Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

International scientific collaboration: the Radiation Measurements Cross Calibration (RMCC) project.

Detecting the presence of radioactive sources, preventing the illicit use of radiological materials, supporting arms control treaties, responding to accidental radiation releases, and disposing of radioactive sources safely and securely are common concerns in the Middle East. The Radiation Measurements Cross Calibration (RMCC) project aims to improve radiation measurement capabilities across the region and establish common standards. The RMCC project has been an ongoing initiative for the last twelve years. Its goal is to build core competencies in radioanalysis in the Middle East by facilitating the exchange of expertise and fostering dialogue to improve methods and strengthen a growing network. This year the Middle East Scientific Institute for Security (MESIS) in Amman, Jordan assumed leadership of the RMCC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Resonance Fluorescence for Materials Assay

This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX's photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Resonance Fluorescence for Materials Assay

This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX?s photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed Characterization of Nuclear Recoil Pulse Shape Discrimination in the DarkSide-50 Direct Dark Matter Experiment

While evidence of non-baryonic dark matter has been accumulating for decades, its exact nature continues to remain a mystery. Weakly Interacting Massive Particles (WIMPs) are a well motivated candidate which appear in certain extensions of the Standard Model, independently of dark matter theory. If such particles exist, they should occasionally interact with particles of normal matter, producing a signal which may be detected. The DarkSide-50 direct dark matter experiment aims to detect the energy of recoiling argon atoms due to the elastic scattering of postulated WIMPs. In order to make such a discovery, a clear understanding of both the background and signal region is essential. This understanding requires a careful study of the detector's response to radioactive sources, which in turn requires such sources may be safely introduced into or near the detector volume and reliably removed. The CALibration Insertaion System (CALIS) was designed and built for this purpose in a j oint effort between Fermi National Laboratory and the University of Hawaii. This work describes the design and testing of CALIS, its installation and commissioning at the Laboratori Nazionali del Gran Sasso (LNGS) and the multiple calibration campaigns which have successfully employed it. As nuclear recoils produced by WIMPs are indistinguishable from those produced by neutrons, radiogenic neutrons are both the most dangerous class of background and a vital calibration source for the study of the potential WIMP signal. Prior to the calibration of DarkSide-50 with radioactive neutron sources, the acceptance region was determined by the extrapolation of nuclear recoil data from a separate, dedicated experiment, ScENE, which measured the distribution of the pulse shape discrimination parameter, $f_{90}$, for nuclear recoils of known energies. This work demonstrates the validity of the extrapolation of ScENE values to DarkSide-50, by direct comparison of the $f_{90}$ distributio n of nuclear recoils from ScENE and an AmBe calibration sour! ce. The combined acceptance as defined by ScENE and the \textit{in-situ} AmBe calibration were used to establish the best WIMP exclusion limit on an argon target. Unfortunately, radioactive sources used for the calibration of DarkSide-50 are universally accompanied by gamma decays, which obscure the low energy region where most WIMP interactions are expected to occur and seem to make continuing dependence on an external measurement such as ScENE inevitable. However, this work presents a novel method of nuclear recoil calibration employing event selection, unique to the design of DarkSide-50, which produces a nearly pure sample of nuclear recoils. Further, it describes the execution of a neutron calibration campaign, from planning to analysis, which yielded a valuable data set for defining the acceptance region. Together with the event selection techniques, this allows for the definition of the acceptance region independent of ScENE values. Two analytical models of the $f_{90 }$ distribution are described and their results for nuclear recoils are compared. Finally, a detailed study of integrated noise in nuclear and electron recoil

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Advanced Source Identification Algorithm (ASIA-NEW) for radiation monitors with plastic detectors

Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the authors and based on some experimental test results. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co-57, Ba-133 and other). New variant of ASIA is based on physical principles and does not require a lot of special tests to attain statistical data for its parameters. That is why this system can be easily installed into any RPM with plastic detectors. This algorithm was tested for 1,395 passages of different transports (cars, trucks and trailers) without radioactive sources. It also was tested for 4,015 passages of these transports with radioactive sources of different activity (Co-57, Ba-133, Cs-137, Co-60, Ra-226, Th-232) and these sources masked by NORM (K-40) as well. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental approaches for the development of gamma spectroscopy well logging system

This article discusses experimental approaches for the development of gamma spectroscopy well logging system. Considering the size of borehole sonde, we customize 2 x 2 inches inorganic scintillators and the system including high voltage, preamplifier, amplifier and multichannel analyzer (MCA). The calibration chart is made by test using standard radioactive sources so that the measured count rates are expressed by energy spectrum. Optimum high-voltage supplies and the measurement parameters of each detector are set up by experimental investigation. Also, the responses of scintillation detectors have been examined by analysis according to the distance between source and detector. Because gamma spectroscopy well logging needs broad spectrum, high sensitivity and resolution, the energy resolution and sensitivity as a function of gamma ray energy are investigated by analyzing the gamma ray activities of the radioactive sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-J-09: Radioactive Seed Localization for Breast Lumpectomy - Towards Optimization

Purpose: The aim of this work is to propose a method to optimize radioactive source localization (RSL) for non-palpable breast cancer surgery. RSL is commonly used as a guiding technique during surgery for excision of non-palpable tumors. A collimated hand-held detector is used to localize radioactive sources implanted in tumors. Incisions made by the surgeon are based on maximum observed detector counts, and tumors are subsequently resected based on an arbitrary estimate of the counts expected at the surgical margin boundary. This work focuses on building a framework to predict detector counts expected throughout the procedure to improve surgical margins. Methods: A gamma detection system called the Neoprobe GDS was used for this work. The probe consists of a cesium zinc telluride crystal and a collimator. For this work, an I-125 Best Medical model 2301 source was used. The source was placed in three different phantoms, a PMMA, a Breast (25%- glandular tissue/75%- adipose tissue) and a Breast (75-25) phantom with a backscatter thickness of 6 cm. Counts detected by the probe were recorded with varying amounts of phantom thicknesses placed on top of the source. A calibration curve was generated using MATLAB based on the counts recorded for the calibration dataset acquired with the PMMA phantom. Results: The observed detector counts data used as the validation set was accurately predicted to within ±3.2%, ±6.9%, ±8.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. The average difference between predicted and observed counts was −0.4%, 2.4%, 1.4% with a standard deviation of 1.2 %, 1.8%, 3.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. Conclusion: The results of this work provide a basis for characterization of a detector used for RSL. Counts were predicted to within ±9% for three different phantoms without the application of a density correction factor.

60 APPLIED LIFE SCIENCES↗

Calibration of the GLAST Burst Monitor Detectors

The GLAST Burst Monitor (GBM) will augment the capabilities of GLAST for the detection of cosmic gamma-ray bursts by extending the energy range (20 MeV to > 300 GeV) of the Large Area Telescope (LAT) towards lower energies by 2 BGO-detectors (150 keV to 30 MeV) and 12 NaI(Tl) detectors (10 keV to 1 MeV). The physical detector response of the GBM instrument for GRBs is determined with the help of Monte Carlo simulations, which are supported and verified by on-ground calibration measurements, performed extensively with the individual detectors at the MPE in 2005. All flight and spare detectors were irradiated with calibrated radioactive sources in the laboratory (from 14 keV to 4.43 MeV). The energy/channel-relations, the dependences of energy resolution and effective areas on the energy and the angular responses were measured. Due to the low number of emission lines of radioactive sources below 100 keV, calibration measurements in the energy range from 10 keV to 60 keV were performed with the X-ray radiometry working group of the Physikalisch-Technische Bundesanstalt (PTB) at the BESSY synchrotron radiation facility, Berlin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solution-grown crystals for neutron radiation detectors, and methods of solution growth

An organic crystal according to one embodiment includes an organic crystal comprising diphenylacetylene and stilbene or a stilbene derivative, the crystal having physical characteristics of formation from solution, the organic crystal exhibiting a signal response signature for neutrons from a radioactive source. A system according to one embodiment includes an organic crystal comprising diphenylacetylene and stilbene or a stilbene derivative, the crystal having physical characteristics of formation from solution, the organic crystal exhibiting a signal response signature for neutrons from a radioactive source; and a photodetector for detecting the signal response of the organic crystal. Methods of making such crystals are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operating experience in the treatment and storage of LLW in Turkey - 15010

Treatment and storage of low-level radioactive wastes (LLW) are being carried out in Radioactive Waste Management Unit (RWMU) at Cekmece Nuclear Research and Training Center (CNRTC) in Istanbul. The wastes are generated from nuclear research and nuclear applications mainly in medicine, biology, ng to these specifications, LLW are classified as exempt waste, very low level waste (VLLW) etc. Decay storage is applied at a designated area for short lived radionuclide. Long lived spent radioactive sources are immobilized in retrievable packages. Generally liquid radioactive wastes are decontaminated by filtration or chemical precipitation. The radioactive sludge or filtration media from liquid waste processing is solidified using cementation. Solid waste is compacted into drums for size reduction. TENORM wastes and contaminated metal wastes are handled for decontamination and size reduction. Then these types of waste are placed in 20 ton bulk containers for long term storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The HRA/Solarium Project: Feedback Based on 20 Years of Experience in Treatment of Medium Level Waste - 20185

Since the 1980's the management of the historical site of Mol has been transferred to the National Agency for Radioactive Waste and Enriched Fissile Materials (ONDRAF/NIRAS). Belgoprocess is entrusted by ONDRAF/NIRAS with the operational waste management and site remediation. One of the major challenges has been the characterization, treatment and conditioning of approximately 200 m{sup 3} of medium level waste. These waste packages were stored in poor conditions in storage vaults ('HRA') or concrete containers ('Solarium'). They have been produced in various research programs and reactor operations at the Belgian nuclear energy research centre SCK.CEN, isotope production, decontamination and dismantling operations from the 1960's up to the 1980's. Despite the limited volume, this historical waste consists of a great variation of waste characteristics and waste configurations. To tackle these liabilities, a new processing facility was built in the 1990's to allow safe transfers, handling, characterization and treatment of these packages. Also some auxiliary facilities have been built to deal with the by-products, like emptied concrete containers. The engineering of the installation, safety procedures and (characterization) methodology that has been developed generically have been proved to be successful. Nevertheless, the specific nature of some items made it necessary to organize a step-by-step treatment in distinct campaigns in which some relevant extra (safety) measures had to be taken into account. This dynamic approach made it possible to process a great variety of waste types in order to to ensure that this legacy is no longer left for subsequent generations. After about 20 years of operations, there has been a great build-up of experience and feed-back concerning the waste management of these specific waste streams. Some cases will be highlighted to specify the approach followed for treatment of e.g.: - Na/NaK containing equipment; - spent radioactive sources; - fuel element residues; - medium level waste originating from activation experiments; - radium bearing medium level waste originating from Ac-227 production research. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-ray Spectrometer

The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.

79 ASTRONOMY AND ASTROPHYSICS↗

Radioactive heat sources in the lunar interior.

Published models for the moon's thermal history typically imply present day central temperatures far too high to be consistent with the recently proposed lunar temperature profile of Sonett et al. (1971). Furthermore, chemical data on Apollo samples show that the moon is depleted relative to chondrites in volatile elements, and possibly enriched relative to chondrites in refractory elements. Additional thermal models have therefore been investigated in order to set upper limits on lunar radioactivity consistent with the proposed temperature distribution. For an initially cold, uniform moon, devoid of potassium, a maximum uranium content of 23 parts per billion is inferred.

Hays, J. F.↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Mixed crystal organic scintillators

A mixed organic crystal according to one embodiment includes a single mixed crystal having two compounds with different bandgap energies, the organic crystal having a physical property of exhibiting a signal response signature for neutrons from a radioactive source, wherein the signal response signature does not include a significantly-delayed luminescence characteristic of neutrons interacting with the organic crystal relative to a luminescence characteristic of gamma rays interacting with the organic crystal. According to one embodiment, an organic crystal includes bibenzyl and stilbene or a stilbene derivative, the organic crystal having a physical property of exhibiting a signal response signature for neutrons from a radioactive source.

36 MATERIALS SCIENCE↗