Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REAGENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Discourse for slide presentation: An overview of chemical detection systems

A brief overview of some of the analytical techniques currently used in monitoring and analyzing permanent gases and selected volatile organic compound in air are presented. Some of the analytical considerations in developing a specific method are discussed. Four broad groups of hardware are discussed: compound class specific personal monitors, gas chromatographic systems, infrared spectroscopic systems, and mass spectrometric residual gas analyzer systems. Three types of detectors are also discussed: catalytic sensor based systems, photoionization detectors, and wet or dry chemical reagent systems. Under gas chromatograph based systems five detector systems used in combination with a GC are covered: thermal conductivity detectors, photoionization detectors, Fourier transform infrared spectrophotometric systems, quadrapole mass spectrometric systems, and a relatively recent development, a surface acoustic wave vapor detector.

Peters, Randy Alan↗

Oxygen production by pyrolysis of lunar regolith

Oxygen was identified as the most important product of initial lunar materials processing efforts. A source of oxygen on the Moon provides an alternative to the costly transport of propellant to the Moon or to low earth orbit. Pyrolysis, or vapor-phase reduction, involves heating a feedstock to temperatures sufficient to decompose the constituent metal oxides and release oxygen. The process relies on the vaporization of metal oxides in the form of reduced suboxides or atomic species. The reduced species must then be condensed without re-oxidizing, yielding oxygen in the gas phase. The feasibility of obtaining oxygen from common lunar minerals was demonstrated using solar furnace experiments. These results are discussed together with chemical equilibrium models which were extended to include the multicomponent oxides used in experiments. For the first time, both experiments and theoretical models dealt with the complex oxides that make up potential lunar feedstocks. Two major conclusions are drawn from this preliminary work. First, unbeneficiated regolith is a suitable feedstock for pyrolysis. Second, the process can operate at moderate temperatures, circa 2000 K, which could be supplied by direct solar or electrical energy. In addition to these advantages in choice of feedstock and energy source, the pyrolysis process requires no chemicals or reagents, making it an attractive process for lunar oxygen production.

Senior, Constance L.↗

The microassay on a card: A rugged, portable immunoassay

The Microassay on a Card (MAC) is a portable, hand-held, non-instrumental immunoassay that can test for the presence of a wide variety of substances in the environment. The MAC is a simple device to use. A drop of test solution is placed on one side of the card and within five minutes a color is developed on the other side in proportion to the amount of substance in the test solution, with sensitivity approaching 10 ng/ml. The MAC is self-contained and self-timed; no reagents or timing is necessary. The MAC may be configured with multiple wells to provide simultaneous testing for multiple species. As envisioned, the MAC will be employed first as an on-site screen for drugs of abuse in urine or saliva. If the MAC can be used as a screen of saliva for drugs of abuse, it could be applied to driving while intoxicated, use of drugs on the job, or testing of the identity of seized materials. With appropriate modifications, the MAC also could be used to test for environmental toxins or pollutants.

Kidwell, David↗

Stability and reactivity of dimethylethoxysilane

Dimethylethoxysilane (DMES) is currently used to treat the High-temperature Reusable Surface Insulation (HRSI) shuttle tiles in order to provide a hydrophobic surface on the silica. DMES is a volatile, reactive silane that incorporates two reactive sites, the ethoxy group and the silica-hydride group. The work reported in this paper focused on the reactivity of these two groups with silica, water, quantitative reagents, and within DMES itself.

Johnson, Richard E.↗

Spectral identification of chemisorbed CO2 and application to Mars analog materials

The goal of this work is to identify the spectral signature of chemisorbed CO2, to test the efficacy of carbonate formation on Mars-analog materials via CO2 chemisorption, and to identify the surface-chemical characteristics of good chemisorbents, with the intent of assessing the possible geochemical importance of CO2 chemisorption as a quasipermanent CO2 sink in the Martian environment. Our approach is to search for infrared spectral bands that result from chemisorption of CO2 molecules onto chemical reagents and Mars-analog materials, and to identify the salient differences in adsorbents that favor strong, permanent CO2 chemisorption. The total amount of CO2 in the early Martian atmosphere, and consequent surface temperatures, are unknown. A CO2 greenhouse may not have been an adequate mechanism under any circumstances; however, it if were, then most of that CO2 must still be in the near-surface environment; no escape mechanism that could remove it after the decline of channeling has been identified. The only plausible reservoir is carbonate, and there are various remote sensing techniques that can be used to search for it. We are investigating CO2 chemisorption as a permanent CO2 sink, and to aid in interpretation of remotely sensed IR spectra of Mars. A common effect reported in CO2 adsorption studies is the formation of a layer of carbonate or bicarbonate anions on adsorbents that have OH- groups available on their surfaces. Inorganic hydroxyls occur on phyllosilicates, amorphous silicates, metal oxides and hydroxides; it is the most abundant and reactive surface functional group on the surfaces of terrestrial silicates. The process responsible for the reaction is chemisorption. Chemisorption is distinguished from physical adsorption in that there is a transfer of electrons between species, and the formation of a chemical bond. The heat of chemisorption is typically of the same order as heats of chemical reaction (i.e., a few hundred to a few thousand kJ/mole), as opposed to heats of physical adsorption (a few kJ per mole). Chemisorption is an activated process that is promoted by an increase in temperature - quite the opposite of physical adsorption. Chemisorption is not reversible in the sense that physical adsorption is.

Zent, A. P.↗

Total Organic Carbon Analyzer

The development and testing of a breadboard version of a highly sensitive total-organic-carbon (TOC) analyzer are reported. Attention is given to the system components including the CO2 sensor, oxidation reactor, acidification module, and the sample-inlet system. Research is reported for an experimental reagentless oxidation reactor, and good results are reported for linearity, sensitivity, and selectivity in the CO2 sensor. The TOC analyzer is developed with gravity-independent components and is designed for minimal additions of chemical reagents. The reagentless oxidation reactor is based on electrolysis and UV photolysis and is shown to be potentially useful. The stability of the breadboard instrument is shown to be good on a day-to-day basis, and the analyzer is capable of 5 sample analyses per day for a period of about 80 days. The instrument can provide accurate TOC and TIC measurements over a concentration range of 20 ppb to 50 ppm C.

Godec, Richard G.↗

Ethylene-Vapor Optrodes

Porous optical fibers include sensing regions filled with reagents. Optical-fiber chemical sensors (optrodes) developed to measure concentrations of ethylene in air in enclosed artificial plant-growth environments. Such measurements needed because ethylene acts as plant-growth hormone affecting growth at concentrations less than or equal to 20 parts per billion. Optrodes small, but exhibit sensitivities comparable to those of larger instruments. Operated safely in potentially explosive atmospheres and neither cause, nor susceptible to, electrical interference at suboptical frequencies.

Tabacco, Mary Beth↗

Apparatus Would Stain Microscope Slides

Proposed apparatus meters specific amounts of fluid out of containers at specific times to stain microscope slides. Intended specifically for semiautomated staining of microbiological and hematological samples in microgravity, leakproof apparatus used in other environments in which technicians have little time to allocate to staining procedures and/or exposure to toxic staining agents or to micro-organisms to be stained hazardous. Apparatus adapted to perform almost any staining procedure and accommodates multiple staining reagents, useful for small or remote clinical laboratories.

Breeding, James D.↗

Lunar mining of oxygen using fluorine

An important aspect of lunar mining will be the extraction of volatiles, particularly oxygen, from lunar rocks. Thermodynamic data show that oxygen could readily be recovered by fluorination of abundant lunar anorthite, CaAl2Si2O8. Fluorine is the most reactive element, and the only reagent able to extract 100 percent of the oxygen from any mineral, yet it can safely be stored or reacted in nickel or iron containers. The general fluorination reaction, mineral + 2F2 = mixed fluorides = O2, has been used for more than 30 years at a laboratory scale by stable-isotope geochemists. For anorthite, metallic Al and Si may be recovered from the mixed fluorides by Na-reduction, and CaO via exchange with Na2O; the resulting NaF may be recycled into F2 and Na by electrolysis, using lanthanide-doped CaF2 as the inert anode.

Burt, Donald M.↗

Economic Geology of the Moon: Some Considerations

Supporting any but the smallest lunar facility will require indigenous resources due to the extremely high cost of bringing material from Earth. The Moon has also attracted interest as a resource base to help support near-Earth space activities, because of the potential lower cost once the necessary infrastructure has been amortized. Obviously, initial lunar products will be high-volume, bulk commodities, as they are the only ones for which the economics of lunar production are conceivably attractive. Certain rarer elements, such as the halogens, C, and H, would also be extremely useful (for propellant, life support, and/or reagents), and indeed local sources of such elements would vastly improve the economics of lunar resource extraction. The economic geology of the Moon is discussed.

Gillett, Stephen L.↗

In situ propellant production: Alternatives for Mars exploration

Current planning for the Space Exploration Initiative (SEI) recognizes the need for extraterrestrial resources to sustain long-term human presence and to attain some degree of self-sufficiency. As a practical matter, reducing the need to carry large supplies of propellant from Earth will make space exploration more economical. For nearly every round trip planned with conventional propulsion, the actual payload is only a small fraction - perhaps 10-15 percent - of the mass launched from Earth. The objective of this study was to analyze the potential application for SEI missions of propellants made exclusively from lunar or martian resources. Using such propellants could minimize or eliminate the cost of carrying propellant for surface excursion vehicles and return transfers through two high-energy maneuvers: Earth launch and trans-Mars injection. Certain chemical mono- and bipropellants are candidates for this approach; they could be recovered entirely from in situ resources on the Moon and Mars, without requiring a continuing Earth-based resupply of propellant constituents (e.g., fuel to mix with a locally obtained oxidizer) and, perhaps, with minimal need to resupply consumables (e.g., reagents or catalyst for process reactions). A complete assessment of the performance potential of these propellants must include the requirements for installation, operations, maintenance, and resupply of the chemical processing facility.

Stancati, Michael L.↗

Reclamation with Recovery of Radionuclides and Toxic Metals from Contaminated Materials, Soils, and Wastes

A process has been developed at Brookhaven National Laboratory (BNL) for the removal of metals and radionuclides from contaminated materials, soils, and waste sites. In this process, citric acid, a naturally occurring organic complexing agent, is used to extract metals such as Ba, Cd, Cr, Ni, Zn, and radionuclides Co, Sr, Th, and U from solid wastes by formation of water soluble, metal-citrate complexes. Citric acid forms different types of complexes with the transition metals and actinides, and may involve formation of a bidentate, tridentate, binuclear, or polynuclear complex species. The extract containing radionuclide/metal complex is then subjected to microbiological degradation followed by photochemical degradation under aerobic conditions. Several metal citrate complexes are biodegraded, and the metals are recovered in a concentrated form with the bacterial biomass. Uranium forms binuclear complex with citric acid and is not biodegraded. The supernatant containing uranium citrate complex is separated and upon exposure to light, undergoes rapid degradation resulting in the formation of an insoluble, stable polymeric form of uranium. Uranium is recovered as a precipitate (polyuranate) in a concentrated form for recycling or for appropriate disposal. This treatment process, unlike others which use caustic reagents, does not create additional hazardous wastes for disposal and causes little damage to soil which can then be returned to normal use.

Francis, A. J.↗

Rapid chemical test for the identification of chromium-molybdenum steel

This note describes a simple, rapid, qualitative test which can be applied to solutions of drilling or chips for the identification of chromium-molybdenum steel. The test is based on the orange-red compound which is formed when thiocyanate and inequivalent molybdenum react. This test is much more reliable than the potassium ethylxanthate test which has been recommended for a like purpose. A list of the apparatus and reagents which are required, and a description of the procedure follows.

Redmond, John C↗

In situ detection of tropospheric OH, HO2, NO2, and NO by laser-induced fluorescence in detection chambers at reduced pressures

For detection of OH and HO2, we have met or exceeded most of the goals of the proposal for this grant. We have succeeded in building a prototype instrument for the detection of OH and HO2 that has a detection sensitivity of about 2 x 10 exp 4 (OH molecules/cc)/(ct/s), about five times greater than proposed. The current minimum detectable OH of 1.4 x 10 exp 5 OH molecules/cc (S/N=2; 30 second integration) is less than half that proposed, and will be much lower once scattered light levels are reduced. The instrument displays other important properties. First, interfering signals from other gases and OH losses on the inlet appear to be small under laboratory and field conditions. Second, three different calibration methods, two external to the inlet, give similar results, to within 30 percent. Third, the chemical conversion efficiency of HO2 to OH by addition of reagent NO is better than 90 percent. All of these factors give us great confidence that this technique works. The instrument has gone through several variations that have not affected its potential performance but have affected its use. We were able to undergo the first field trials away from State College in June 1992, when we were able to participate informally in the ROSE experiment in rural Alabama, a year ahead of the proposed schedule for field studies. Because this field experiment was our first and the data analysis was complicated by instrument instabilities, we have not yet released the observations. None-the-less, we have gained insight into instrument design. We have not yet completed all of the proposed work. The calibration systems need to be improved to reduce the 50 percent to 100 percent uncertainties to less than 30 percent. Interference signals from ambient gases and possible losses on the inlet under field conditions need to be quantified. Finally, the detection of NO2 and NO with laser induced fluorescence is only now being seriously pursued.

Brune, William H.↗

The evolution of energy-transducing systems. Studies with archaebacteria

N-ethylmaleimide (NEM) inhibits the ATPase of H. saccharovorum in a nucleotide protectable manner. The bulk of C-14 NEM is incorporated into subunit one. Cyanogen bromide cleavage of labeled subunit one indicated that NEM bound to a peptide of a Mr of about 8,900. Thus, Cys 262 (H. salinarium numbering) may be the NEM binding site. Cyanogen bromide fragments have been submitted for sequencing. To prove the presence of three Cys residues in subunit one, alkaline cleavage following treatment with NTCB was carried out. Thiol reagents such as p-chloro mercuri phenyl sulfonate also inhibited the ATPase. However, this inhibition was not nucleotide-protectable, suggesting a different location and role for the PCMS-sensitive Cys. The proteolipid which was extracted with chloroform/methanol from the membranes of H. saccharovorum cross-reacted with an antiserum against subunit c (the DCCD-binding protein) of Escherichia coli. Following labeling of membranes from H. saccharovorum with C-14 DCCD under conditions, which inhibited ATP synthesis, the isotope was incorporated into one protein of Mr of about 6,500. Thus, the proteolipid of H. saccharovorum and the DCCD-labeled peptide may be identical. If so, these results suggest that the proteolipid is a component of the membrane sector of an archaeal F-type ATP synthase.

Stan-Lotter, Helga↗

Fiber optic sensors for corrosion detection

The development of fiber optic sensors for the detection of a variety of material parameters has grown tremendously over the past several years. Additionally, the potential for analytical applications of fiber optic sensors have become more widely used. New pH sensors have also been developed using fiber optic techniques to detect fluorescence characteristics from immobilized fluorogenic reagent chemicals. The primary purpose of this research was to investigate the feasibility of using fiber optic sensors to detect the presence of Al(sup 3+) ions made in the process of environmental corrosion of aluminum materials. The Al(sup 3+) ions plus a variety of other type of metal ions can be detected using analytical techniques along with fiber optic sensors.

Smith, Alphonso C.↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

Method and apparatus for the collection, storage, and real time analysis of blood and other bodily fluids

The present invention provides a simple, portable, relatively inexpensive apparatus for accurately and efficiently collecting, separating, testing, and even storing between about 1-20 ml, preferably about 1-10 ml, of blood or other bodily fluid in situ. The apparatus includes a collection chamber bounded on its sides by an opening in a sheet of material, preferably clear plastic, abutting a filter card. The filter card is made of fibrous material, preferably less than about a millimeter thick, having an average pore size of less than about 3 microns. Preferably, the fibers are glass and the fibrous material has an average pore size of about 1 micron. The fibrous material is treated with a carbohydrate/protein mixture which contains between about 1-40 percent wt/vol carbohydrate and about 0.1-15 percent wt/vol nonspecific protein, preferably between about 10-20 percent carbohydrate and about 5-8 percent protein. A preferred carbohydrate/protein mixture comprises about 10 percent mannitol and about 6 percent albumin. The blood or other fluid moves through the filter card by capillary action aided by an absorbent matrix with a high Klemm factor which abuts the filter card. The absorbent matrix and/or filter card can be treated with a wide spectrum of test reagents. The speed, cleanliness, and efficiency of the separation process can be altered by: (a) changing the absolute concentration of the carbohydrate/protein mixture; (b) applying positive or negative pressure to one side of the filter; and/or (c) varying the relative density and pore size of the filter card and absorbent matrix.

Whitson, Peggy A.↗