Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Crystallographically uniform arrays of ordered (In)GaN nanocolumns

In this work, through a comparative study of self-assembled (SA) and selective area grown (SAG) (In)GaN nanocolumn (NC) ensembles, we first give a detailed insight into improved crystallographic uniformity (homogeneity of crystallographic tilts and twists) of the latter ones. The study, performed making use of: reflective high energy electron diffraction, X-ray diffraction and scanning electron microscopy, reveals that unlike their SA counterparts, the ensembles of SAG NCs show single epitaxial relationship to both sapphire(0001) and Si(111) underlying substrates. In the second part of the article, making use of X-ray diffraction, we directly show that the selective area growth leads to improved compositional uniformity of InGaN NC ensembles. This further leads to improved spectral purity of their luminescence, as confirmed by comparative macro-photoluminescence measurements performed on SA and SAG InGaN NC ensembles. An improved crystallographic uniformity of NC ensembles facilitates their integration into optoelectronic devices, whereas their improved compositional uniformity allows for their employment in single-color optoelectronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphene engineering by neon ion beams

Achieving the ultimate limits of materials and device performance necessitates the engineering of matter with atomic, molecular, and mesoscale fidelity. While common for organic and macromolecular chemistry, these capabilities are virtually absent for 2D materials. In contrast to the undesired effect of ion implantation from focused ion beam (FIB) lithography with gallium ions, and proximity effects in standard e-beam lithography techniques, the shorter mean free path and interaction volumes of helium and neon ions offer a new route for clean, resist free nanofabrication. Furthermore, with the advent of scanning helium ion microscopy, maskless He + and Ne + beam lithography of graphene based nanoelectronics is coming to the forefront. Here, we will discuss the use of energetic Ne ions in engineering graphene devices and explore the mechanical, electromechanical and chemical properties of the ion-milled devices using scanning probe microscopy (SPM). By using SPM-based techniques such as band excitation (BE) force modulation microscopy, Kelvin probe force microscopy (KPFM) and Raman spectroscopy, we demonstrate that the mechanical, electrical and optical properties of the exact same devices can be quantitatively extracted. Additionally, the effect of defects inherent in ion beam direct-write lithography, on the overall performance of the fabricated devices is elucidated.

36 MATERIALS SCIENCE↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In their experience, these strategies provide robust, high fidelity, high contrast MR images suitable for external beam RTP.

60 APPLIED LIFE SCIENCES↗

Quantification of Dopant Profiles in SiGe HBT Devices

We report on the use of atom probe tomography (APT), scanning transmission electron microscopy (STEM), and secondary ion mass spectroscopy (SIMS) to characterize doping profiles in the base region of SiGe HBT devices. We compare SIMS profiles obtained from large regions (400 um 2 ) of the device wafer to profiles obtained from individual devices of different emitter window widths (0.25 and 0.18 um 2 ) using APT. From this comparison we show how APT can provide a deeper insight into evaluating the fabrication process and its effects on electrical models of device performance and enabling the building of higher performance systems. We also demonstrate that APT can be used to characterize defects within the intrinsic regions of a device.

Jones, Eric↗

Contracting cardiomyocytes in hydrophobic room-temperature ionic liquid

Highlights: Black-Right-Pointing-Pointer Biocompatible room-temperature ionic liquid was applied on beating cardiomyocyte. Black-Right-Pointing-Pointer The lifetime of beating cardiomyocytes was depended on anion functional group. Black-Right-Pointing-Pointer A longer lifetime was recorded for no functional group on alkyl chain on their anion. Black-Right-Pointing-Pointer Amino group on alkyl chain and fluorine in anion induced fatal condition changes. Black-Right-Pointing-Pointer We reported liquid electrolyte interface to stimulate cardiomyocytes. -- Abstract: Room-temperature ionic liquids (RTILs) are drawing attention as a new class of nonaqueous solvents to replace organic and aqueous solvents for chemical processes in the liquid phase at room temperature. The RTILs are notable for their characteristics of nonvolatility, extremely low vapor pressure, electric conductivity, and incombustibility. These distinguished properties of RTILs have brought attention to them in applications with biological cells and tissue in vacuum environment for scanning electron microscopy, and in microfluidic devices for micro-total analysis system (micro-TAS). Habitable RTILs could increase capability of nonaqueous micro-TAS for living cells. Some RTILs seemed to have the capability to replace water in biological applications. However, these RTILs had been applied to just supplemental additives for biocompatible test, to fixed cells as a substitute for an aqueous solution, and to simple molecules. None of RTILs in which directly soaks a living cell culture. Therefore, we demonstrated the design of RTILs for a living cell culture and a liquid electrolyte to stimulate contracting cardiomyocytes using the RTILs. We assessed the effect of RTILs on the cardiomyocytes using the beating lifetime to compare the applicability of RTILs for biological applications. Frequent spontaneous contractions of cardiomyocytes were confirmed in amino acid anion RTILs [P{sub 8,8,8,8}][Leu] and [P{sub 8,8,8,8}][Ala], phosphoric acid derivatives [P{sub 8,8,8,8}][MeO(H)PO{sub 2}], and [P{sub 8,8,8,8}][C{sub 7}CO{sub 2}]. The anion type of RTILs had influence on applicable characteristics for the contracting cardiomyocyte. This result suggested the possibility for biocompatible design of hydrophobic group RTILs to achieve biological applications with living cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence and Nonlinear Optical Properties of Alizarin Red S in Solvents and Droplet

The enhancement of the nonlinear properties of materials is an interesting topic since it has many applications in optical devices and medicines. The Z-scan technique was used to study the values of the two-photon absorption (β), second-order molecular hyperpolarizability (γ{sub R}), third-order susceptibility (χ{sub R}), and nonlinear refractive index (n{sub 2}) of Alizarin Red S in different media using a continuous-wave diode-pump laser radiation at 532 nm. For Alizarin Red S in a droplet, the β, n{sub 2}, χ{sub R,} and γ{sub R} were estimated at the order of 10{sup −7} cm{sup 2}/W and 10{sup −12} cm/W, 10{sup −3} m{sup 3} W{sup −1} s{sup −1} and 10{sup −24} m{sup 6} W{sup −1} s{sup −1}, respectively. The results indicated that the values of β and n{sub 2} reduced, whereas the values of χ{sub R} and γ{sub R} were enhanced when the solvent was changed from droplet to water, DMF, and dimethyl sulfoxide due to the change in the solvent’s dielectric constant (ε). Moreover, the values of β were enhanced by an increase in the concentration of the surfactant in the aqueous solution. The absorption spectra of Alizarin Red S in the aqueous solution was observed at 428 nm, and a few red shifts in the absorption spectra were observed with a reduction in the dielectric constant of the medium. The same effect was observed in the absorption spectra of Alizarin Red S in the droplet when the bulk dielectric constant reduced. The dielectric constant can affect the fluorescence spectra of Alizarin Red S when the solution is changed from water to dimethyl sulfoxide. The dipole moments of Alizarin Red S in the different media were studied using the quantum perturbation theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Impact of the electron density and temperature gradient on drift-wave turbulence in the Large Plasma Device

In this paper we present an experimental study of edge turbulence in the Large Plasma Device at UCLA. We utilize a scan of discharge power and prefill pressure (neutral density) to show experimentally that turbulent density fluctuations decrease with decreasing density gradient, as predicted for resistive drift-wave turbulence (RDWT). As expected for RDWT, we observe that the cross-phase between the density and potential fluctuations is close to 0. Moreover, the addition of an electron temperature gradient leads to a reduction in the amplitude of the density fluctuations, as expected for RDWT. However, counter to theoretical expectations, we find that the potential fluctuations do not follow the same trends as the density fluctuations for changes either in density gradients or the addition of a temperature gradient. The disconnect between the density and potential fluctuations is connected to changes in the parallel flows as a result of differences in the prefill pressure, i.e. neutral density. Further analysis of the density and potential fluctuation spectra show that the electron temperature gradient reduces the low frequency fluctuations up to $10 \,{\rm kHz}$ and the introduction of a temperature gradient leads to an unexpected ${\sim }{\rm \pi}$ shift of the density–potential cross-phase at ${\sim }10\,{\rm kHz}$ , while maintaining the typical resistive drift-wave cross-phase at lower frequencies. These experiments partly confirm existing knowledge on resistive drift-wave turbulence, but also introduce new observations that indicate a need for dedicated nonlinear three-dimensional turbulence simulations that include neutrals.

Physics↗

Pervasive liquid metal based direct writing electronics with roller-ball pen

A roller-ball pen enabled direct writing electronics via room temperature liquid metal ink was proposed. With the rolling to print mechanism, the metallic inks were smoothly written on flexible polymer substrate to form conductive tracks and electronic devices. The contact angle analyzer and scanning electron microscope were implemented to disclose several unique inner properties of the obtained electronics. An ever high writing resolution with line width and thickness as 200 μm and 80 μm, respectively was realized. Further, with the administration of external writing pressure, GaIn{sub 24.5} droplets embody increasing wettability on polymer which demonstrates the pervasive adaptability of the roller-ball pen electronics.

36 MATERIALS SCIENCE↗

Direct imaging of enhanced current collection on grain boundaries of Cu(In,Ga)Se{sub 2} solar cells

We report on direct imaging of current collection by performing conductive atomic force microscopy (C-AFM) measurement on a complete Cu(In,Ga)Se{sub 2} solar cell. The localized current was imaged by milling away the top conductive layer of the device by repeated C-AFM scans. The result exhibits enhanced photocurrent collection on grain boundaries (GBs) of CIGS films, consistent with the argument for electric-field-assisted carrier collection on the GBs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toxicity evaluation of ZnO nanostructures on L929 fibroblast cell line using MTS assay

ZnO has wide applications in medical and dentistry apart from being used as optoelectronic devices such as solar cells, photodetectors, sensors and light emitting diodes (LEDs). Therefore, the toxicity evaluation is important to know the toxicity level on normal cell line. The toxicity of two grades ZnO nanostructures, ZnO-4 and ZnO-8 have been carried out using cytotoxicity test of MTS assay on L929 rat fibroblast cell line. Prior to that, ZnO-4 and ZnO-8 were characterized for its morphology, structure and optical properties using FESEM, X-ray diffraction, and Photoluminescence respectively. The two groups revealed difference in morphology and exhibit slightly shifted of near band edge emission of Photoluminescence other than having a similar calculated crystallite size of nanostructures. The viability of cells after 72h were obtained and the statistical significance value was calculated using SPSS v20. The p value is more than 0.05 between untreated and treated cell with ZnO. This insignificant value of p>0.05 can be summarized as a non-toxic level of ZnO-4 and ZnO-8 on the L929 cell line.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stability and transport of gyrokinetic critical pedestals

Abstract A gyrokinetic threshold model for pedestal width–height scaling prediction is applied to multiple devices. A shaping and aspect ratio scan is performed on National Spherical Torus Experiment (NSTX) equilibria, finding Δ ped = 0.92 A 1.04 κ − 1.24 0.38 δ β θ , ped 1.05 for the wide-pedestal branch with pedestal width Δ ped , aspect ratio A , elongation κ , triangularity δ , and normalized pedestal height β θ , ped . The width–transport scaling is found to vary significantly if the pedestal height is varied either with a fixed density or fixed temperature, showing how fueling and heating sources affect the pedestal density and temperature profiles for the kinetic-ballooning-mode (KBM) limited profiles. For an NSTX equilibrium, at fixed density, the wide branch is Δ ped = 0.028 ( q e / Γ e − 1.7 ) 1.5 ∼ η e 1.5 and at fixed temperature Δ ped = 0.31 ( q e / Γ e − 4.7 ) 0.85 ∼ η e 0.85 , where q e and Γ e are turbulent electron heat and particle fluxes and η e = ∇ ln ⁡ T e / ∇ ln ⁡ n e for an electron temperature T e and density n e . Pedestals close to the KBM limit are shown to have modified turbulent transport coefficients compared to the strongly driven KBMs. The role of flow shear is studied as a width–height scaling constraint and pedestal saturation mechanism for a standard and lithiated wide pedestal discharge. Finally, the stability, transport, and flow shear constraints are combined and examined for an NSTX experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Graphene metamaterial modulator for free-space thermal radiation

We proposed and demonstrated a new metamaterial architecture capable of high speed modulation of free-space space thermal infrared radiation using graphene. Our design completely eliminates channel resistance, thereby maximizing the electrostatic modulation speed, while at the same time effectively modulating infrared radiation. Experiment results verify that our device with area of 100 × 120 µm 2 can achieve a modulation speed as high as 2.6 GHz. We further highlight the utility of our graphene metamaterial modulator by reconstructing a fast infrared signal using an equivalent time sampling technique. The graphene metamaterial modulator demonstrated here is not only limited to the thermal infrared, but may be scaled to longer infrared and terahertz wavelengths. Our work provides a path forward for realization of frequency selective and all-electronic high speed devices for infrared applications.

36 MATERIALS SCIENCE↗

Instrumentation and Equipment for Three Independent Research Labs

Completed in 2011, Albright's new Science Center includes three independent student and faculty research labs in Biology, Chemistry/Biochemistry, and Physics (separate from teaching labs). Providing independent research facilities, they eliminate disruptions in classrooms and teaching labs, encourage and accommodate increased student interest, and stimulate advanced research. The DOE grant of $369,943 enabled Albright to equip these advanced labs for 21st century science research, with much instrumentation shared among departments. The specialty labs will enable Albright to expand its student-faculty research program to meet growing interest, help attract superior science students, maximize faculty expertise, and continue exceeding its already high rates of acceptance for students applying for postgraduate education or pharmaceutical research positions. Biology instrumentation/equipment supports coursework and independent and collaborative research by students and faculty. The digital shaker, CO 2 and water bath incubators (for controlled cell growth), balance, and micropipettes support cellular biology research in the advanced cell biology course and student-faculty research into heavy metal induction of heat shock proteins in cultured mammalian cells and the development of PCR markers from different populations of the native tree, Franklinia. The gravity convection oven and lyophilizer support research into physical and chemical analysis of floodplain sediments used in assessment of riparian restoration efforts. The Bio-Rad thermocycler permits fast and accurate DNA amplification as part of research into genetic diversity in small mammal populations and how those populations are affected by land-use practices and environmental management. The Millipore water deionizing system and glassware washer provide general support of the independent research lab and ensure quality control of coursework and interdisciplinary research at the intersection of biology, chemistry, and toxicology. Grant purchases support faculty and students working in the areas of plant cellular biology, landscape ecology and wildlife management, wetland restoration, and ecotoxicology of aquatic invertebrates. Chemistry/BioChemistry instrumentation supports a wide range of research and teaching needs. The Dell quad core Xeon processors and Gaussian 09 support computational research efforts of two of our faculty. The computational work of one of these groups is part of close collaboration with one organic chemist and provides support info for the synthetic work of this professor and his students. Computational chemistry studies were also introduced into the physical chemistry laboratory course for junior chemistry concentrators. The AKTA plus system and superdex columns, Thermoscientific Sorvall RC-6 plus superspeed centrifuge, Nanodrop spectrometer, Eppendorf microfuge, Homogenizer and Pipetman pipetters were incorporated into a research project involving purification and characterization of a construct of beta 2-microglobulin by one of our biochemists. The vacuum system (glove box, stand, and pump) makes a significant contribution to the research of our inorganic chemist, the newest department member, working on research projects with four students. The glove box provides the means to carry out their synthetic work in an oxygenless atmosphere. Supporting basic research pursued by faculty and students, the remaining items (refrigerator/freezer units for flammable storage, freezer, refrigerated water bath, rotary evaporator system, vacuum oven, analytical and top-loading balances) were distributed between our biochemistry and chemistry research labs. The Nanodrop spectrometer, Sorvall centrifuge, and rotary evaporator system are used in several junior/senior lab courses in both biochemistry and chemistry. To date, 14 undergraduate research students have been involved in projects using the new instrumentation and equipment provided by this grant. Physics equipment acquired is radically transforming Albright research and teaching capabilities. The two main purchases are an atomic force microscope (AFM) and a scanning tunneling microscope (STM). These two devices allow us to view surfaces at much higher resolution than ever before, even to the level of individual atoms. Already the AFM has been incorporated into courses for advanced physics and biology students, allowing them to view at high resolution material such as carbon nanotubes, cell structure, and proteins. These devices offer possibilities for interdisciplinary collaboration among students and faculty in various departments that have barely begun to be tapped. Additional equipment, such as software, optical tables, lasers, and other support equipment, is also strengthening our research and teaching capabilities in optics-related areas.

99 GENERAL AND MISCELLANEOUS↗

Scrape-off layer transport and filament characteristics in high-density tokamak regimes

A detailed cross-device investigation on the role of filamentary dynamics in high-density regimes has been performed within the EUROfusion framework, comparing the ASDEX Upgrade (AUG) and TCV tokamaks. Both devices run density ramp experiments at different levels of plasma current, keeping the toroidal field or q 95 constant in order to disentangle the role of the parallel connection length and the current. During the scan at a constant toroidal field, in both devices the scrape-off layer (SOL) profiles tend to develop a clear SOL density shoulder at a lower edge density whenever the current is reduced. Different current behaviour is substantially reconciled in terms of the edge density normalized to the Greenwald fraction. During the scan at constant q 95 AUG exhibits similar behaviour, whereas in TCV no upstream profile modification signature has been observed at lower current levels. The latter behaviour has been ascribed to the lack of target density rollover. In this work, the relation between the upstream density profile modification and detachment condition has been investigated. For both devices the relation between blob size and the SOL density e-folding length is found independent of the plasma current, with the observation of a clear increase in blob size and the edge density normalized to a Greenwald fraction. ASDEX Upgrade has also explored filamentary behaviour in the H-mode. The experiments in AUG have focused on the role of neutrals, performing discharges with and without cryogenic pumps, highlighting how high neutral pressure, not only in the divertor but also at the midplane, is needed in order to develop an H-mode SOL profile shoulder in AUG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and structure of alpha-Ta films for quantum circuit integration

Tantalum films incorporated into superconducting circuits have exhibited low surface losses, resulting in long-lived qubit states. The remaining loss pathways originate in microscopic defects that manifest as two level systems (TLSs) at low temperatures. These defects limit performance, so careful attention to tantalum film structures is critical for optimal use in quantum devices. In this work, we investigate the growth of tantalum using magnetron sputtering on sapphire, Si, and photoresist substrates. In the case of sapphire, we present procedures for the growth of fully-oriented films with α-Ta [1 1 1]//Al2O3 [0 0 0 1] and α-Ta [1 −1 0]//Al2O3 [1 0 −1 0] orientational relationships and having residual resistivity ratio (RRR) ∼ 60 for 220 nm thick films. On Si, we find a complex grain texturing with Ta [1 1 0] normal to the substrate and RRR ∼ 30. We further demonstrate airbridge fabrication using Nb to nucleate α-Ta on photoresist surfaces. For the films on sapphire, resonators show TLS-limited quality factors of 1.3 ± 0.3 × 106 at 10 mK (for a waveguide gap and conductor width of 3 and 6 μm, respectively). Structural characterization using scanning electron microscopy, x-ray diffraction, low temperature transport, secondary ion mass spectrometry, and transmission electron microscopy reveal the dependence of residual impurities and screw dislocation density on processing conditions. The results provide practical insights into the fabrication of advanced superconducting devices including qubit arrays and guide future works on crystallographically deterministic qubit fabrication.

42 ENGINEERING↗

Electrolytic gold plating, stripping, and ion transport dynamics through a solid-state iodide perovskite

The pronounced electrochemical reactivity between halide perovskites and metal electrodes can introduce mobile extrinsic metal ions which can cause device instability or enable novel functionalities. Here we systematically investigate the kinetics of gold cation (Au + ) migration in indium tin oxide (ITO)/methylammonium lead triiodide (MAPbI 3 )/Au model devices under long-term potentiostatic biasing. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) analyses reveal that Au + ions, electrochemically generated at the Au anode, traverse the perovskite layer with diffusion coefficients on the order of 10 −11 to 10 −10 cm 2 s −1 and are subsequently reduced at the cathode as Au 0 clusters, resembling metal plating behavior in electrolytic cells and solid-state batteries during charging. Furthermore, reversing the applied bias strips the plated Au 0 , revealing reversibility suitable for bipolar resistive switching devices and providing direct evidence of the electrochemical and ionic nature of Au transport within the perovskite matrix. Quantitatively determining diffusion coefficients and ion concentrations provides foundational inputs for future drift-diffusion modelling opportunities and allows us to relate our findings to implications on long term operation of devices like photovoltaic modules. These results clearly demonstrate the solid-state electrochemical nature of perovskite devices, highlight methods to be more quantitative about ion transport properties, provide and emphasize the importance of disentangling electro-, photo-, photoelectrochemical processes for understanding device performance and unlocking new functionalities.

14 SOLAR ENERGY↗

Nanophotonic waveguide chip-to-world beam scanning

A seamless chip-to-world photonic interface enables broad advancements in optical ranging, display, communication, computation and quantum information science. The ideal solution enables two-dimensional scanning of a diffraction-limited beam from anywhere on a photonic integrated circuit to a large number of resolvable spots. Current beam-scanning technologies are limited by a fundamental trade-off: photonic-integrated-circuits with diffractive optics offer scalability but have poor mode quality, whereas inertially limited micromechanical scanners provide high-quality beams but lack scalable integration. Here we report a photonic ski-jump—a nanoscale waveguide monolithically integrated on a piezoelectric cantilever—to overcome these limitations. It passively curls ~90° out-of-plane within a less-than-0.1 mm 2 footprint, emits a submicrometre, broadband diffraction-limited beam, and exhibits kilohertz-rate mechanical resonances with quality factors of over 10,000. Fabricated in a volume complementary metal–oxide–semiconductor (CMOS) foundry, our device enables scalable two-dimensional beam scanning. Driven on-resonance at CMOS-level voltages, it achieves a footprint-adjusted spot rate of 68.6 mega spots s –1 mm–², exceeding state-of-the-art micro-electro-mechanical systems mirrors by more than 50-fold, which is sufficient for one million pixels at 100 Hz from an approximately 1.5 mm diameter footprint. We demonstrate full-colour image and video projection, and single-photon initialization and readout from silicon vacancy centres in diamond. Finally, by demonstrating uniformity across a 64 ski-jump array, we establish a pathway to achieving greater than one gigaspot resolution at kilohertz rates within a sub-5-cm-diameter footprint, creating a seamless optical pipeline between integrated photonic processors and the free-space world.

Displays↗