Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RUPTURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Stress-Rupture of New Tyranno Si-C-O-Zr Fiber Reinforced Minicomposites

Minicomposites consisting of two varieties of Zr containing SiC-based fibers from Ube (Tyranno) with BN interphases and CVI SiC matrices were studied. The two fiber-types were the ZMI and ZE fiber-types that contain approximately 8 and 2% oxygen, respectively. The minicomposites were precracked and tested under constant load testing at temperatures ranging from 700 to 1200 C. The data were then compared to the rupture behavior of Hi- Nicalon (TM) fiber reinforced minicomposites tested under identical conditions. It was found that the Ube fiber-types had stress rupture life equivalent to Hi- Nicalon (TM) over the entire temperature range. A potential benefit of the ZMI fiber-type is that it offers rupture properties almost as good as Hi-Nicalon (TM) at the cost of ceramic grade Nicalon (TM).

Morscher, Gregory N.↗

Growth of Matrix Cracks During Intermediate Temperature Stress Rupture of a SiC/SiC Composite in Air

The crack density of woven Hi-Nicalon(sup TM) (Nippon Carbon, Japan) fiber, BN interphase, melt-infiltrated SiC matrix composites was determined for specimens subjected to tensile stress rupture at 815 C. A significant amount of matrix cracking occurs due to the growth of fiber-bridged microcracks even at stresses below the run-out condition. This increased cracking corresponded to time dependent strain accumulation and acoustic emission activity during the constant load test. However, the portion of the rupture specimens subjected to cooler temperatures (< 600 C than the hot section had significantly lower crack densities compared to the hotter regions. From the acoustic emission and time dependent strain data it can be inferred that most of the matrix crack growth occurred within the first few hours of the tensile rupture experiment. The crack growth was attributed to an interphase recession mechanism that is enhanced by the presence of a thin carbon layer between the fiber and the matrix as a result of the composite fabrication process. One important consequence of matrix crack growth at the lower stresses is poor retained strength at room temperature for specimens that did not fail.

Morscher, Gregory N.↗

Long-Wavelength Rupturing Instability in Surface-Tension-Driven Benard Convection

A liquid layer with a free upper surface and heated from below is subject to thermocapillary-induced convective instabilities. We use very thin liquid layers (0.01 cm) to significantly reduce buoyancy effects and simulate Marangoni convection in microgravity. We observe thermocapillary-driven convection in two qualitatively different modes, short-wavelength Benard hexagonal convection cells and a long-wavelength interfacial rupturing mode. We focus on the long-wavelength mode and present experimental observations and theoretical analyses of the long-wavelength instability. Depending on the depths and thermal conductivities of the liquid and the gas above it, the interface can rupture downwards and form a dry spot or rupture upwards and form a high spot. Linear stability theory gives good agreement to the experimental measurements of onset as long as sidewall effects are taken into account. Nonlinear theory correctly predicts the subcritical nature of the bifurcation and the selection between the dry spot and high spots.

Swift, J. B.↗

Stress-Rupture and Stress-Relaxation of SiC/SiC Composites at Intermediate Temperature

Tensile static stress and static strain experiments were performed on woven Sylramic (Dow Corning, Midland, MI) and Hi-Nicalon (Nippon Carbon, Japan) fiber reinforced, BN interphase, melt-infiltrated SiC matrix composites at 815 C. Acoustic emission was used to monitor the damage accumulation during the test. The stress-rupture properties of Sylramic composites were superior to that of Hi-Nicalon Tm composites. Conversely, the applied strain levels that Hi-Nicalon composites can withstand for stress-relaxation experiments were superior to Sylramic composites; however, at a cost of poor retained strength properties for Hi-Nicalon composites. Sylramic composites exhibited much less stress-oxidation induced matrix cracking compared to Hi-Nicalon composites. This was attributed to the greater stiffness and roughness of Sylramic fibers themselves and the lack of a carbon layer between the fiber and the BN interphase for Sylramic composites, which existed in Hi-Nicalon composites. Due to the lack of stress-relief for Sylramic composites, time to failure for Sylramic composite stress-relaxation experiments was not much longer than for stress-rupture experiments when comparing the peak stress condition for stress-relaxation with the applied stress of stress-rupture.

Morscher, Gregory N.↗

Effect of Environment on the Stress- Rupture Behavior of a C/SiC Composite Studied

Advanced reusable launch vehicles will likely incorporate fiber-reinforced ceramic matrix composites (CMC's) in critical propulsion and airframe components. The use of CMC's is highly desirable to save weight, improve reuse capability, and increase performance. One of the candidate CMC materials is carbon-fiber-reinforced silicon carbide (C/SiC). In potential propulsion applications, such as turbopump rotors and nozzle exit ramps, C/SiC components will be subjected to a service cycle that includes mechanical loading under complex, high-pressure environments containing hydrogen, oxygen, and steam. Degradation of both the C fibers and the SiC matrix are possible in these environments. The objective of this effort was to evaluate the mechanical behavior of C/SiC in various environments relevant to reusable launch vehicle applications. Stress-rupture testing was conducted at the NASA Glenn Research Center on C/SiC specimens in air and steam-containing environments. Also, the oxidation kinetics of the carbon fibers that reinforce the composite were monitored by thermogravimetric analysis in the same environments and temperatures used for the stress-rupture tests of the C/SiC composite specimens. The stress-rupture lives obtained for C/SiC tested in air and in steam/argon mixtures are shown in the following bar chart. As is typical for most materials, lives obtained at the lower temperature (600 C) are longer than for the higher temperature (1200 C). The effect of environment was most pronounced at the lower temperature, where the average test duration in steam at 600 C was at least 30 times longer than the lives obtained in air. The 1200 C data revealed little difference between the lives of specimens tested in air and steam at atmospheric pressure.

Verrilli, Michael J.↗

ICESat Observations of Topographic Change in the Northern Segment of the 2004 Sumatra-Andaman Islands Earthquake Rupture Zone

The Andaman Islands are located 120 km east of the Sunda trench in the northern quarter of the 1300 km long rupture zone of the 2004 Sumatra-Andaman Islands earthquake inferred from the distribution of aftershocks. Initial field reports indicate that several meters of uplift and up to a meter of submergence occurred on the western and eastern shorelines of the Andaman Islands, respectively, associated with the earthquake (Bilham, 2005). Satellite images also document uplift of western shoreline coral reef platforms above sea level. Body-wave (Ji, 2005; Yamamaka, 2005) and tide-gauge (Ortiz, 2005) slip inversions only resolve coseismic slip in the southern one-third to one-half of the rupture zone. The amount of coseismic slip in the Andaman Islands region is poorly constrained by these inversions. The Ice, Cloud, and land Elevation Satellite (ICESat), a part of the NASA Earth Observing System, is being used to document the spatial pattern of Andaman Islands vertical displacements in order to constrain models of slip distribution in the northern part of the rupture zone. ICESat carries the Geoscience Laser Altimeter System (GLAS) that obtains elevation measurements from 80 m diameter footprints spaced 175 m apart along profiles. For surfaces of low slope, single-footprint absolute elevation and horizontal accuracies of 10 cm and 6 m (1 sigma), respectively, referenced to the ITRF 2002 TOPEX/Poseidon ellipsoid are being obtained. Laser pulse backscatter waveforms enable separation of ground topography and overlying vegetation cover. During each 33-day observing period ICESat acquires three profiles crossing the Andaman Islands. A NNE-SSW oriented track consists of 1600 laser footprints along the western side of North, Middle, and South Andaman Islands and 240 laser footprints across the center of Great Andaman Island. Two NNW-SSE tracks consist of 440 footprints across Middle Andaman Island and 25 footprints across the west side of Sentinel Island. Cloud-free profiles were acquired in the fall of 2003 and 2004. During February-March, 2005 ICESat's precise pointing capability will be used to exactly repeat these three profiles, with a cross-track accuracy of better than 100 m, providing trench- parallel and -perpendicular observations of topographic change of the Andaman Islands that will compliment geodetic field surveys. The observed elevation changes will be compared to models of coseismic deformation associated with the mainshock and large aftershocks in the Andaman Islands region.

Harding, David↗

Composite Overwrapped Pressure Vessel (COPV) Stress Rupture Testing

This paper reports stress rupture testing of Kevlar(TradeMark) composite overwrapped pressure vessels (COPVs) at NASA White Sands Test Facility. This 6-year test program was part of the larger effort to predict and extend the lifetime of flight vessels. Tests were performed to characterize control parameters for stress rupture testing, and vessel life was predicted by statistical modeling. One highly instrumented 102-cm (40-in.) diameter Kevlar(TradeMark) COPV was tested to failure (burst) as a single-point model verification. Significant data were generated that will enhance development of improved NDE methods and predictive modeling techniques, and thus better address stress rupture and other composite durability concerns that affect pressure vessel safety, reliability and mission assurance.

Greene, Nathanael J.↗

A Critique of a Phenomenological Fiber Breakage Model for Stress Rupture of Composite Materials

Stress rupture is not a critical failure mode for most composite structures, but there are a few applications where it can be critical. One application where stress rupture can be a critical design issue is in Composite Overwrapped Pressure Vessels (COPV's), where the composite material is highly and uniformly loaded for long periods of time and where very high reliability is required. COPV's are normally required to be proof loaded before being put into service to insure strength, but it is feared that the proof load may cause damage that reduces the stress rupture reliability. Recently, a fiber breakage model was proposed specifically to estimate a reduced reliability due to proof loading. The fiber breakage model attempts to model physics believed to occur at the microscopic scale, but validation of the model has not occurred. In this paper, the fiber breakage model is re-derived while highlighting assumptions that were made during the derivation. Some of the assumptions are examined to assess their effect on the final predicted reliability.

Reeder, James R.↗

Lessons Learned from Recent Rapid Imaging of Earthquake Ruptures with Satellite Geodesy

Rapid determination of the location and extent of earthquake ruptures at the surface and at depth is helpful for disaster response, as it allows prediction of the likely area of major damage from the earthquake and can help with rescue and recovery planning. The Caltech-Jet Propulsion Laboratory (JPL) Advanced Rapid Imaging and Analysis (ARIA) project has responded to many recent large earthquakes to process geodetic data and help determine the location and extent of ruptures. With the increasing availability of near real-time data from the Global Positioning System (GPS) and other global navigation satellite system receivers in active tectonic regions, and with the shorter repeat times of many recent and newly launched radar satellites, geodetic data can now be obtained quickly after earthquakes or other disasters. We have been building an ARIA data system that can ingest, catalog, and process geodetic data and combine it with seismic analysis to estimate the fault rupture locations and slip distributions for large earthquakes that are on or near land.

Simons, Mark↗

Cascading Rupture of a Megathrust

Understanding variability in the size and location of large earthquakes along subduction margins is crucial for evaluating seismic and tsunami hazards. We present a coseismic slip model for the 2021 M8.2 Chignik earthquake and investigate the relationship of this earthquake to previous major events in the Alaska Peninsula region and to interseismic coupling. Stress changes from the 2020 M7.8 Simeonof event triggered the Chignik event, and together, the earthquakes partially filled an unruptured section along a 3000-km subduction margin that has experienced a series of ruptures along almost its entire length over the past century. Variations in coupling and structural characteristics may make the region more prone to nucleating M7 to M8 events rather than larger M > 8.5 earthquakes. Stress changes and rupture areas suggest that the two recent earthquakes may be part of an 80-year-long rupture cascade and may have advanced seismic hazard in the region.

Julie L. Elliott↗

Off-fault deformations and shallow slip deficit from dynamic rupture simulations with fault zone plasticity

Kinematic source inversions of major (M≥7) strike-slip earthquakes show that the slip at depth exceeds surface displacements measured in the field, and it has been suggested that this shallow slip deficit (SSD) is caused by distributed plastic deformation near the surface. We perform dynamic rupture simulations of M 7.2–7.4 earthquakes in elastoplastic media and analyze the sensitivity of SSD and off-fault deformation (OFD) to rock quality parameters. While linear simulations clearly underpredict observed SSD and OFDs, nonlinear simulations for a moderately fractured fault damage zone predict a SSD of 44–53% and OFDs of 39–48%, consistent with the 30–60% SSD and 46 ± 10% (1σ) OFD reported for the 1992 M 7.3 Landers earthquake. Finally, both SSD and OFDs are sensitive to the quality of the fractured rock mass inside the fault damage zone, and surface rupture is almost entirely suppressed in poor quality material.

58 GEOSCIENCES↗

Massive Hemoperitoneum Caused by Rupture of an Aneurysm of the Marginal Artery of Drummond

Aneurysms of visceral arteries are uncommon and their rupture is rare. We report a case of an aneurysm of the marginal artery of Drummond, which was complicated by rupture leading to massive hemoperitoneum. A selective superior mesenteric arteriogram suggested the possibility of segmental arterial mediolysis (SAM) as a possible etiology and this was confirmed by histological examination. This is the first report of symptomatic SAM of the marginal artery of Drummond to date. This case demonstrates that the marginal artery of Drummond should be considered during the angiographic explorations for the source of hemoperitoneum. Management options are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rupture and Migration of an Endovascular Stent in the Brachiocephalic Trunk Causing a Vertebral Steal Syndrome

Delayed stent fracture has been observed in many different arteries and may represent a risk factor for restenosis. We describe the case of a delayed rupture of an endovascular brachiocephalic trunk stent. The complete fracture allowed a fragment to migrate distally and tilt, resulting in a hemodynamic pattern similar to that of a prevertebral stenosis with complete inversion of the homolateral vertebral blood flow. The induced vertebral steal syndrome as well as the risk of cerebral embolism was corrected by an aortobrachiocephalic bypass and resection of the ruptured stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Sac Rupture in Abdominal Aortic Aneurysms Previously Excluded with Endovascular Repair (EVAR)

The purpose of this study was to assess the feasibility and effectiveness of percutaneous endovascular repair of ruptured abdominal aortic aneurysms (AAAs) previously treated by EVAR. In the last year, two male patients with AAAs, treated 8 and 23 months ago with bifurcated stent-graft, were observed because of lumbar pain and hemorragic shock. Multidetector computed tomography (MDCT) showed a retroperitoneal hematoma; in both cases a type III endoleak was detected, in one case associated with a type II endoleak from the iliolumbar artery. The procedures were performed in the theater, in emergency. Type II endoleak was treated with transcatheter superselective glue injection; type III endoleaks were excluded by a stent-graft extension. The procedures were successful in both patients, with immediate hemodynamic stabilization. MDCT after the procedure showed complete exclusion of the aneurysms. In conclusion, endovascular treatment is a safe and feasible option for the treatment of ruptured AAAs previously treated by EVAR; this approach allows avoidance of surgical conversion, which is technical very challenging, with a high morbidity and mortality rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Intrahepatic Artery Aneurysms in a Patient with Behcet's Disease: Use of Transcatheter Embolization for Rupture

Intrahepatic artery aneuryms are a rare and potentially life-threatening condition. We present the first case in the English literature of multiple intrahepatic artery aneuryms in a patient with Behcet's disease who presented acutely with rupture. The ruptured aneurysm was treated successfully with transcatheter arterial coil embolization-CT and clinical follow-up confirming a good result. We discuss the management dilemma with regard to prophylactic embolization of the numerous other small asymptomatic intrahepatic aneurysms in this same patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spontaneous Liver Rupture After Treatment With Drug-Eluting Beads

Spontaneous rupture of hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE) is a rare and life-threatening complication. Pathophysiologic mechanisms are not yet fully known; it is suggested that rupture is preceded by reactive tissue edema and intratumerous bleeding, leading to a rapid expansion of tumour mass with risk of extrahepatic bleeding in the case of subcapsular localisation. This case report discusses a sudden, unexpected lethal complication in a 74 year-old male patient treated with TACE using DC Bead loaded with doxorubicin (DEBDOX) in a progressive multifocal HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗