Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Rare‐Earth Reduction in High‐Speed PM‐Assisted Synchronous Reluctance Motors Using Hybrid Magnet Strategies and Design Optimisation for 800 V EVs

The trend towards electrifying transportation systems has stimulated research endeavours aimed at developing electric machines that are not only high speed and efficient but also low‐cost and compact. To support this transition, the US Department of Energy (DOE) has established ambitious targets of $7/kW cost and 12 kW/L power density for the electric drivetrains. This paper attempts to meet these targets by proposing high‐speed permanent magnet assisted synchronous reluctance machine (PMASynRM) topologies enabled by hybrid magnet strategies, combining rare‐earth (RE) magnets with low‐cost, RE‐free alternatives. Modified 2‐layer and 3‐layer U‐shaped rotor configurations, featuring structural reinforcements to withstand high mechanical stress at elevated speeds, are developed. A multi‐objective design optimisation framework is employed to optimise the rotor design, targeting reductions in RE magnet volume, magnet demagnetisation risk and torque ripple while achieving the desired electromagnetic performance. A comprehensive analysis of the optimised rotor designs, compared against a 16,000 rpm, 800 V baseline IPM motor, shows over 70% RE reduction, demagnetisation risk below 3.5% and torque ripple under 10%. Detailed analyses of performance trends across various magnet combinations and rotor configurations highlight the viability of hybrid magnet PMASynRM designs as cost‐effective, robust and energy‐efficient solutions for next‐generation EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Blockage and speedup in the proximity of an onshore wind farm: A scanning wind LiDAR experiment

To maximize the profitability of wind power plants, wind farms are often characterized by high wind turbine density leading to operations with reduced turbine spacing. As a consequence, the overall wind farm power capture is hindered by complex flow features associated with flow modifications induced by the various wind turbine rotors. In addition to the generation of wakes, the velocity of the incoming wind field can reduce due to the increased pressure in the proximity of a single turbine rotor (named induction); a similar effect occurs at the wind-farm level (global blockage), which can have a noticeable impact on power production. On the other hand, intra-wind-farm regions featuring increased velocity compared to the freestream (speedups) have also been observed, which can be a source for a potential power boost. To quantify these rotor-induced effects on the incoming wind velocity field, three profiling LiDARs and one scanning wind LiDAR were deployed both before and after the construction of an onshore wind turbine array. The different wind conditions are classified according to the ambient turbulence intensity and streamwise/spanwise spacing among wind turbines. The analysis of the mean velocity field reveals enhanced induction and speedup under stably stratified atmospheric conditions. Additionally, a reduced horizontal area between adjacent turbines has a small impact on the induction zone but increases significantly the speedup between adjacent rotors.

17 WIND ENERGY↗

Longitudinal coherence and short-term wind speed prediction based on a nacelle-mounted Doppler lidar

The spatial structure of turbulence in atmospheric boundary layer flows is highly relevant to wind energy. In particular, wind turbine control strategies based on inflow preview measurements require knowledge of the longitudinal evolution of turbulent flow as it approaches the rotor. These upstream measurements are usually obtained with nacelle-mounted wind lidars. In contrast to traditional in situ anemometry, lidars collect measurements within a probe volume which varies in size depending on the technology of the commercial system being used. Here, we address two issues related to the use of wind lidar to measure the incoming flow to a wind turbine: (i) whether existing longitudinal coherence models can be used to predict flow at the rotor, based on measurements performed at a distance away from the rotor; and (ii) what effect probe-volume averaging has on the inflow predictions. These two questions are critical to the design and implementation of robust wind turbine control strategies. To address these questions, we perform field measurements and large-eddy simulations to determine which incoming flow structures can be readily predicted with existing coherence models, and which require additional corrections to account for lidar volumetric averaging effects. Results reveal that the wind turbine induction zone has a negligible impact on the longitudinal coherence and first-order turbulence quantities, such as the standard deviation of velocity fluctuations. However, the phase of the signal, from which advection time periods of the turbulent structures are derived, is affected by the rotor blockage effect.

17 WIND ENERGY↗

Validation of FAST.Farm Against Full-Scale Turbine SCADA Data for a Small Wind Farm

FAST.Farm is a new midfidelity engineering tool developed by the National Renewable Energy Laboratory targeted at accurately and efficiently predicting wind turbine power production and structural loading in wind farm settings, including wake interactions between turbines. FAST.Farm is based on some of the principles of the Dynamic Wake Meandering model—including passive tracer modeling of wake meandering—but addresses many of the limitations of previous Dynamic Wake Meandering (DWM) implementations. Previous FAST.Farm verification studies show the similarities and differences between FAST.Farm and large-eddy simulations for rigid and flexible turbines. In this validation study, FAST.Farm turbine responses are compared to multiturbine measurements from a subset of a full-scale wind farm. FAST.Farm predictions of turbine generator power, rotor speed, and blade pitch for five-turbine simulations are compared to supervisory control and data acquisition results. Results reveal that FAST.Farm generator power mean and standard deviation results reasonably match measured data for upstream and downstream turbines, as well as the mean rotor speed and blade pitch above rated wind speeds. However, FAST.Farm generally underpredicts the mean rotor speed and overpredicts the mean blade pitch below rated operation. These errors are likely related to inaccuracies in the generic controller simulated. Despite controller differences, FAST.Farm predicts the same overall relative rotor power trends for all waked turbines at all wind speeds.

17 WIND ENERGY↗

Efficient Loads Surrogates for Waked Turbines in an Array

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

17 WIND ENERGY↗

Optimization and Comparison of Modern Offshore Wind Turbine Generators Using GeneratorSE 2.0

As the offshore wind industry keeps growing at a rapid pace, developers are bracing themselves for a huge demand in critical rare earth metals which will threaten an already vulnerable supply chain. The wind energy industry is addressing this problem by investing in modern generator technologies that employ magnets with reduced rare earth content and high-field magnets enabled by rare-earth-free superconductors. In this paper we introduce the National Renewable Energy Laboratory's newly advanced GeneratorSE 2.0, which is a design and optimization tool that was developed to investigate the feasibility of such modern generators. Two direct-drive generator topologies with different magnet materials and mounting arrangements are investigated: an outer-rotor, V-shaped interior permanent magnet generator, and an inner-rotor normally conducting armature, paired with a low-temperature superconducting field with race-track coils. These technologies were evaluated for a range of power ratings between 15 and 25 MW, which represent the next generation of offshore wind turbines for both fixed-bottom and floating applications. The analyses indicate a new trend favoring the low-temperature superconducting technology for the direct-drive system.

direct-drive generators↗

High-Fidelity Simulation Study of the Unsteady Flow Effects on High-Pressure Turbine Blade Performance

Abstract Unsteadiness, in the form of both broadband background disturbances and discrete coherent wakes, can have a strong effect on the performance of turbomachinery blades. The influence of the incoming flow has received much interest as it inevitably affects the blade boundary layers and develops as it passes through the machine. In the present work, we investigate the effect of unsteady flow on high-pressure turbines (HPTs), using high-fidelity datasets produced by wall resolved large-eddy simulation of an HPT stage. The effects of incident wakes from an upstream stator, compounded by the presence of freestream turbulence, on the downstream rotor are investigated. Based on analyzing cases with different turbulence intensities and length scales prescribed at the inlet, we show that changing the freestream turbulence characteristics has a direct effect on the unsteady behavior of the stator wakes. As a result, the performance of the rotor is also significantly affected. By detailing the influence of the wake–turbulence interaction, we aim to distinguish driving forces on rotor performance, be it changes in the incident wakes or direct influence from the freestream turbulence. Furthermore, the aerothermal behaviors of the rotor blades have been extensively investigated, showing that the blade boundary layers on the suction and pressure sides respond differently to external disturbances. The insights gained can provide designers with guidelines in understanding the unsteady flow effects of a given flow state, and how the unsteadiness present, either broadband or deterministic, will affect the performance of downstream blades.

Engineering↗

Aero-structural design and optimization of 50 MW wind turbine with over 250-m blades

The quest for reduced levelized cost of energy has driven significant growth in wind turbine size; however, larger rotors face significant technical and logistical challenges. The largest published rotor design is 25 MW, and here we consider an even larger 50 MW design with blade length over 250 m. This paper shows that a 50 MW design is indeed possible from a detailed engineering perspective and presents a series of aero-structural blade designs, and critical assessment of technology pathways and challenges for extreme-scale rotors. The 50 MW rotor design begins with Monte Carlo simulations focused on optimizing carbon spar cap and root design. A baseline design resulted in a 250-m blade with mass of 502 tonnes. Subsequently, an aero-structural design and optimization were performed to reduce the blade mass/cost with more than 25% mass reduction and 30% cost reduction by determining optimal blade chord and airfoil thickness for best aero-structural performance.

Yao, Shulong↗

CFD Data on a Vertical Axis Wave Turbine

In this study January to July, 2023, different variations of the original geometry of a vertical-axis wave turbine (VAWT) were generated and evaluated for hydrodynamic power efficiency using computational fluid dynamics (CFD). The key geometrical parameters considered in this parametric study included the chord length of the rotor blades and the horizontal semi-axis length. The immersion depth of the rotor was also examined as a key deployment parameter for the wave turbine. The CFD simulation results revealed that a medium chord length of the blade (i.e., the same as that of the baseline design) and a shorter horizontal semi-axis for the guide curve of the blade than that of the baseline design resulted in higher hydrodynamic power to extract. With the most efficient turbine rotor geometry identified in this study, a deployment depth that could assure full submergence of the rotor in waves but as close to the free surface as possible led to a higher hydrodynamic power. These findings revealed a pathway for the improvement of the wave turbine energy efficiency.

16 TIDAL AND WAVE POWER↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultra High Speed High Temperature Motor

The goal of this project was to develop a high-speed, high-temperature motor capable of operating at 650 ºC, 60,000 rpm, and 125 kW with 50 kW/L. Key objectives to achieve this goal were to develop a suitable high-temperature wire, designing and fabricating rotor and stator subassemblies, designing an inverter assembly, and thermomechanical validation of the fully assembled motor. Four candidates for high-temperature wire were evaluated using test solenoid structures and finite element analysis modeling. The best candidate was a silicone-enameled copper wire suitable for continuous operation at 593 ºC. The rotor for the motor was designed to use a composite material comprised of 74% iron and 26% mullite by volume. This material would be suitable for 3D printing of the rotor. At the end of the project a vacuum mixer was under construction to produce the bubble-free material needed to achieve the highest strength composite after 3D printing. Rotor testing at 60,000 rpm would have commenced immediately following the additive manufacturing process. The project abruptly ended when key personnel left the project without notice.

42 ENGINEERING↗

Modeling and Analysis of Wind Turbine Wake Vortex Evolution Due to Time-Constant Spatial Variations in Atmospheric Flow

Modern utility-scale wind turbines are evolving toward larger, lighter, and more flexible designs to meet the growing demand for renewable energy while minimizing logistical costs. However, these advancements in lightweight design result in heightened aeroelastic sensitivity, leading to complex interactions which affect the rotor’s capacity to withstand aerodynamic loading and the cascading effects that manifest in the wake’s vortex-structure evolution under variable atmospheric conditions. In this paper, we analyze the influence of stream-wise fluctuating atmospheric flow conditions on wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex–wake interactions for a range of conditions with spatially variant atmospheric flow. CODEF solutions for turbine operation in wind conditions featuring only one parameter fluctuation are compared to wind conditions with several wind parameter variations in combination. By isolating individual inflow variations and comparing them to multi-parameter scenarios, we determine the contributions of each atmospheric factor to rotor dynamics, wake evolution, and downstream wind farm interactions. The purpose of this paper is to analyze the effects of spatial variations in atmospheric flow on the topological evolution of wind turbine vortex wakes, which constitutes a gap in the current understanding of wind turbine wake dynamics. The insights gained from this study are particularly valuable for the development of wind farm control strategies aimed at mitigating the adverse effects of wake interactions, enhancing energy capture, and improving the overall stability of wind farm operations. With these insights, we aim to contribute to the development of modeling and simulation tools to optimize utility-scale wind power plants operating in diverse atmospheric environments.

Farrell, Alayna (ORCID:000000023555720X)↗

How wind speed shear and directional veer affect the power production of a megawatt-scale operational wind turbine

Most megawatt-scale wind turbines align themselves into the wind as defined by the wind speed at or near the center of the rotor (hub height). However, both wind speed and wind direction can change with height across the area swept by the turbine blades. A turbine aligned to hub-height winds might experience suboptimal or superoptimal power production, depending on the changes in the vertical profile of wind, also known as shear. Using observed winds and power production over 6 months at a site in the high plains of North America, we quantify the sensitivity of a wind turbine's power production to wind speed shear and directional veer as well as atmospheric stability. We measure shear using metrics such as α (the log-law wind shear exponent), β bulk (a measure of bulk rotor-disk-layer veer), β total (a measure of total rotor-disk-layer veer), and rotor-equivalent wind speed (REWS; a measure of actual momentum encountered by the turbine by accounting for shear). We also consider the REWS with the inclusion of directional veer, REWS θ , although statistically significant differences in power production do not occur between REWS and REWS θ at our site. When REWS differs from the hub-height wind speed (as measured by either the lidar or a transfer function-corrected nacelle anemometer), the turbine power generation also differs from the mean power curve in a statistically significant way. This change in power can be more than 70 kW or up to 5 % of the rated power for a single 1.5 MW utility-scale turbine. Over a theoretical 100-turbine wind farm, these changes could lead to instantaneous power prediction gains or losses equivalent to the addition or loss of multiple utility-scale turbines. At this site, REWS is the most useful metric for segregating the turbine's power curve into high and low cases of power production when compared to the other shear or stability metrics. Therefore, REWS enables improved forecasts of power production.

17 WIND ENERGY↗

The importance of round-robin validation when assessing machine-learning-based vertical extrapolation of wind speeds

The extrapolation of wind speeds measured at a meteorological mast to wind turbine rotor heights is a key component in a bankable wind farm energy assessment and a significant source of uncertainty. Industry-standard methods for extrapolation include the power-law and logarithmic profiles. The emergence of machine-learning applications in wind energy has led to several studies demonstrating substantial improvements in vertical extrapolation accuracy in machine-learning methods over these conventional power-law and logarithmic profile methods. In all cases, these studies assess relative model performance at a measurement site where, critically, the machine-learning algorithm requires knowledge of the rotor-height wind speeds in order to train the model. This prior knowledge provides fundamental advantages to the site-specific machine-learning model over the power-law and log profiles, which, by contrast, are not highly tuned to rotor-height measurements but rather can generalize to any site. Furthermore, there is no practical benefit in applying a machine-learning model at a site where winds at the heights relevant for wind energy production are known; rather, its performance at nearby locations (i.e., across a wind farm site) without rotor-height measurements is of most practical interest. To more fairly and practically compare machine-learning-based extrapolation to standard approaches, we implemented a round-robin extrapolation model comparison, in which a random-forest machine-learning model is trained and evaluated at different sites and then compared against the power-law and logarithmic profiles. We consider 20 months of lidar and sonic anemometer data collected at four sites between 50 and 100 km apart in the central United States. We find that the random forest outperforms the standard extrapolation approaches, especially when incorporating surface measurements as inputs to include the influence of atmospheric stability. When compared at a single site (the traditional comparison approach), the machine-learning improvement in mean absolute error was 28 % and 23 % over the power-law and logarithmic profiles, respectively. Using the round-robin approach proposed here, this improvement drops to 20 % and 14 %, respectively. These latter values better represent practical model performance, and we conclude that round-robin validation should be the standard for machine-learning-based wind speed extrapolation methods.

17 WIND ENERGY↗

Ball transfer mechanism with polycrystalline diamond bearing support

A ball transfer mechanism for a harmonic drive and linear piston motor is disclosed. The ball transfer mechanism includes a spherical ball and a cylindrical seat portion. The seat portion defines a hemispherical shaped recess with a contour for receiving the ball. The ball transfer mechanism is in an exterior wall of a housing for converting rotary motion to linear motion, driving a linear piston motor. The harmonic drive drives a rotor of the linear piston motor. The harmonic drive includes a hollow cylindrical coupler portion engaging a rotor portion for transferring torque to the rotor portion. Transfer mechanisms disposed along a housing wall of the linear piston motor engage the coupler portion. The coupler portion includes harmonic cam grooves for receiving spherical balls in the ball transfer mechanism that drives rotational motion in the rotor in response to axially linear movement of the piston assembly.

Raymond, David W.↗

Electromagnetic propulsion system

An electromagnetic propulsion system comprises a plurality of stator coils wound about a first axis, a plurality of support structures, a coupler that surrounds a portion of the stator coils, and a plurality of rotor coils wound about an axis that is parallel to the first axis. The stator coils are configured to receive electric current to induce a first magnetic field. The support structures support the stator coils. The coupler includes a notch oriented so that one of the support structures can pass through the notch when the coupler moves along the stator coils. The rotor coils are attached to the coupler and are configured to receive electric current to induce a magnetic field that interacts with the first magnetic field so that a magnetic force is applied to the rotor coils, thereby propelling the coupler and the rotor coils along the stator coils.

Hartman, Seth↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗