Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Variable location channels to improve efficiency and precision for direct ∇ T e measurements and high spatial resolution T e -profile measurements using electron cyclotron emission

Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.

47 OTHER INSTRUMENTATION↗

Seismotectonic evidence for subduction beneath the Eastern Greater Caucasus

SUMMARY We generated high-resolution 3-D seismic velocity models as well as a relocated earthquake catalogue across the eastern Greater Caucasus and Kura basins. This work was done using data from the recently upgraded Republic Seismological Survey Center's (RSSC) seismic network. We generated our tomographic images of crustal velocity structure in Azerbaijan using double-difference inversions (i.e. tomoDD and hypoDD). Earthquake catalogues from the RSSC between 2011 and 2016 were used; these catalogues include absolute arrival times of 103 288 P- and 120 952 S-wave traveltime picks for 7574 events recorded at 35 stations in Azerbaijan. Beginning with a layered, 1-D velocity model that was estimated using VELEST, we inverted simultaneously for relative location, Vp and Vs on a 3-D grid with dimensions 670 × 445 × 45 km, with a uniform grid spacing of 55 × 55 × 5 km for all of Azerbaijan. We observe that the relocated hypocentres cluster into two depth ranges, at the surface and at depth, that appear to correspond to major fault zones and the top of a subducting plate. Additionally, we note intermediate depth seismicity (∼50–60 km) beneath the Kura Basin, and a northward deepening of earthquake depths. Seismic velocities vary significantly throughout the study region; we observe very slow velocities throughout the Kura Basin between 5 and 15 km, and elevated velocities at 20–35 km. The wholesale velocity structure and seismic structure of Kura Basin strongly mirrors that of the Caspian Sea, which suggests that the geodynamics of the Caspian continue westwards into Azerbaijan. The key results of this study suggest that the northward subduction observed in the Caspian Sea continues beneath the Eastern Greater Caucasus, as well as provides evidence for active faulting along the southern margin of the mountain range.

Gunnels, Michael↗

A small protein inhibits proliferating cell nuclear antigen by breaking the DNA clamp

Proliferating cell nuclear antigen (PCNA) forms a trimeric ring that encircles duplex DNA and acts as an anchor for a number of proteins involved in DNA metabolic processes. PCNA has two structurally similar domains (I and II) linked by a long loop (inter-domain connector loop, IDCL) on the outside of each monomer of the trimeric structure that makes up the DNA clamp. All proteins that bind to PCNA do so via a PCNA-interacting peptide (PIP) motif that binds near the IDCL. A small protein, called TIP, binds to PCNA and inhibits PCNA-dependent activities although it does not contain a canonical PIP motif. The X-ray crystal structure of TIP bound to PCNA reveals that TIP binds to the canonical PIP interaction site, but also extends beyond it through a helix that relocates the IDCL. TIP alters the relationship between domains I and II within the PCNA monomer such that the trimeric ring structure is broken, while the individual domains largely retain their native structure. Small angle X-ray scattering (SAXS) confirms the disruption of the PCNA trimer upon addition of the TIP protein in solution and together with the X-ray crystal data, provides a structural basis for the mechanism of PCNA inhibition by TIP.

59 BASIC BIOLOGICAL SCIENCES↗

Gravitropism of Arabidopsis thaliana Roots Requires the Polarization of PIN2 toward the Root Tip in Meristematic Cortical Cells

In the root, the transport of auxin from the tip to the elongation zone, referred to here as shootward, governs gravitropic bending. Shootward polar auxin transport, and hence gravitropism, depends on the polar deployment of the PIN-FORMED auxin efflux carrier PIN2. In Arabidopsis thaliana, PIN2 has the expected shootward localization in epidermis and lateral root cap; however, this carrier is localized toward the root tip (rootward) in cortical cells of the meristem, a deployment whose function is enigmatic. We use pharmacological and genetic tools to cause a shootward relocation of PIN2 in meristematic cortical cells without detectably altering PIN2 polarization in other cell types or PIN1 polarization. This relocation of cortical PIN2 was negatively regulated by the membrane trafficking factor GNOM and by the regulatory A1 subunit of type 2-A protein phosphatase (PP2AA1) but did not require the PINOID protein kinase. When GNOM was inhibited, PINOID abundance increased and PP2AA1 was partially immobilized, indicating both proteins are subject to GNOM-dependent regulation. Shootward PIN2 specifically in the cortex was accompanied by enhanced shootward polar auxin transport and by diminished gravitropism. These results demonstrate that auxin flow in the root cortex is important for optimal gravitropic response.

59 BASIC BIOLOGICAL SCIENCES↗

Solving the sample size problem for resource selection functions

Abstract Sample size sufficiency is a critical consideration for estimating resource selection functions (RSFs) from GPS‐based animal telemetry. Cited thresholds for sufficiency include a number of captured animals and as many relocations per animal N as possible. These thresholds render many RSF‐based studies misleading if large sample sizes were truly insufficient, or unpublishable if small sample sizes were sufficient but failed to meet reviewer expectations. We provide the first comprehensive solution for RSF sample size by deriving closed‐form mathematical expressions for the number of animals M and the number of relocations per animal N required for model outputs to a given degree of precision. The sample sizes needed depend on just 3 biologically meaningful quantities: habitat selection strength, variation in individual selection and a novel measure of landscape complexity, which we define rigorously. The mathematical expressions are calculable for any environmental dataset at any spatial scale and are applicable to any study involving resource selection (including sessile organisms). We validate our analytical solutions using globally relevant empirical data including 5,678,623 GPS locations from 511 animals from 10 species (omnivores, carnivores and herbivores living in boreal, temperate and tropical forests, montane woodlands, swamps and Arctic tundra). Our analytic expressions show that the required M and N must decline with increasing selection strength and increasing landscape complexity, and this decline is insensitive to the definition of availability used in the analysis. Our results demonstrate that the most biologically relevant effects on the utilization distribution (i.e. those landscape conditions with the greatest absolute magnitude of resource selection) can often be estimated with much fewer than animals. We identify several critical steps in implementing these equations, including (a) a priori selection of expected model coefficients and (b) regular sampling of background (pseudoabsence) data within a given definition of availability. We discuss possible methods to identify a priori expectations for habitat selection coefficients, effects of scale on RSF estimation and caveats for rare species applications. We argue that these equations should be a mandatory component for all future RSF studies.

Street, Garrett M.↗

Order-of-magnitude differences in retention of low-energy Ar implanted in Si and SiO{sub 2}

The retention of 1 and 5 keV Ar implanted at 45° in Si and 4.3 nm SiO{sub 2} on Si was studied at fluences between 3 × 10{sup 14} and 1.5 × 10{sup 16} cm{sup −2}. X-ray photoelectron spectroscopy (XPS) served to monitor the accumulation of Ar as well as the removal of SiO{sub 2}. Bombardment induced changes in oxygen chemistry caused the O 1s peak position to move toward lower binding energies by as much as 2.2 eV. Plotted versus depth of erosion, the fluence dependent changes in oxygen content, and peak position were similar at 1 and 5 keV. The Ar content of Si increased with increasing exposure, saturating at fluences of ∼2 × 10{sup 15} cm{sup −2} (1 keV) and ∼6 × 10{sup 15} cm{sup −2} (5 keV). Much less Ar was retained in the SiO{sub 2}/Si sample, notably at 1 keV, in which case the low-fluence Ar signal amounted to only 8% of the Si reference. The results imply that essentially no Ar was trapped in undamaged SiO{sub 2}, i.e., the Ar atoms initially observed by XPS were located underneath the oxide. At the lowest fluence of 5 keV Ar, the retention ratio was much higher (43%) because the oxide was already highly damaged, with an associated loss of oxygen. The interpretation was assisted by TRIM(SRIM) calculations of damage production. Partial maloperation of the ion beam raster unit, identified only at a late stage of this work, enforced a study on the uniformity of bombardment. The desired information could be obtained by determining x,y line scan profiles of O 1s across partially eroded SiO{sub 2}/Si samples. Fluence dependent Ar retention in Si was described using an extended version of the rapid relocation model which takes into account that insoluble implanted rare-gas atoms tend to migrate to the surface readily under ongoing bombardment. The range parameters required for the modeling were determined using TRIM(SRIM); sputtering yields were derived from the literature. The other three parameters determining the Ar signal, i.e., (1) the thickness w of the near-surface Si region devoid of Ar, (2) the relocation efficiency Ψ{sub rlc}, and (3) the effective attenuation length L in XPS analysis were varied within reasonable limits until the calculated retention curves for 1 and 5 keV Ar in Si agreed with experimental data to better than 8%, using the same XPS sensitivity factor throughout. Results: w = 1.4 ± 0.1 nm, Ψ{sub rlc} = 6.6 ± 0.5, and L = 2.7 ± 0.2 nm. Combining experimental and calculated data, it was found that the Ar trapping efficiency of the damaged oxide is intimately correlated with the loss of oxygen. The calculated stationary areal densities of all retained Ar are compared with results obtained by high-resolution medium-energy ion scattering spectrometry. Attractive areas of future research in rare gas retention and nanobubble formation are sketched briefly.

42 ENGINEERING↗

A study of the transport of charge carriers in coupled quantum regions

Specific features of controlled relocation of charge carriers in nanostructures based on tunnelingcoupled quantum regions formed by GaAs/AlGaAs heterojunctions are considered. The results of numerical simulation of dynamics of controlled tunneling relocation of the maximum in the amplitudes of wave functions of charge carriers are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In situ Oxidation of Ultrathin Silver Films on Ni(111)

Oxidation of silver films of one- and two-monolayer thicknesses on the Ni(111) surface was investigated by low-energy electron microscopy at temperatures of 500 and 600 K. Additionally, intensity-voltage curves were measured in situ during oxidation to reveal the local film structure on a nanometer scale. At both temperatures, we find that exposure to molecular oxygen leads to the destabilization of the Ag film with subsequent relocation of the silver atoms to small few-layer-thick silver patches and concurrent evolution of NiO(111) regions. Subsequent exposure of the oxidized surface to ethylene initiates the transformation of bilayer islands back into monolayer islands, demonstrating at least partial reversibility of the silver relocation process at 600 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wasatch Fault Structure from Machine Learning Arrival Times and High-Precision Earthquake Locations

Abstract On 18 March 2020, a magnitude 5.7 earthquake hit the Salt Lake valley in the state of Utah, United States. Using a dense geophone deployment and machine learning (ML), an additional several thousand events were detected and located. Currently, both the mainshock and the majority of the aftershocks are suspected to have occurred on or near a deeper portion of the Salt Lake segment of the Wasatch fault—part of a large range-bounding fault system thought to be capable of generating an Mw 7.2 earthquake. However, a small subset of aftershocks may have occurred on a portion of the more steeply, eastward dipping, and poorly understood West Valley fault. Unfortunately, the catalog locations and lack of focal mechanisms for this subset of aftershocks provide only a crude constraint on the true fault structure. To better illuminate fault structure, we relocate the ML-generated catalog with a range of magnitudes from −2 to 4.6, using: (1) NonLinLoc, a nonlinear location algorithm, (2) source-specific station terms, and (3) waveform coherence. We further compute first-motion focal mechanisms for 68 events. Results of the relocation suggest a simpler, minimally listric Wasatch fault geometry, contrary to what has been previously proposed. We also find that analysis of the focal mechanisms and waveform similarity indicates minimal event similarity throughout the Magna sequence, suggesting a highly complex and heterogeneous rupture zone, as opposed to rupture on a single plane. These findings suggest an increased seismic hazard due to the overall shallowness of the earthquake sequence and highly varied rupture mechanisms.

Geochemistry & Geophysics↗

Generating Mixed Patterns of Residential Segregation: An Evolutionary Approach

The Schelling model of residential segregation has demonstrated that even the slightest preference for neighbors of the same race can be amplified into community-wide segregation. However, these models are unable to simulate mixed, coexisting patterns of segregation and integration, which have been seen to exist in cities. Using evolutionary model discovery we demonstrate how including social factors beyond racial bias when modeling relocation behavior enables the emergence of strongly mixed patterns. Our results indicate that the emergence of mixed patterns is better explained by multiple factors influencing the decision to relocate; the most important being the interaction of nonlinear, rapidly diminishing racial bias with a recent, historical tendency to move. Additionally, preference for less isolated neighborhoods or preference for neighborhoods with longer residing neighbors may produce weaker mixed patterns. Finally, this work highlights the importance of exploring the influence of multiple hypothesized factors of decision making, and their interactions, within agent rules, when studying emergent outcomes generated by agent-based models of complex social systems.

97 MATHEMATICS AND COMPUTING↗

Comparison of Alternatives to the 2004 Vacuum Vessel Heat Transfer System

A study comparing different alternatives for the Vacuum Vessel Primary Heat Transfer System has been completed. Three alternatives were proposed in a Project Change Request (PCR-190) by relocating the heat exchangers (HXs) from the roof of the Tokamak building to inside the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The study evaluated the three alternatives and recommended modifications to one of them to arrive at a preferred configuration that included relocating the HXs inside the Tokamak building but outside the VVPSS tank as well as including a small safety-rated pump and HX in parallel to the main circulation pump and HX. The Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) removes heat generated in the VV during normal operation (10 MW, pulsed power) as well as the decay heat from the VV itself and from the structures/components attached to the VV (first wall, blanket, and divertor {approx}0.48 MW peak). Therefore, the VV PHTS has two safety functions: (1) contain contaminated cooling water (similar to the other PHTSs) and (2) provide passive cooling during an accident event. The 2004 design of the VV PHTS consists of two independent loops, each loop cooling half of the 18 VV segments with a nominal flow of 475 kg/s of water at about 1.1 MPa and 100 C. The total flow for both loops is 950 kg/s. Both loops are required to remove the heat load during normal plasma operation. During accident conditions, only one loop is needed to remove by natural convection (no pump needed) the decay heat of the complete VV and attached components. The heat is transferred to heat exchanger (HXs) located on top of the roof, outside the Tokamak building. These HXs are air-to-water (A/W) HXs. Three alternatives have been proposed for this cooling system. For a detailed discussion of these alternatives, please refer to Project Change Request, PCR-190 (Ref. 1). A brief introduction is given here. Alternative 1 includes only one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump. In addition, this alternative has two natural circulation safety loops. Both the safety and main loops supply water to the bottom of the VV with six branch lines and collect the heated water at the top of the vessel through six branches. The distribution headers are located in the lower pipe chase and the collection headers in the upper pipe chase. Each of these loops (one main and two emergency) has a HX mounted in the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The main HX is cooled using either Component Cooling Water System (CCWS) or Chilled Water System (CHWS) water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 1 taken from PCR-190. Alternative 2 is exactly the same as Alternative 1 except that there is only one emergency loop and one emergency HX. See Fig. 2 taken from PCR-190. Alternative 3 also has one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump and one natural circulation safety loop. In this case, both the safety and main loops supply water to the top of the VV with three branch lines and collect the heated water at the top of the vessel through three branches. Here, the distribution header is located in the upper pipe chase as is the collection header. As before, each of these loops has a HX mounted in the VVPSS tank. The main HX is cooled using either CCWS or CHWS water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 3 taken from PCR-190. The preferred configuration is developed by selecting specific attributes of the other configurations analyzed and the logic for selecting this configuration is discussed at the end of the document. It is a modification of Alternative 2 that eliminates the separate safety loop, but incorporates a small safety rated HX and pump in parallel with the main HX and pump. It uses 18 inlet and 18 outlet branches (as did the 2004 design) and locates the HXs outside of the VVPSS tank. Tables 1 and 2 examine alternatives to the 2004 VV heat transfer system design that were proposed in PCR-190, as well as the preferred option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inverted Attic Bulkhead for HVAC Ductwork: Roseville, California (Fact Sheet)

K. Hovnanian Homes constructed a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian(R) Homes(R) constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RERTR-12 Post-irradiation Examination Summary Report

The following report contains the results and conclusions for the post irradiation examinations performed on RERTR-12 Insertion 2 experiment plates. These exams include eddy-current testing to measure oxide growth; neutron radiography for evaluating the condition of the fuel prior to sectioning and determination of fuel relocation and geometry changes; gamma scanning to provide relative measurements for burnup and indication of fuel- and fission-product relocation; profilometry to measure dimensional changes of the fuel plate; analytical chemistry to benchmark the physics burnup calculations; metallography to examine the microstructural changes in the fuel, interlayer and cladding; and microhardness testing to determine the material-property changes of the fuel and cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Short-Term Monitoring Results for Advanced New Construction Test House—Roseville, California

A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft 2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian® Homes constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Monitoring Results for Advanced New Construction Test House -- Roseville, California

A builder (K. Hovnanian Homes), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols (Hendron, R. and Engebrecht, C. 'Building America House Simulation Protocols.' Golden, CO: National Renewable EnergyLaboratory, 2010) while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic toconditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing ofindividual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗