Argon, radon, and tritium radioactivities in the sample return container and the lunar surface.
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fluxes and exchange coefficients are derived for the transport of Sr-90, Pb-210, Bi-210, and Po-210 between the free troposphere and the marine boundary layer and between the boundary layer and the sea surface. Radionuclide concentrations previously measured near Hawaii are used in the derivations. Values obtained for the free troposphere/boundary layer exchange coefficient (expressed as a piston velocity) were 185, 228 and 203 m/d for Pb-210, Bi-210, and Sr-90, respectively. The magnitude of the local sea-surface source of Po-210 is also determined.
A three-dimensional tracer model based on the Goddard Institude of Space Studies GCM is used to simulate the distribution of Rn-222 over North America to test the ability of the model to describe the transport of pollutants in the boundary layer and the exchange of mass between the boundary layer and the free troposphere. The model results are compared with surface observations from five sites in the U.S., showing that Rn-222 concentrations are primarily regulated by dry convection. The simulations show satisfactory agreement with observations although the model underpredicts observations at night and the simulated Rn-222 concentrations over the northeastern U.S. are too high in the spring and too low in the fall.
Abstract Not Provided
In this chapter we elucidate four main themes. The first is that modern data analyses, including "Big Data" analyses, often rely on data from different sources, which can present challenges in constructing statistical models that can make effective use of all of the data. The second theme is that although data analysis is usually centralized, frequently the final outcome is to provide information or allow decision-making for individuals. Third, data analyses often have multiple uses by design: the outcomes of the analysis are intended to be used by more than one person or group, for more than one purpose. Finally, issues of privacy and confidentiality can cause problems in more subtle ways than are usually considered; we will illustrate this point by discussing a case in which there is substantial and effective political opposition to simply acknowledging the geographic distribution of a health hazard. A researcher analyzes some data and learns something important. What happens next? What does it take for the results to make a difference in people's lives? In this chapter we tell a story - a true story - about a statistical analysis that should have changed government policy, but didn't. The project was a research success that did not make its way into policy, and we think it provides some useful insights into the interplay between locally-collected data, statistical analysis, and individual decision making.
Explore the source record for details and available documents.
The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.
An integrated field-laboratory program evaluated the use of radon and CO 2 flux measurements to constrain source and timescale of CO 2 fluxes in environments proximate to CO 2 storage reservoirs. By understanding the type and depth of the gas source, the integrity of a CO 2 storage reservoir can be assessed and monitored. The concept is based on correlations of radon and CO 2 fluxes observed in volcanic systems. This fundamental research is designed to advance the science of Monitoring, Verification, and Accounting (MVA) and to address the Carbon Storage Program goal of developing and validating technologies to ensure 99 percent storage performance. Graduate and undergraduate students conducted the research under the guidance of the Principal Investigators; in doing so they were provided with training opportunities in skills required for implementing and deploying CCS technologies. Although a final method or “tool” was not developed, significant progress was made. The field program identified issues with measuring radon in environments rich in CO 2 . Laboratory experiments determined a correction factor to apply to radon measurements made in CO 2 -bearing environments. The field program also identified issues with radon and CO 2 -flux measurements in soil gases at a natural CO 2 analog. A systematic survey of radon and CO 2 flux in soil gases at the LaBarge CO 2 Field in Southwest Wyoming indicates that measurements of 222 Rn (radon), 220 Rn (thoron), and CO 2 flux may not be a robust method for monitoring the integrity of a CO 2 storage reservoir. The field program was also not able to correlate radon and CO 2 flux in the CO 2 -charged springs of the Thermopolis hydrothermal system. However, this part of the program helped to motivate the aforementioned laboratory experiments that determined correction factors for measuring radon in CO 2 -rich environments. A graduate student earned a Master of Science degree for this part of the field program; she is currently employed with a geologic consulting company. Measurement of radon in springs has improved significantly since the field program first began; however, in situ measurement of 222 Rn and particularly 220 Rn in springs is problematic. Future refinements include simultaneous salinity measurements and systematic corrections, or adjustments to the partition coefficient as needed for more accurate radon concentration determination. A graduate student earned a Master of Science degree for this part of the field program; he is currently employed with a geologic consulting company. Both graduate students are poised to begin work in a CCS technology area. Laboratory experiments evaluated important process-level fundamentals that effect measurements of radon and CO 2 . Laboratory tests established that fine-grained source minerals yield higher radon emissivity compared to coarser-sized source minerals; subtleties in the dataset suggest that grain size alone is not fully representative of all the processes controlling the ability of radon to escape its mineral host. Emissivity for both 222 Rn and 220Rn increases linearly with temperature due to reaction of rocks with water, consistent with faster diffusion and enhanced mineral dissolution at higher temperatures. The presence of CO 2 changes the relative importance of the factors that control release of radon. Emissivity for both 222 Rn and 220 Rn in CO 2 -bearing experiments is greater at all temperatures compared to the experiments without CO 2 , but emissivity does not increase as a simple function of temperature. Governing processes may include a balance between enhanced dissolution versus carbonate mineral formation in CO 2 -rich waters.
Astronomical and cosmological observations indicate that large amounts of some slowly moving, unseen Dark Matter pervades the universe and outweighs normal matter by a factor of five. The Standard Model of Physics has no contender with the properties of this as-yet-undetected particle, so experimentalists build state-of-the-art radiation detectors to attempt to directly measure this Dark Matter. The Super Cryogenic Dark Matter Search (SuperCDMS) at Snolab is one such experiment, currently being constructed. This experiment uses ultra-cold, superconducting, high-purity silicon and germanium detectors to measure low-energy nuclear recoils from the elastic scattering of Dark Matter. I contributed to the calibration of the energy scale of low-energy nuclear recoils in CDMS II silicon detectors by computing an improved livetime correction for calibration data to verify the Monte Carlo rate normalization. Results indicate that the phonon collection efficiency of nuclear recoils relative to electron recoils is 95.2$^{+0.9}_{-0.7\%}$, and the ionization collection efficiency of low-energy nuclear recoils in silicon is lower than Lindhard prediction, consistent with other recent measurements. Backgrounds from the progeny decay of the abundant, naturally-occurring radioactive isotope radon-222 obstruct the sensitivity of essentially every dark-matter search. Radon concentrations in the Snolab cavern would contribute prohibitively large backgrounds if the volume surrounding the detectors were not purged with a low-flow low-radon gas. By measuring the radon diffusion and emanation, we identified acceptable gasket materials for sealing this radon purge, ensuring that the radon-induced backgrounds will be significantly lower than the other experimental backgrounds. A radon emanation system with a gas handling system and low-background radon detector was commissioned and used to measure the radon emanation of the proposed gaskets. A low-cost apparatus was constructed to measure the radon diffusion of gaskets with a commercial radon detector. The sensitivity of future generations of dark-matter detectors are expected to be dominated by long-lived low-energy beta- and alpha-emitting radon daughters such as 210 Pb on detector surfaces. I describe simulations indicating the detector could also be used to reduce background from material impurities plaguing rare-event searches, the commissioning of a prototype demonstration detector, and a gas handling system necessary to operate the detector. I demonstrated that the gas handling system reduces the otherwise dominant backgrounds by a factor of 62. This detector will therefore be able to detect 32 Si and 210 Pb 100 times better than currently available screeners.
The Mexican Hat, Utah, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site is located on the Navajo Reservation in southeast Utah. The US Nuclear Regulatory Commission licensed the site to the US Department of Energy Office of Legacy Management (LM) for custody and long-term care. LM manages long-term surveillance and maintenance activities at the site with the principal goal of protecting human health and the environment. The disposal cell was designed to encapsulate low-level radioactive mill tailings and other residual radioactive materials (RRM) in a way that minimizes the need for active maintenance and limits radon gas emanation and precipitation infiltration. The disposal cell has a multicomponent cover, consisting of a 60 cm thick (24 inch), low-permeability, bentonite-amended radon barrier, overlain by a 15 cm thick (6 inch) sandy gravel bedding/filter layer and a 30 cm thick (12 inch) riprap erosion-protection layer. Under UMTRCA, designs intended to control and contain RRM shall be effective for up to 1000 years, to the extent reasonably achievable and, in any case, for at least 200 years. In 2016, multiple subtle depressions were identified on the rock cover along the toe and lower portions of the northeast side slope of the disposal cell. Due to concerns regarding potential impacts to disposal cell performance and erosion resistance, evaluations of the depressions and cell cover design and construction were initiated. The evaluations included reviews of the disposal cell as-built drawings and supporting design calculations for the rock cover components. Also, in 2017, a weather monitoring station was installed at the site to collect continuous site-specific meteorological data, and repeatable ground-based light imaging, detection, and ranging (lidar) topographical and aerial photogrammetry surveys were implemented to monitor for potential changes in the surface depression features. The evaluations also included visual inspections of the depressions, and in 2018, small-area manual excavations of the rock cover components (test pits) were performed to observe the conditions of the cover components, scan for radioactivity, and observe evidence of erosion on the surface of the radon barrier material. Voids and incisions were discovered within the radon barrier on the north and northeast side slopes of the disposal cell. Visual observations at test pits indicate that the bedding/filter material is highly segregated and may not be in conformance with the disposal cell engineering and construction design specifications. Post-construction development of a weak to strongly cemented material has also been observed immediately below the base of the bedding layer in test pits with observed radon barrier degradation. A series of radiological surveys have been performed at the site, and radiological readings have not exceeded natural background conditions in the vicinity of the site. Thus, the site remains protective of human health and the environment. Implementation of continuous radiological monitoring at the site will be initiated in fall 2018 through the deployment of radon cups and thermoluminescent dosimeters to obtain data that provides supporting evidence that the disposal cell remains protective of human health and the environment. Evaluations to determine the cause(s) of the depression features and associated radon barrier erosion are ongoing. Possible mechanisms of cover degradation identified thus far include segregated bedding material that would allow for higher precipitation runoff velocities, resulting in erosion of the radon barrier; post-construction cementation of radon barrier or aeolian material that could negatively affect the performance of the radon barrier; cation exchange leading to the development of cementation; and aeolian deposition affecting precipitation runoff. Moreover, geotechnical sampling and testing is planned to verify spatial cover conditions relative to design specifications. The resulting information will be used to identify possible causes for the surface depressions and associated radon barrier degradation, gain insight on potential long-term performance implications along the side slopes of the disposal cell, and identify potential corrective actions. (authors)
Characterizing the interplay between exposures shaping the human exposome is vital for uncovering the etiology of complex diseases. For example, cancer risk is modified by a range of multifactorial external environmental exposures. Environmental, socioeconomic, and lifestyle factors all shape lung cancer risk. However, epidemiological studies of radon aimed at identifying populations at high risk for lung cancer often fail to consider multiple exposures simultaneously. For example, moderating factors, such as PM 2.5 , may affect the transport of radon progeny to lung tissue. This ecological analysis leveraged a population-level dataset from the National Cancer Institute’s Surveillance, Epidemiology, and End-Results data (2013–17) to simultaneously investigate the effect of multiple sources of low-dose radiation (gross γ activity and indoor radon) and PM 2.5 on lung cancer incidence rates in the USA. County-level factors (environmental, sociodemographic, lifestyle) were controlled for, and Poisson regression and random forest models were used to assess the association between radon exposure and lung and bronchus cancer incidence rates. Tree-based machine learning (ML) method perform better than traditional regression: Poisson regression: 6.29/7.13 (mean absolute percentage error, MAPE), 12.70/12.77 (root mean square error, RMSE); Poisson random forest regression: 1.22/1.16 (MAPE), 8.01/8.15 (RMSE). The effect of PM 2.5 increased with the concentration of environmental radon, thereby confirming findings from previous studies that investigated the possible synergistic effect of radon and PM 2.5 on health outcomes. In summary, the results demonstrated (1) a need to consider multiple environmental exposures when assessing radon exposure’s association with lung cancer risk, thereby highlighting (1) the importance of an exposomics framework and (2) that employing ML models may capture the complex interplay between environmental exposures and health, as in the case of indoor radon exposure and lung cancer incidence.
The SuperNEMO experiment will search for neutrinoless double beta decay (0νββ) with a target sensitivity of T{sub 1/2}(0ν) > 10{sup 26} years, corresponding to an effective neutrino mass of 50-100 meV. At its heart there is a low-background gaseous tracking detector which allows for extremely efficient background rejection and, if 0νββ is observed, may provide important insights into the mechanism via which it may be mediated. Radon inside the tracker, which can mimic rare ββ events, is one of the most dangerous backgrounds for SuperNEMO. To reach the target sensitivity the radon concentration inside the tracking volume must be < 0.15 mBq/m{sup 3}. To reach this challengingly-low level of radon, a considerable program of R and D has been undertaken. This includes automation of the tracker-wiring process, development of a dedicated setup to measure radon diffusion and a 'radon concentration line' which will be able to measure levels of radon in the μBq/m{sup 3} range.
Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.