Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-T-206: Improving Radiotherapy Toxicity Based On Artificial Neural Network (ANN) for Head and Neck Cancer Patients

Purpose/Objective(s): The aim of this study is to build the estimator of toxicity using artificial neural network (ANN) for head and neck cancer patients Materials/Methods: An ANN can combine variables into a predictive model during training and considered all possible correlations of variables. We constructed an ANN based on the data from 73 patients with advanced H and N cancer treated with external beam radiotherapy and/or chemotherapy at our institution. For the toxicity estimator we defined input data including age, sex, site, stage, pathology, status of chemo, technique of external beam radiation therapy (EBRT), length of treatment, dose of EBRT, status of post operation, length of follow-up, the status of local recurrences and distant metastasis. These data were digitized based on the significance and fed to the ANN as input nodes. We used 20 hidden nodes (for the 13 input nodes) to take care of the correlations of input nodes. For training ANN, we divided data into three subsets such as training set, validation set and test set. Finally, we built the estimator for the toxicity from ANN output. Results: We used 13 input variables including the status of local recurrences and distant metastasis and 20 hidden nodes for correlations. 59 patients for training set, 7 patients for validation set and 7 patients for test set and fed the inputs to Matlab neural network fitting tool. We trained the data within 15% of errors of outcome. In the end we have the toxicity estimation with 74% of accuracy. Conclusion: We proved in principle that ANN can be a very useful tool for predicting the RT outcomes for high risk H and N patients. Currently we are improving the results using cross validation.

60 APPLIED LIFE SCIENCES↗

Absolute Bunch Length Measurements at the ALS by Incoherent Synchrotron Radiation Fluctuation Analysis

By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and tested a simple scheme based on this principle that allows for the absolute measurement of the bunch length. A description of the method and the experimental results are presented.

43 PARTICLE ACCELERATORS↗

Terahertz and Optical Measurement Apparatus for the Fermilab ASTA Injector

ASTA is a facility at Fermilab that, once completed, will consist of a photoinjector with two superconducting capture cavities, at least one superconducting ILC-style cryomodule, and a small ring for studying non-linear, integrable beam optics. This paper discusses the layout for the optical transport system that will provide THz radiation to a Martin-Puplett interferometer for bunch length measurements as well as optical radiation to an externally located streak camera, also for bunch length measurements. It will be able to accept radiation from two synchrotron radiation ports in the bunch compressor, a diffraction/transition radiation screen downstream of the compressor, and a transition radiation screen after the spectrometer magnet for measurements of energy-time correlations.

Thurman-Keup, R.↗

Tracking seasonal variability in plant traits from spaceborne PRISMA and NEON AOP across forest types and ecoregions

Plant traits serve as critical indicators of how plants adapt to environmental changes and influence ecosystem functions. While airborne hyperspectral remote sensing effectively maps plant traits through detailed reflectance properties, it is limited by cost and scale, making large-scale and temporal studies challenging. The recently launched spaceborne hyperspectral imager, PRecursore IperSpettrale della Missione Applicativa (PRISMA), offers frequent, large scale and high-fidelity observations on a spatial resolution of 30 m and a revisit time of around 29 days, making it suitable for large-scale seasonal trait mapping. However, their potential remains largely unexplored. This study developed a multi-stage framework by leveraging the PRISMA spaceborne hyperspectral data and National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) hyperspectral data to investigate the seasonal dynamics of four key plant traits — chlorophyll content, carotenoid content, equivalent water thickness, and nitrogen content — across eleven NEON sites representing diverse forest types and ecoregions in the contiguous U.S. Our results demonstrated that PRISMA hyperspectral data can reliably track seasonal variability in plant traits, achieving overall R 2 values ranging from 0.78 to 0.88 and normalized root mean square error (NRMSE) values ranging from 5.4% to 8.4% for the four traits. Seasonal patterns revealed bell-shaped trajectories for chlorophyll and carotenoids, while equivalent water thickness decreased steadily across most sites, driven by structural changes during leaf maturation and senescence. Nitrogen content exhibited less pronounced seasonal variation but followed expected nutrient resorption patterns. Analysis of environmental drivers showed that seasonal variability is primarily controlled by solar radiation and day length in northern sites, vapor pressure in semi-arid regions, and temperature in mid-southeastern sites. Spatial variability, meanwhile, was primarily driven by soil properties, particularly during the peak growing season. However, the influence of soil variables slightly declines toward the end of the season at several sites, as climatic factors become more prominent. This study highlights the capability of PRISMA, and potentially other similar spaceborne hyperspectral data for large-scale, time-series plant trait mapping and provides valuable insights into the interactions between plant traits and environmental factors. In conclusion, these findings contribute to advancing our understanding of plant functional ecology and improving predictions of ecosystem responses to environmental changes.

Environmental drivers↗

Decadal-scale recovery of carbon stocks after wildfires throughout the boreal forests

Boreal forests store 30% of the world's terrestrial carbon (C). Consequently, climate change mediated alterations in the boreal forest fire regime can have a significant impact on the global C budget. Here, we synthesize the effects of forest fires on the stocks and recovery rates of C in boreal forests from 368 plots from 16 long-term (= 100 years) fire chronosequences spread throughout the boreal zone. The mean annual temperature varied from -9.5°C to +5.2°C and annual precipitation from 295 mm to 824 mm in the study sites. Total C stocks decreased on average by 60% (range from <10% to >80%) because of forest fires, primarily due to large declines in the living trees and O-layer C stocks. C emissions of fires ranged from 0.1 to 11.4 kg m-2, and in most cases, the emissions were < 4 kg m-2. Total C stocks increased with time since fire following a sigmoidal shape Gompertz function, and it took 125 years until an average asymptote of 8.1 kg C m-2 was reached. Total C stocks accumulated at a rate of 2–60 g m-2 yr-1 during the first 100 years. We found that potential evapotranspiration (PET) was significantly correlated with C stocks and their post-fire recovery, likely because it integrates temperature, radiation and the length of the growing season. If the fire return interval shortens to under 100 years in the future, this suggests that many boreal forests will be prevented from reaching their full C storage potential. However, our results suggest that climate warming-induced increases in PET may also speed up the post-fire recovery of C stocks.

carbon accumulation, carbon pools, chronosequence,↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental drivers of spatial variation in tropical forest canopy height: Insights from NASA’s GEDI spaceborne LiDAR

Forest canopy height is a fundamental ecosystem property—influencing patterns of forest carbon storage and forest ecosystem responses to climate variability and change. Previous studies have analyzed environmental drivers influencing spatial variation in canopy height at landscape-to-regional scales; however, far less is known about the environmental determinants underlying regional and global scale variation in forest canopy height. Using the canopy height metrics products from Global Ecosystem Dynamics Investigation (GEDI), a space-borne Light Detection and Ranging (LiDAR) instrument specifically designed to characterize forest structure, we analyze the environmental correlates of spatial variation of global tropical forest canopy height. Our study demonstrates that climate, topography, and soil properties account for 75% of the variation in tropical forest canopy height. Elevation, dry season length, and solar radiation are the most important drivers in determining canopy height both locally and regionally. These results emphasize the vulnerability of tropical forest structure to ongoing changes in the earth’s climate and provide a valuable empirical baseline for tropical forest management.

Science & Technology - Other Topics↗

Generation of attosecond x-ray pulses with a multi-cycle two-color ESASE scheme

Generation of attosecond x-ray pulses is attracting much attention within the x-ray free-electron laser (FEL) user community. Several schemes using extremely short laser pulses to manipulate the electron bunches have been proposed. In this paper, we extend the attosecond two-color ESASE scheme proposed by Zholents et al. to the long optical cycle regime using a second detuned laser and a tapered undulator. Both lasers can be about ten-optical-cycles long, with the second laser frequency detuned from the first to optimize the contrast between the central and side current spikes. A tapered undulator mitigates the degradation effect of the longitudinal space charge (LSC) force in the undulator and suppresses the FEL gain of all side current peaks. Simulations using the LCLS parameters show a single attosecond x-ray spike of {approx} 110 attoseconds can be produced. The second laser can also be detuned to coherently control the number of the side x-ray spikes and the length of the radiation pulse.

43 PARTICLE ACCELERATORS↗

Dependence of the efficiency of a CdS/CdTe solar cell on the absorbing layer's thickness

On the basis of the continuity equation, the spatial distribution of photogenerated excess electrons in the neutral region of the CdTe layer in a CdS/CdTe heterostructure is analyzed taking into account recombination at the rear surface of the layer. It is demonstrated that, owing to diffusion, excess electrons penetrate deep into the CdTe layer at distances far exceeding the effective penetration length for solar radiation. Calculations of the short-circuit current indicate that, for electron lifetimes of 10{sup -10}-10{sup -9} s, typical of thin-film CdS/CdTe solar cells, recombination losses are insignificant if the CdTe layer's thickness amounts to 3-4 {mu}m but increase dramatically if the thickness is below 1-1.5 {mu}m. In order to eliminate recombination losses in more efficient solar cells where the electron lifetime is {>=}10{sup -8} s the absorbing CdTe layer needs to be much thicker.

36 MATERIALS SCIENCE↗

Concerning the Spatial Heterodyne Spectrometer

A modified Spatial Heterodyne Spectrometer (SHS) is used for measuring atomic emission spectra with high resolution. This device is basically a Fourier Transform Spectrometer, but the Fourier transform is taken in the directions perpendicular to the optical propagation and heterodyned around one preset wavelength. In recent descriptions of this device, one specific phenomenon - the tilt of the energy front of wave packets when diffracted from a grating - was neglected. This led to an overestimate of the resolving power of this spectrograph, especially in situations when the coherence length of the radiation under test is in the order of the effective aperture of the device. In conclusion, the limits of usability are shown here together with some measurements of known spectral lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using the GoAmazon-CHUVA measurements to understand what causes the biases in the onset of the rainy season in Amazonia in climate models

The onset of the Amazon rainy season has a large temporal and spatial variability, and strong impact on aerosols, ecosystems, fire, carbon fluxes, dry season length, agriculture, and hydropower. Two major droughts occurred in the region in the last 20 years, and the dry season has increased in length by about one month. These events highlight the urgency for improving our understanding and capability to project the rainy season onset and drought variability. However, global climate models (CMIP3 and CMIP5) appear to underestimate the past variability, and also project virtually no future change of the onset of rainy season over the Amazon even when they are forced by strong greenhouse forcing under the RCP8.5 scenario. Why these models underestimate the variability of the rainy season onset, and whether this bias implies an underestimate of sensitivity of their dry season length to anthropogenic radiative forcing remain unclear.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of Cryogenic Hydrogen Releases Under Unignited and Ignited Conditions

Hydrogen is increasingly being used in the public sector as a fuel for vehicles. Due to the high density of hydrogen in its liquid phase, fueling stations that receive deliveries of and store hydrogen as a liquid are more practical for high volume stations. There is a critical need for validated models to assess the risk at hydrogen fueling stations with cryogenic hydrogen on-site. In this work, a cryogenic hydrogen release experiment generated controlled releases of cryogenic hydrogen in the laboratory. We measured the maximum ignition distance, flame length and the radiative heat flux and developed correlations to calculate the ignition ditance and the radiative heat flux. We also measured the concentration and temperature fields of releases under unignited conditions and used these measurements to validate a model for these cryogenic conditions. This study provides critical information on the development of models to inform the safety codes and standards of hydrogen infrastructure.

08 HYDROGEN↗

Measurements of the methane relaxation times for application to the infrared emission models of the upper atmospheres of outer planets and Titan

The 7.8 micrometer emission from the nu(sub 4) band of methane (CH4) is a regularly observed feature in the stratosphere of all the giant planets and Titan. On Jupiter, enhancements in this emission are associated with the infrared hot spots in the auroral zone. Attempts to model this phenomenon in particular, and to understand the role of methane in general, have been hampered in part by a lack of adequate laboratory measurements of the collisional relaxation times for the nu(sub 3) and nu(sub 4) levels over the appropriate temperature range. To provide this needed data, a series of laboratory experiments were initiated. In the experimental arrangement the nu(sub3) band of methane is pumped at 3.3 micrometers using a pulsed infrared source (Nd:YAG/dye laser system equipped with a wave-length extender). The radiative lifetime of the nu(sub 3) level (approximately 37 ms) is much shorter than the nu(sub 4) lifetime (approximately 390 ms); however, a rapid V-V energy transfer rate ensures that the nu(sub 4) level is substantially populated. The photoacoustic technique is used to acquire relaxation rate information. The experiments are performed using a low-temperature, low-pressure cell. Experimental apparatus and technique are described. In addition some of the experimental difficulties associated with making these measurements are discussed and some preliminary results are presented.

Halthore, Rangasayi N.↗

The 2x2 quasi-optical power combiner array at 20 GHz

Investigation of a power combiner made of two FET oscillators for an active array are reported. As an approach by a quasi-optical method, a two-dimensional planar array of strongly coupled oscillators by direct connection through a microstrip line is used. In-phase condition between the oscillators as well as in-phase condition of each radiation wave was accomplished by regulating length of feed microstrip lines. The radiation elements of 1 lambda-slot are embedded in a circuit ground plane. At an operation frequency of 20 GHz, in both H- and E-planes, reasonable sigma radiation patterns were obtained which have good agreement with theoretical patterns.

Kawasaki, Shigeo↗

Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of efficiency and assay accuracy. This paper describes an approach denoted the Integrated Cylinder Verification Station (ICVS) that supports 100% cylinder verification, provides volume-averaged cylinder enrichment assay, and reduces inspector manpower needs. To allow field measurements to be collected to validate data collection algorithms, a prototype radiation detector positioning system was constructed. The system was designed to accurately position an array of radiation detectors along the length of a cylinder to measure UF6 enrichment. A number of alternative radiation shields for the detectors were included with the system. A collimated gamma-ray spectrometer module that allows translation of the detectors in the surrounding shielding to adjust the field of view, and a collimating plug in the end to further reduce the low-energy field of view, were also developed. Proof-of-principle measurements of neutron and high-energy gamma-ray signatures, using moderated neutron detectors and large-volume spectrometers in a fixed-geometry, portal-like configuration, supported an early assessment of the viability of the concept. The system has been used successfully on two testing campaigns at an AREVA fuel fabrication plant to scan over 30 product cylinders. This paper will describe the overall design of the detector positioning system and provide an overview of the Integrated Cylinder Verification Station (ICVS) approach.

assay↗

System engineering study of electrodynamic tether as a spaceborne generator and radiator of electromagnetic waves in the ULF/ELF frequency band

The transmission and generation by orbiting tethered satellite systems of information carrying electromagnetic waves in the ULF/ELF frequency band to the Earth at suitably high signal intensities was examined and the system maintaining these intensities in their orbits for long periods of time without excessive onboard power requirements was investigated. The injection quantity power into electromagnetic waves as a function of system parameters such as tether length and orbital height was estimated. The basic equations needed to evaluate alternataing current tethered systems for external energy requirements are presented. The energy equations to tethered systems with various lengths, tether resistances, and radiation resistances, operating at different current values are applied. Radiation resistance as a function of tether length and orbital height is discussed. It is found that ULF/ELF continuously radiating systems could be maintained in orbit with moderate power requirements. The effect of tether length on the power going into electromagnetic waves and whether a single or dual tether system is preferable for the self-driven mode is discussed. It is concluded that the single tether system is preferable over the dual system.

Estes, R. D.↗

Contactless measurements of charge migration within single molecules

Contactless measurements of charge migration were carried out for three pi-conjugated molecules in each of which a bromine atom and an oxygen atom are located on the opposite sides of the aromatic ring. A core hole was generated selectively in the Br atom by x-ray absorption, followed by the Auger cascade, and the subsequent charge migration within the molecule was examined by detecting an O{sup +} ion by means of the coincidence momentum imaging measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗