Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

STS 63: Post Flight Presentation

At a post flight conference, Captain Jim Wetherbee, of STS Flight 63, introduces each of the other members of the STS 63 crew (Eileen Collins, Pilot; Dr. Bernard Harris, Payload Commander; Dr. Michael Foale, Mission Specialist from England; Dr. Janice Voss, Misssion Specialist; and Colonel Vladimir Titor, Misssion Specialist from Russia. A short biography of each member and a brief description of their assignment during this mission is given. A film was shown that included the preflight suit-up, a view of the launch site, the actual night launch, a tour of the Space Shuttle and several of the experiment areas, several views of earth and the MIR Space Station and cosmonauts, the MIR-Space Shuttle rendezvous, the deployment of the Spartan Ultraviolet Telescope, Foale and Harris's EVA and space walk, the retrieval of Spartan, and the night entry home, including the landing. Several spaceborne experiments were introduced: the radiation monitoring experiment, environment monitoring experiment, solid surface combustion experiment, and protein crystal growth and plant growth experiments. This conference ended with still, color pictures, taken by the astronauts during the entire STS 63 flight, being shown.

Source record↗

STS-64 Space Shuttle mission report

The STS-64 Space Shuttle Program Mission Report summarizes the Payload activities as well as the Orbiter, External Tank (ET), Solid Rocket Booster (SRB), Redesigned Solid Rocket Motor (RSRM), and the Space Shuttle main engine (SSME) systems performance during the sixty-fourth flight of the Space Shuttle Program and the nineteenth flight of the Orbiter vehicle Discovery (OV-103). In addition to the Orbiter, the flight vehicle consisted of an ET that was designated ET-66; three SSMEs that were designated as serial numbers 2031, 2109, and 2029 in positions 1, 2, and 3, respectively; and two SRB's that were designated Bl-068. The RSRM's that were installed in each SRB were designated as 360L041 A for the left SRB, and 360L041 B for the right SRB. The primary objective of this flight was to successfully perform the planned operations of the Lidar In-Space Technology Experiment (LITE), and to deploy the Shuttle Pointed Autonomous Research Tool for Astronomy (SPARTAN) -201 payload. The secondary objectives were to perform the planned activities of the Robot Operated Materials Processing System (ROMPS), the Shuttle Amateur Radio Experiment - 2 (SAREX-2), the Solid Surface Combustion Experiment (SSCE), the Biological Research in Canisters (BRIC) experiment, the Radiation Monitoring Equipment-3 (RME-3) payload, the Military Application of Ship Tracks (MAST) experiment, and the Air Force Maui Optical Site Calibration Test (AMOS) payload.

Fricke, Robert W., Jr.↗

STS-70 Mission Highlights

The highlights of the STS-70 mission are presented in this video. The flight crew consisted of Cmdr. Tom Henricks, Pilot Kevin Kregel, Flight Engineer Nancy Currie, and Mission Specialists Dr. Don Thomas and Dr. Mary Ellen Weber. The mission's primary objective was the deployment of the 7th Tracking Data and Relay Satellite (TDRS), which will provide a communication, tracking, telemetry, data acquisition, and command services space-based network system essential to low Earth orbital spacecraft. Secondary mission objectives included activating and studying the Physiological and Anatomical Rodent Experiment/National Institutes of Health-Rodents (PARE/NIH-R), The Bioreactor Demonstration System (BDS), the Commercial Protein Crystal Growth (CPCG) studies, the Space Tissue Loss/National Institutes of Health-Cells (STL/NIH-C) experiment, the Biological Research in Canisters (BRIC) experiment, Shuttle Amateur Radio Experiment-2 (SAREX-2), the Visual Function Tester-4 (VFT-4), the Hand-Held, Earth Oriented, Real-Time, Cooperative, User-Friendly, Location-Targeting and Environmental System (HERCULES), the Microcapsules in Space-B (MIS-B) experiment, the Windows Experiment (WINDEX), the Radiation Monitoring Equipment-3 (RME-3), and the Military Applications of Ship Tracks (MAST) experiment. There was an in-orbit dedication ceremony by the spacecrew and the newly Integrated Mission Control Center to commemorate the Center's integration. The STS-70 mission was the first mission monitored by this new control center. Earth views included the Earth's atmosphere, a sunrise over the Earth's horizon, several views of various land masses, some B/W lightning shots, some cloud cover, and a tropical storm.

Source record↗

STS-70 Space Shuttle Mission Report - September 1995

The STS-70 Space Shuttle Program Mission Report summarizes the Payload activities as well as the Orbiter, External Tank (ET), Solid Rocket Booster (SRB), Reusable Solid Rocket Motor (RSRM), and the Space Shuttle main engine (SSME) systems performance during the seventieth flight of the Space Shuttle Program, the forty-fifth flight since the return-to-flight, and the twenty-first flight of the Orbiter Discovery (OV-103). In addition to the Orbiter, the flight vehicle consisted of an ET that was designated ET-71; three SSMEs that were designated as serial numbers 2036, 2019, and 2017 in positions 1, 2, and 3, respectively; and two SRBs that were designated 81-073. The RSRMs, designated RSRM-44, were installed in each SRB and were designated as 36OL044A for the left SRB, and 36OL044B for the right SRB. The primary objective of this flight was to deploy the Tracking and Data Relay Satellite-G/Inertial Upper Stage (TDRS-G/IUS). The secondary objectives were to fulfill the requirements of the Physiological and Anatomical Rodent Experiment/National Institutes of Health-Rodents (PARE/NIH-R); Bioreactor Demonstration System (BDS); Commercial Protein Crystal Growth (CPCG) experiment; Space Tissue Loss/National Institutes of Health - Cells (STL/NIH-C) experiment; Biological Research in Canisters (BRIC) experiment; Shuttle Amateur Radio Experiment-2 (SAREX-2); Visual Function Tester-4 (VFT-4); Hand-Held, Earth-Oriented, Real-Time, Cooperative, User-Friendly Location-Targeting and Environmental System (HERCULES); Microencapsulation in Space-B (MIS-B) experiment; Window Experiment (WINDEX); Radiation Monitoring Equipment-3 (RME-3); and the Military Applications of Ship Tracks (MAST) payload.

Fricke, Robert W., Jr.↗

Electron Induced Scintillation Testing of Commercially Available Optical Fibers for Space Flight

A test to verify the performance of several commercial and military optical fibers available on the market today was conducted, via usage of an electron accelerator, to monitor radiation induced scintillation or luminescence. The test results showed that no significant effects could be detected with the PMT system used, above a noise floor of 50 photons/sec that were due to optical fiber scintillation. Although some data appeared to show events taking place, noise scan results have correlated these events to arcing inside the electron accelerator facility. This test was to simply characterize for space flight, which optical fiber candidates were the largest scintillators among the eighteen optical fiber candidates tested.

Ott, Melanie N.↗

STS-31 Mission Highlights Resource Tape

The primary objective of mission STS-31 was to deploy the Hubble Space Telescope. The commander of the mission was Loren J. Shriver. The crew was pilot Charles F. Bolden, and Mission Specialists, Steven A. Hawley, Bruce McCandless II, and Kathryn D. Sullivan. The mission was launched on April 24, 1990. This videotape shows the astronauts at their pre-launch breakfast, their final preparations for launch and boarding the Shuttle Discovery. It shows the launch and the detachment of the rocket boosters. It shows the deployment of the Hubble Telescope and the unfurling of its Solar Arrays. Other payloads include the Protein Crystal Growth (PCG) experiment, and the Radiation Monitoring Equipment III, to measure gamma ray levels in the crew cabin. The videotape shows many shots of the Kennedy Mission Control room and the shuttle cockpit. The videotape finally shows the landing at Edwards Air Force Base, and the crew disembarking the shuttle.

Source record↗

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Chandra Space Flight Software: Using Software to Autonomously Operation the Largest and Most Sensitive X-Ray Telescope in the World

Chandra is the world's largest and most sensitive X-ray telescope. The Chandra X-ray Observatory is the third in NASA's family of "Great Observatories." The Chandra X-ray Observatory, launched by Space Shuttle Columbia on July 23, 1999, is NASA's newest Great Observatory. The Chandra space flight software is the operational software, which controls and directs the Chandra X-ray Observatory. The Chandra flight software has executed faultlessly for over 13,000 hours on-orbit. The Chandra flight software directly controls the Pointing, Aspect Determination, Electrical Power Subsystem, Propulsion system, and the Command, Communications, and Data Management subsystems. The software controls the spacecraft operations during all phases of the mission. The software also performs thermal control of the telescope to maintain pointing accuracy and monitors radiation levels throughout the orbit so that the Science Instruments can be safed if radiation thresholds are exceeded. The efficient operation of Chandra flight software has enabled the gathering of crucial science data. The Chandra flight software fault protection is the key to early detection and prevention of science instrument or spacecraft damage in an operating platform/environment, which is completely unforgiving. Permanently open Sun Shade Door and ACIS focal plane radiator sensitivity exposes science instruments and mirrors to damage for pointing anomalies causing an attitude excursion. The Chandra flight software must prevent these attitude excursions from occurring for ANY failure. Another example is that the power system has an unregulated bus, which imposes severe operating requirements on Chandra flight software to control array pointing and battery connection/disconnect using a unique algorithmic and logic approach. The Chandra flight software has enabled a truly autonomous vehicle with greater than 99% of all mission data collected as planned. Less than 15% of spacecraft operations are conducted in view (1 hour out of 8) leading to very extended periods without ground contact. The Chandra flight software implements the flexible mission plan during this out of view period, manages the solid state recorder capacity, controls all pointing and maneuvers, provides fault detection for all satellite subsystems, and initiates communications with the ground at the appropriate time. This paper will describe the software architecture features, key design elements and software testing techniques that have facilitated Chandra's success.

Crumbley, Tim↗

CZT Imaging Arrays for Space Applications

The compound CZT offers great promise for space applications with applications in such areas as radiation monitoring, planetary investigations and astrophysics. As crystal quality improves, the challenge for imaging array development is to derive electrode geometries and readout electronics to satisfy particular applications and to understand how the material will perform in the space environment. An overview of present and future detector requirements will be given together with the status of current array developments.

Ramsey, Brian D.↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

VTXO: the Virtual Telescope for X-ray Observations

The Virtual Telescope for X-ray Observations (VTXO) will use lightweight Phase Frensel Lenses (PFLs) in a virtual X-ray telescope with 1 km focal length and with nearly 50 milli-arcsecond angular resolution. Laboratory characterization of PFLs have demonstrated near diffraction-limited angular resolution in the X-ray band, but they require long focal lengths to achieve this quality of imaging. VTXO is formed by using precision formation flying of two SmallSats: a smaller, 6U OpticsSat that houses the PFLs and navigation beacons while a larger, ESPA-class DetectorSat contains an X-ray camera, a charged-particle radiation monitor, a precision star tracker, and the propulsion for the formation flying. The baseline flight dynamics uses a highly-elliptical supersynchronous geostationary transfer orbit to allow the inertial formation to form and hold around the 90,000 km apogee for 10 hours of the 32.5-hour orbit with nearly a year mission lifetime. The guidance, navigation, and control (GN&C) for the formation flying uses standard CubeSat avionics packages, a precision star tracker, imaging beacons on the Optics Sat, and a radio ranging system that also serves as an inter-satellite communication link. VTXO’s fine angular resolution enables measuring the environments nearly an order of magnitude closer to the central engines of bright compact X-ray sources compared to the current state of the art. This X-ray imaging capability allows for the study of the effects of dust scattering nearer to the central objects such as Cyg X-3 and GX 5-1, for the search for jet structure nearer to the compact object in X-ray novae such as Cyg X-1and GRS 1915+105, and for the search for structure in the termination shock of in the Crab pulsar wind nebula. The In this paper, the VTXO science performance, SmallSat and instrument designs,and mission description is be described. The VTXO development was supported as one of the selected 2018 NASA Astrophysics SmallSat Study (AS3) missions.

John Krizmanic↗

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Finding Beam Loss Locations at PIP2IT Accelerator With Oscillating Dipole Correctors

The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H- beam to 16 MeV. To determine location of the beam loss in the accelerators low-energy part, where radiation monitors are ineffective, a method using oscillating trajectories was implemented. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync, produces a line at the corresponding frequency in spectra of BPM sum signals downstream of the loss point. Comparison of these responses along the beam line allows to find the loss location. The paper describes the method and results of its implementation at PIP2IT.

43 PARTICLE ACCELERATORS↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers: Preprint

The World Radiation Center at PMOD/WRC is operated on behalf of the WMO. The Infrared Radiometry Section of the WRC (WRC-IRS) provides traceability of downwelling atmospheric longwave radiation measured with pyrgeometers by comparison to the World Infrared Standard Group (WISG) [1]. As has been discussed previously [2], the current implementation of the WISG measures lower longwave irradiances than the two candidate reference radiometers IRIS (Infrared Integrating Sphere Radiometer) and the ACP (Absolute Cavity Pyrgeometer). To validate the findings reported in [2], additional measurements since that publication in 2014 have been performed and are discussed in this paper. Specifically, Measurements during cloud-free nights at PMOD/WRC between the WISG and IRIS radiometers, A field campaign at the Atmospheric Radiation Monitoring Site (ARM) at Southern Great Plains, Oklahoma with IRIS, ACP, AERI (Atmospheric Emittance Radiance Interferometer) and WISG traceable pyrgeometers, Laboratory comparison between the reference blackbody of PMOD/WRC with the hemispherical blackbody developed by PTB.

ACR↗

In-Situ Approach to Sampling and Survey for Radiological Contaminants to Release Overburden Soil for Reuse - 20120

Various methods may be utilized to determine if overburden soil meets approved release criteria to allow for reuse of overburden soil as backfill material: soil scanning and sorting equipment, survey and sampling of excavated soil, in-situ sampling, and utilization of box or truck counters are common approaches. This paper focuses on a modified approach using elements of in-situ sampling and after excavation survey for a large volume of overburden soil that was expected to meet soil release criteria. This approach was utilized for the U.S. Army Corps of Engineers (USACE) St. Louis District at a North St. Louis County property. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗