Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability Specifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Technical and Economic Assessment and Gap Analysis of Advanced Nuclear Reactor Integration with a Reference Oil Refinery

Efforts to identify the most-economic methods to decarbonize several sectors of the U.S. economy are underway. Industrial processes such as crude-oil refining rely heavily on energy-dense and easily stored and transported fossil fuels for powering their operations. Refineries use large amounts of energy, primarily derived from fossil sources to separate crude-oil components, break down heavier hydrocarbons into lighter compounds, remove impurities, reform hydrocarbon molecules, and generate steam and electricity for pumps and compressors and other various auxiliary systems. Crude-oil refining operations such as distillation, cracking, desulfurization, reforming, utilities systems and some offsite facilities collectively account for most of the energy consumption. Other operations such as hydrocracking or hydrotreating also require hydrogen for developing hydrogenation reactions which involve substantial heating to keep the reactors at high-temperature and pressure levels. All heat and energy demands are typically provided by natural gas (NG), oil, or other fuels, which makes refinery industry one of the most-difficult sectors to decarbonize. Nuclear power is a viable and energy-dense source of clean electricity, heat, and hydrogen to provide the large, sustainable energy supply that the refining industry demands. The U.S. Department of Energy’s (DOE’s) Integrated Energy Systems (IES) program is working to perform research and development, design, economic siting, and risk analysis. This state-of-the-art work will enable the first on-site demonstrations and commercial deployments of advanced small modular nuclear reactors (SMNRs) integrated with industries such as chemical production, refining, iron and steel making, and more. IES seeks to demonstrate the ability of advanced nuclear reactors to meet the heat and power demands of these industries while reducing carbon emissions in a sustainable and cost-competitive way. The primary objective of this research effort is to analyze industrial-scale SMNR integration intended to decarbonize refining facilities. The foreseen outcome is the provision of reliable, cost-competitive, and sustainable clean energy, alongside a reduction of carbon emissions. Specifically, the focus of this work lies on meeting the reference facilities’ heat and electricity demands with nuclear power while also supplying clean hydrogen via integrated high-temperature steam electrolysis (HTSE). This report presents a comprehensive technical and economic assessment of the integration of advanced nuclear reactors into a reference refinery, leveraging financial incentives from the Inflation Reduction Act (IRA). The evaluation aims to explore the potential economic benefits and challenges associated with incorporating advanced nuclear reactors into refinery operations, particularly in terms of energy efficiency, economic implications and environmental impact. By examining both the technical feasibility and economic viability, this analysis seeks to identify existing gaps and propose solutions for successful nuclear integration implementation. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the refining sector. A refinery reference-plant was developed, using an open-source refinery model, Petroleum Refinery Lifecycle Inventory Model (PRELIM) and expert assessment, as a base case for comparison with various nuclear integration options. The capacity of 100 kbd/day (KBD) of heavy crude-oil feed was selected to represent a general coking-type refinery with deep conversion capabilities (incorporating heavy-oil upgrading with FCC, coking, and associated hydrotreating process units), using a heavy crude-oil feed, which represents about 70% of U.S. refineries configurations. A summary of all cases considered in this study is shown in Table 1.

13 HYDRO ENERGY↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

On the Reliability of Parameter Inferences in a Multiscale Model for Transport in Stream Corridors

Nonreacting tracer tests capture information about physical processes in transient storage zones including the hyporheic zone (HZ). However, reliably extracting this information from breakthrough curves (BTCs) and distinguishing the effects of in-channel dispersion and transient storage are well-known challenges. Using BTCs from a nonreacting tracer test monitored at multiple locations, we explore ways for reliable parameter estimations. The identifiability of parameters is greatly influenced by the choice of forward and inverse modeling frameworks in addition to the quality of the data. Our forward model is a recently proposed multiscale model that uses subgrid transport models written in the Lagrangian form to represent transport along a diverse set of HZ pathways with a shape-free distribution of travel times. Joint distributions of HZ and channel parameters are estimated using the Markov Chain Monte Carlo technique. Numerical experiments show ambiguity between channel dispersion and HZ transport when the reach length is too short to allow significant solute-HZ interaction, the observation period is too brief to observe the tailing behavior, or the solute source is spread in time. In contrast, we obtained reliable parameter estimates by simultaneously fitting BTCs observed at different locations in the test reach using a single set of HZ parameters and section-specific channel areas and dispersion coefficients. Furthermore, this study demonstrates the estimation of travel time distributions, HZ exchange rates, and channel parameters in a new multiscale approach and offers guidance for extracting reliable parameter estimates from multiple BTCs.

54 ENVIRONMENTAL SCIENCES↗

Opportunities and Challenges for Remote Microreactor Operations

The nuclear industry is developing new advanced reactor technologies, and many companies are embracing this advancement by pursuing the development of microreactors. The term microreactor generally refers to a nuclear reactor with an operating power of 20 MW or less. The power range of microreactors makes them appealing for many use cases, such as powering remote communities, mining sites, and military bases. Most of the microreactor designs being pursued will incorporate remote facility operations into the final product. However, no framework has yet been developed to determine what remote operations systems require for reliable, resilient, and secure operation of a microreactor. This work identifies the challenges unique to remote operations and monitoring for microreactors specifically regarding instrumentation and control, communication methods, regulatory requirements, and operational policies. The types of commands and sensor measurements that must be transmitted between the facilities as well as methods for verifying the trustworthiness of these signals are assessed. This work evaluates the security, reliability, and performance requirements that must be met when considering the selection of communication hardware and protocols for use in remote operations. Also, an assessment was performed to study how remote operations fit within current regulatory requirements and what may need to be updated in regulatory policy to allow for remote operation. Finally, the operational contingencies unique to remote operations that must be in place for response to abnormal events are identified. This paper details these challenges and research opportunities to provide a foundation for the design of remote operation systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A System Level Comparative Study of SecondarySide Rectifiers for UAV Wireless Power Transfer in High-Altitude Airborne Energy Platforms

Wireless power transfer (WPT) systems for unmanned aerial vehicles (UAVs) must satisfy stringent design requirements to ensure reliable operation under constraints related to efficiency, thermal performance, altitude, weight, and reliability, particularly in airborne and high-altitude environments. Thermal management becomes increasingly challenging at higher altitudes due to reduced air density, while reliability is strongly affected by the number and complexity of active components. The weight and compactness of secondary-side rectifiers directly impact UAV flight endurance and system integration, influencing energy consumption and payload allocation. These factors collectively define the practical feasibility of UAV WPT systems and guide rectifier topology selection. This paper presents a comparative and experimentally validated evaluation framework for secondary-side rectifiers under UAV-specific constraints. Three representative rectifier architectures are analyzed using component-based assessment of weight, thermal behavior, and reliability, together with experimental efficiency measurements obtained from a 1 kW WPT prototype. The results show that the single-switch active rectifier achieves the highest peak efficiency of approximately 93.2% and an overall efficiency of 91%, while also offering advantages in weight and reliability. The findings demonstrate how constraint-oriented analysis, combined with experimental validation, enables informed selection of secondary-side rectifiers for UAV wireless power transfer applications, including emerging airborne and high-altitude platforms.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Evaluation of the Simplified Assessment Peak Equivalent Stress Design Limit Probability of Failure

The ASME Boiler and Pressure Vessel Code Section III Division 5 Subsection HH Subpart A (HHA) outlines requirements and qualification methods for graphite core components in high temperature reactor environments. One such structural qualification method is the Simplified Assessment outlined in HHA-3220, which represents a comparison of service level specific equivalent stresses to allowable stress values derived from target probability of failures (POFs). The target POF is based on the structural reliability class (SRC) for the components and service condition of interest, and is used to establish design limits for combined membrane and peak equivalent stresses. Combined membrane stress limits are derived from two parameter Weibull distribution fits of the graphite grade specific tensile strength data and the target POF. The combined membrane stress limits are then scaled based on the ratio of flexural strength to tensile strength (referred hereinafter as Rtf) to establish the corresponding peak equivalent stress limits. It is desired that the target POF is at least maintained for both combined membrane and peak equivalent design limits, especially with the use of Rtf. The assessment presented herein examines tensile and flexural data for medium and fine grade graphites relative to the calculated combined membrane and peak equivalent stress limits per HHA-3220 and illustrates the simplified assessment method results in anticipated, or at least conservative, peak equivalent design stress limits.

36 - MATERIALS SCIENCE↗

Development of Transformative Preparation Methods to Push up High Q&G Performance of FRIB Spare HWR Cryomodule Cavities

The FRIB accelerator project construction, a top priority of US nuclear science, was completed in January 2022, and is now moving to user operation. The stable and reliable operation of the accelerating cryomodules is essential in achieving/fulfilling DOE and user expectations. So far, FRIB cryomodules meet all FRIB specifications for cavity performance. However, during the lifetime of machine operation, degradation of cryomodule performance is possible, as reported in similar operating facilities (CEBAF, SNS). If cryomodule degradation is observed at FRIB, the under-performing cryomodule will require replacement/maintenance. In effort to manage operational reliability, FRIB plans to construct a 0.53 half-wave cryomodule to serve as an active spare. In a parallel effort, FRIB will also work toward increasing operational Q and gradient of spare cryomodule cavities to gain an overall performance margin to support future operational reliability. The current FRIB cavity designs have a potential to operate at gradients higher than 8 MV/m, but are currently limited by field emission (FE) and/or high field Q slope (HFQS); known issue in buffered chemical polished (BCP) treated cavities. The proposal looks to develop transformative surface preparation treatments to improve the operational gradient of spare cryomodules higher than 10 MV/m while maintaining high Q. Thus, increasing operational margin by 30 - 50%. With the goal to improve operational reliability set, the proposal will investigate multiple objectives as possible paths forward to achieve an overall increase in cavity performance and gain a better understanding of SRF limiting mechanisms. The proposal will study the application of different chemical surface treatments to 0.53 half-wave cavities, with the addition of low temperature bakes (LTB), and measure their effects on accelerating performance. Proposed chemical treatments to be explored in this proposal include conventional EP acid mixtures, as well as innovated EP and BCP acid mixtures designed to simplify processing paths in migrating FE and HFQS. The proposed transformative treatment wet N-doping also has the potential to replicate recent advancements in SRF technology relating to nitrogen doping and high Q operation without the requirement for an ultra-high vacuum annealing furnace; currently being developed at FNAL and JLAB. In parallel, high Q performance relating to flux trapping will be investigated with the installation of a second layer of magnetic shielding in the vertical test Dewar. The research objectives presented in the proposal, and their corresponding effects on cavity performance, will provide essential knowledge and future guidance to the SRF community and provide possible paths for future SRF based projects and applications.

43 PARTICLE ACCELERATORS↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASME Design Code Rule Changes for Nuclear Graphite

The American Society of Mechanical Engineers Boiler Pressure and Vessel Code (ASME BPVC) Section III, Division 5, Article HHA-3000 outlines graphite core component and graphite core assembly design guidelines. Graphite core components are defined as ?components manufactured from graphite that are installed to form a graphite core assembly within the reactor pressure vessel of a high temperature, graphite moderated fission reactor.? (p. 413) Graphites? inherent defect distributions do not allow for deterministic material reliability. Rather, graphite has variable strength distributions which change by grade. Article HHA-3000 outlines two semi-probabilistic methods, the full and simplified assessments, which set design load limit targets for each of three component structural reliability classes. The Design Task Group was officially recognized as a specialized task group within ASME November of 2023, though we?ve been collaborating since 2022. The purpose of the Design Task Group is to correct, clarify, and make HHA-3000 function as intended. The Design Task Group will sunset once we?ve achieved our objectives. The Design Task Group was specifically told to not write new Code. While there may be more precise and more accurate methods to determine reliability targets, the current methods are conservative, relatively simple to implement, and have thus far been considered satisfactory for setting design reliability targets. Much of the ground-work to write proposal files and background documents for records to make the changes needed to achieve our objective have been completed. The Design Task Group has documented much of their work through papers, presentations, and memorandums. Three memorandums in which INL team members had substantial contributions are found in the Appendices: FEA Modeling for the Baseline Program, Evaluating the Effects on Margin of Updating the Threshold and Shape Parameters in the Full Assessment, and Interpretations of the Full and Simplified Assessments in ASME BPVC. Most of the on-going work to achieve the Design Task Group?s objective will be addressing comments on existing records and moving records through the balloting process. The Design Task Group met bi-weekly mostly through the end of FY2023. Since February 2024, the Design Task Group has mostly been completed with solving and documenting the technical issues associated with the assessments. Unless new tasks are identified, the remaining work of the Design Task Group will be political and editorial.

97 MATHEMATICS AND COMPUTING↗

Evaluating switch lifetime in soft-switched single-stage differential-mode SST

The reliability of semiconductor switches in single-stage differential-mode solid-state transformers (DM-SSTs) has not been systematically evaluated under soft-switching operation and realistic grid conditions. This paper presents a switch-level reliability analysis for soft-switched and hard-switched DM-SST configurations by integrating converter-specific power loss modeling with empirical lifetime prediction. Analytical derivation of device current profiles specific to the DM-SST is used to characterize electrothermal stress, which is then mapped to lifetime using degradation models obtained from power cycling tests (PCTs). Applied to realistic SST load profiles and grid voltage variations, this approach provides a probabilistic prediction of switch lifetime for the DM-SST. Lifetime estimates for both SiC MOSFETs and Si IGBTs are presented, offering insight into device degradation under converter operating conditions. The results quantify the reliability benefits of soft switching in single-stage SSTs, highlighting how switching dynamics influence long-term switch degradation.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Photovoltaic Inverter Failure Mechanism Estimation Using Unsupervised Machine Learning and Reliability Assessment

This article introduces a data-driven approach to assessing failure mechanisms and reliability degradation in outdoor photovoltaic (PV) string inverters. The manufacturer's stated PV inverter lifetime can vary due to the impact of operating site conditions. To address limitations in degradation estimation through accelerated testing, condition monitoring, or degradation modeling, we propose a machine learning (ML) oriented approach. Utilizing data from a 1.4 MW PV power plant operational since 2016, with 46 string PV inverters tied to the grid, we employ the unsupervised one-class support vector machine ML technique to analyze inverter and sensor data, capable of classifying humidity cycling and temperature fluctuations as dominant failure mechanisms. Utilizing the anomaly alert relationship and alert details specific to the inverter, the level of PV inverter output is considered as its availability or available reliability. Subsequently, a continuous Markov model is applied to six-month alert data, revealing an average stated reliability of 20% after 20 years of continuous operation. These results support recommendations for time-bound preventive measures to enhance PV inverter reliability under diverse outdoor conditions. Furthermore, the approach provides a nondestructive, top–down, and generalized method for analyzing any commercial PV inverter exposed to outdoor conditions, contingent on the availability of relevant data.

14 SOLAR ENERGY↗

Modeling Flexible Generator Operating Regions via Chance- constrained Stochastic Unit Commitment

Here, we introduce a novel chance-constrained stochastic unit commitment model to address uncertainty in renewables' production uncertainty in power systems operation. For most thermal generators,underlying technical constraints that are universally treated as "hard" by deterministic unit commitment models are in fact based on engineering judgments, such that system operators can periodically request operation outside these limits in non-nominal situations, e.g., to ensure reliability. We incorporate this practical consideration into a chance-constrained stochastic unit commitment model, specifically by in-frequently allowing minor deviations from the minimum and maximum thermal generator power output levels. We demonstrate that an extensive form of our model is computationally tractable for medium-sized power systems given modest numbers of scenarios for renewables' production. We show that the model is able to potentially save significant annual production costs by allowing infrequent and controlled violation of the traditionally hard bounds imposed on thermal generator production limits. Finally, we conduct a sensitivity analysis of optimal solutions to our model under two restricted regimes and observe similar qualitative results.

42 ENGINEERING↗

Propagation of Input Uncertainties in Numerical Simulations of Laser Powder Bed Fusion

Laser powder bed fusion has the potential of redefining state-of-the-art processing and production methods, but defect formation and inconsistent build quality have limited the implementation of this process. Numerical models are widely used to study this process and predict the formation of these defects. Presently, the uncertainties of model input parameters and thermophysical properties used by these numerical simulations have not been investigated. In the present study, the uncertainty in these input parameters and material properties are quantified for laser powder bed fusion, with and without a simulated powder bed, to determine their influence on the predictive accuracy of an experimentally validated numerical model. Accounting for all possible sources of uncertainty quickly becomes computationally expensive on account of the curse of dimensionality. Uncertainty in laser absorption, solid, and liquid specific heat of the metal were found to have the largest effect on model prediction reliability with or without the use of a powder bed. Results also illustrate that accounting for these three uncertain parameters still captures the majority of model prediction uncertainty. Furthermore, the methodology of this study may be used to understand the uncertainty in as-built microstructure through propagation to microstructure prediction models, or applied under processing conditions where high Péclet numbers are observed and the thermal convection and fluid flow within the molten pool are substantial.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Standard operating procedures for the comprehensive and reliable analysis of cannabis terpenes

Terpenes are the primary determinants of cannabis flower aroma, and ongoing research tests their potential for impacting the overall experience. Frustratingly, despite the importance of terpenes in cannabis physiology and commercial uses, literature reports vary widely regarding the major constituents of volatile blends and the concentrations of individual terpenes. Here, in this article, we provide detailed descriptions of complementary approaches that will allow researchers to determine the identity and quantity of cannabis terpenes unequivocally and reliably. These standard operating procedures will guide decisions about which method to employ to address specific analytical goals. We are including two application examples to illustrate the utility of different approaches for tackling the analysis of terpenes in cannabis flower samples.

Polito, Joshua↗

“One Table to Rule Them All”: How a Single Table can Enable Extensive Insights, Analytics and Assessment on Human Mobility Data

While much research has been conducted in Human Mobility Science, most studies on the analytics/insights part generally focus on one of the following: processing and analytics on human stop-trip behavior, design of individual mobility metrics (often in silos), calculation and characterization of only a handful (typically 5-6) of human mobility metrics on geospatial-temporal human mobility data of interest. Although human mobility research offers a vast and diverse array of available metrics, most individual studies typically compute only a small subset of five or six metrics at a time when analyzing trajectory datasets of human mobility across different areas of interest. This paper is motivated by the critical need to repeatedly compute an extensive array of human mobility metrics across several trajectory datasets and perform individual metric-level benchmarking to establish a new, standardized Test and Evaluation (T&E) suite for the field of Human Mobility Science. We first present our findings on the minimal yet sufficient pre-processing required to reliably and efficiently compute a wide range of human mobility metrics. The key findings are specifically related to the proposed Composite Stop Locations table, which serves as a core pre-processing data layer. Subsequently, we present a case study demonstrating how the Composite Stop Locations table facilitates computation of at least 14 distinct human mobility metrics (unlike 5-6 different set of metrics used for studies in the literature) using the popular and open-source OpenPFLOW dataset. Finally, we have also presented an example of our benchmarking methodology to evaluate the quality and performance of the trajectory dataset of interest, assessed across multiple human mobility metrics.

De, Debraj [ORNL] (ORCID:0000000233630020)↗