Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

RBS, XRR and optical reflectivity measurements of Ti-TiO{sub 2} thin films deposited by magnetron sputtering

Highlights: Black-Right-Pointing-Pointer The single-, bi- and tri-layered films of Ti-TiO{sub 2} deposited onto Si(1 1 1) substrates. Black-Right-Pointing-Pointer Three methods RBS, XRR, optical reflectometer were used. Black-Right-Pointing-Pointer The real thickness of each layer was smaller than 50 nm. Black-Right-Pointing-Pointer Ti and TiO{sub 2} film-densities were slightly lower than the corresponding bulk values. -- Abstract: Single-, bi- and tri-layered films of Ti-TiO{sub 2} system were deposited by d.c. pulsed magnetron sputtering from metallic Ti target in an inert Ar or reactive Ar + O{sub 2} atmosphere. The nominal thickness of each layer was 50 nm. The chemical composition and its depth profile were determined by Rutherford backscattering spectroscopy (RBS). Crystallographic structure was analysed by means of X-ray diffraction (XRD) at glancing incidence. X-ray reflectometry (XRR) was used as a complementary method for the film thickness and density evaluation. Modelling of the optical reflectivity spectra of Ti-TiO{sub 2} thin films deposited onto Si(1 1 1) substrates provided an independent estimate of the layer thickness. The combined analysis of RBS, XRR and reflectivity spectra indicated the real thickness of each layer less than 50 nm with TiO{sub 2} film density slightly lower than the corresponding bulk value. Scanning Electron Microscopy (SEM) cross-sectional images revealed the columnar growth of TiO{sub 2} layers. Thickness estimated directly from SEM studies was found to be in a good agreement with the results of RBS, XRR and reflectivity spectra.

36 MATERIALS SCIENCE↗

Quasi-elastic measurement using neutron spin flippers.

A method for low-resolution quasi-elastic measurements using commonly available components on a polarized neutron beam reflectometer is demonstrated. By amplitude modulation of the current in a neutron spin flipper placed between the neutron beam polarizer and polarization analyzer, the intensity of the neutron beam illuminating a sample is similarly modulated (or chopped). We show that the intensity contrast between subsequent chopped pulses is dramatically reduced by a sample that changes neutron velocity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Optical properties enhancement of thermal energy media for consistently high solar absorptivity

This study aimed to evaluate the optical properties of particles intended for use as thermal energy absorbers in generation 3 concentrated solar power systems. Their characterization involved UV–Vis NIR measurements with an integrating sphere for solar absorptivity, while a reflectometer was employed to measure thermal emittance. By combining absorptivity and emittance data, the solar absorption efficiency was calculated. Laser flash analysis, differential scanning calorimetry, and thermogravimetric analysis were utilized to determine thermal conductivity and specific heat. The solar absorptivity of the particles was initially measured at 0.90. After exposure to air at 1000 °C, it decreased to 0.73. However, following a reduction process, the particle recovered absorptivity of 0.90. The thermal aging and recovery were repeated multiple times, consistently achieving an absorptivity of 0.90. The thermal conductivity of the particles ranged from 0.50 to 0.88 W/(m-K). Solar absorptivity was found to be influenced by the types of iron oxide present in the particles. Particles with a predominance of hematite exhibited decreased solar absorptivity, while those containing magnetite, wüstite, and iron showed increased absorptivity. The estimated cost of the developed particles was more than ten times lower than that of current products. Given that component costs significantly impact the levelized cost of electricity (LCOE), this price reduction corresponded to an 8 % decrease in LCOE compared to other products. The low-cost thermal energy media show great promise for contributing to a reduced LCOE in the third generation of concentrating solar power systems.

14 SOLAR ENERGY↗

Phase and microphase separation of polymer thin films dewetted from silicon - a spin-echo resolved grazing incidence neutron scattering study.

An understanding of the structure of ultrathin polymer films on solid substrates has scientific importance in applications as well as in fundamental studies of polymer diffusion or adsorption. We present studies of the organization of dewetted droplets of polymers on a silicon surface using a new neutron scattering technique, spin-echo resolved grazing incidence scattering (SERGIS), that has the potential to address at the same time the droplet-droplet correlations and the chemical configuration inside each droplet. For the seminal experiments, the polarized neutron reflectometer EVA at the Institut Laue-Langevin, Grenoble, France, was equipped with a spin-echo setup, and measurements were taken on surface structures previously characterized by different techniques. The dewetted polymers used in our studies were pure polystyrene, a mixture of polystyrene and polyparamethylstyrene, and a diblock copolymer of the two homopolymers. Even with a provisional setup SERGIS, we were able to determine the correlation between the droplets, providing results in excellent agreement with those obtained by atomic force microscopy and grazing incidence small-angle X-ray and neutron scattering. In addition, it was confirmed that the correlation function for diblock copolymer droplets is more complex than for polymer mixtures, exhibiting partial ordering of the copolymer within each droplet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-speed x-ray reflectometory in multiwavelength-dispersive mode

The potential of a high speed x-ray reflectometer for time-resolved studies on the subsecond to millisecond timescales is demonstrated by recording x-ray reflection curves from a small area (1 mmx10 mm) of a 14.3 nm thick gold film on a silicon substrate with data collection times of 0.05-1 s. A horizontally convergent x-ray beam having a one-to-one correlation between ray direction and energy is produced by a curved crystal polychromator, and the beam is incident on and vertically reflected by a specimen placed at the focus. The x-ray reflectivity is measured as a function of the x-ray energy downstream of the focus using a one dimensional detector with no need for angle scan of the specimen and detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current Status and Future Works of Neutron Scattering Laboratory at BATAN in Serpong

Current status of neutron beam instruments using neutrons produced by the Multi Purpose Research Reactor--30MWth (MPR 30, RSG GA Siwabessy) located in Serpong is presented. Description of the reactor as the neutron source is mentioned briefly. There are six neutron beam tubes coming from the beryllium reflector surrounding half of the reactor core providing neutrons in the experimental hall of the reactor (XHR). Four of them are dedicated to R and D in materials science using neutron scattering techniques. Neutron Radiography Facility (NRF), Triple Axis Spectrometer (TAS) and Residual Stress Measurement (RSM) Diffractometer are installed respectively at beam tubes S2, S4 and S6. The largest neutron beam tube (S5) is exploited to accommodate two neutron guide tubes that transfer the neutrons to a neighbouring building called neutron guide hall (NGH). There are three other neutron beam instruments installed in this building, namely Small Angle Neutron Scattering (SANS) Spectrometer (SMARTer), High Resolution SANS (HRSANS) Spectrometer and High Resolution Powder Diffractometer (HRPD). In the XHR, a Four Circle and Texture Diffractometer (FCD/TD) is attached to one of the neutron guide tubes. These seven instruments were installed to utilize the neutrons for materials science research, and recently the RSM diffractometer has shown its capabilities in identifying different amount of stress left due to different treatments of welding in fuel cladding, while the SANS spectrometer is now gaining capabilities in identifying different sizes and shapes of macromolecules in polymers as well as investigations of magnetic samples. In the mean time, non-destructive tests using the NRF is gathering more confidence from some latest real time measurements eventhough there are still some shortcomings in the components and their alignments. Future works including improvement of each facility and its components, even replacement of some parts are necessary and have to be carried out carefully. A plan for developing a neutron reflectometer at one of the neutron guide in the Neutron Guide Hall is also part of the near future activities.

36 MATERIALS SCIENCE↗

NOVEL CRYOGENIC ENGINEERING SOLUTIONS FOR THE NEW AUSTRALIAN RESEARCH REACTOR OPAL

In August 2006 the new 20MW low enriched uranium research reactor OPAL went critical. The reactor has 3 main functions, radio pharmaceutical production, silicon irradiation and as a neutron source. Commissioning on 7 neutron scattering instruments began in December 2006. Three of these instruments (Small Angle Neutron Scattering, Reflectometer and Time-of-flight Spectrometer) utilize cold neutrons.The OPAL Cold Neutron Source, located inside the reactor, is a 20L liquid deuterium moderated source operating at 20K, 330kPa with a nominal refrigeration capacity of 5 kW and a peak flux at 4.2meV (equivalent to a wavelength of 0.4nm). The Thermosiphon and Moderator Chamber are cooled by helium gas delivered at 19.8K using the Brayton cycle. The helium is compressed by two 250kW compressors (one with a variable frequency drive to lower power consumption).A 5 Tesla BSCCO (2223) horizontal field HTS magnet will be delivered in the 2{sup nd} half of 2007 for use on all the cold neutron instruments. The magnet is cooled by a pulse tube cryocooler operating at 20K. The magnet design allows for the neutron beam to pass both axially and transverse to the field. Samples will be mounted in a 4K to 800K Gifford-McMahon (GM) cryofurnace, with the ability to apply a variable electric field in-situ. The magnet is mounted onto a tilt stage. The sample can thus be studied under a wide variety of conditions.A cryogen free 7.4 Tesla Nb-Ti vertical field LTS magnet, commissioned in 2005 will be used on neutron diffraction experiments. It is cooled by a standard GM cryocooler operating at 4.2K. The sample is mounted in a 2{sup nd} GM cryocooler (4K-300K) and a variable electric field can be applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of the absolute phase in frequency modulated continuous wave plasma reflectometry

In frequency modulated continuous wave reflectometry, used for density profile measurement in fusion plasmas, it is usual to measure the beat frequency between the launched wave and the reflected wave, and from this to calculate the position of the reflecting layer in the plasma. The absolute phase of the beat signal is usually neglected. The reason is that the phase shift between sweeps is usually comparable with or more than 2{pi}, leading to an ambiguity that is impossible to resolve. However, recent observations on the MAST tokamak have shown that, under quiet plasma conditions (this term has to be defined), the phase shift between sweeps is small compared with 2{pi} and the phase ambiguity can be readily resolved. The reflectometer signal is then being analyzed as an interferometer signal would normally be, and there is a substantial improvement in spatial resolution. The method is illustrated by application to small edge localized mode precursor and allows what is believed to be the first quantitative measurement of the displacement of the plasma boundary by such a precursor mode. The errors in both the absolute phase measurement and the more conventional frequency measurement are also estimated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of reflectometry power flow for magnetic field pitch angle measurements in tokamak plasmas (invited)

Reflectometry has successfully demonstrated measurements of many important parameters in high temperature tokamak fusion plasmas. However, implementing such capabilities in a high-field, large plasma, such as ITER, will be a significant challenge. In ITER, the ratio of plasma size (meters) to the required reflectometry source wavelength (millimeters) is significantly larger than in existing fusion experiments. This suggests that the flow of the launched reflectometer millimeter-wave power can be realistically analyzed using three-dimensional ray tracing techniques. The analytical and numerical studies presented will highlight the fact that the group velocity (or power flow) of the launched microwaves is dependent on the direction of wave propagation relative to the internal magnetic field. It is shown that this dependence strongly modifies power flow near the cutoff layer in a manner that embeds the local magnetic field direction in the 'footprint' of the power returned toward the launch antenna. It will be shown that this can potentially be utilized to locally determine the magnetic field pitch angle at the cutoff location. The resultant beam drift and distortion due to magnetic field and relativistic effects also have significant consequences on the design of reflectometry systems for large, high-field fusion experiments. These effects are discussed in the context of the upcoming ITER burning plasma experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First density profile measurements using frequency modulation of the continuous wave reflectometry on JET

We present the main design options and implementation of an X-mode reflectometer developed and successfully installed at JET using an innovative approach. It aims to prove the viability of measuring density profiles with high spatial and temporal resolution using broadband reflectometry operating in long and complex transmission lines. It probes the plasma with magnetic fields between 2.4 and 3.0 T using the V band [{approx}(0-1.4)x10{sup 19} m{sup -3}]. The first experimental results show the high sensitivity of the diagnostic when measuring changes in the plasma density profile occurring ITER relevant regimes, such as ELMy H-modes. The successful demonstration of this concept motivated the upgrade of the JET frequency modulation of the continuous wave (FMCW) reflectometry diagnostic, to probe both the edge and core. This new system is essential to prove the viability of using the FMCW reflectometry technique to probe the plasma in next step devices, such as ITER, since they share the same waveguide complexity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Key Technologies for Ultra High Dose CMOS Applications

The trend towards shrinking advanced microelectronic Logic and DRAM devices will require ultra high dose implantation. One ultra high dose application in DRAM, being rapidly adopted in production is Dual Poly Gate (DPG). Three main challenges existed for the adoption of this high dose dual poly gate (DPG) doping applications: monitoring of high dose implantation, photoresist stripping and maintaining high throughput. In this paper we present how these challenges have been addressed. VSEA's plasma doping (PLAD) tool offers several unique advantages for DPG applications. When compared to conventional or molecular beam line implanters or other immersion techniques, PLAD delivers 3 to 7 times higher throughput (compared to traditional ion implanter) without dopant penetration through the thin doped polysilicon layer into the gate oxide. It also improves P{sup +} poly silicon DPG device properties at superior throughput. In this work we demonstrate how hot spray photoresist strip processing eliminates the need for multiple-tools required for wet+ash+wet process. In addition to PLAD's patented in-situ dose control metrology we also demonstrate an ex-situ high dose implantation metrology using spectroscopic ellipsometer (SE) and spectroscopic reflectometer (SR). The technique shows good correlation (R{sup 2}{approx}0.99) between implant dose and damaged layer thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling fast-ion transport during toroidal Alfven eigenmode avalanches in National Spherical Torus Experiment

Experiments on the National Spherical Torus Experiment [M. Ono et al., Nucl. Fusion 40, 557 (2000)] found strong bursts of toroidal Alfven eigenmode (TAE) activity correlated with abrupt drops in the neutron rate. A fairly complete data set offers the opportunity to benchmark the NOVA[C. Z. Cheng, Phys. Rep. 211, 1 (1992)] and ORBIT[R. B. White and M. S. Chance, Phys. Fluids 27, 2455 (1984)] codes in the low aspect ratio tokamak (ST) geometry. The internal structure of TAE was modeled with NOVA and good agreement is found with measurements made with an array of five fixed-frequency reflectometers. The fast-ion transport resulting from these bursts of multiple TAE was then modeled with the ORBIT code. The simulations are reasonably consistent with the observed drop in neutron rate, however, further refinements in both the simulation of the TAE structure and in the modeling of the fast-ion transport are needed. Benchmarking stability codes against present experiments is an important step in developing the predictive capability needed to plan future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the cross-phase angle between density and electron temperature fluctuations and comparison with gyrokinetic simulations

This paper presents new measurements of the cross-phase angle, alpha{sub n{sub eT{sub e}}}, between long-wavelength (k{sub t}hetarho{sub s}<0.5) density, n-tilde{sub e}, and electron temperature, T-tilde{sub e}, fluctuations in the core of DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] tokamak plasmas. The coherency and cross-phase angle between n-tilde{sub e} and T-tilde{sub e} are measured using coupled reflectometer and correlation electron cyclotron emission diagnostics that view the same plasma volume. In addition to the experimental results, two sets of local, nonlinear gyrokinetic turbulence simulations that are performed with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] are described. One set, called the pre-experiment simulations, was performed prior to the experiment in order to predict a change in alpha{sub n{sub eT{sub e}}} given experimentally realizable increases in the electron temperature, T{sub e}. In the experiment the cross-phase angle was measured at three radial locations (rho=0.55, 0.65, and 0.75) in both a 'Base' case and a 'High T{sub e}' case. The measured cross-phase angle is in good qualitative agreement with the pre-experiment simulations, which predicted that n-tilde{sub e} and T-tilde{sub e} would be out of phase. The pre-experiment simulations also predicted a decrease in cross-phase angle as T{sub e} is increased. Experimentally, this trend is observed at the inner two radial locations only. The second set of simulations, the postexperiment simulations, is carried out using local parameters taken from measured experimental profiles as input to GYRO. These postexperiment simulation results are in good quantitative agreement with the measured cross-phase angle, despite disagreements with transport fluxes. Directions for future modeling and experimental work are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics for first plasma and development plan on KSTAR

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the role of spectral resolution in velocity shear layer measurements by Doppler reflectometry

The signal quality of a Doppler reflectometer depends strongly on its spectral resolution, which is influenced by the microwave beam properties and the radius of curvature of the cutoff layer in the plasma. If measured close to a strong perpendicular velocity shear layer, the spectrum of the backscattered signal is influenced by different velocities. This can give rise to two Doppler shifted peaks in the spectrum as observed in TJ-II H-mode plasmas. It is shown by two-dimensional full wave simulations that the two peaks are separable provided the spectral resolution of the system is sufficient. However, if the spectral resolution is poor, the two peaks blend into one and yield an intermediate and incorrect velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗