroscopy and its decoupling using band excitation (BE) method in ferroelectric BaTiO 3 deposited on the Si substrates with free standing nanopillars of diameter 50 nm. Comparison between the single-frequency PFM and BE-PFM results shows that the measured signal can be significantly distorted by topography-induced shifts in the contact resonance frequency and cantilever transfer function. However, with proper correction, such shifts do not affect PFM imaging and hysteresis loop measurements. This suggests the necessity of an advanced approach, such as BE-PFM, for detection of intrinsic sample piezoresponse on the topographically non-uniform surfaces.

36 MATERIALS SCIENCE↗

Acousto-optic laser projection systems for displaying TV information

This review addresses various approaches to television projection imaging on large screens using lasers. Results are presented of theoretical and experimental studies of an acousto-optic projection system operating on the principle of projecting an image of an entire amplitude-modulated television line in a single laser pulse. We consider characteristic features of image formation in such a system and the requirements for its individual components. Particular attention is paid to nonlinear distortions of the image signal, which show up most severely at low modulation signal frequencies. We discuss the feasibility of improving the process efficiency and image quality using acousto-optic modulators and pulsed lasers. Real-time projectors with pulsed line imaging can be used for controlling high-intensity laser radiation. (review)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Identity method to study chemical fluctuations in relativistic heavy-ion collisions

Event-by-event fluctuations of the chemical composition of the hadronic final state of relativistic heavy-ion collisions carry valuable information on the properties of strongly interacting matter produced in the collisions. However, in experiments incomplete particle identification distorts the observed fluctuation signals. The effect is quantitatively studied and a new technique for measuring chemical fluctuations, the identity method, is proposed. The method fully eliminates the effect of incomplete particle identification. The application of the identity method to experimental data is explained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Pixel Pitch-Matched Ultrasound Receiver for 3-D Photoacoustic Imaging With Integrated Delta-Sigma Beamformer in 28-nm UTBB FD-SOI

This study presents a pixel pitch-matched readout chip for 3-D photoacoustic (PA) imaging, featuring a dedicated signal conditioning and delta-sigma modulation integrated within a pixel area of 250 μm by 250 μm. The proof-of-concept receiver was implemented in an STMicroelectronics's 28-nm Fully Depleted Silicon On Insulator technology, and interfaces to a 4 × 4 subarray of capacitive micromachined ultrasound transducers (CMUTs). The front-end signal conditioning in each pixel employs a coarse/fine gain tuning architecture to fulfill the 90-dB dynamic range requirement of the application. The employed delta-sigma beamforming architecture obviates the need for area-consuming Nyquist ADCs and thereby enables an efficient in-pixel A/D conversion. The per-pixel switched-capacitor ΔΣ modulator leverages slewing-dominated and area-optimized inverter-based amplifiers. It occupies only 1/4th of the pixel, and its area compares favorably with state-of-the-art designs that offer the same SNR and bandwidth. The modulator's measured peak signal-to-noise-and-distortion ratio is 59.9 dB for a 10-MHz input bandwidth, and it consumes 6.65 mW from a 1V supply. The overall subarray beamforming approach improves the area per channel by 7.4 times and the single-channel SNR by 8 dB compared to prior art with similar delay resolution and power dissipation. Finally, the functionality of the designed chip was evaluated within a PA imaging experiment, employing a flip-chip bonded 2-D CMUT array.

3-D photoacoustic (PA) imaging↗

Mass agnostic jet taggers

Searching for new physics in large data sets needs a balance between two competing effects—signal identification vs background distortion. In this work, we perform a systematic study of both single variable and multivariate jet tagging methods that aim for this balance. The methods preserve the shape of the background distribution by either augmenting the training procedure or the data itself. Multiple quantitative metrics to compare the methods are considered, for tagging 2-, 3-, or 4-prong jets from the QCD background. This is the first study to show that the data augmentation techniques of Planing and PCA based scaling deliver similar performance as the augmented training techniques of Adversarial NN and uBoost, but are both easier to implement and computationally cheaper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transducer Installation Effects on Pressure Measurements in PGC Devices

Pressure gain devices such as rotating detonation engines present an extremely harsh environment, generally precluding the use of any intrusive probe measurement. The most widely used diagnostic is the measurement of high frequency pressure which can be used to determine the pressure amplitude, number of waves and their direction and the wave structure. The preferred approach for making pressure measurements is to install the sensing element flush with the combustion chamber wall, but is almost always inhibited by the extremely high heat fluxes that can damage the sensor. Alternately, recessed cavity or infinite probe installation is seldom used for high frequency pressure measurements. While amplitude attenuation and phase distortion of the pressure signal can be introduced by these installation types, its characterization in the presence of high amplitude steep fronted pressure waves encountered in PGC devices has not been previously performed. In the current work a highly modular calibration test-bed is designed to enable characterization of pressure transducers based on their installation in the presence of steep fronted high amplitude pressure waves. Two transducer types, piezoelectric PCB® 113B26 and water-cooled piezoresistive Kulite®WCT-312M were used and installed in the flush, recessed cavity and infinite tube probe configuration. The recessed cavity probe showed 5-26% amplitude attenuation and almost negligible time lag compared to the flush transducer, the infinite tube pressure (ITP) transducer showed a significantly higher delay and as much as 50% reduction in measured pressure amplitude. Secondary wave features from reflections within the test article, that were captured by the flush and recessed cavity transducer were damped by the infinite probe measurement.

20 FOSSIL-FUELED POWER PLANTS↗

The TESS Phase Curve of KELT-1b Suggests a High Dayside Albedo

We measured the optical phase curve of the transiting brown dwarf KELT-1b (TOI 1476) using data from the TESS spacecraft. We found that KELT-1b shows significant phase variation in the TESS bandpass, with a relatively large phase amplitude of 234{sub −44}{sup +43} ppm and a secondary eclipse depth of 371{sub −49}{sup +47} ppm. We also measured a marginal eastward offset in the dayside hot spot of 18.°3 ± 7.°4 relative to the substellar point. We detected a strong phase-curve signal attributed to ellipsoidal distortion of the host star with an amplitude of 399 ± 19 ppm. Our results are roughly consistent with the Spitzer phase curves of KELT-1b, but the TESS eclipse depth is deeper than expected. Our cloud-free 1D models of KELT-1b’s dayside emission are unable to fit the full combined eclipse spectrum. Instead, the large TESS eclipse depth suggests that KELT-1b may have a significant dayside geometric albedo of A {sub g} ∼ 0.5 in the TESS bandpass, which would agree with the tentative trend between equilibrium temperature and geometric albedo recently suggested by Wong et al. We posit that if KELT-1b has a high dayside albedo, it is likely due to silicate clouds that form on KELT-1b’s nightside and are subsequently transported onto the western side of KELT-1b’s dayside hemisphere before breaking up.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving and Assessing Planet Sensitivity of the GPI Exoplanet Survey with a Forward Model Matched Filter

We present a new matched-filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar point-spread function (PSF) is first subtracted using a Karhunen-Loéve image processing (KLIP) algorithm with angular and spectral differential imaging (ADI and SDI). The KLIP-induced distortion of the astrophysical signal is included in the matched-filter template by computing a forward model of the PSF at every position in the image. To optimize the performance of the algorithm, we conduct extensive planet injection and recovery tests and tune the exoplanet spectra template and KLIP reduction aggressiveness to maximize the signal-to-noise ratio (S/N) of the recovered planets. We show that only two spectral templates are necessary to recover any young Jovian exoplanets with minimal S/N loss. We also developed a complete pipeline for the automated detection of point-source candidates, the calculation of receiver operating characteristics (ROC), contrast curves based on false positives, and completeness contours. We process in a uniform manner more than 330 data sets from the Gemini Planet Imager Exoplanet Survey and assess GPI typical sensitivity as a function of the star and the hypothetical companion spectral type. This work allows for the first time a comparison of different detection algorithms at a survey scale accounting for both planet completeness and false-positive rate. We show that the new forward model matched filter allows the detection of 50% fainter objects than a conventional cross-correlation technique with a Gaussian PSF template for the same false-positive rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations on the DE 1 spacecraft of ELF/VLF waves generated by an ionospheric heater

DE 1 satellite radio observations were conducted in the 1525-5925 Hz range during a pass over an ionospheric heating facility; the waves were detected during a 2-min period, and the measurements indicated pulse-stretching by a few hundred msec, in conjunction with spectral broadening of about 10 Hz. The observed signal delays and pulse distortion are not consistent with expectations assuming propagation in a smooth magnetosphere between the assumed 'polar electrojet antenna' in the ionospheric D/E region and the 11,000-km altitude of the satellite. Scattering by density irregularities is judged the likely sources of the spectral broadening and delays.

James, H. G.↗

Can MARSIS Measure the Low-Altitude Components of the Mars Magnetic Field?

Measuring the magnetic field anomaly of Mars at low altitudes (e.g. 100-200 km) can be an interesting application of Mars Advance Radar for Subsurface and Ionospheric Sounder (MARSIS). Due to a low HF operation frequency, the radio wave propagating in the ionosphere of Mars, over the magnetic anomaly regions, will be affected and distorted by the localized magnetic field. This distortion in the sounder signal is due to the Faraday rotation and provides information about the strength of the magnetic field. MARSIS is especially sensitive to the radial magnetic field at altitudes where the electron density in the ionosphere peaks (i.e. 100-200 km). Consequently, MARSIS is potentially capable of providing measurements for the radial component of the magnetic field at altitudes between 100 to 200 km that are normally out of reach for orbital magnetometers (with the exception of the aero-braking phase). Such low-altitude measurements would be complementary to already existing measurements at 400 km by MAG-ER on Mars Global Surveyor. This paper will explain the sensitivity of MARSIS as a magnetometer and the method envisioned to measure the radial magnetic field component. MARSIS (Picardi et al.), the first major planetary radar sounder, is the result of an international collaboration between NASA, the Italian Space Agency (ASI), and European Space Agency (ESA), and will arrive at Mars in early 2004 for a two-year mission. MARSIS has a frequency range between 0.1-5.5 MHz and is designed to penetrate the subsurface to a depth of a few kilometers. MARSIS primary objective is to map and characterize the subsurface geological structure of Mars, and search for subsurface liquid water reservoirs. The secondary objective of MARSIS is to study the ionosphere of Mars providing the most extensive amount of data on Martian ionosphere to date. In addition to MARSIS, a second radar sounder named SHARAD (SHallow RADar) with operation frequency of 15-25 MHz is under development. SHARAD is an Italian instrument (Seu et. al) that will fly on NASA s Mars Reconnaissance orbiter in 2005. SHARAD can also provide magnetic measurements, however, it is not expected to be as sensitive as MARSIS to magnetic field variations.

A Safaeinili↗

COLUTA: Custom 8-Channel 15-bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The stringent radiation-tolerance, quantization requirements, and the need for seamless integration of the on-detector readout electronics chain require the design of a full-custom analog-to-digital converter (ADC) for the 182,468 channels in the ATLAS Liquid Argon (LAr) calorimeter at the Large Hadron Collider (LHC) at CERN, as part of the High-Luminosity LHC (HL-LHC) upgrade. Each of the 8 channels in the prototype 65 nm CMOS ADC with 15-bit resolution and >68 dB signal-to-noise-and-distortion ratio (SNDR), or equivalently >11 effective number of bits (ENOB), consists of a Multiplying-DAC (MDAC) and a successive-approximation (SAR) ADC. A digital data processing unit (DDPU) calibrates and serially transmits the quantized data. Initial lab characterization of 18 chips shows a minimum SNDR of 69.5 dB at full-scale at about 5 MHz and a maximum power consumption of 1.17 W; differential non-linearity (DNL) measurements show no missing codes. Additional validation of the ADC is ongoing before approximately 70k chips can be mass-produced for the upgrade.

Rui Xu↗

Radar transmit bandwidth augmentation

Various technologies pertaining to forming a very high instantaneous bandwidth (IBW) radar signal based upon several radio frequency (RF) signals that have sub-bands of the frequency band of the radar signal are described herein. A radar system is configured to address local oscillator leakage across multiple transmit channels of the radar system, such that the radar signal has a relatively constant or other desired amplitude and phase across frequencies of the radar signal. In addition, the radar system is configured to compute a correction signal that pre-distorts each of the sub-frequency channels such that upon combining enables the generation of desired amplitude and phase response across a transmitted pulse.

Loui, Hung↗

Measurement of space charge effects in the MicroBooNE LArTPC using cosmic muons

Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in the detector primarily due to ionization from cosmic rays, leading to a distortion of the electric field within the detector. This effect leads to a displacement in the reconstructed position of signal ionization electrons in LArTPC detectors ("spatial distortions"), as well as to variations in the amount of electron-ion recombination experienced by ionization throughout the volume of the TPC. We present techniques that can be used to measure and correct for space charge effects in large LArTPCs by making use of cosmic muons, including the use of track pairs to unambiguously pin down spatial distortions in three dimensions. Finally, the performance of these calibration techniques are studied using both Monte Carlo simulation and MicroBooNE data, utilizing a UV laser system as a means to estimate the systematic bias associated with the calibration methodology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of transponder imperfections on the error probability performance of a satellite communication system

The bit error rate (BER) performance analysis of a data communication system is generally based on the assumption that signal waveforms are ideal and hardware-induced distortion is absent. In a satellite communication system such distortion arises in the satellite transponder, as well as in the transmitter and receiver portions. NASA, which is in the process of developing its Tracking and Data Relay Satellite System (TDRSS), is very much interested in understanding the impact of numerous forms of hardware distortion that have been identified on BER performance. The present paper examines the cumulative impact of nine forms of distortion induced by the transponder on BPSK and QPSK signals. For the present analysis, the transmitter and receiver are assumed to operate in essentially ideal fashions. Computed results indicate that BPSK and QPSK performances are affected in substantially different manners, with QPSK generally more sensitive to a given form of distortion. Cumulative distortion effects are illustrated via computed performance curves.

Weinberg, A.↗