Implementing machine learning methods on QICK hardware for qubit readout & control

Quantum readout and control is a fundamental aspect of quantum computing that requires accurate measurement of qubit states. Errors emerge in all stages, from initialization to readout, and identifying errors in post-processing necessitates resource-intensive statistical analysis. In our work, we use a lightweight fully-connected neural network (NN) to classify states of a transmon system with no prior processing. Our NN accelerator yields higher fidelities (92%) than the classical matched filter method (84%). By exploiting the natural parallelism of NNs and their placement near the source of data on field-programmable gate arrays (FPGAs), we can achieve ultra-low latency on the Quantum Instrumentation Control Kit (QICK). Integrating machine learning methods on QICK opens several pathways for efficient real-time processing of quantum circuits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Signal-to-Noise Ratio (SNR) for Quantum Readout Signals Using Adaptive Hardware Filters on FPGA

This research presents an innovative approach to improving the Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals, utilizing FPGA-based adaptive filtering on the control board. Our solution aims to bolster quantum computations' reliability by providing a more accurate and precise way to obtain our readout traces and achieve a higher discernability between excitation states in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable Skipper-CCD Analog Readout Electronics (SSCARE) for the Massive Multichannel OSCURA Experiment

We present a multiplexed analog readout electronics system for Skipper-CCDs based on the MIDNA ASIC. It allows for subelectron noise-level operation while maintaining a minimal number of acquisition channels. In addition, it requires low-disk storage and low-bandwidth data transfer with zero added multiplexing time during the simultaneous operation of thousands of channels. We describe the implementation of such a system in a new instrument composed by 16 sensors operated with a two-stage analog multiplexed readout scheme. The instrument is a part of the R&D effort of the OSCURA experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A self-certifying FPGA based pixel readout chip test system for CMS ETL upgrade

A flexible self-certifying pixel readout test system for testing the Endcap Timing Read-Out Chip (ETROC) has been developed for the CMS MIP Timing Detector (MTD), part of the upgrade for the HL-LHC. The system includes an FPGA-based (Xilinx KC705) test system that can take data from an emulator or up to four ETROC boards in telescope mode. A python based DAQ system simplifies configuration, calibration, and testing of the chips. The system provides an efficient & reliable solution for testing ETROC (ETROC2 since April 2023 with 16x16 pixels, full-size, full functionality prototype) and can be extended to other readout chips with similar architecture (AIDA integration is currently being explored).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Signal Signal-to -Noise Ratio (SNR) for Quantum Readout Signals Using Adaptive Hardware Filters on FPGA

This research presents an innovative approach to improving theSignalSignal-to -Noise Ratio (SNR) in superconducting quantumcomputing readout signals, utilizing adaptive filtering on thecontrol board. Our solution FPGA FPGA-based aims to bolsterquantum computations' reliability by providing a more accurateand precise way to obtain our readout traces and achieve ahigher discernability between excitation states in real real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Hard Smart-Pixel Detector ASIC ReadOut with Digital AI in 28nm

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout channels. With event rates as high as 40 MHz, these detectors will generate petabytes of data per second. To enable discovery within strict bandwidth and latency constraints, future trackers must be capable of fast, power efficient, and radiation hard data-reduction at the source. This effort is pursuing the co-design development of high-performance readout smart pixel ASICs for a future Phase III High Luminosity upgrade of the Large Hadron Collider. A 1.6mm2 ASIC prototype was designed by Fermilab in CMOS 28 nm bulk process and submitted for manufacturing in February 2024. It leverages the analog front-end pixel design of a previous prototype fabricated and tested in 2023, which achieved a simulated detection level of ~400e- with 30fF input capacitance. The ROIC consists of two matrices of 16×16 smart pixels, each 25×25 μm2 in size. Each smart pixel contains a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. There is digital space for the integration of our fully combinatorial AI that performs momentum classification at the bunch crossing rate. The total power consumption is ∼6μW per pixel, which corresponds to ~1mW/cm2. The ASIC incorporates programmable front-end charge injection circuitry to generate pixel cluster charges during characterization. The cluster profile will be generated to duplicate hit characteristics of various momentum (pT). We will present early results from chip testing.

Parpillon, Benjamin↗

2x2 Demonstrator High-Coverage Light Readout System in a Novel LArTPC

DUNE is a long-baseline Liquid Argon Time Projection Chamber (LArTPC) neutrino oscillation experiment. Its near detectors, located at Fermi National Laboratory, will constrain systematic errors on far detector measurements. The 2x2 Demonstrator, a novel proof of concept prototype for the ND LArTPC, has a modular TPC design that mitigates event pileup in a high-occupancy nearline beam environment, further aided by a native 3D pixelated charge readout and a 30% coverage, low profile light readout. This will be the first large-scale LArTPC to utilize pixels in place of wire planes

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

ACHILLES-GENIE Interface for Neutrino Simulations, ADRIANO2 Tile Prototype for High-Granularity Dual-Readout Calorimetry

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.]↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EBEX Balloon-borne Experiment—Detectors and Readout

EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilopixel array of transition edge sensor bolometers aboard a balloon platform. We determine the design and characterization of the array and the readout system. From the lowest to highest frequency, the median measured detectors' average thermal conductances were 39, 53, and 63 pW/K, the medians of transition temperatures were 0.45, 0.48, and 0.47 K, and the medians of normal resistances were 1.9, 1.5, and 1.4 Ω; moreover, we give the measured distributions. With the exception of the thermal conductance at 150 GHz, all measured values are within 30% of their design. We measure median low-loop-gain time constants τ 0 = 88, 46, and 57 ms. Two measurements of bolometer absorption efficiency gave results consistent within 10% and showing high (~0.9) efficiency at 150 GHz and medium (~0.35 and ~0.25) efficiency at the two higher bands. We calculate a median total optical power absorbed of 3.6, 5.3, and 5.0 pW. EBEX pioneered the use of the digital version of the frequency domain multiplexing system. We multiplexed the bias and readout of 16 bolometers onto two wires. The median per-detector noise-equivalent temperatures are 400, 920, and 14,500 $\mu {{\rm{K}}}_{{\rm{cmb}}}\sqrt{{\rm{s}}}$. We compare these values to our preflight predictions and to a previous balloon payload. We report on the sources of excess noise and the path for a future payload to make full use of the balloon environment.

instrumentation: polarimeters↗

Method for detecting and distinguishing between specific types of environmental radiation using a high pressure ionization chamber with pulse-mode readout

An environmental radiation detector for detecting and distinguishing between all types of environmental radiation, including photons, charged particles, and neutrons. A large volume high pressure ionization chamber (HPIC) includes BF.sub.3 gas at a specific concentration to render the radiation detector sensitive to the reactions of neutron capture in Boron-10 isotope. A pulse-mode readout is connected to the ionization chamber capable of measuring both the height and the width of the pulse. The heavy charged products of the neutron capture reaction deposit significant characteristic energy of the reaction in the immediate vicinity of the reaction in the gas, producing a signal with a pulse height proportional to the reaction energy, and a narrow pulse width corresponding to the essentially pointlike energy deposition in the gas. Readout of the pulse height and the pulse width parameters of the signals enables distinguishing between the different types of environmental radiation, such as gamma (x-rays), cosmic muons, and neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Dual-readout R&D for a Linear Collider in T1015 Collaboration

The hadronic energy resolution required for an hadronic operating at lepton collider is at the limits or even exceeds that obtained with traditional techniques. Furthermore, it is a well established fact that the presence of an electromagnetic section in front of an hadron calorimeter, as occurs in the layouts of the majority of detectors operating at a collider, would deteriorate the hadronic energy resolution of the device. The novel $ADRIANO$ technology (\textit{A Dual-readout Integrally Active Non-segmented Option}), currently under development at Fermilab, overcomes the above limitations by complementing an integrally active calorimeter with the dual-readout technique. Detailed Monte Carlo studies indicate that the energy resolution is in the $25\%/\sqrt{E}$ - $38\%/\sqrt{E}$ interval with a linear response of the detector up to an energy of 200 GeV. A baseline configuration is chosen with an estimated energy resolution of $\sigma(E)/E\approx30\%/\sqrt{E}$. Several prototypes have been built by \textit{T1015} Collaboration at Fermilab, to explore the effect of modifications of the layout from the baseline configuration. Preliminary results from several test beams at the \textit{Fermilab Test Beam Facility} (FTBF) of $\sim1\lambda_{I}$ prototypes are presented. Future prospects with ultra-heavy glass are, also, summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conflux – An Asynchronous 2-to-1 Multiplexor for Time-Division Multiplexing and Clock-less, Token-less Readout

This paper describes an independent, self-arbitrating asynchronous two-to-one multiplexor called Conflux. Conflux can be used to implement clock-less and token-less Time-Division Multiplexing between two sources. This capability can then be used to create a clock-less and token-less aggregate data bus which can be used as a complete asynchronous readout architecture for a chip, a part of a chip or an entire multi-chip system. Conflux utilizes a classic, four-phased asynchronous handshake on both of its input ports as well as on its output port. Asynchronous Request is bundled with Data to ensure consistent propagation delay. The Request is also differential to account for propagation delay differences between Logical Ones and Zeros. Arbitration between the two Conflux input streams is accomplished by three Set-Reset latches. Finally, Conflux cells were used successfully to implement the readout architecture of the FCP130 prototype chip. Tests indicate single Conflux stage delays of 1.8ns and a bandwidth of approximately 20 Gbps in 130nm CMOS.

43 PARTICLE ACCELERATORS↗

Dual-Readout Calorimetry for Future Experiments Probing Fundamental Physics

In this White Paper for the 2021 Snowmass process, we detail the status and prospects for dual-readout calorimetry. While all calorimeters allow estimation of energy depositions in their active material, dual-readout calorimeters aim to provide additional information on the light produced in the sensitive media via, for example, wavelength and polarization, and/or a precision timing measurements, allowing an estimation of the shower-by-shower particle content. Utilizing this knowledge of the shower particle content may allow unprecedented energy resolution for hadronic particles and jets and new types of particle flow algorithms. We also discuss the impact continued development of this kind of calorimetry could have on precision on Higgs boson property measurements at future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.