Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Evaluation of Radiation Dose Effects on Rat Bones Using Synchrotron Radiation Computed Microtomography

In this work, we investigated the consequences of irradiation in the femora and ribs of rats submitted to radiation doses of 5 Gy. Three different sites in femur specimens (head, distal metaphysis and distal epiphysis) and one in ribs (ventral) were imaged using synchrotron radiation microcomputed tomography to assess trabecular bone microarchitecture. Histomorphometric quantification was calculated directly from the 3D microtomographic images using synchrotron radiation. The 3D microtomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. A better understanding of the biological interactions that occur after exposure to photon radiation is needed in order to optimize therapeutic regimens and facilitate development and strategies that decrease radiation-induced side effects in humans. Results showed significant differences between irradiated and non-irradiated specimens, mostly in head and distal metaphysis bone sites.

60 APPLIED LIFE SCIENCES↗

Radiation defect dynamics in Si at room temperature studied by pulsed ion beams

The evolution of radiation defects after the thermalization of collision cascades often plays the dominant role in the formation of stable radiation disorder in crystalline solids of interest to electronics and nuclear materials applications. Here, we explore a pulsed-ion-beam method to study defect interaction dynamics in Si crystals bombarded at room temperature with 500 keV Ne, Ar, Kr, and Xe ions. The effective time constant of defect interaction is measured directly by studying the dependence of lattice disorder, monitored by ion channeling, on the passive part of the beam duty cycle. The effective defect diffusion length is revealed by the dependence of damage on the active part of the beam duty cycle. Results show that the defect relaxation behavior obeys a second order kinetic process for all the cases studied, with a time constant in the range of ∼4–13 ms and a diffusion length of ∼15–50 nm. Both radiation dynamics parameters (the time constant and diffusion length) are essentially independent of the maximum instantaneous dose rate, total ion dose, and dopant concentration within the ranges studied. However, both the time constant and diffusion length increase with increasing ion mass. This demonstrates that the density of collision cascades influences not only defect production and annealing efficiencies but also the defect interaction dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-targeted and delayed effects of exposure to ionizing radiation: I. Radiation-induced genomic instability and bystander effects in vitro

A long-standing dogma in the radiation sciences is that energy from radiation must be deposited in the cell nucleus to elicit a biological effect. A number of non-targeted, delayed effects of ionizing radiation have been described that challenge this dogma and pose new challenges to evaluating potential hazards associated with radiation exposure. These effects include induced genomic instability and non-targeted bystander effects. The in vitro evidence for non-targeted effects in radiation biology will be reviewed, but the question as to how one extrapolates from these in vitro observations to the risk of radiation-induced adverse health effects such as cancer remains open.

Review, Tutorial↗

Mometasone Furoate Cream Reduces Acute Radiation Dermatitis in Patients Receiving Breast Radiation Therapy: Results of a Randomized Trial

Purpose: We wanted to confirm the benefit of mometasone furoate (MF) in preventing acute radiation reactions, as shown in a previous study (Boström et al, Radiother Oncol 2001;59:257-265). Methods and Materials: The study was a double-blind comparison of MF with D (Diprobase), administered daily from the start of radiation therapy for 5 weeks in patients receiving breast radiation therapy, 40 Gy in 2.67-Gy fractions daily over 3 weeks. The primary endpoint was mean modified Radiation Therapy Oncology Group (RTOG) score. Results: Mean RTOG scores were significantly less for MF than for D (P=.046). Maximum RTOG and mean erythema scores were significantly less for MF than for D (P=.018 and P=.012, respectively). The Dermatology Life Quality Index (DLQI) score was significantly less for MF than for D at weeks 4 and 5 when corrected for Hospital Anxiety and Depression (HAD) questionnaire scores. Conclusions: MF cream significantly reduces radiation dermatitis when applied to the breast during and after radiation therapy. For the first time, we have shown a significantly beneficial effect on quality of life using a validated instrument (DLQI), for a topical steroid cream. We believe that application of this cream should be the standard of care where radiation dermatitis is expected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Cloud Top Longwave Radiative Cooling Due To the Effect of Horizontal Radiative Transfer in the Stratocumulus to Trade Cumulus Transition Regime

Abstract Recent studies develop the SPeedy Algorithm for Radiative TrAnsfer through CloUd Sides (SPARTACUS) to handle the influence of horizontal RT on vertical radiative fluxes within an atmospheric column. The present study applies SPARTACUS to large eddy simulation (LES)‐generated cloud fields across the stratocumulus to trade cumulus transition (STCT) regime with coarse and fine vertical resolutions. The results show that, as the vertical resolution increases, radiation simulations show increasingly stronger cloud‐top longwave (LW) radiative cooling. Consequently, the sharp radiative heating gradient across the cloud layer in the LES‐like resolution simulations cannot be resolved with the coarse resolution simulations. Including the horizontal RT typically enhances cloud LW radiative cooling rate by less than 10% for all the cloud fields but more significantly in the cloud fields during the STCT. The enhanced cloud LW radiative cooling also occurs in the lower cloud layer in the decoupled cumulus cloud regime.

Geology↗

Effect of number of stack on the thermal escape and non-radiative and radiative recombinations of photoexcited carriers in strain-balanced InGaAs/GaAsP multiple quantum-well-inserted solar cells

Three non-destructive methodologies, namely, surface photovoltage (SPV), photoluminescence, and piezoelectric photothermal (PPT) spectroscopies, were adopted to detect the thermal carrier escape from quantum well (QW) and radiative and non-radiative carrier recombinations, respectively, in strain-balanced InGaAs/GaAsP multiple-quantum-well (MQW)-inserted GaAs p-i-n solar cell structure samples. Although the optical absorbance signal intensity was proportional to the number of QW stack, the signal intensities of the SPV and PPT methods decreased at high number of stack. To explain the temperature dependency of these signal intensities, we proposed a model that considers the three carrier dynamics: the thermal escape from the QW, and the non-radiative and radiative carrier recombinations within the QW. From the fitting procedures, it was estimated that the activation energies of the thermal escape ΔE{sub barr} and non-radiative recombination ΔE{sub NR} were 68 and 29 meV, respectively, for a 30-stacked MQW sample. The estimated ΔE{sub barr} value agreed well with the difference between the first electron subband and the top of the potential barrier in the conduction band. We found that ΔE{sub barr} remained constant at approximately 70 meV even with increasing QW stack number. However, the ΔE{sub NR} value monotonically increased with the increase in the number of stack. Since this implies that non-radiative recombination becomes improbable as the number of stack increases, we found that the radiative recombination probability for electrons photoexcited within the QW increased at a large number of QW stack. Additional processes of escaping and recapturing of carriers at neighboring QW were discussed. As a result, the combination of the three non-destructive methodologies provided us new insights for optimizing the MQW components to further improve the cell performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Plasma radiation behavior approaching high-radiation scenarios in W7-X

The W7-X stellarator has so far performed experiments under both limiter and divertor conditions. The plasma is mostly generated by ECR-heating with powers up to 6.5 MW, and the plasma density is usually limited by the radiation losses from low-Z impurities (such as carbon and oxygen) released mainly from the graphite targets. The present work first summarizes the radiation loss fractions f rad achieved in quasi-stationary hydrogen plasmas in both operational phases, and then shows how impurity radiation behaves differently with the two different boundary conditions as the plasma density increases. The divertor operation is emphasized and some beneficial effects (with respect to impurity radiation) are highlighted: (1) intensive radiation is located at the edge (r/a > 0.8) even at high radiation loss fractions, (2) the plasma remains stable up to f rad approaching unity, (3) the reduction in the stored energy is about 10% for high f rad scenarios. Moreover, effects of wall boronisation on impurity radiation profiles are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Radiation, Radiation Measurement and the JLab APEX Experiment

The A-prime Experiment (APEX), which is approved to run at the Thomas Jefferson Accelerator Facility (JLab) Hall A, will search for a new vector boson that is hypothesized to be a possible force carrier that couples to dark matter. APEX results should be sensitive to the mass range of 65 MeV to 550 MeV, and high sensitivity will be achieved by means of a high intensity 100 muA beam on a 0.3 g/cm 2 Tungsten target resulting in very high luminosity. The experiment should be able to observe an A-prime with a coupling constant 1 x 10 7 times smaller than the electromagnetic coupling constant. To deal safely with such enormous intensity and luminosity, a full radiation analysis must be used. A Geant4 Monte Carlo simulation was performed to study the radiation environments expected in the JLab Hall A during the APEX experiment. We benchmarked our simulations with measurements carried out during past experiments such as the Pb Radius Experiment (PREX-I). Our PREX-I simulations agreed reasonably well with measurements performed by measuring the change in dark current in a Silicon Photomultipliers as a means of radiation damage. However, our simulations were initially significantly higher than the neutron dose measurements (using NP100) in Hall A. The apparent disagreement hints to several potential problems in NP100 measurements including the dead-time. Further, we identified radiation sources in the beam line and tested several shielding strategies to lower the radiation in Hall A. We characterized several thermal neutron detectors and also studied possibility of damage to electronics due to neutron radiation. We successfully demonstrated that the APEX experiment can be carried out in JLab Hall A without worrying about radiation damage to expensive electronics. The A-prime will appear as a narrow resonance in the invariant mass spectrum of e + e - pairs resulting from the electron beam scattering off the APEX target. In this search for the A-prime, it is critical to have a good mass resolution which is mainly dominated by the track measurement uncertainties. We studied a novel method to calibrate the HRS optics which will improve the accuracy of track measurements. Our results will be used to design HRS calibration runs for the APEX experiment.

Kaluarachchi, Maduka↗

The radiation balance of the earth-atmosphere system from Nimbus 3 radiation measurements

The radiation balance of the earth-atmosphere system and its components was computed from global measurements of radiation reflected and emitted from the earth to space. These measurements were made from the meteorological satellite Nimbus 3 during the periods from April 16 to August 15, 1969; October 3 to 17, 1969; and January 21 to February 3, 1970. Primarily the method of evaluation, its inherent assumptions, and possible error sources were discussed. Results are presented by various methods: (1) global, hemispherical, and zonal averages obtained from measurements in all semimonthly periods and (2) global maps of the absorbed solar radiation, the albedo, the outgoing longwave radiation, and the radiation balance obtained from measurements during semimonthly periods in each season (May 1 to 15, July 16 to 31, and October 3 to 17, 1969, and January 21 to February 3, 1970). Annual global averages of the albedo and of the outgoing longwave radiation were determined. These values balance to within 1 percent the annual global energy input by solar radiation that was computed for a solar constant.

Raschke, E.↗

The generation of transition radiation by relativistic particles in plastic foam radiators

The design of large area transition radiation detectors for highly relativistic particles can be greatly simplified if plastic foam radiators are employed. Using electron beams with energies 1-9 GeV at the Cornell synchrotron, we have studied the properties of a large variety of transition radiators consisting of commercially available foam materials. In most cases, a measurable transition radiation signal has been observed, but only a few materials have been found to be suitable for practical purposes. The observed radiation yield is in these cases very similar to that of equivalent multifoil radiators. A detailed discussion is given of the particle detection efficiency that can be obtained with high yield foam radiators.

Prince, T. A.↗

The effect of directional radiation models on the interpretation of earth radiation budget measurements

A parameter estimation technique is presented to estimate the radiative flux density distribution over the earth from a set of radiometer measurements at satellite altitude. The technique analyzes measurements from a wide field of view, horizon to horizon, nadir pointing sensor with a mathematical technique to derive the radiative flux density estimates at the top of the atmosphere for resolution elements smaller than the sensor field of view. A computer simulation of the data analysis technique is presented for both earth-emitted and reflected radiation. The errors resulting from the assumed directional radiation model, spatial model and random measurement error have little effect on the global mean radiation. Zonal estimates were found to be more sensitive to the spatial model than to the directional radiation model. Results from analyzing medium field of view measurements showed a much greater sensitivity to the directional radiation model even on a global scale.

Green, R. N.↗

Development of a high-performance cryogenic radiator with V-groove radiation shields

A feasibility demonstration model of a new-technology, high-performance, cryogenic radiative cooler has been successfully tested in a helium-cooled vacuum chamber. Thermal isolation of the radiator cold stage from the warm spacecraft and instrument is achieved by a novel arrangement of lightweight radiation shields which form large V-groove cavities, and by the use of low-conductance structural supports. The vacuum chamber experiments demonstrate the thermal isolation capability of the radiator design. Analytical model predictions are all within 1 K of the measured test temperatures. Utilization of this design enables reasonably sized radiative coolers (less than 0.3 sq m) to achieve operating temperatures below 60 K at earth, Mars, and beyond for useful cooling loads below 75 mW. The design can be scaled to accommodate larger heat loads. The reduction in operating temperature of over 15 K relative to any radiative cooler flown in the past will allow the V-groove isolation radiator to meet the challenging instrument cooling requirements of many future space missions.

Bard, Steven↗

Test problems for radiation and radiation-hydrodynamics codes

A number of test problems for radiation and radiation-hydrodynamics computer codes are described. These include evolution to radiative equilibrium, cooling from radiative equilibrium, subcritical and supercritical radiating shocks, and a radiating blast wave in a power-law density distribution. For each test problem, example input parameters and plots of the results are presented. Some test problems for pure hydrodynamics are also suggested. The radiation-hydrodynamics code used to perform the example test problems and the equations it solves are described in some detail.

Ensman, Lisa↗

The Role of Clear Sky Identification in the Study of Cloud Radiative Effects: Combine Analysis from ISCCP and the Scanner of Radiation Budget (ScaRaB)

Since the effect of clouds on the earth's radiation balance is often estimated as the difference of net radiative fluxes at the top of the atmosphere between all situations and monthly averaged clear sky situations of the same regions, a reliable identification of clear sky is important for the study of cloud radiative effects. The Scanner for Radiation Balance (ScaRaB) radiometer on board the Russian Meteor-3/7 satellite provided earth radiation budget observations from March 1994 to February 1995 with two ERBE-Re broad-band longwave and shortwave channels. Two narrow-band channels, in the infrared atmospheric window and in the visible band, have been added to the ScaRaB instrument to improve the cloud scene identification. The International Satellite Cloud Climatology Project (ISCCP) method for cloud detection and determination of cloud and surface properties uses the same narrow-band channels as ScaRaB, but is employed to a collection of measurements at a better spatial resolution of about 5 km. By applying the original ISCCP algorithms to the ScaRaB data, the clear sky frequency is about 5% lower than the one over quasi-simultaneous original ISCCP data, an indication that the ISCCP cloud detection is quite stable. However, one would expect an about 10 to 20% smaller clear sky occurrence over the larger ScaRaB pixels. Adapting the ISCCP algorithms to the reduced spatial resolution of 60 km and to the different time sampling of the ScaRaB data leads therefore to a reduction of a residual cloud contamination. A sensitivity study with time-space collocated ScaRaB and original ISCCP data at a spatial resolution of 1deg longitude x 1deg latitude shows that the effect of clear sky identification method plays a higher role on the clear sky frequency and therefore on the statistics than on the zonal mean values of the clear sky fluxes. Nevertheless, the zonal outgoing longwave fluxes corresponding to ERBE clear sky are in general about 2 to 10 W/sq m higher than those obtained from the ScaRaB adapted ISCCP clear sky identifications. The latter are close to (about 1 W/sq m higher) fluxes corresponding to clear sky regions from original ISCCP data, whereas ScaRaB clear sky LW fluxes obtained with the original ISCCP identification lie about 1 to 2 W/sq m below. Especially in the tropics where water vapor abundance is high, the ERBE clear sky LW fluxes seem to be systematically overestimated by about 4 W/sq m, and SW fluxes are lower by about 5 to 10 W/sq m. However, the uncertainty in the analysis of monthly mean zonal cloud radiative effects is also produced by the low frequency of clear sky occurrence, illustrated when averaging over pixels or even over regions of 4deg longitude x 5deg latitude, corresponding to the spatial resolution of General Circulation Models. The systematic bias in the clear sky fluxes is not reflected in the zonal cloud radiative effects, because the clear sky regions selected by the different algorithms can occur in different geographic regions with different cloud properties.

Rossow, W. B.↗

Radiation Risk Assessment of the Individual Astronaut: A Complement to Radiation Interests at the NIH

Predicting human risks following exposure to space radiation is uncertain in part because of unpredictable distribution of high-LET and low-dose-derived damage amongst cells in tissues, unknown synergistic effects of microgravity upon gene- and protein-expression, and inadequately modeled processing of radiation-induced damage within cells to produce rare and late-appearing malignant cancers. Furthermore, estimation of risks of radiogenic outcome within small numbers of astronauts is not possible using classic epidemiologic study. It therefore seems useful to develop strategies of risk-assessment based upon large datasets acquired from correlated biological models useful for resolving radiogenic risk-assessment for irradiated individuals. In this regard, it is suggested that sensitive cellular biodosimeters that simultaneously report 1) the quantity of absorbed dose after exposure to ionizing radiation, 2) the quality of radiation delivering that dose, and 3) the biomolecular risk of malignant transformation be developed in order to resolve these NASA-specific challenges. Multiparametric cellular biodosimeters could be developed using analyses of gene-expression and protein-expression whereby large datasets of cellular response to radiation-induced damage are analyzed for markers predictive for acute response as well as cancer-risk. A new paradigm is accordingly addressed wherein genomic and proteomic datasets are registered and interrogated in order to provide statistically significant dose-dependent risk estimation in individual astronauts. This evaluation of the individual for assessment of radiogenic outcomes connects to NIH program in that such a paradigm also supports assignment of a given patient to a specific therapy, the diagnosis of response of that patient to therapy, and the prediction of risks accumulated by that patient during therapy - such as risks incurred by scatter and neutrons produced during high-energy Intensity-Modulated Radiation Therapy. Value of assessment of radiogenic outcome for individuals exposed to radiation is suggested to be common to both NASA and NIH.

Richmond, Robert C.↗