Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

On-Orbit Xenon Refueling Loading Times and Transient Analysis

The Power and Propulsion Element (PPE) of the Lunar Orbital Platform-Gateway will demonstrate the first on-orbit refueling of xenon propellant for a solar electric propulsion system. An analysis was performed in Microsoft Excel to determine what factors influence the overall refueling time of a single 2,000-kilogram capacity xenon propellant tank, as well as provide estimates for overall refueling duration. Due to the high heat of compression of xenon, the propellant tank could exceed its maximum allowable temperature during refueling if the xenon flow rate and temperature are unregulated. In order to prevent overheating, a logic based "bang-bang" operation was used for refueling, shutting off the mass feed when the tank reached a maximum temperature. Heat is removed from the tank via radiation to the surrounding spacecraft bus. The analysis shows that optimizing key parameters such as mass flow rate into the tank, residual propellant in the tank during the onset of refueling, and tank diameter significantly reduces the overall refueling duration. Optimization is not straightforward, however, as the loading time does not trend monotonically with the parameters. Overall, the most significant impact on loading duration comes from altering the residual propellant in the tank. Increasing the mass of residual propellant from 2 percent to 20 percent reduces the overall refueling duration by 56 percent. Future work based on this analysis includes creation of a SINDA/FLUINT model and building a ground-based xenon refueling system emulator.

Xenon↗

Residual thermal stress control in composite reinforced metal structures

Advanced composite materials, composed of boron or graphite fibers and a supporting matrix, make significant structural efficiency improvements available to aircraft and aerospace designers. Residual stress induced during bonding of composite reinforcement to metal structural elements can be reduced or eliminated through suitable modification to the manufacturing processes. The most successful method employed during this program used a steel tool capable of mechanically loading the metal component in compression prior to the adhesive bonding cycle. Compression loading combined with heating to 350 F during the bond cycle can result in creep deformation in aluminum components. The magnitude of the deformation increases with increasing stress level during exposure to 350 F.

Kelly, J. B.↗

Applied-field magnetoplasmadynamic engine developments

There are potential space exploration missions which may significantly benefit from the use of electric propulsion at power levels of hundreds of kilowatts. The applied magnetic field MPD thruster is potentially capable of efficient, high specific impulse operation in this power range. This paper describes current experimental and analytical efforts to further the development of such a thruster and presents the latest results. In particular, efforts to measure, simultaneously, the thrust developed by the archead and by the electromagnet, and to evaluate the effect of a diffuser on vacuum tank back pressure, are presented and discussed. It was found that with ammonia vapor as propellant, the vacuum tank pressure was reduced from 8 to 4.9 Pa at a power level of 80 kW. This pressure decrease is expected to become greater as the power and applied field are increased. Also, the development of a cathode/plasma interaction model for determining the heat loads to the cathode as functions of the various free stream plasma parameters is presented. This model is combined with a cathode thermal model in order to provide a complete and integrated picture of MPD thruster cathode operation. Several computational examples are used to illustrate the combined model.

Goodfellow, K. D.↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as -150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Nabity, James↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as 150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze/thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Paul, Heather↗

Shape Memory Characteristics of Ti(sub 49.5)Ni(sub 25)Pd(sub 25)Sc(sub 0.5) High-Temperature Shape Memory Alloy After Severe Plastic Deformation

A Ti(49.5)Ni25Pd25Sc(0.5) high-temperature shape memory alloy is thermomechanically processed to obtain enhanced shape-memory characteristics: in particular, dimensional stability upon repeated thermal cycles under constant loads. This is accomplished using severe plastic deformation via equal channel angular extrusion (ECAE) and post-processing annealing heat treatments. The results of the thermomechanical experiments reveal that the processed materials display enhanced shape memory response, exhibiting higher recoverable transformation and reduced irrecoverable strain levels upon thermal cycling compared with the unprocessed material. This improvement is attributed to the increased strength and resistance of the material against defect generation upon phase transformation as a result of the microstructural refinement due to the ECAE process, as supported by the electron microscopy observations.

Atli, K. C.↗

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.↗

U-Groove aluminum weld strength improvement

Though butt-welds are among the most preferred joining methods in aerostructures, their strength dependence on inelastic mechanics is generally the least understood. This study investigated experimental strain distributions across a thick aluminum U-grooved weld and identified two weld process considerations for improving the multipass weld strength. The extreme thermal expansion and contraction gradient of the fusion heat input across the groove tab thickness produces severe peaking, which induces bending under uniaxial loading. The filler strain-hardening decreased with increasing filler pass sequence, producing the weakest welds on the last pass side. Current welding schedules unknowingly compound these effects which reduce the weld strength. A depeaking index model was developed to select filler pass thicknesses, pass numbers, and sequences to improve depeaking in the welding process. The intent is to combine the strongest weld pass side with the peaking induced bending tension to provide a more uniform stress and stronger weld under axial tensile loading.

Verderaime, V.↗

U-groove aluminum weld strength improvement

Though butt-welds are among the most preferred joining methods in aerostructures, their strength dependence on inelastic mechanics is generally the least understood. This study investigated experimental strain distributions across a thick aluminum U-grooved weld and identified two weld process considerations for improving the multipass weld strength. The extreme thermal expansion and contraction gradient of the fusion heat input across the groove tab thickness produces severe peaking which induces bending under uniaxial loading. The filler strain-hardening deceased with increasing filler pass sequence, producing the weakest welds on the last pass side. Current welding schedules unknowingly compound these effects which reduce the weld strength. A de-peaking index model was developed to select filler pass thicknesses, pass numbers, and sequences to improve de-peaking in the welding process. Intent is to combine the strongest weld pass side with the peaking induced bending tension to provide a more uniform stress and stronger weld under axial tensile loading.

Verderaime, V.↗

InSight Aerothermal Environment Assessment

The Mars Interior Exploration using Seismic Investigations, Geodesy and Heat Transport (InSight) spacecraft, which successfully touched down on the planet surface on November 26, 2018, was proposed as a near build-to-print copy of the Mars Phoenix vehicle to reduce the overall cost and risk of the mission. Since the lander payload and the atmospheric entry trajectory were similar enough to those of the Phoenix mission, it was expected that the Phoenix thermal protection material thickness would be sufficient to withstand the entry heat load. However, allowances were made for increasing the heatshield thickness because the planned spacecraft arrival date coincided with the Mars dust storm season. The aftbody Thermal Protection System (TPS) components were not expected to change. In a first for a US Mars mission, the aerothermal environments for InSight included estimates of radiative heat flux to the aftbody from the wake. The combined convective and radiative heat fluxes were used to determine if the as-flown Phoenix thermal protection system (TPS) design would be sufficient for InSight. Although the radiative heat fluxes on the aftbody were predicted to be comparable to, or even higher than the local convective heat fluxes, all analyses of the aftbody TPS showed that the design would still be adequate. Aerothermal environments were computed for the vehicle from post-flight reconstruction of the atmosphere and trajectory and compared.

Beck, Robin↗

InSight Aerothermal Environment Assessment

The Mars Interior Exploration using Seismic Investigations, Geodesy and Heat Transport (InSight) spacecraft, which successfully touched down on the planet surface on November 26, 2018, was proposed as a near build-to-print copy of the Mars Phoenix vehicle to reduce the overall cost and risk of the mission. Since the lander payload and the atmospheric entry trajectory were similar enough to those of the Phoenix mission, it was expected that the Phoenix thermal protection material thickness would be sufficient to withstand the entry heat load. However, allowances were made for increasing the heatshield thickness because the planned spacecraft arrival date coincided with the Mars dust storm season. The aftbody Thermal Protection System (TPS) components were not expected to change. In a first for a US Mars mission, the aerothermal environments for InSight included estimates of radiative heat flux to the aftbody from the wake. The combined convective and radiative heat fluxes were used to determine if the as-flown Phoenix thermal protection system (TPS) design would be sufficient for InSight. Although the radiative heat fluxes on the aftbody were predicted to be comparable to, or even higher than the local convective heat fluxes, all analyses of the aftbody TPS showed that the design would still be adequate. Aerothermal environments were computed for the vehicle from post-flight reconstruction of the atmosphere and trajectory and compared with the design environments. These comparisons showed that the predicted as-flown conditions were less severe than the design conditions.

Beck, Robin A. S.↗

Heat Shield And Axial Retainer For Turbopump Blade

Modified configuration for axial retention of blades of cryogenic turbopump expected to reduce dynamic and thermal stresses, thereby increasing operating life. Expected to overcome some of structural limitations in which various components of "fir-tree" blade/disk attachments shaped in such way as to concentrate stresses. Advantages include: No overhung loading on attachment faces of disk or blades; No additional stress concentrators added to attachment faces of disk or blades; and No large axial thermal gradients on edges of disk and blades.

Moore, Jerry H.↗

System implications of aperture-shade design for the SIRTF Observatory

The 1-m-aperture Space Infrared Telescope Facility (SIRTF) will operate with a sensitivity limited only by the zodiacal background. This sensitivity requirement places severe restrictions on the amount of stray light which can reach the focal plane from off-axis sources such as the sun or earth limb. In addition, radiation from these sources can degrade the lifetime of the telescope and instrument cryogenic system which is now planned for two years before the first servicing. Since the aperture of the telescope represents a break in the telescope insulation system and is effectively the first element in the optical train, the aperture shade is a key system component. The mass, length, and temperature of the shade should be minimized to reduce system cost while maximizing the telescope lifetime and stray light performance. The independent geometric parameters that characterize an asymmetrical shade for a 600 km, 28 deg orbit were identified, and the system sensitivity to the three most important shade parameters were explored. Despite the higher heat loads compared to previously studied polar orbit missions, the analysis determined that passive radiators of a reasonable size are sufficient to meet the system requirements. An optimized design for the SIRTF mission, based on the sensitivity analysis, is proposed.

Lee, J. H.↗

Microwave Sterilization and Depyrogenation System

A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time at a given flow rate. These technologies can be employed in small-scale systems for efficient production of MGW in the laboratory or in a range of larger systems that meet various industrial requirements. The microwave antennas can also be adapted to selectively sterilize vulnerable connections to ultra-pure water production facilities or biologically vulnerable systems where microorganisms may intrude.

Akse, James R.↗

Design Concepts for Cooled Ceramic Matrix Composite Turbine Vanes

This project demonstrated that higher temperature capabilities of ceramic matrix composites (CMCs) can be used to reduce emissions and improve fuel consumption in gas turbine engines. The work involved closely coupling aerothermal and structural analyses for the first-stage vane of a high-pressure turbine (HPT). These vanes are actively cooled, typically using film cooling. Ceramic materials have structural and thermal properties different from conventional metals used for the first-stage HPT vane. This project identified vane configurations that satisfy CMC structural strength and life constraints while maintaining vane aerodynamic efficiency and reducing vane cooling to improve engine performance and reduce emissions. The project examined modifications to vane internal configurations to achieve the desired objectives. Thermal and pressure stresses are equally important, and both were analyzed using an ANSYS® structural analysis. Three-dimensional fluid and heat transfer analyses were used to determine vane aerodynamic performance and heat load distributions.

Boyle, Robert↗

Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

Bigelow, C. A.↗

Solar water heating system for a lunar base

An investigation of the feasibility of using a solar water heater for a lunar base is described. During the investigation, computer codes were developed to model the lunar base configuration, lunar orbit, and heating systems. Numerous collector geometries, orientation variations, and system options were identified and analyzed. The results indicate that the recommended solar water heater could provide 88 percent of the design load and would not require changes in the overall lunar base design. The system would give a 'safe-haven' water heating capability and use only 7 percent to 10 percent as much electricity as an electric heating system. As a result, a fixed position photovoltaic array can be reduced by 21 sq m.

Somers, Richard E.↗