Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of readout electronics for the CMS ME0 muon detector

The Large Hadron Collider (LHC) in the High Luminosity (HL-LHC) era will be upgraded to deliver instantaneous luminosities up to 5 X 10 34 cm -2 s -1 , five times more than the original design value. In order to maintain performance of the Compact Muon Solenoid (CMS) Experiment under these conditions, ME0 is one of the new muon detectors to be added, along with GE1/1, GE2/1, RE3/1 and RE4/1. ME0 uses the triple Gas Electron Multiplier (GEM) technology and is designed to cover the far-forward region of 2.0 < |η| < 2.8. Further, the readout electronics for ME0 must be designed to deal with high data rates and be sufficiently radiation hard to operate very close to the beamline. The design and development status of the readout electronics for ME0 are presented, along with recent results from integration tests performed using the latest electronics prototypes with GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout technologies for directional WIMP Dark Matter detection

We report that the measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

79 ASTRONOMY AND ASTROPHYSICS↗

Trap-Filling Magnetoconductance as an Initialization and Readout Mechanism of Triplet Exciton Spins

Photoexcited triplet states are promising candidates for hybrid qubit systems, as they can be used as a controlling gate for nuclear spins. But microwave readout schemes do not generally offer the sensitivity needed to approach the single-molecule limit or the scope to integrate such systems into devices. In this report we demonstrate the possibility of electrical readout of triplet spins at room temperature through a specific mechanism of magnetoconductance (MC) in polycrystalline pentacene. We show that hole-only pentacene devices exhibit a positive photoinduced MC response that is consistent with a trap-filling mechanism. Spin and magnetic-field-dependent quenching of photogenerated triplets by holes quantitatively explains the MC response we observe. These results are distinct in both sign and proposed mechanism compared to previous reports on polyacene materials and provide clear design rules for future spintronic devices based on this spin-sensing mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Individual control and readout of qubits in a sub-diffraction volume

Abstract Medium-scale ensembles of coupled qubits offer a platform for near-term quantum technologies as well as studies of many-body physics. A central challenge for coherent control of such systems is the ability to measure individual quantum states without disturbing nearby qubits. Here, we demonstrate the measurement of individual qubit states in a sub-diffraction cluster by selectively exciting spectrally distinguishable nitrogen vacancy centers. We perform super-resolution localization of single centers with nanometer spatial resolution, as well as individual control and readout of spin populations. These measurements indicate a readout-induced crosstalk on non-addressed qubits below 4 × 10 −2 . This approach opens the door to high-speed control and measurement of qubit registers in mesoscopic spin clusters, with applications ranging from entanglement-enhanced sensors to error-corrected qubit registers to multiplexed quantum repeater nodes.

Bersin, Eric (ORCID:0000000306435534)↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MicroBooNE continuous readout stream for detection of supernova neutrinos

Since the original detection of core-collapse supernova neutrinos in 1987, all large neutrino experiments seek to detect the neutrinos from the next nearby supernova. Among them, liquid argon time projection chambers (LArTPCs) offer a unique sensitivity to the electron neutrino flux of a supernova. However, the low energy of these events (scale of MeVs), and the fact that all large (multi-tonne) LArTPCs operating at the moment are located near the Earth's surface, and are therefore subject to an intense cosmic ray flux, makes triggering on the supernova neutrinos very challenging. Instead, MicroBooNE has pioneered a novel approach for detecting supernova neutrinos based on a continuous readout stream and a delayed trigger generated by other neutrino detectors (the Supernova Early Warning System, or SNEWS). MicroBooNE's data is stored temporarily for a few days, awaiting a SNEWS alert to prompt the permanent recording of the data. In order to cope with the large data rates produced by the continuous readout of the TPC and the PMT systems of MicroBooNE, FPGA-based zero-suppression algorithms have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiopurity assessment of the energy readout for the NEXT double beta decay experiment

In this study, the "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136 Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr'aneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4×10 –4 counts keV –1 kg –1 y –1 , satisfying the sensitivity requirements of the NEXT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Analog pile-up circuit technique using a single capacitor for the readout of Skipper-CCD detectors

With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI) and at the same time averages the multiple samples, producing at its output the pixel value with sub-electron noise. For this purpose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experimental verification using discrete components is presented, together with an analysis of its noise sources and limitations. After averaging 400 samples it was possible to reach a readout noise of 0.18 e- rms/pix, comparable to other available readout systems. Due to its simplicity and significant reduction of the sampling requirements, this circuit technique is of particular interest in particle experiments and cameras with a high density of Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Residual Optically Stimulated Luminescent (OSL) Signals for Al 2 O 3 :C and a Readout System with Reproducible Partial Signal Clearance

Optically stimulated luminescent dosimeters (OSLDs) are devices that, when stimulated with light, emit light in proportion to the integrated ionizing radiation dose. The stimulation of OSL material results in the loss of a small fraction of signal stored within the dosimetric traps. Previous studies have investigated the signal loss due to readout stimulation, and the optical annealing of OSLDs. This study builds on former research by examining the behavior of OSL signal after annealing, exploring the functionality of a previously developed signal loss model, and comparing uncertainties for dosimeters reused with or without annealing. For a completely annealed dosimeter, the minimum signal level was 56 ± 8 counts, and readings followed a Gaussian distribution. For dosimeters above this signal level, the fractional signal loss due to the reading process has a linear relationship with the calculated signal. At low signal levels (below 20,000 counts), in this OSLD system,calculated signal percent errors increase significantly but otherwise are on average 0.72 ± 0.27%, 0.40 ± 0.19%, 0.33±0.12%, and 0.24±0.07% for 30, 75, 150, and 300 readings. Theoretical calculations of uncertainties showed that annealing before reusing dosimeters allows for dose errors below 1% with as few as 30 readings. Reusing dosimeters multiple times increases the dose errors especially with low numbers of readouts, so theoretically around 300 readings would be necessary to achieve errors around 1% or below in most scenarios. Note that these dose errors do not include the error associated with the signal-to-dose conversion factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lifetime renormalization of driven weakly anharmonic superconducting qubits. II. The readout problem

Recent experiments in superconducting qubit systems have shown an unexpectedly strong dependence of the qubit relaxation rate on the readout drive power. This phenomenon limits the maximum measurement strength and thus the achievable readout speed and fidelity. We address this problem here and provide a plausible mechanism for drive-power dependence of relaxation rates. To this end we introduce a two-parameter perturbative expansion in qubit anharmonicity and the drive amplitude through a unitary transformation technique introduced in Part I. This approach naturally reveals number-nonconserving terms in the Josephson potential as a fundamental mechanism through which applied microwave drives can activate additional relaxation mechanisms. Here, we present our results in terms of an effective master equation with renormalized state- and drive-dependent transition frequency and relaxation rates. Comparison of numerical results from this effective master equation to those obtained from a Lindblad master equation which only includes number-conserving terms (i.e., Kerr interactions) shows that number-nonconserving terms can lead to significant drive-power dependence of the relaxation rates. The systematic expansion technique introduced here is of general applicability to obtaining effective master equations for driven-dissipative quantum systems that contain weakly nonlinear degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗