Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

The Technique of Studying X-Ray Scattering over Wide Temperature Range in an Electric Field

The technique of studying the synchrotron radiation scattering on single crystals over wide temperature range using an original miniature device for applying an electric field to a sample is described. A specific feature of the device is the possibility of its application with various heating and cooling systems. The technique was used at BM01 beamline at the European Synchrotron Radiation Facility (ESRF) for the study of the influence of electric field on the processes of structural transformation in lead zirconate–titanate single crystal with a low titanium concentration. The efficiency of the technique proposed in this work is demonstrated and the results of the preliminary analysis of the results are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Density of NaAlSi 2 O 6 Melt at High Pressure and Temperature Measured by In-Situ X-ray Microtomography

In this study, the volumetric compression of jadeite (NaAlSi 2 O 6 ) melt at high pressures was determined by three-dimensional volume imaging using the synchrotron-based X-ray microtomography technique in a rotation-anvil device. Combined with the sample mass, measured using a high-precision analytical balance prior to the high-pressure experiment, the density of jadeite melt was obtained at high pressures and high temperatures up to 4.8 GPa and 1955 K. The density data were fitted to a third-order Birch-Murnaghan equation of state, resulting in a best-fit isothermal bulk modulus K T0 of $10.8$ $^{+1.9}_{–5.3}$ GPa and its pressure derivative K' T0 of $3.4$ $^{+6.6}_{–0.4}$. Comparison with data for silicate melts of various compositions from the literature shows that alkali-rich, polymerized melts are generally more compressible than alkali-poor, depolymerized ones. The high compressibility of jadeite melt at high pressures implies that polymerized sodium aluminosilicate melts, if generated by low-degree partial melting of mantle peridotite at ~250–400 km depth in the deep upper mantle, are likely denser than surrounding mantle materials, and thus gravitationally stable.

36 MATERIALS SCIENCE↗

Analysis of Surface Chemistry and Detector Performance of Chemically Process CdZnTe crystals

The goal is to produce non-conductive smooth surfaces for fabricating low-noise and high-efficiency CdZnTe devices for gamma spectroscopy. Sample preparation and results are discussed. The researachers demonstrated various bulk defects (e.g., dislocations and sub-grain boundaries) and surface defects, and examined their effects on the performance of detectors. A comparison study was made between two chemical etchants to produce non-conductive smooth surfaces. A mixture of bromine and hydrogen peroxide proved more effective than conventional bromine etchant. Both energy resolution and detection efficiency of CZT planar detectors were noticeably increased after processing the detector crystals using improved chemical etchant and processing methods.

36 MATERIALS SCIENCE↗

Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

Tailoring the optical properties of wide-bandgap based microcavities via metal films

We report on the tuning of the optical properties of II-VI-material-based microcavity samples, which is achieved by depositing Ag films on top of the structures. The micro-reflectivity spectra show a spectral shift of the sample resonance dependent on the metal layer thickness. By comparison of the experimental findings with the theoretical calculations applying the transfer matrix method on a metal-dielectric mirror structure, the influence of the metal layer particularly with regard to its partial oxidation was explored. Tamm plasmon modes are created at the interface between an open cavity with three ZnSe quantum wells and a metal layer on top. When tuning the excitonic emission relative to the mode by changing the sample temperature, an anticrossing of the resonances was observed. This is a clear indication that the strong coupling regime has been achieved in that sample configuration yielding a Rabi splitting of 18.5 meV. These results are promising for the realization of polariton-based optical devices with a rather simple sample configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Percutaneous ureteral biopsy: safety and diagnostic yield

Purpose: To evaluate safety and diagnostic yield of percutaneous CT-guided biopsy of extrarenal upper urinary tract lesions. Materials and methods: Retrospective review of our institutional database of image-guided biopsies yielded 44 CT-guided percutaneous biopsies in 44 unique patients that targeted ureteral (30, 68%) or other non-renal upper urinary tract lesions (14, 32%) between January 1, 2000 and May 1, 2017. Indications, pre-biopsy imaging, biopsy technique, peri-procedural antithrombotic use, complications including bleeding defined by Society of Interventional Radiology criteria, pathology results, and subsequent imaging were reviewed up to 3 months after the procedure to evaluate safety and diagnostic yield. Results: Mean patient age was 66 (range 27–88) and 23/44 patients were male. The majority (34/44) of lesions were sampled with an 18-gauge biopsy device via a 17-gauge introducer needle, and the remaining 10/44 lesions were sampled with a 19/20 gauge system. The mean number of core samples obtained was 4 (range 2–10). No major complications occurred. Specifically, no patient developed a urine leak or urinary obstruction. Minor complications occurred in 3/44 (7%) biopsies, all retroperitoneal hemorrhages that did not require transfusion or other intervention. Biopsy was adequate for pathologic examination in 41 of 44 (93%) cases. Among patients undergoing surgical resection, biopsy diagnosis was concordant with surgical pathology in 9/10 (90%) cases and discordant in 1/10 (10%). Conclusion: CT-guided percutaneous biopsy of upper urinary tract lesions can be performed safely, with high diagnostic yield, and with a high rate of concordance on subsequent surgical pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy efficient spark plasma sintering: Breaking the threshold of large dimension tooling energy consumption

An energy efficient spark plasma sintering method enabling the densification of large size samples assisted by very low electric current levels is developed. In this method, the electric current is concentrated in the graphite foils around the sample. High-energy dissipation is then achieved in this area enabling the heating and full densification of large (alumina) parts (Ø 40 mm) at relatively low currents (800 A). The electrothermal mechanical simulation reveals that the electric current needed to heat the large samples is 70% lower in the energy efficient configuration compared to the traditional configuration. The presence of thermal and densification gradients is also revealed for the larger size samples. Potential solutions for this problem are discussed. The experiments confirm the possibility of full densification (96%-99%) of large alumina samples. This approach allows using small (and low cost) SPS devices (generally limited to 10-15 mm samples) for large-size samples (40-50 mm). Finally, the developed technique enables also an optimized energy consumption by large-scale SPS systems.

36 MATERIALS SCIENCE↗

Critical Interface: Poly-Silicon to Tunneling SiO2 for Passivated Contact Performance

Environmental exposure of our thin tunneling SiO2 layer on nCz wafer samples prior to poly-Silicon (poly-Si) deposition critically impacts the resulting contact passivation. We present ToF-SIMS evidence of SiO2 oxide storage-induced degradation, presumably by surface contaminants such as carbon, in symmetric and device poly-Si/SiO2 lifetime samples as well as in finished cells. We also present methods to resurrect a contaminated SiO2 layer, including UV-O3 treatment prior to passivated contact formation to produce >21% TCO-free solar cells.

14 SOLAR ENERGY↗

A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic tunnel junction random number generators applied to dynamically tuned probability trees driven by spin orbit torque

Abstract Perpendicular magnetic tunnel junction (pMTJ)-based true-random number generators (RNGs) can consume orders of magnitude less energy per bit than CMOS pseudo-RNGs. Here, we numerically investigate with a macrospin Landau–Lifshitz-Gilbert equation solver the use of pMTJs driven by spin–orbit torque to directly sample numbers from arbitrary probability distributions with the help of a tunable probability tree. The tree operates by dynamically biasing sequences of pMTJ relaxation events, called ‘coinflips’, via an additional applied spin-transfer-torque current. Specifically, using a single, ideal pMTJ device we successfully draw integer samples on the interval [0, 255] from an exponential distribution based on p -value distribution analysis. In order to investigate device-to-device variations, the thermal stability of the pMTJs are varied based on manufactured device data. It is found that while repeatedly using a varied device inhibits ability to recover the probability distribution, the device variations average out when considering the entire set of devices as a ‘bucket’ to agnostically draw random numbers from. Further, it is noted that the device variations most significantly impact the highest level of the probability tree, with diminishing errors at lower levels. The devices are then used to draw both uniformly and exponentially distributed numbers for the Monte Carlo computation of a problem from particle transport, showing excellent data fit with the analytical solution. Finally, the devices are benchmarked against CMOS and memristor RNGs, showing faster bit generation and significantly lower energy use.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

2011 Atlanta, Georgia, Regional Travel Survey

The 2011 Regional Travel Survey collected trip data from households across 20 counties in and around Atlanta, Georgia, to improve regional travel demand forecasts. The survey was conducted by PTV NuStats, GeoStats, and PG Americas Inc. on behalf of the Atlanta Regional Commission. The goal was to collect trip data from a minimum of 10,000 households with a subsample of 1,000 households providing global positioning system (GPS) data. The GPS add-on consisted of two sample groups. The first sample group was provided with GPS devices to install in their personal vehicles (797 vehicles) to collect the speed and location of a vehicle during an assigned study period. The second sample group (1,653 participants) was provided with a wearable GPS device to collect the speed and location of an individual during an assigned study period. People participating in the wearable add-on part of the study were chosen because their travel diaries reported use of public transit in day-to-day travel. Each GPS participant was grouped into either the spring phase (March to May 2011) or the fall phase (July to September 2011), and data were recorded for a maximum of seven days for vehicle units and three days for wearable units.

1Hz data↗

Hydrogel nanoparticle based immunoassay

An immunoassay device incorporating porous polymeric capture nanoparticles within either the sample collection vessel or pre-impregnated into a porous substratum within fluid flow path of the analytical device is presented. This incorporation of capture particles within the immunoassay device improves sensitivity while removing the requirement for pre-processing of samples prior to loading the immunoassay device. A preferred embodiment is coreshell bait containing capture nanoparticles which perform three functions in one step, in solution: a) molecular size sieving, b) target analyte sequestration and concentration, and c) protection from degradation. The polymeric matrix of the capture particles may be made of co-polymeric materials having a structural monomer and an affinity monomer, the affinity monomer having properties that attract the analyte to the capture particle. This device is useful for point of care diagnostic assays for biomedical applications and as field deployable assays for environmental, pathogen and chemical or biological threat identification.

47 OTHER INSTRUMENTATION↗

Optical spectroscopy system and method for monitoring liquid phase chemical reactions

A system for monitoring a chemical reaction in a liquid reactor system includes a sample liquid conduit in communication with the liquid reactor system for receiving sample liquid and directing the sample liquid to an optical spectroscopy device, and a laser beam source. The optical spectroscopy device receives the laser beam from the laser source, and guides the laser beam to the sample liquid to generate an optical spectroscopy signal. A detector detects the optical spectroscopy signal and creates a detection signal responsive to the optical spectroscopy signal. A processor processes the detection signal to determine the identity and amount of at least one chemical species in the liquid. A system for continuously sampling a chemical reaction and a method for continuously monitoring and controlling a chemical reaction are also disclosed.

Morales Rodriguez, Marissa E.↗

Structure-Driven Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. In conclusion, this novel, “structure-driven” sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (~4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗