Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Asymmetrical SRAM Cells For Radiation Tests

Features of circuits altered to increase or decrease sensitivity to radiation. State-space analysis used to analyze single-event-upset behavior of memory cell. When voltage on node a is set at one of indicated initial values Vao and then released, voltages on nodes a and b then follow indicated trajectory to final logic "one" or logic "zero" state. Ability to do this important for design of radiation-detecting integrated circuits (deliberately made more sensitive to ionizing radiation) and "radiation-hardened" integrated circuits - those intended to be relatively invulnerable to intense radiation.

Buehler, Martin G.↗

Radiation detectors employing contemporaneous detection and decontamination

Radiation detectors and methods of using the radiation detectors that provide a route for surface decontamination during use are described. The detectors utilize light illumination of an internal surface during use. Light is in the longer UV to near-infrared spectra and desorbs contamination from internal surfaces of radiation detectors. The methods can be carried out while the detectors are in operation, preventing the appearance of the negative effects of radioactive and non-radioactive contamination during a detection regime and following a detection regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation detectors employing contemporaneous detection and decontamination

Radiation detectors and methods of using the radiation detectors that provide a route for surface decontamination during use are described. The detectors utilize light illumination of an internal surface during use. Light is in the longer UV-to-near-infrared spectra and desorbs contamination from internal surfaces of radiation detectors. The methods can be carried out while the detectors are in operation, preventing the appearance of the negative effects of radioactive and non-radioactive contamination during a detection regime and following a detection regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino charge radius and additional one-loop radiative corrections at ultranear reactor experiments

We scrutinize the potential of upcoming ultranear reactor neutrino experiments to detect radiative corrections in the elastic neutrino-electron scattering channel, focusing on the JUNO-TAO and CLOUD detectors, which employ advanced scintillator detection technologies. Previous reactor experiments have already constrained the electron neutrino charge radius, which is a neutrino property associated with a certain subset of the total radiative corrections, and have achieved limits that are only about an order of magnitude away from the Standard Model prediction. Our study demonstrates that JUNO-TAO and CLOUD could discover the neutrino charge radius in the near future, considering the established treatment of the charge radius. However, we show that it is necessary to go beyond this standard treatment. By including the complete set of one-loop level radiative corrections, we find a partial cancellation with the charge radius effect, reducing the experimental sensitivity to this quantity. Nevertheless, JUNO-TAO and CLOUD still have the potential to achieve a 5 σ discovery but over longer timescales within a reasonable operational time frame. Published by the American Physical Society 2024

Brdar, Vedran (ORCID:0000000170275104)↗

MCNP ® Code V.6.3.0 Release Notes

The Monte Carlo N-Particle ® (MCNP ® ) code is a general-purpose, continuous-energy, generalized geometry, time-dependent, radiation transport code developed by the MCNP development team. The MCNP calculations provide predictive capabilities that can replace expensive or impossible-to perform experiments. Specific application problems include simulations of experimental diagnostics, intrinsic radiation, radiation detection and measurement, criticality safety, nuclear threat reduction and response, radiation health protection, nuclear weapons effects, and nuclear forensics. This MCNP code, version 6.3.0, follows the MCNP6.2.0 version. Since the release of MCNP6.2.0, many changes have been made to the MCNP code. These changes include new or improved features, a new build system, code enhancement and modernization, and bug fixes. The MCNP code, version 6.3.0, theory and user input information is documented in MCNP ® Code Version 6.3.0 Theory & User Manual, the build guidance for various platforms is documented in MCNP ® Code Version 6.3.0 Build Guide, and the verification and validation testing for various application benchmark test suites is documented in MCNP ® Code Version 6.3.0 Verification & Validation Testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP® Code Version 6.3.1 Release Notes

The Monte Carlo N-Particle® (MCNP® ) code is a general-purpose, continuous-energy, generalized-geometry, time-dependent, radiation transport code developed by the MCNP development team. MCNP calculations provide predictive capabilities that can replace expensive or impossible-to-perform experiments. Specific application problems include simulations of experimental diagnostics, intrinsic radiation, radiation detection and measurement, criticality safety, nuclear threat reduction and response, radiation health protection, nuclear weapons effects, and nuclear forensics. This MCNP code, version 6.3.1, follows the MCNP6.3.0 version. Since the release of MCNP6.3.0, a variety of bug fixes and code enhancements have been completed for MCNP6.3.1. A few new features have also been added to this release to support both ongoing research and the release of the latest ENDF/B-VIII.1 nuclear data library. The MCNP code, version 6.3.1, theory and user input information is documented in MCNP® Code Version 6.3.1 Theory & User Manual, the build guidance for various platforms is documented in MCNP® Code Version 6.3.1 Build Guide, and the verification and validation testing for various application benchmark test suites is documented in MCNP® Code Version 6.3.1 Verification & Validation Testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid-State Personal Dosimetry

This document is a web site page, and a data sheet about Personal protection (i.e., space suits) presented to the Radiation and Micrometeoroid Mitigation Technology Focus Group meeting. The website describes the work of the PI to improve solid state personal radiation dosimetry. The data sheet presents work on the active personal radiation detection system that is to provide real-time local radiation exposure information during EVA. Should undue exposure occur, knowledge of the dynamic intensity conditions during the exposure will allow more precise diagnostic assessment of the potential health risk to the exposed individual.

Wrbanek, John D.↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Electrification in winter storms and the analysis of thunderstorm overflight data

We have been focusing our study of electrification in winter storms on the lightning initiation process, making inferences about the magnitude of the electric fields from the initial pulses associated with breakdown, i.e., with the formation of the initial streamers. The essence of the most significant finding is as follows: (1) initial breakdown radiation pulses from stepped leaders prior to the first return stroke are very large, reaching values of 20-30 Volts/meter, comparable to return stroke radiation; and (2) the duration of the stepped leader, from the initial detectable radiation pulse to the return stroke onset, is very-short-ranging from a minimum 1.5 ms to a maximum of 4.5 ms. This past summer (June-August of 1991) we participated in the CAPE program at the Kennedy Space Center in order to acquire data on stepped leaders in summer storms with the same equipment used to get the winter storm data. We discovered that the vigorous leaders seen in winter so frequently were present in summer storms, although not as large in amplitude and certainly not as frequent.

Brook, Marx↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Case Study of Using High Performance Commercial Processors in a Space Environment

The purpose of the Space Shuttle Cockpit Avionics Upgrade project was to reduce crew workload and improve situational awareness. The upgrade was to augment the Shuttle avionics system with new hardware and software. A major success of this project was the validation of the hardware architecture and software design. This was significant because the project incorporated new technology and approaches for the development of human rated space software. An early version of this system was tested at the Johnson Space Center for one month by teams of astronauts. The results were positive, but NASA eventually cancelled the project towards the end of the development cycle. The goal to reduce crew workload and improve situational awareness resulted in the need for high performance Central Processing Units (CPUs). The choice of CPU selected was the PowerPC family, which is a reduced instruction set computer (RISC) known for its high performance. However, the requirement for radiation tolerance resulted in the reevaluation of the selected family member of the PowerPC line. Radiation testing revealed that the original selected processor (PowerPC 7400) was too soft to meet mission objectives and an effort was established to perform trade studies and performance testing to determine a feasible candidate. At that time, the PowerPC RAD750s where radiation tolerant, but did not meet the required performance needs of the project. Thus, the final solution was to select the PowerPC 7455. This processor did not have a radiation tolerant version, but faired better than the 7400 in the ability to detect failures. However, its cache tags did not provide parity and thus the project incorporated a software strategy to detect radiation failures. The strategy was to incorporate dual paths for software generating commands to the legacy Space Shuttle avionics to prevent failures due to the softness of the upgraded avionics.

Ferguson, Roscoe C.↗

Advanced X-ray emission spectrometers

Spectroscopy systems require a crystal having specific properties for analyzing a spectrum of a sample, which is typically performed for measuring the presence of one element at a time. A two-dimensional (2D) crystal mount for performing simultaneous spectroscopy measurements includes a crystal holder having multiple rows of crystal mounts. Each crystal mount is positioned and orientated to physically support a crystal at a fixed position and fixed orientation relative to an optical axis. A sample provides radiation to analyzer crystals disposed in the crystal mounts, and a detector may detect radiation reflected from the analyzer crystals, for performing multiple simultaneous spectroscopy measurements.

Sun, Chengjun↗

A review of radiation-induced damage to quantum dots

Quantum dots (QDs) are versatile nano structures that have applications in many fields of research and production, including biosensor technology, computing, photovoltaics, and optoelectronics. QDs have gained interest in the field of radiation detection because of their relative ease of production, tunable photoluminescence, and sensitivity to ionizing radiation. The photoluminescent properties of QDs diminish proportionally to prolonged ionizing radiation interactions, leading many groups to seek out these materials as potential candidates for the next generation of inexpensive, easily manufactured dosimetry and sensors. To use QDs in these applications, the mechanisms of radiation damage to the nanomaterial must be clearly understood and characterized. Herein, we review the study of ionizing radiation damage to QDs. First, the synthesis and properties of QDs are briefly discussed. Next, the radiation damage to QDs due to heavy charged particles, fast electrons, high energy photons, and neutrons are detailed. After this, experimental methods and modelling of QDs in radiation environments are examined. Lastly, future research directions are provided. The goal of this review is to aid in understanding the ionizing radiation effects on QD-based devices.

Snow, Jesse [University of Utah, Salt Lake City, U↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗