Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multi frame synchrotron radiography of pulsed power driven underwater single wire explosions

We present herein the first use of synchrotron-based phase contrast radiography to study pulsed-power driven high energy density physics experiments. Underwater electrical wire explosions have become of interest to the wider physics community due to their ability to study material properties at extreme conditions and efficiently couple stored electrical energy into intense shock waves in water. The latter can be shaped to provide convergent implosions, resulting in very high pressures (1-10 Mbar) produced on relatively small pulsed power facilities (100s of kA-MA). Multiple experiments have explored single-wire explosions in water, hoping to understand the underlying physics and better optimize this energy transfer process; however, diagnostics can be limited. Optical imaging diagnostics are usually obscured by the shock wave itself; and until now, diode-based X-ray radiography has been of relatively low resolution and rather a broad x-ray energy spectrum. Utilising phase contrast imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility, we were able to image both the exploding wire and the shock wave. Probing radiation of 20-50 keV radiographed 200 μm tungsten and copper wires, in ~2-cm diameter water cylinders with resolutions of 8 μm and 32 μm. The wires were exploded by a ~30-kA, 500-ns compact pulser, and 128 radiographs, each with a 100-ps X-ray pulse exposure, spaced at 704 ns apart were taken in each experiment. Abel inversion was used to obtain the density profile of the wires, and the results are compared to two dimensional hydrodynamic and one dimensional magnetohydrodynamic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiframe point-projection radiography imaging based on hybrid X-pinch

This paper demonstrates the possibility of using a new configuration of the hybrid X-pinch to produce a set of spatially and temporarily separate x-ray bursts that could be used for the radiography of dynamic events. To achieve this, a longer than normal wire is placed between the conical electrodes of the hybrid X-pinch, and a set of small spacers (fishing weights) is placed along the wire. Each subsection of the wire then acts as a unique X-pinch, producing its own radiation burst from a small (~3 µm) spot. The timing between bursts is 20–50 ns, and each is <2 ns in duration. For comparison, if a longer wire is simply employed without spacers, hotspots of radiation occur in random positions and the time between any two bursts does not exceed 20 ns. Examples of two and three frame point-projection radiography of solid-state and plasma test objects are given.

47 OTHER INSTRUMENTATION↗

Inferring the temperature profile of the radiative shock in the COAX experiment with shock radiography, Dante, and spectral temperature diagnostics

Predicting and modeling the behavior of experiments with radiation waves propagating through low-density foams require a detailed quantification of the numerous uncertainties present. In regimes where a prominent radiative shock is produced, key dynamical features include the shock position, temperature, and curvature and the spatial distribution and temperature of the corresponding supersonic radiation wave. The COAX experimental platform is designed to constrain numerical models of such a radiative shock propagating through a low-density foam by employing radiography for spatial and shock information, Dante for characterizing the x-ray flux from the indirectly driven target, and a novel spectral diagnostic designed to probe the temperature profile of the wave. In this work, we model COAX with parameterized 2D simulations and a Hohlraum-laser modeling package to study uncertainties in diagnosing the experiment. The inferred temperature profile of the COAX radiation transport experiments has been shown to differ from simulations more than expected from drive uncertainties that have been constrained by simultaneous soft x-ray flux and radiography measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic Source Determination and X-Ray Radiography Detection of Nonuniformities on High-Density Carbon Ablators

Recent deuterium-tritium (D-T)–layered implosion experiments at the National Ignition Facility have achieved a burning plasma and >1-MJ neutron yield. A series of repeat experiments have shown that the degree of performance is very likely dependent on capsule quality, including the quantity of what are collectively termed “high- Z particles.” These particles are detected on a custom-built radiography system, known as the Sagometer, during the final target qualification process. The term particles is misleading, as the source of these nonuniformities in the capsule images is uncertain; the term detection will be used instead. An increased number of D-T targets have been rejected at the final stages of production due to Sagometer detections. Late detections are deleterious in terms of loss of production parts, effort, and overall operating efficiency. In response, we undertook an effort to determine the origin of these detections and to ultimately mitigate target losses caused by them. Through careful testing and analysis, we have determined neither insufficient production cleanliness nor hohlraum shedding is responsible for the detections on the capsule. Here, we determined that the detections are inherent to the capsule and have made efforts to use the Zeiss Xradia to identify them earlier in the production process. While testing revealed the Xradia is not currently sufficient for identifying such particles using radiography images, we continue to look to other forms of metrology to down select the capsules early in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Radiography and Passive Measurements for Radiological Threat Detection in Cargo

Abstract Radiography is widely understood to provide information complimentary to passive detection: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions which may mask a passive radiological signal. We present a method for combining radiographic and passive data which uses the radiograph to provide an estimate of scatter and attenuation for possible sources. This approach allows quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present first results for this method for a simple modeled test case of a cargo container driving through a PVT portal. With this inversion approach, we address criteria for an integrated passive and radiographic screening system and how detection of SNM threats might be improved in such a system.

Combining Radiography and Passive Measurements for↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of biodiesel blend and conventional diesel spray structure using x-ray radiography.

The near-nozzle structure of several nonevaporating biodiesel-blend sprays has been studied using X-ray radiography. Radiography allows quantitative measurements of the fuel distribution in sprays to be made with high temporal and spatial resolution. Measurements have been made at different values of injection pressure, ambient density, and with two different nozzle geometries to understand the influences of these parameters on the spray structure of the biodiesel blend. These measurements have been compared with corresponding measurements of Viscor, a diesel calibration fluid, to demonstrate the fuel effects on the spray structure. Generally, the biodiesel-blend spray has a similar structure to the spray of Viscor. For the nonhydroground nozzle used in this study, the biodiesel-blend spray has a slightly slower penetration into the ambient gas than the Viscor spray. The cone angle of the biodiesel-blend spray is generally smaller than that of the Viscor spray, indicating that the biodiesel-blend spray is denser than the Viscor spray. For the hydroground nozzle, both fuels produce sprays with initially wide cone angles that transition to narrow sprays during the steady-state portion of the injection event. These variations in cone angle with time occur later for the biodiesel-blend spray than for the Viscor spray, indicating that the dynamics of the injector needle as it opens are somewhat different for the two fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Proton Radiography: Its uses and Resolution Scaling

Los Alamos National Laboratory has used high energy protons as a probe in flash radiography for over a decade. In this time the proton radiography project has used 800 MeV protons, provided by the LANSCE accelerator facility at LANL, to diagnose over five-hundred dynamic experiments in support of stockpile stewardship programs as well as basic materials science. Through this effort significant experience has been gained in using charged particles as direct radiographic probes to diagnose transient systems. The results of this experience will be discussed through the presentation of data from experiments recently performed at the LANL pRad.

36 MATERIALS SCIENCE↗

Proton radiography in three dimensions: A proof of principle of a new technique

Purpose: Monte Carlo simulations were used to investigate a range of phantom configurations to establish enabling three-dimensional proton radiographic techniques.Methods: A large parameter space of stacked phantom geometries composed of tissue inhomogeneity materials such as lung, bone, and cartilage inserted within water background were simulated using a purposefully modified version of TOPAS, an application running on top of the GEANT4 Monte Carlo code. The phantoms were grouped in two classes, one with the inhomogeneity inserted only half-way in the lateral direction and another with complete inhomogeneity insertion. The former class was used to calculate the track count and the energy fluence of the protons as they exit the phantoms either having traversed the inhomogeneity or not. The latter class was used to calculate one yield value accounting for loss of protons due to physical processes only and another yield value accounting for deliberately discarded protons due to large scattering angles. A graphical fingerprinting method was developed to determine the inhomogeneity thickness and location within the phantom based on track count and energy fluence information. Two additional yield values extended this method to the general case which also determines the inhomogeneity material and the phantom thickness.Results: The graphical fingerprinting method was manually validated for two, and automatically tested for all, tissue materials using an exhaustive set of inhomogeneity geometries for 16 cm thick phantoms. Unique recognition of test phantom configurations was achieved in the large majority of cases. The method in the general case was further tested using an exhaustive set of inhomogeneity and phantom tissues and geometries where the phantom thicknesses ranged between 8 and 24 cm. Unique recognition of the test phantom configurations was achieved only for part of the phantom parameter space. The correlations between the remaining false positive recognitions were analyzed.Conclusions: The concept of 3D proton radiography for tissue inhomogeneities of simple geometries was established with the current work. In contrast to conventional 2D proton radiography, the main objective of the demonstrated 3D technique is not proton range. Rather, it is to measure the depth and thickness of an inhomogeneity located in an imaged geometry. Further work is needed to extend and apply the method to more complex geometries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-37: Combining Proton Radiography and X-Ray CT Information to Better Estimate Relative Proton Stopping Power in a Clinical Environment

Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.

07 ISOTOPE AND RADIATION SOURCES↗

Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151

Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.

60 APPLIED LIFE SCIENCES↗

X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-207A-05: Feature Based Water Equivalent Path Length (WEPL) Determination for Proton Radiography by the Technique of Time Resolved Dose Measurement

Purpose: Studies show that WEPL can be determined from modulated dose rate functions (DRF). However, the previous calibration method based on statistics of the DRF is sensitive to energy mixing of protons due to scattering through different materials (termed as range mixing here), causing inaccuracies in the determination of WEPL. This study intends to explore time-domain features of the DRF to reduce the effect of range mixing in proton radiography (pRG) by this technique. Methods: An amorphous silicon flat panel (PaxScan™ 4030CB, Varian Medical Systems, Inc., Palo Alto, CA) was placed behind phantoms to measure DRFs from a proton beam modulated by a specially designed modulator wheel. The performance of two methods, the previously used method based on the root mean square (RMS) and the new approach based on time-domain features of the DRF, are compared for retrieving WEPL and RSP from pRG of a Gammex phantom. Results: Calibration by T{sub 80} (the time point for 80% of the major peak) was more robust to range mixing and produced WEPL with improved accuracy. The error of RSP was reduced from 8.2% to 1.7% for lung equivalent material, with the mean error for all other materials reduced from 1.2% to 0.7%. The mean error of the full width at half maximum (FWHM) of retrieved inserts was decreased from 25.85% to 5.89% for the RMS and T{sub 80} method respectively. Monte Carlo simulations in simplified cases also demonstrated that the T{sub 80} method is less sensitive to range mixing than the RMS method. Conclusion: WEPL images have been retrieved based on single flat panel measured DRFs, with inaccuracies reduced by exploiting time-domain features as the calibration parameter. The T{sub 80} method is validated to be less sensitive to range mixing and can thus retrieve the WEPL values in proximity of interfaces with improved numerical and spatial accuracy for proton radiography.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗